• Title/Summary/Keyword: 챔버시험

Search Result 317, Processing Time 0.023 seconds

A Study on the Efficiency Estimation of Halogen free Fire Resistance Cable (저독성 내화전선 케이블의 성능평가에 관한 연구)

  • 윤헌주;홍진웅;유동일;윤재선;곽동일
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.18-23
    • /
    • 2002
  • Efficiency estimation of toxicity free resistance cable experiments were conducts to understand toxicity free fire ersistance polyolefin insulation material and smoke density characteristic and combustion gas corrosion analysis. A main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Similar patterned fire incidents such as, Inchon Live-Hof Pub Restaurant as, Sea-land Children Resort have proven that serious loss of lives were caused by hazardous gas generated fire resistance cable materials. In this paper, Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5$\pm40.04〔w/$\textrm{cm}^2$〕for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. Also, the fire gases was occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC which has high content of carbon in chemical compound.

Effect of Temperature on Interlaminar Fracture Toughness of Filament-Wound Carbon/Epoxy Composites (필라멘트 와인딩된 카본/에폭시 복합재의 층간파괴인성에 미치는 온도 영향)

  • Im, JaeMoon;Shin, KwangBok;Hwang, Taekyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.5
    • /
    • pp.491-497
    • /
    • 2015
  • This paper reports an experimental study for evaluating the effect of temperature on the mode I, mode II and mixed-mode interlaminar fracture toughness of adhesive joints with a curved cross-section of filament-wound dome-separated composite pressure vessel. Mode I and mixed-mode interlaminar fracture toughness were evaluated using DCB specimens, while mode II interlaminar fracture toughness was determined using ENF specimens. $[{\pm}10^{\circ}]_6$, $[{\pm}27^{\circ}]_6$ and ($[{\pm}10^{\circ}]_3/FM73/[{\pm}27^{\circ}]_3$) winding specimens with the curved cross-section were considered. In-situ temperature environments were simulated with a range of $-30^{\circ}C-60^{\circ}C$ using an environmental chamber and furnace. Experimental results on the effect of temperature indicate that interlaminar fracture toughness tends to be high at low temperature and is degraded with increase in temperature. For specimen types, it was found that interlaminar fracture toughness of $[{\pm}10^{\circ}]_3/FM73/[{\pm}27^{\circ}]_3$ winding specimens considered as adhesive joints of dome and helical part was higher than other specimens.

Numerical Analysis of EPB TBM Driving using Coupled DEM-FDM Part I : Modeling (개별요소법과 유한차분법 연계 해석을 이용한 EPB TBM 굴진해석 Part I : 모델링)

  • Choi, Soon-wook;Lee, Hyobum;Choi, Hangseok;Chang, Soo-Ho;Kang, Tae-Ho;Lee, Chulho
    • Tunnel and Underground Space
    • /
    • v.30 no.5
    • /
    • pp.484-495
    • /
    • 2020
  • To numerically simulate the advance of EPB TBM, various type of numerical analysis methods have been adopted including discrete element method (DEM), finite element method (FEM), and finite difference method (FDM). In this paper, an EPB TBM driving model was proposed by using coupled DEM-FDM. In the numerical model, DEM was applied in the TBM excavation area, and contact properties of particles were calibrated by a series of triaxial tests. Since the ground around the excavation area was coupled with FDM, the horizontal stress considering the coefficient of earth pressure at rest could be applied. Also, the number of required particles was reduced and the efficiency of the analysis was increased. The proposed model can control the advance rate and rotational speed of the cutter head and screw conveyor, and derive the torque, thrust force, chamber pressure, and discharging during TBM tunnelling.

