• Title/Summary/Keyword: 척추종양

Search Result 106, Processing Time 0.03 seconds

Radiation Therapy of Suprasellar Germ Cell Tumors (뇌하수체상부 배아세포종의 방사선치료 성적)

  • Park Woo Yoon;Choi Doo Ho;Choi Eun Kyung;Kim Il Han;Ha Sung Whan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.169-176
    • /
    • 1988
  • A retrospective study was performed on 15 patients with suprasellar germ cell tumors treated by megavoltage external beam irradiation between Feb. 1979 and Dec. 1985. Follow-up period of survivors was 30 to 91 months. Histologic diagnosis was obtained before radiation therapy in 10patients (9 germinomas and 1 mixed). Five patients were treated without histologic verification. In 9 patients with biopsy-proven germinomas radiation therapy was delivered to the craniospinal axis in 6, to the whole brain in 3. In 5 patients with mixed germ cell tumor or elevated tumor marker, irradiation was delievered to the craniospinal axis in 2, to the whole brain in 2, and to the primary site only in 1. Total doses ranged from 5,000 to 5,500 cGy to the primary site, 3,000 to 4,400 cGy to the whole brain, and 1,300 to 3,000 cGy to the spine. In these 14, local tumor was controlled and primary or spinal failure was not observed. One patient without elevated tumor marker was treated to the whole brain. The tumor was not controlled and he had spinal recurrence. Overall survival and disease-free survival rates were $86\%$ at 5 year. It is proven that radiation therapy is an effective treatment for suprasellar germ cell tumors. The neuroendocrinologic presentation, tumor marker status, early response to radiation measured on CT seem to be useful means for selecting patients for radiation therapy when tissue diagnosis is not available.

  • PDF

A Thoracolumbar Pure Spinal Epidural Cavernous Hemangioma - A Case Report - (흉요추부에서 발견된 경막외 해면상 혈관종 - 증례 보고 -)

  • Choi, Byeong Sam;Kim, Ju Yeon;Lee, Sungjoon
    • Journal of Korean Society of Spine Surgery
    • /
    • v.25 no.4
    • /
    • pp.169-174
    • /
    • 2018
  • Study Design: Case report. Objectives: We report a case of pure epidural cavernous hemangioma located at the thoracolumbar spine in a 53-year-old woman that mimicked a neurogenic tumor on magnetic resonance imaging (MRI). Summary of Literature Review: A pure spinal epidural cavernous hemangioma without bony involvement is a very rare lesion about which limited information is available in the literature. Materials and Methods: A 53-year-old woman visited our clinic for hypoesthesia with a tingling sensation in the left anterolateral thigh that had begun a month ago. No other neurologic symptoms or signs were present upon a neurologic examination. MRI from an outside hospital showed a $2.0{\times}0.5cm$ elongated mass at the T11-12 left neural foramen. The tumor was completely removed in piecemeal fashion. Results: The histopathologic examination revealed a cavernous hemangioma, which was the final diagnosis. The outcome was favorable in that only operation-related mild back pain remained, without any neurologic deficits, after a postoperative follow-up of 2 years and 3 months. No recurrence was observed on MRI at 2 years postoperatively. Conclusion: Pure epidural spinal cavernous hemangioma is very rare, and it is very difficult to differentiate from other epidural lesions. However, we believe that it should be included in the differential diagnosis of spinal epidural tumors due to its favorable prognosis.

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF

Assessment of the Optic-guided Patient Positioning for Spinal Stereotactic Radiosurgery Using Novalis ExacTrac System (노발리스 ExacTrac system을 이용한 척추 정위 방사선수술 방법 평가)

  • 이동준;손문준;최광영;이기택;최찬영;황금철;황충진
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.218-223
    • /
    • 2002
  • Stereotactic radiosurgery for intracranial lesion is well established since the Lars Leksell first introduced radiosurgery concept in 1951 Its use in the treatment of spinal lesion has been limited by the availability of effective immobilization devices. The first clinical experience of the spinal stereotactic radiosurgery technique was reported by Hamilton AJ. in 1995. Recently, Optic-guided patient positioning technique for extracranial stereotactic radiosurgery was developed and reported. This study is for assess the target positioning accuracy of the optic guided patient positioning system Exactrac (BrainLab., Inc, Germany). We have designed phantom for assess the accuracy of spinal stereotactic radiosurgery The infrared reflective body markers attached to the relatively immobile part of the body and a series of 2 mm CT images was taken. The image sets were transferred to the planning computer. During the radiosurgery treatment, we measure the real-time display showing the positioning values from Exactrac computer. And we compare the isocenter deviation from irradiated center point of the film which was mounted on the lesion site of the phantom and pin hole site of that film. The accuracy of the ExacTrac system in positioning a target point shows enough for the clinical applications.

