• Title/Summary/Keyword: 척추질환

Search Result 226, Processing Time 0.029 seconds

Regarding the Problem of Clinical Application of New Medical Technology in the Field of Spine Surgery Found through the Case of Intradiscal Electrothermal Therapy (추간판 내열 치료술(Intradiscal Electrothermal Therapy)의 사례를 통해 발견되는 척수 수술 영역 신의료기술의 임상 적용 과정의 문제에 관하여)

  • Hong, Youngki
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.7
    • /
    • pp.652-662
    • /
    • 2022
  • Currently, in the field of spinal surgery around the world, various new technologies have been rapidly developed and applied to patients. The author believes that it is necessary to discuss whether these new technologies are being fully reviewed for efficacy and safety before being applied to patients. To consider this issue, the author analyzed the basic research data and clinical application process of the intradiscal electrothermal therapy, which was developed as a new technology for discogenic pain disease in the 2000s and has been widely used worldwide. As a result, it was found that this procedure has been performed on patients in a state where there is insufficient base research on efficacy and safety. The author judges that this case reveals an essential problem related to the clinical operation of new medical technologies in the field of spine surgery. Therefore, the author believes that in order to minimize the side effects that new medical technology in the field of spinal surgery may have on patients, more full-fledged basic research and higher clinical acceptance standards should be established.

Imaging Evaluation of Early and Long-Term Complications Associated with the Postoperative Spine (척추 수술 후 영상 평가: 초기 및 중장기 합병증)

  • Jae Hwi Park;Dong Hyun Kim;Jee Won Chai;Hyo Jin Kim;Jiwoon Seo;Jin Young Son
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.36-53
    • /
    • 2024
  • As the number of spinal surgeries being performed expands, the number of medical imaging procedures such as radiography, CT, and MRI is also increasing, and the importance of their interpretation is becoming more significant. Herein, we present the radiological findings of a variety of complications that can occur after spinal surgery and discuss how effectively and accurately they can be diagnosed through imaging. In particular, this study details the characteristic imaging findings specific to the early and long-term postoperative periods. Early complications of spinal surgery include improper placement of surgical instruments (instrument malpositioning), seromas, hematomas, pseudomeningoceles, and infections in the region surrounding the surgical site. Conversely, long-term complications may include osteolysis around surgical instruments, failure of fusion, adjacent segment disease, and the formation of epidural fibrosis or scar tissue. A precise understanding of the imaging assessments related to complications arising after spinal surgery is crucial to ensure timely and accurate diagnosis, which is necessary to achieve effective treatment.

The Complications of the Graf Stabilization for Lumbar Disc Herniation with Posterior Instability (후방불안정성을 동반한 요추 추간판 탈출증에서 Graf 고정술후 발생한 합병증 분석)

  • Park, Joo-Tae;Shin, Young-Shik;Yang, Jeong-Ho;Min, Kang-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.1
    • /
    • pp.164-172
    • /
    • 1998
  • The Graf stabilization has been introduced in treating lumbar spinal disorder associated with posterior instability. This study reviewed some problems of the Graf instrumentation as a soft stabilizer. The purpose of this study is to analyse the problems of the soft stabilization in spinal instability. We reviewed 145 cases which were operative treatment using the Graf instrument for lumbar spinal disorder associated with posterior instability at our department from May, 1991 to Dec, 1995. The mean follow up periods was 29 months ranging from 24 months to 6 years 8 months. Of the 145 cases, 22 cases were showed the problem. The diagnostic method were simple x-ray, flexion-extension lateral stress view and CT scan. Results were as follows: Adjacent segmental instability was 10 cases(6.9%), disc space narrowing was 8 cases(5.5%), screw loosening was 3 cases(2.1%) and breakage of the Graf band was 1 case(0.6%). The problems of the soft stabilization were adjacent segmental instability, disc space narrowing, screw loosening, and breakage of the Graf band. But the rate of adjacent segmental instability and disc space narrowing was lower than other lumbar spinal instrumentation.

  • PDF

Cervical Vascular Diseases Rarely Observed by Duplex Sonography: 3 Cases (이중초음파에서 드물게 관찰되는 목 부위의 혈관질환: 3례)

  • Han, Minho;Seo, Kangsik;Choi, Junghye
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.131-136
    • /
    • 2021
  • Duplex sonography is used widely in various medical fields because of its repeatability and low cost. In particular, the carotid duplex sonography is a useful non-invasive test for diagnosing cerebrovascular disease and predicting the prognosis. In clinical practice, it is very important to reduce the test time and improve accuracy. The patient's clinical information must be known in advance to perform carotid duplex sonography quickly and accurately. Despite this, there are often difficulties finding new cervical vascular diseases that are not mentioned in the clinical information. Therefore, knowing a variety of cases can lead to fast and accurate results. In this context, this paper reports three cases of cervical vascular disease discovered unexpectedly during carotid duplex sonography: CASE 1, internal carotid artery occlusion and cerebral arteries branched from the external carotid artery; CASE 2, internal jugular vein thrombosis; CASE 3, microembolism observed in the vertebral artery.