A Study on Rotation Method Appling Slip-ring of Direction Finding Antenna Mast for Mobile Radio Wave Measurement System (이동형 전파측정시스템에서 슬립링을 적용한 방향탐지 안테나 마스트 회전 방법에 관한 연구)

  • Sohn, Ju-Hang;Han, In-Sung;Kim, Duck-Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.499-504
    • /
    • 2017
  • A Mobile Radio Wave Measurement System (MRWMS)is a vehicle-mounted system designed to be operating in a single mission. The mission characteristic for mobile measurement requires mobility. For this, we must consider the arrangement and embedded method of MRWMS's antennas. In this paper, we described the measurement method design of direction detecting accuracy for MRWMS and designed the direction finding antenna mast capable of rotating itself by using a slip ring without turntable for Direction Finding (DF) accuracy test. As we removed the dependency of a limited local area by designing a measurement method of direction detecting accuracy, Equipment Under Test (EUT) zero-Adjustment and mounted process shortened. So, we the reduced production costs. We expect an improved cable loss value by shortening the RF cable length in accordance with our design. In addition, due to the same phenomenon, the entire system is lighter and the mobility is improved.

A Study on the Performance Improvement of Bar Code Reader for the Automatic Processing of the Mail Items (우편물 자동처리를 위한 바코드 판독기 성능개선에 관한 연구)

  • Park, Moon-Sung;Nam, Yun-Seok;Kim, Hey-Kyu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2001.04b
    • /
    • pp.731-734
    • /
    • 2001
  • 우편물을 집배원이 배달하는 순서로 자동구분 처리하기 위한 요소기술 줌에서 4-state 바코드 시스템이 개발되고 있으며 우편번호, 배달순서코드, 고객정보 등이 적용될 예정이다. 기존의 고객 바코드 판독 시스템은 우편물상의 바코드 심볼로지가 존재하는 판독대상 영역의 기울기가 ${\pm}4.47^{\circ}$ 이하이고, 심볼의 훼손과 잡영이 없을 경우에 $79{\sim}100msec(35,000{\sim}45,000$통/시간)의 속도로 자동 구분 정보가 판독된다. 본 논문에서는 판독범위 및 판독성능을 개선을 위하여 CCD(Charge Coupled Device) 센서로부터 획득된 이미지상에서 존재하는 심볼로지 정보의 고속판독 방법을 제시한 것이다. 이 판독방법은 그레이(gray) 이미지 바탕면의 경계값(threshold) 기울기 분포를 기준으로 2개의 경계값을 설정하여 판독대상 정보를 획득하였다. 또한, 4-state 바코드 심볼로지의 존재 가능성 영역만을 탐색하고, 판독대상 영역에서 트래커(tracker)를 탐색하여 심볼로지의 기울기값, 심볼로지 경계값, 심볼위치 좌표값을 생성한 후 심볼값이 판독한 것이다. 판독시험 결과는 판독대상 영역의 심볼로지가 ${\pm}45^{\circ}$ 기울어지고, 잡영이 존재할 경우에도 $30{\sim}60msec(58,000{\sim}l16,000$통/시간) 이내에 판독되었다. 우편물 자동구분용 바코드 판독기로써 적용될 경우에 판독속도가 평균 57.25% 이상 개선되고, 판독범위의 확장으로 0.2%의 기계적인 오류(이송과정예서의 Jam 발생 비율)를 제외할 경우에 거의 99.8% 우편물을 판독하여 자동구분 처리할 수 있게 될 것으로 기대된다.onebook 엑세스 모들(Server Phonebook Access Module)로 구성되어 있다.외 보다 높았다(I/O ratio 2.5). BTEX의 상대적 함량도 실내가 실외보다 높아 실내에도 발생원이 있음을 암시하고 있다. 자료 분석결과 유치원 실내의 벤젠은 실외로부터 유입되고 있었고, 톨루엔, 에틸벤젠, 크실렌은 실외뿐 아니라 실내에서도 발생하고 있었다. 정량한 8개 화합물 각각과 총 휘발성 유기화합물의 스피어만 상관계수는 벤젠을 제외하고는 모두 유의하였다. 이중 톨루엔과 크실렌은 총 휘발성 유기화합물과 좋은 상관성 (톨루엔 0.76, 크실렌, 0.87)을 나타내었다. 이 연구는 톨루엔과 크실렌이 총 휘발성 유기화합물의 좋은 지표를 사용될 있고, 톨루엔, 에틸벤젠, 크실렌 등 많은 휘발성 유기화합물의 발생원은 실외뿐 아니라 실내에도 있음을 나타내고 있다.>10)의 $[^{18}F]F_2$를 얻었다. 결론: $^{18}O(p,n)^{18}F$ 핵반응을 이용하여 친전자성 방사성동위원소 $[^{18}F]F_2$를 생산하였다. 표적 챔버는 알루미늄으로 제작하였으며 본 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.었으나 움직임 보정 후 영상을 이용하여 비교한 경우, 결합능 변화가 선조체 영역에서 국한되어 나타나며 그 유의성이 움직임 보정 전에 비하여 낮음을 알 수 있었다. 결론: 뇌활성화 과제 수행시에 동반되는 피험자의 머리 움직임에 의하여 도파민 유리가 과대평가되었으며 이는 이 연구에서 제안한 영상정합을 이용한 움직임 보정기법에 의해서 개선되었다. 답이 없는 문제, 문제 만