  • PDF

Imaging Findings of Spinal Metastases with Differential Diagnosis: Focusing on Solitary Spinal Lesion in Older Patients (전이성 척추 종양의 영상 소견: 고령 환자의 단일병소를 중심으로 한 감별 질환)

  • Sun-Young Park;Min A Yoon;Min Hee Lee;Sang Hoon Lee;Hye Won Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.77-94
    • /
    • 2024
  • If a solitary spinal lesion is found in an older patient, bone metastasis can be primarily considered as the diagnosis. Bone metastasis can occur anywhere, but it mostly occurs in the vertebral body and may sometimes show typical imaging findings, presenting as a single lesion. Therefore, differentiating it from other lesions that mimic bone metastases can be challenging, potentially leading to delayed diagnosis and initiation of primary cancer treatment. This review provides an overview of imaging findings and clinical guidelines for bone metastases and discusses its differences from other diseases that can occur as solitary spinal lesions in older patients.

Osteochondroma in Cervical Spine - 1 Case Report - (경추에서 발생한 골연골종 - 1예 보고 -)

  • Na, Hwa-Yeop;Lee, Young-Sang;Choi, Joon-Cheol;Choi, Jun-Won;Kim, Woo-Sung;Song, Woo-Suk;Noh, Hyoun-Min
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.14 no.1
    • /
    • pp.73-77
    • /
    • 2008
  • Osteochondroma is the most common benign tumor in bone, consist of 40%, but, rare in spine area occupying only 2%. We report a case of osteochondroma that was in the 5th and 6th spinous process of cervical spine. We performed en bloc excisional biopsy of the bony mass. And the patient is doing well without evidence of local recurrence at 1 year after surgery. Further follow-up is necessary to observe local recurrence.

  • PDF

Diagnosis of Primary Malignant Lesion Using $^{18}F$ FDG PET/CT in Metastatic Bone Tumor (전이성 골종양에서 $^{18}F$ FDG PET/CT를 이용한 원발성 악성 질환의 진단)

  • Yoon, Hoi-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.14 no.1
    • /
    • pp.44-50
    • /
    • 2008
  • Purpose: To evaluate usefulness in diagnosing primary malignant lesion of metastatic bone tumor using $^{18}F$ FDG PET/CT. Material & Methods: Retrospective analysis was executed on 5,452 patients who were taken with $^{18}F$ FDG PET/CT between December 2003 and December 2007. 180 patients who had not any history of malignancy and complained musculoskeletal pain and had ill-defined osteolytic lesion in plain X-ray, were included. 96 male and 84 female were enrolled and mean age was 59.1 year old (22~90). We analyzed diagnostic accuracy, age and sex distribution of primary malignant lesion, location of metastatic lesion. Results: We could confirmed primary malignant lesion in 152 cases (84.4%). Most common malignant primary lesion was lung (28.3%), breast (18.9%) and gastrointestinal system (16.7%) and spine was the most common metastatic location of primary malignant lesion. Conclusion: $^{18}F$ FDG PET/CT is a effective molecular imaging detecting primary malignant lesion in patients having metastatic bone lesion without history of malignancy.

  • PDF

Differentiation of Malignant from Benign Soft-Tissue Solid Tumors: Clinical and MR Finding Complex (연조직고형종양의 악성과 양성 감별: 임상과 자기공명영상 복합소견)