Immunoglobulin G4-Related Disease in the Thorax: Imaging Findings and Differential Diagnosis (흉부에서 발생한 IgG4 연관 질환: 영상 소견 및 감별진단)

  • Yookyung Kim;Hye Young Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.826-837
    • /
    • 2021
  • Immunoglobulin G4-related disease (IgG4-RD) is a chronic inflammatory condition involving multiple organs, including the salivary or lacrimal glands, orbit, pancreas, bile duct, liver, kidney, retroperitoneum, aorta, lung, and lymph nodes. It is histologically characterized by tissue infiltration with lymphocytes and IgG4-secreting plasma cells, storiform fibrosis, and obliterative phlebitis. In the thoracic involvement of IgG4-RD, mediastinal lymphadenopathy and perilymphangitic interstitial thickening of the lung are the most common findings. Peribronchovascular and septal thickening and paravertebral band-like soft tissue are characteristic findings of IgG4-RD. Other findings include pulmonary nodules or masses, ground-glass opacity, alveolar interstitial thickening, pleural effusion or thickening, mass in the chest wall or mediastinum, and arteritis involving the aorta and coronary artery. Radiologic differential diagnosis of various malignancies, infections, and inflammatory conditions is needed. In this review, we describe the imaging findings of IgG4-RD and the radiologic differential diagnoses in the thorax.

Recent Interventional Procedures for Spinal Discogenic Pain for Life Care : Technical and Ethical Issues (라이프케어를 위한 추간판성 통증 치료의 최신중재기법 기술적 윤리적 문제들에 관하여)

  • Hong, Young-Ki
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.4
    • /
    • pp.311-320
    • /
    • 2019
  • Discogenic pain which develops during the degenerative process of intervertebral disc is an intractable disease of musculoskeletal system. Unlike other diseases in modern medical science, it is not clinically confirmed through objective imaging and clinicopathologic index. Moreover, current technology has been facing difficulties finding fundamental treatment. This study examined through reviewing literature whether the therapeutic rationales of interventional procedures for the discogenic pain, such as nerve block, intradiscal electrothermal therapy and nucleoplasty, are valid and whether safety reviews such as preclinical tests are carried out faithfully during the technology development process. As a result, it is presumed that there is not yet an interventional treatment for discogenic pain, whose therapeutic rationale has been objectively verified. And there are some cases of interventional treatment that have not been adequately equipped with the preclinical test steps necessary to review the safety of the procedure during the technology development process. In conclusion, since there is still no interventional treatment for discogenic pain which has clear therapeutic rationale, it is necessary to recognize that a more careful approach is needed to judge whether the procedure is performed in clinical settings. And medical ethical issues may arise for some interventional treatment that are deemed to have been carried out without a thorough review of safety.

SNR and ADC Changes at Increasing b Values among Patients with Lumbar Vertebral Compression Fracture on 1.5T MR Diffusion Weighted Images (1.5T MR 기기를 이용한 확산강조영상에서 b Value의 증가에 따른 요추압박골절 환자의 신호대 잡음비와 현성 확산 계수의 변화)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.52-59
    • /
    • 2010
  • To examine among patients with vertebral compression fracture the extent to which signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values at the lumbar vertebral compression fracture site vary on diffusion-weighted MR images according to varying b values on the 1.5T MR device. Diffusion-weighted MR images of 30 patients with compression fracture due to chronic osteoporosis who underwent vertebral MRI from Jan. 2008 to Nov. 2009 were respectively obtained using a 1.5-T MR scanner with the b values increased from 400, 600, 800, 1,000 to $1,200\;s/mm^2$. For diffusion-weighted MR images with different b values, the signal-to-noise ratio (SNR) was assessed at three sites: the site of compression fracture of the lumbar vertebral body at L1 to L5, and both the upper and lower discs of the said fracture site, while for ADC map images with different b values, the SNR and ADC were respectively assessed at those three sites. As a quantitative analysis, diffusion-weighted MR images and ADC map images with b value of $400\;s/mm^2$ (the base b values) were respectively compared with the corresponding images with each different b value. As far as qualitative analysis is concerned, for both diffusion-weighted MR and ADC map images with b value of $400\;s/mm^2$, the extent to which signal intensity values obtained at the site of compression fracture of the lumbar vertebral body at L1 to L5 vary according to the increasing b values were examined. The quantitative analysis found that for both diffusion-weighted MR and ADC map images, as the b values increased, the SNR were relatively lowered at all the three sites, compared to the base b value. Also, it was found that as the b values increased, ADC valueswere relatively lowered at all the three sites on ADC map images. On the other hand, the qualitative analysis found that as the b values increased to more than $400\;s/mm^2$, the signal intensity gradually decreased at all the sites, while at the levels of more than $1,000\;s/mm^2$, severe image noises appeared at all of the three sites. In addition, higher signal intensity was found at the site of compression fracture of the lumbar vertebral body than at the discs. Findings showed that with the b value being increased, both the signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values gradually decreased at all the sites of the lumbar vertebral compression fracture and both the upper and lower discs of the fracture site, suggesting that there is a possibility of a wider range of applications to assessment of various vertebral pathologies by utilizing multi b values in the diffusion-weighted MRI examination.