  • PDF

Damage Characteristics of Korean Traditional Textiles by Nitrogen Dioxide (NO2) Concentrations (이산화질소(NO2) 농도에 따른 전통직물의 손상 특성)

  • Kim, Myoung Nam;Lim, Bo A;Kim, Seojin;Lee, Sun Myung
    • Journal of Conservation Science
    • /
    • v.29 no.3
    • /
    • pp.197-207
    • /
    • 2013
  • The gas acceleration test was conducted to identify the deterioration of Korean traditional textiles caused by $NO_2$. Total 20 specimens were prepared using 4 different materials (silk, cotton, ramie, hemp) after dyeing with 5 colors (undyed, red, yellow, blue, black). The specimens were exposed to 0.01, 0.1, 1, 10, 100, and 1000 ppm $NO_2$ gas in the test chamber at $20^{\circ}C$, 50% RH for 1 day. Optical, chemical, and physical evaluation was carried out after the exposure. In the case of Korean traditional textile, color difference increased at 1 ppm/day, $NO_3{^-}$ concentration, carbonyl and C-$NO_2$ functional group increased while pH decreased at 10 ppm/day and tensile strength weakened at 100 ppm/day. when it comes to undyed textile, alteration of color difference on silk and hemp cloth, $NO_3{^-}$ concentration and tensile strength on hemp cloth was remarkable. In addition, color difference on blue and yellow textile, $NO_3{^-}$ concentration increase of yellow textile and tensile strength decrease of hemp cloth & ramie cloth were significant. The results suggest that critical $NO_2$ concentration of optical, chemical, and physical damage on Korean traditional textiles are 1ppm/day, 10 ppm/day, 100 ppm/day respectively.

Experimental Study of Frost Heaving using Temperature Controlled Triaxial Cell (투명 온도제어형 삼축셀을 이용한 흙의 동상 실내실험)

  • Ryu, Byung-Hyun;Jin, Hyun-Woo;Lee, Jangguen
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.6
    • /
    • pp.23-31
    • /
    • 2016
  • Nowadays abnormal coldness happens frequently in Korea and frost heaving causes unexpected ground deformation which results in severe problems for structures such as roadway, railroad and cutoff slope. 'Frost heave' as one of the primary phenomenon is considered to be an important factor together with 'adfreeze bond-strength' and 'creep deformation' for structural design process in permafrost area. Therefore, the fundamental study for frost heave has to be preceded for design of geo-structures in cold region. While various experimental apparatuses have been developed, there still exist a certain level of limitation to evaluate the frost-heave characteristics as design parameters. There are no standard testing method and criteria for analyzing frost heaving in Korea because temperature controlled testing apparatuses including a freezing chamber are expensive. In this paper, a new standard freezing and thawing testing apparatus is introduced, which simulates various freezing and thawing conditions in a soil specimen by using a temperature controlled triaxial cell. Frost heaving tests were performed to assess the new testing apparatus and experimental procedure to evaluate frost heaving for soils is proposed.