  • Moon, Tae-Yong;Kim, Jung-Il;Shin, Su-Mi;Choo, Hye-Jeung;Choi, Hyun-Wook;Kim, Soo-Jin
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.79-87
    • /
    • 2004
  • Purpose: The recent development of MR has made to possible radiological diagnosis in various soft tssue tumors. But multifarious components within soft tissue tumors and their periodic change have made to difficult even differentiation of malignant from benign soft tissue tumors solely on the MR. So authors retry to differentiate malignant from benign soft tissue tumors with clinical and MR finding complex. Materials and methods: We were analysed 82 pathologically confirmed soft tissue solid tumors (37 cases as malignancy including intermediate tumors and 45 cases as benign including inflammatory masses) which are correlated with clinical findings such as age, size, and location, MR findings such as tumor border, texture on T2 and contrast-T1 images, and enhancement area retrospectively. Many typical lipoma and cysts including of ganglion and abscess are rejected in the benign soft tissue tumor group because not difficult to diagnose on MR. Results: Malignant soft tissue tumors were more frequent in 21~40 and 61~80 years old of the age, above 3.0 cm of the size, trunk-pelvis-lower extremities of the location, and MR findings with irregular border and above 50% of the enhancement area than those of benign soft tissue tumors. Conclusion: The clinical finding that divided to two locations as trunk-pelvis-lower extremities and upper extremities-shoulder-spine was statistically significant to differentiate malignant from benign soft tissue solid tumors. However, the others would provide some useful informations to differentiate them never specific.

  • PDF

Comparison of IMRT and VMAT Techniques in Spine Stereotactic Radiosurgery with International Spine Radiosurgery Consortium Consensus Guidelines (International Spine Radiosurgery Consortium Consensus Guidelines에 따른 Spine Stereotactic Radiosurgery에서 IMRT와 VMAT의 비교연구)

  • Oh, Se An;Kang, Min Kyu;Kim, Sung Kyu;Yea, Ji Woon
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.145-153
    • /
    • 2013
  • Stereotactic body radiation therapy (SBRT) is increasingly used to treat spinal metastases. To achieve the highest steep dose gradients and conformal dose distributions of target tumors, intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques are essential to spine radiosurgery. The purpose of the study was to qualitatively compare IMRT and VMAT techniques with International Spine Radiosurgery Consortium (ISRC) contoured consensus guidelines for target volume definition. Planning target volume (PTV) was categorized as TB, $T_{BPT}$ and $T_{ST}$ depending on sectors involved; $T_B$ (vertebral body only), $T_{BPT}$ (vertebral body+pedicle+transverse process), and $T_{ST}$ (spinous process+transverse process). Three patients treated for spinal tumor in the cervical, thoracic, and lumbar region were selected. Eacg tumor was contoured by the definition from the ISRC guideline. Maximum spinal cord dose were 12.46 Gy, 12.17 Gy and 11.36 Gy for $T_B$, $T_{BPT}$ and $T_{ST}$ sites, and 11.81 Gy, 12.19 Gy and 11.99 Gy for the IMRT, RA1 and RA2 techniques, respectively. Average fall-off dose distance from 90% to 50% isodose line for $T_B$, $T_{BPT}$, and $T_{ST}$ sites were 3.5 mm, 3.3 mm and 3.9 mm and 3.7 mm, 3.7 mm and 3.3 mm for the IMRT, RA1 and RA2 techniques, respectively. For the most complicated target $T_{BPT}$ sites in the cervical, thoracic and lumbar regions, the conformity index of the IMRT, RA1 and RA2 is 0.621, 0.761 and 0.817 and 0.755, 0.796 and 0.824 for rDHI. Both IMRT and VMAT techniques delivered high conformal dose distributions in spine stereotactic radiosurgery. However, if the target volume includes the vertebral body, pedicle, and transverse process, IMRT planning resulted in insufficient conformity index, compared to VMAT planning. Nevertheless, IMRT technique was more effective in reducing the maximum spinal cord dose compared to RA1 and RA2 techniques at most sites.

Monostotic Fibrous Dysplasia in the Spine - A Case Report - (척추에 발생한 단골성 섬유 이형성증 - 증례 보고-)

  • Yang, Jun-Young;Lee, June-Kyu;Lee, Jun-Ho;Yang, Jae-Hoon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.2
    • /
    • pp.188-193
    • /
    • 2005
  • Fibrous dysplasia is a condition characterized by the replacement of the medullary component of predominantly long bone with fibrous tissues. The monostotic form of the fibrous dysplasia occurs more frequent than the polyostotic form. Only the twenty three previous cases of vertebral involvement in monostotic fibrous dysplasia have been reported. Authors experienced a case of monostotic fibrous dysplasia of the third lumbar vertebra, so we report this case. Report details the diagnosis and treatment of a 34 years old man with back pain from monostotic fibrous dysplasia of the third lumbar vertebra. We discuss the experience in the consideration of previous report to recommend the optimal management of this disease.

  • PDF