A Study on the Assistive System for Body Correction (신체 교정을 위한 보조 시스템에 관한 연구)

  • Kim, Ho-Joon;Chung, Jae-Pil
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.4
    • /
    • pp.231-235
    • /
    • 2011
  • In these day, the number of people who have an abnormal posture caused by bad habit are increasing. Therefore, people suffer various disease and symptoms. For correcting the posture to cure, we need continuous monitor, expenditure of time and money. In this study, we develop a posture correcting aid system in other to monitor a posture continuously and leads to pose correctly and records postural variation which are attached to the neck and the waist. The devised system showed good potential for the correct posture guide and a cure of postural defect.

Multiple Fractures in Thoracic Vertebrae after Epilepsy (뇌전증 발작 후 발생한 다발성 흉추 골절)

  • Ha, Dae-Ho;Oh, Sung-Kyun;Kim, Seung-Min
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.3
    • /
    • pp.266-270
    • /
    • 2020
  • The musculoskeletal system can be damaged by massive contractions of the muscles in the case of systemic attacks by epilepsy. Several studies or case reports of multiple thoracic vertebrae fractures following generalized seizures without underlying diseases or falls have been reported, but there are few domestic studies or case reports. This paper reports the case of a 42-year-old male patient without any specific underlying disease, who was diagnosed with multiple fractures of the thoracic vertebrae caused by generalized myoclonic epilepsy during sleep.

Early Failure of Cortical-Bone Screw Fixation in the Lumbar Spinal Stenosis (요추부 협착에서의 피질골 궤도 나사못 고정의 초기 실패 사례에 대한 고찰)

  • Kwon, Ji-Won;Kim, Jin-Gyu;Ha, Joong-Won;Moon, Seong-Hwan;Lee, Hwan-Mo;Park, Yung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.5
    • /
    • pp.405-410
    • /
    • 2020
  • Purpose: Pedicle screw insertion has been traditionally used as a surgical treatment for degenerative lumbar spine disease. As an alternative, the cortical-bone trajectory screw allows less invasive posterior lumbar fixation and excellent mechanical stability, as reported in several biomechanical studies. This study evaluated the clinical and radiological results of a case of early failure of cortical-bone screw fixation in posterior fixation and union after posterior decompression. Materials and Methods: This study examined 311 patients who underwent surgical treatment from 2013 to 2018 using cortical orbital screws as an alternative to traditional pedicle screw fixation for degenerative spinal stenosis and anterior spine dislocation of the lumbar spine. Early fixation failure after surgery was defined as fixation failure, such as loosening, pull-out, and breakage of the screw on computed tomography (CT) and radiographs at a follow-up of six months. Results: Early fixation failure occurred in 46 out of 311 cases (14.8%), screw loosening in 46 cases (14.8%), pull-out in 12 cases (3.9%), and breakage in four cases (1.3%). An analysis of the site where the fixation failure occurred revealed the following, L1 in seven cases (15.2%), L2 in three cases (6.5%), L3 in four cases (8.7%), L4 in four cases (8.7%), L5 in four cases (8.7%), and S1 in 24 cases (52.2%). Among the distal cortical bone screws, fixation failures such as loosening, pull-out, and breakage occurred mainly in the S1 screws. Conclusion: Cortical-bone trajectory screw fixation may be an alternative with comparable clinical outcomes or fewer complications compared to conventional pedicle screw fixation. On the other hand, in case with osteoporosis and no anterior support structure particularly at L5-S1 fusion sites were observed to have result of premature fixation failures such as relaxation, pull-out, and breakage.