• 제목/요약/키워드: 철근콘크리트 기둥

검색결과 611건 처리시간 0.023초

탄소섬유시트로 전단 보강된 철근콘크리트 기둥의 유한요소해석 (FEM Analysis of Reinforced Concrete Columns Shear Strengthened with Carbon Fiber Sheets)

  • 이용택;나정민;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권3호
    • /
    • pp.111-118
    • /
    • 2002
  • In this paper, FEM analysis is performed in order to estimate the behavior of RC columns retrofitted with Carbon Fiber Sheet(CFS). Two node truss element and four node isometric plate bond element are used for modeling the CFS and the adhesion between concrete and CFS, respectively. Five specimens with different quantity of CFS are analyzed and compared with experimental results. From the comparison, analytical results show a good agreement with the test results. Therefore, it is advisable to use the FEM used in this paper to predict the behavior of columns with CFS.

반복하중을 받는 철근콘크리트 기둥의 비선형 거동 (Nonlinear Behavior of RC Columns Subjected to Cyclic Loadings)

  • 곽효경;김선필
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.475-482
    • /
    • 2002
  • A moment-curvature relationship to simulate the behavior of reinforced concrete (RC) columns under cyclic loading is introduced. Unlike previous moment4curvature models and the layered section approach, the proposed model takes into account the bond-slip effect by using a monotonic moment-curvature relationship constructed on the basis of the bond-slip relation and corresponding equilibrium equation at each nodal point. In addition, the use of curved unloading and reloading branches inferred from the stress-strain relation of steel gives more exact numerical result. The pinching effect caused by axial force is considered with an assumption that the absorbing energy corresponding to any deformation level maintains constant regardless of the magnitude of applied axial lone. The advantages of the proposed model, comparing to layered section approach, may be on the reduction in calculation time and memory space in case of its application to large structures. Finally, correlation studies between analytical result and experimental studies are conducted to establish the validity of the proposed model.

  • PDF

부재 이력모델을 응용한 연쇄붕괴프로그램 제안 - 선형정적해석 (Development of Progressive Collapse Analysis Program applying hysteresis model - Linear Static Analysis)

  • 김진구;박새로미;서영일
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.144-147
    • /
    • 2011
  • 본 논문에서는 기존의 선형정적해석 절차를 변형하여 부재의 이력모델 응용을 통해 부재 파괴여부에 따라 힌지처리 및 재해석의 반복과정을 자동으로 수행하는 새로운 연쇄붕괴 프로그램을 제안하였다. 6m 4경간의 철근콘크리트 골조에 철골 가새를 보강 설치한 예제구조물에 대하여 최하층 기둥부재를 제거한 후 기존 해석법과 제안 해석법을 통해 선형정적해석을 수행하였고, 그 결과를 비교 분석하였다. 해석 결과, 두 절차 간 부재단위의 파괴여부 및 구조물 힌지 분포 경향의 동일함을 보여 해석의 신뢰성을 확보하였으며. 기존 해석법에 비해 수행단계의 시간이 매우 짧고 자동 반복해석으로 인한 오류의 가능성도 최소화 할 수 있음을 확인하였다.

  • PDF

철근콘크리트 기둥 발파해체를 위한 방호재 특성에 대한 실험적 연구 (Experimental Study on the Characteristics of Protection Materials for Explosive Demolition of Reinforced Concrete Column)

  • 류창하;박용원;김양균
    • 터널과지하공간
    • /
    • 제6권3호
    • /
    • pp.260-266
    • /
    • 1996
  • Safety concern is one of the most important parameters in the design of explosive building demolition. Laboratory experiments were performed to investigate the failure behaviour of concrete columns and the effects of protection materials. Fourteen reinforced columns with two sizes were constructed and the effects of protection materials were tested for two kinds of materials: non woven fabrics and wire net. The results showed that control of gas effects is a key to the control of flying chips. It was recommended to use both wire net and non woven fabrics as primary and secondary protection materials. Such protection method was successfully applied to the explosive demolition of 16 and 17-strory apartment buildings.and the results of a simulation on a model tunneling workings using diesel equipments are introduced. In case of typical model of tunneling face, the gas concentration of human height is about one third of roof concentration and right side half of the tunnel shows better environment than left half. NOx concentration of workings can be estimated about 0.45ppm which is much lower than permissible level(5 ppm).

  • PDF

균열 및 비균열 철근콘크리트 기둥의 탄소섬유시트 전단보강효과에 관한 실험적 연구 (Experimental Study on the Shear Strengthening Effect of Cracked or Uncracked RC Columns with Carbon Fiber Sheets)

  • 나정민;이용택;김승훈;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권4호
    • /
    • pp.243-254
    • /
    • 2002
  • This study investigates the structural behavior of cracked or uncracked RC columns retrofitted with CFS and evaluates the shear retrofit performance through experiment. Experimental works were conducted for sixth specimens varied in the adhesion method of CFS, the ratio of shear reinforcement bar, and the existence of crack before retrofitting. Throughout cyclic test, the strength, stiffness, failure modes, and ductility are discussed. The test results show that the retrofitting method with CFS improve the shear strength and ductility. The crack width below 2mm, occurred before retrofitting, didn't reduce the shear strengthening effect.