Verification of Durability of Electromagnetic Metamaterial Absorber in Temperature Varying Environment for Its Application to Integrated Mast of Next-Generation Destroyer (차기구축함 통합마스트에 적용을 위한 전자기파 메타물질 흡수체의 온도 환경 내구성 검증)

  • Ra, Young-Eun;Kim, Yongjune;Jung, Hyun-June;Park, Pyoungwon;Jo, Jeongdai;Lee, Joonsik;Kim, Myungjoon;Jung, Joonkyo;Lee, Gun-Min;Lee, Jong-Hak;Lee, Hak-Joo
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.347-353
    • /
    • 2020
  • In this paper, the durability of an electromagnetic metamaterial absorber is verified in a temperature varying condition mimicking a maritime environment for the purpose of applying it to reduce the radar cross section of an integrated mast of the next-generation destroyer. To validate the durability, the reflectance of the electromagnetic metamaterial absorber was measured after storing it in a chamber that can control the temperature according to Procedure I of Method 501.7 included in MIL-STD-810H. Before and after the environmental test, both of the measured reflectances were retained less than -10 dB over the X band, that can guarantee the stealth functionality.

A study on EPB shield TBM face pressure prediction using machine learning algorithms (머신러닝 기법을 활용한 토압식 쉴드TBM 막장압 예측에 관한 연구)

  • Kwon, Kibeom;Choi, Hangseok;Oh, Ju-Young;Kim, Dongku
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.2
    • /
    • pp.217-230
    • /
    • 2022
  • The adequate control of TBM face pressure is of vital importance to maintain face stability by preventing face collapse and surface settlement. An EPB shield TBM excavates the ground by applying face pressure with the excavated soil in the pressure chamber. One of the challenges during the EPB shield TBM operation is the control of face pressure due to difficulty in managing the excavated soil. In this study, the face pressure of an EPB shield TBM was predicted using the geological and operational data acquired from a domestic TBM tunnel site. Four machine learning algorithms: KNN (K-Nearest Neighbors), SVM (Support Vector Machine), RF (Random Forest), and XGB (eXtreme Gradient Boosting) were applied to predict the face pressure. The model comparison results showed that the RF model yielded the lowest RMSE (Root Mean Square Error) value of 7.35 kPa. Therefore, the RF model was selected as the optimal machine learning algorithm. In addition, the feature importance of the RF model was analyzed to evaluate appropriately the influence of each feature on the face pressure. The water pressure indicated the highest influence, and the importance of the geological conditions was higher in general than that of the operation features in the considered site.

Blade Type Field Vs Probe for Evaluation of Soft Soils (연약지반 평가를 위한 블레이드 타입 현장 전단파 속도 프로브)

  • Yoon, Hyung-Koo;Lee, Chang-Ho;Eom, Yong-Hun;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.12
    • /
    • pp.33-42
    • /
    • 2007
  • The assessment of shear wave velocity($V_s$) in soft soils is extremely difficult due to the soil disturbances during sampling and field access. After a ring type field $V_s$ probe(FVP) has been developed, it has been applied at the southern coastal area of the Korean peninsular. This study presents the upgraded FVP "blade type FVP", which minimizes soil disturbance during penetration. Design concerns of the blade type FVP include the tip shape, soil disturbance, transducers, protection of the cables, and the electromagnetic coupling between transducers and cables. The cross-talking between cables is removed by grouping and extra grounding of the cables. The shear wave velocity of the FVP is simply calculated by using the travel distance and the first arrival time. The large calibration chamber tests are carried out to investigate the disturbance effect due to the penetration of FVP blade and the validity of the shear waves measured by the FVP. The blade type FVP is tested in soils up to 30m in depth. The shear wave velocity is measured every 10cm. This study suggests that the upgraded blade type FVP may be an effective device for measuring the shear wave velocity with minimized soil disturbance in the field.