The Inhibitive Effect of Electrochemical Treatment Applied to Fresh/hardened Concrete (철근 부식 방식을 위한 굳지 않은/굳은 콘크리트의 전기방식 적용에 관한 연구)

  • Kim, Sung-Wook;Moon, Jae-Heum;Ann, Ki-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.67-76
    • /
    • 2013
  • In this study, the inhibitive effect of electrochemical treatment subjected to fresh and hardened concrete and literature reviews in terms of the treatment were performed. In hardened concrete, chloride ions are mixed during casting to destroy the passivity of steel, and then the current was provided for 2 weeks with 250, 500 and $750mA/m^2$. After completion of electrochemical treatment, the extraction of chloride ions was quantified and repassivation of steel was observed. Simultaneously, the equated levels of current density for 2 weeks were applied to fresh concrete. Steel-concrete interface in concrete was observed by BSE image analysis and the concrete properties in terms of the diffusivity of chloride ions and the resistance of steel corrosion was measured. As the result, electrochemical treatment is very effectiveness to rehabilitate the passive film on the steel surface and 63-73% of chloride ions in concrete were extracted by the treatment. As the treatment was applied to fresh concrete, the resistance of steel corrosion was improved due to the densification of $Ca(OH)_2$ layers in the vicinity of steel. However, an increase in the current density resulted in an increase in surface chloride content of concrete.

A Study on Chloride Threshold Level of Blended Cement Mortar Using Polarization Resistance Method (분극저항 측정기법을 이용한 혼합 시멘트 모르타르의 임계 염화물 농도에 대한 연구)

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn-Chu;Ann, Ki-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.245-253
    • /
    • 2009
  • The importance of chloride ions in the corrosion of steel in concrete has led to the concept for chloride threshold level (CTL). The CTL can be defined as the content of chlorides at the steel depth that is necessary to sustain local passive film breakdown and hence initiate the corrosion process. Despite the importance of the CTL, due to the uncertainty determining the actual limits in various environments for chloride-induced corrosion, conservative values such as 0.4% by weight of cement or 1.2 kg in 1 $m^3$ concrete have been used in predicting the corrosion-free service life of reinforced concrete structures. The paper studies the CTL for blended cement concrete by comparing the resistance of cementitious binder to the onset of chloride-induced corrosion of steel. Mortar specimens were cast with centrally located steel rebar of 10 mm in diameter using cementitious mortars with ordinary Portland cement (OPC) and mixed mortars replaced with 30% pulverized fuel ash (PFA), 60% ground granulated blast furnace slag (GGBS) and 10% silica fume (SF), respectively, at 0.4 of a free W/B ratio. Chlorides were admixed in mixing water ranging 0.0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0% by weight of binder(Based on $C1^-$). Specimens were curd 28 days at the room temperature, wrapped in polyethylene film to avoid leaching out of chloride and hydroxyl ions. Then the corrosion rate was measured using the polarization resistance method and the order of CTL for binder was determined. Thus, CTL of OPC, 60%GGBS, 30%PFA and 10%SF were determined by 1.6%, 0.45%, 0.8% and 2.15%, respectively.

국내외단신

  • Korea Cement Industrial Association
    • Cement
    • /
    • s.168
    • /
    • pp.69-74
    • /
    • 2005
  • 서울시, 자연녹지에 레미콘공장 허용(2005.7.15)/ 매출 다각화 나섰다, 시멘트업계 건자재 증대, 신사업 진출(2005.7.20)/ "직원과 함께 땀흘린다" 라파즈 그룹 CEO 현장 경영(2005.7.25)/ 한일, "레미탈, 전국권 시멘트로 육성"(2005.7.27)/ 중국산 저질건자재 활개, 비규격 철근 · 시멘트, 국산으로 둔갑/ 중국, 상반기 시멘트 생산량 7.4% 증가(2005.8.2)/ 2010년 일본 건설투자, 51조엔(2005.8.16)/ 건교부, 건설폐기물 재활용 촉진(2005.8.25)/ 시멘트업계 '첨단경영 시대' 성신양회 · 한일 등 정보인프라 시스템 구축(2005.8.31)/ 8.31 부동산종합대책 발표(2005.8.31)/ 동양, 고온가스 재활용 일석이조(2005.9.1)/ 쌍용, 11월 워크아웃 졸업(2005.9.2)/ 일본, 시멘트 수요 호조세(2005.9.12)/ 골재 공급물량 넘친다(2005.9.19)/ 레미콘 공장은 '늘고', 수요는 '줄어'(2005.9.20)

  • PDF

Threshold Chloride Contents of Steel Corrosion in Concrete Containing Chloride (염화물 혼입 콘크리트 중의 철근부식 임계 염화물량)

  • 문한영;김성수;김홍삼;이승태;김은호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.395-398
    • /
    • 2000
  • Recently, increasement of usage contents of sea sand in constructing concrete structures due to insufficiency of high quality river sand, led to many studies for steel corrosion and control methods on it in concrete. But, domestic studies for threshold chloride contents of steel corrosion are not so many as those of foreign states. In this study, the electrochemical test as half cell potential measurement and linear polarization method to estimate the corrosion of steel in contents mixed with several levels chloride contents was performed, thereby, pre-mixed chloride were compared with results measured quantitatively for steel corrosion. And, based on these data, a trial to determine threshold chloride contents of steel corrosion was made.