탄소섬유시트를 이용하여 보강된 철근콘크리트 기둥의 구조성능에 관한 실험연구 (An Experimental Study of Reinforced Concrete Columns Strengthened by Carbon Fiber Sheet)

  • 박정우;이경훈;홍원기;김희철
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.159-167
    • /
    • 2006
  • Every structure has the expected life span of its own and it has to be rebuilt. New buildings were preferred and put value a quantitative spread of apartment houses because of the rapid growth of national economy. Therefore, the apartment houses were not taken into consideration about maintenances. Carbon fiber sheet is widely used to strengthen old structural members but it is very rarely applied to a construction field for apartment houses. The purpose of this study is to develop effective strengthening methods for reinforced concrete columns using carbon fiber sheets. Eight reinforced concrete column specimens confined by carbon fiber sheet of uniaxial direction were tested using 10,000kN universal testing machine (UTM).

  • PDF

FRP 기둥 재킷 시스템이 보강된 지진 취약 철근콘크리트 건축물의 유한요소해석 (Finite Element Analyses of Seismically Vulnerable Reinforced Concrete Building Frame Retrofitted Using FRP Column Jacketing System)

  • 신지욱;이상열;지동현
    • 한국공간구조학회논문집
    • /
    • 제21권2호
    • /
    • pp.57-66
    • /
    • 2021
  • This study develops finite element models for seismically-deficient reinforced concrete building frame retrofitted using fiber-reinforced polymer jacketing system and validates the finite element models with full-scale dynamic test for as-built and retrofitted conditions. The bond-slip effects measured from a past experimental study were modeled using one-dimensional slide line model, and the bond-slip models were implemented to the finite element models. The finite element model can predict story displacement and inter-story drift ratio with slight simulation variation compared to the measured responses from the full-scale dynamic tests.

폭발 하중에 대한 FRP 재킷 시스템이 보강된 철근콘크리트 기둥 해석 모델 개발 (Numerical Model of FRP Jacketed RC Column Under Blast Loading Scenario)

  • 신지욱
    • 한국공간구조학회논문집
    • /
    • 제21권2호
    • /
    • pp.67-79
    • /
    • 2021
  • This paper aims to develop numerical models for seismically-deficient reinforced concrete columns retrofitted using a fiber-reinforced polymer jacketing system under blast loading scenarios. To accomplish the research goal, a coupling model reproducing blast loads was developed and implemented to the column model. The column model was validated with a past experimental study, and the blast responses were compared to the numerical responses produced by past researchers. The validated modeling method was implemented to the non-retrofitted and retrofitted column models to estimate the effectiveness of the retrofit system. Based on the numerical responses, the retrofit system can significantly reduce the peak dynamic responses under a given blast loading scenario.

철근콘크리트 기둥의 내진성능 및 공학적 손상상태에 대한 실험적 평가 (Experimental Evaluation of the Seismic Performance and Engineering Damage State of Reinforced Concrete Columns)

  • 이도형
    • 한국지진공학회논문집
    • /
    • 제27권2호
    • /
    • pp.119-127
    • /
    • 2023
  • In this paper, seismic performance evaluation was carried out for eight circular reinforced concrete columns designed seismically by KRTA[1]and KCI[8]. Primary design parameters for such columns included many longitudinal reinforcements, yield strength of reinforcements, the vertical spacing of spirals, aspect ratio, and axial force ratio. The test results showed that all the columns exhibited stable hysteretic and inelastic responses. Based on the test results, drift ratios corresponding to each damage state, such as initial yielding, initial cover spalling, initial core concrete crushing, buckling, and fracture of longitudinal reinforcement and final spalled region, were evaluated. Then, those ratios were compared with widely accepted damage limit states. The comparison revealed that the existing damage states were considerably conservative. This implies that additional research is required for the damage limit states of such columns designed seismically by current Korean design codes.

일정 및 변동 축력을 받는 철근콘크리트 기둥의 내진성능 평가 (Seismic Performance Evaluation of Reinforced Concrete Columns Under Constant and Varying Axial Forces)

  • 이도형
    • 한국지진공학회논문집
    • /
    • 제28권1호
    • /
    • pp.59-65
    • /
    • 2024
  • This paper describes the seismic performance evaluation of reinforced concrete bridge columns under constant and varying axial forces. For this purpose, nine identical circular reinforced concrete columns were designed seismically by KIBSE (2021) and KCI (2021). A comparison of lateral forces with theoretical strength shows that the safety factor for columns under varying axial forces is less marginal than those under constant axial forces. In addition, columns under varying axial forces exhibit significant fluctuations in the hysteretic response due to continuously varying axial forces. This is particularly prominent when many varying axial force cycles within a specific lateral loading cycle increase. Moreover, the displacement ductility of columns under varying axial forces does not meet the code-specified required ductility in the range of varying axial forces. All varying axial forces affect columns' strength, stiffness, and displacement ductility. Therefore, axial force variation needs to be considered in the lateral strength evaluation of reinforced concrete bridge columns.