Thermal Environment Analysis of a Classroom by CFD Simulation to Determine Optimal Temperature Sensor Position in Ceiling Type Air-Conditioning System (천정형 에어컨 온도센서의 최적 위치 결정을 위한 교실의 CFD 열환경 분석)

  • Li, M.H.;Kim, D.G.;Kum, J.S.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.43-49
    • /
    • 2006
  • Nowadays, the thermal environments of classrooms are usually adjusted by the ceiling type air-conditioning system with a temperature sensor installed on inlet of an air-conditioner. However, it is not clear that the conventional temperature sensor position is proper to satisfy both thermal comport and energy saving in summer especially. Therefore, this study is aimed at finding out the best position of the temperature sensor on the purpose of the comfort thermal environment and energy saving. The different 5 positions for the temperature sensor are supposed in this paper to analyze thermal environment by CFD. From the analysis through the CFD simulations, the best position of the temperature sensor satisfying for both comfort thermal environment and energy saving is obtained.

  • PDF

A Study on the Process Optimization of Microcellular Foaming Injection Molded Ceiling Air-Conditioner 4-Way Panel (초미세발포 사출성형을 이용한 천정형 에어컨 4-way 판넬의 공정 최적화에 관한 연구)

  • Kim, Joo-Kwon;Lee, Jung-Hee;Kim, Jong-Sun;Lee, Jun-Han;Kwak, Jae-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.98-104
    • /
    • 2018
  • Deflected 4-way panels of ceiling air conditioners produced by injection molding process have caused dew condensation at the edge of products. In order to prevent this drawback with reducing weight and deformation, this study proposed renovated process adopting microcellular foaming. According to results from 2-sample t-test and analysis of variance(ANOVA), the critical factors affecting weight were melt temperature and injection speed. In addition, the vital effects on deformation were structure at the edge, mold temperature and cooling time. Optimal conditions of these parameters were derived by regressive analysis with CAE and response surface method(RSM), and then applied to an actual design and process stage to analyze performance. As a results, it clearly showed that new process improved process capability as well as reduced both weight and deformation by 18.8% and 71.9% respectively compared to the conventional method.

Comparison of the PMV and ADPI according to Adapted Height of Ceiling-type System Air-conditioner in Large space (천정형 정풍량 시스템에어컨의 적용높이에 따른 실내온열환경 특성)

  • Sung, Sang-Chul;Kim, Hyouk-Soon;Chin, Sim-Won;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.590-595
    • /
    • 2009
  • PMV and ADPI were numerically investigated in a large space of various ceiling height with air-conditioning systems of two type. The numerical results showed that it is small that the growth of cooling load according to ceiling height rise in a large space without windows. In case of system air-conditioner of duct type embedded in the ceiling, the air mixing effect in indoor is superior to a case installed 4way cassette type in it. For controling thermal comfort at indoor, a system air-conditioner of duct type embedded in the ceiling is little influenced according to ceiling height rise in a large space considered.