  • PDF

Static Load Test and Nonlinear Analysis on the PSC Box Girder Bridges with Reduced Reinforcements (철근 물량이 절감된 PSC박스거더교에 대한 정적재하실험 및 비선형해석)

  • 정광회;구현본;김성태;박성룡;박성용;김병석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.591-594
    • /
    • 2003
  • It is reported that the amount of reinforcements for domestic PSC box girder bridges is used two times more that those for foreign PSC box girder bridges, which is considered to be irrational and uneconomical. Therefore, we have come to the conclusion through this study that the advanced design direction can reduce the amount of reinforcements under the condition that the static load test and the nonlinear analysis for the specimen of the PSC box girder bridge with reduced reinforcements which is designed by advanced design direction was carried out in order to verify the validity of the advanced design direction.

  • PDF

Nonlinear Seismic Analysis for Performance Assessment of Hollow RC Bridge Columns with Reinforcement Details for Material Quantity Reduction (물량저감 중공 철근콘크리트 교각의 성능평가를 위한 비선형 지진해석)

  • Kim, Tae Hoon;Lee, Seung Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.221-230
    • /
    • 2014
  • The purpose of this study is to investigate the seismic performance of hollow RC bridge columns with reinforcement details for material quantity reduction. The proposed reinforcement details provide economy, are rational and shorthen the construction periods. The accuracy and objectivity of the assessment process can be enhanced by using a sophisticated nonlinear finite element analysis program. Solution of the equations of motion is obtained by numerical integration using Hilber-Hughes-Taylor (HHT) algorithm. The adopted numerical method gives a realistic prediction of seismic performance throughout the input ground motions for several test specimens investigated. As a result, the proposed reinforcement details for material quantity reduction develop equal performance to that required for existing reinforcement details.

Effect of Time-dependancy of Surface Chloride Content on the Time-to-corrosion Initiation in concrete (콘크리트 표면염화물량의 시간의존성이 철근부식 개시시기에 미치는 영향)

  • Moon, Han-Young;Kim, Hong-Sam;Kim, Seong-Soo;Choi, Doo-Sun;Lee, Jong-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.201-204
    • /
    • 2005
  • The initiation of steel corrosion due to chloride diffusion is predicted to consider time-dependancy of surface chloride content. the profile of chloride concentration is the following: constant condition > square root condition > linear condition From these results, the initiation of steel corrosion in concrete is reverse order of above results of chloride profile. the effect of prolongation to initiation of steel corrosion is decreased with increasing concrete cover

  • PDF

Development of 3-Dimensional Rebar Detail Design and Placing Drawing System (3차원 배근설계 및 배근시공도 작성 자동화 시스템 개발)

  • Choi, Hyun-Chul;Lee, Yunjae;Lee, Si Eun;Kim, Chee Kyeong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.4
    • /
    • pp.289-296
    • /
    • 2014
  • The rebar detailing is an important work influencing the final performance and quality of RC structures. But it is one of the most irrational and illogical activity in construction site. Many groups of workers, including main contractors, structural engineers, shop drawers, rebar fabricators, and etc., participate in this activity. A loosely-organized process for this activity is apt to produce a big amount of rebar loss or even degraded structures. A 3-dimensional rebar auto-placing system, called as Rebar Hub, has been designed and implemented in this research. Rebar Hub provides a totally integrated service from 3D structural modeling of buildings to rebar auto-placing considering anchorage, splice, and the length of ordered rebar. In addition, Rebar Hub can recognize the 2D drawing CAD files and then build 3D structural models which are used for the start point of 3D rebar auto-placing. After rebar auto-placing, each members of the 3D structural model have rebar information belonging to them. It means that the rebar information can be used for the afterward works such as quantity-survey, manufacturing and fabrication of rebars. Rebar Hub is showing outstanding performance while applying to practical projects. It has almost five times productivity and reduces the rebar loss up to 3~8% of the initially-surveyed amount of rebar.

Analysis for the Applicability of Automated Quantity Take-off Technique Using BIM Authoring Tools on Road Construction (BIM 저작도구를 활용한 도로공사 수량산출 자동화 활용성 분석)

  • Moon, Jin-Seok;Sun, Ji-Won;Choi, Won-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5184-5191
    • /
    • 2013
  • The automated quantity take off technique using BIM authoring tools has been recently issued, and the studies of this method for the accuracy, efficiency, and the unit computing for the simple volume, area and number have been developed. Meanwhile the main concerns such as the details for the level of modelling, and the costs and time for the calculating BOQ item are still required to study. In this paper, the earth works, drainage works, pavement works, and facility works using BIM authoring tools are designed in 3D, and the applicability of automated quantity take off technique using BIM authoring tools is discussed, respectively. As a result, automated quantity take off are limited in the earth works, drainage works, pavement works, and facility works. But Most items of BOQ can be supported in Re-bar model.

An Experimental Study on the Structural Performance of Lateral Resistance in Steel Elevator Pit (강재엘리베이터 피트 측압저항 구조성능에 관한 실험적 연구)

  • Hong, Seong-Uk;Kim, Tae-Soo;Baek, Ki-Youl
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.1-8
    • /
    • 2019
  • Steel elevator pit was developed for the purpose of minimizing the excavation, simplifying the construction of the frame and economical efficiency by improving the problems that occurred in the existing reinforced concrete. It is common to apply conventional RC method through excavation to underground structures such as underground floor collector well and elevator pit. In recent years, the use of steel collector well and steel elevator pits to reduce construction costs by minimizing the materials of steel and concrete has been continuously increasing. The steel elevator pit is an underground structure and then the performance of the welding part and the structure system is important. Specimen with only steel plate and concrete without studs could support the load more than 3 times than the specimen with deck only. Therefore, even if there is no stud, the deck (steel plate) rib is formed and the effect of restraining the steel plate and the concrete during the bending action can be expected. However, since sudden fracture in the elevator pit may occur, stud bolt arrangement is necessary for the composite effect of steel plate and concrete. It is expected that the bending strength can be expected to increase by about 15% or more depending with and without stud bolts.