• Title/Summary/Keyword: 채광창

Search Result 21, Processing Time 0.024 seconds

Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System (자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.635-642
    • /
    • 2020
  • The purpose of this study was to analysis the effects of shielding area of field configuration with changing of sensitivity and density on tube current (milliampere-seconds, mAs) and image quality in automatic exposure control (AEC) system. The equipment used a digital radiography device (Digital Diagnost, Philips, Netherlands), which has a integral type with an X-ray tube and an indirect digital detector. The AEC system conditions were consisted of 9 setting environments, that mode changing of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). The tube current evaluated automatically exposed mAs under 81 combination conditions crossed by AEC conditions in fixed at 40 kVp. The image quality evaluated the radiographic images that selected valid images by visual assessment the radiographic images of the self-produced conical pyramid phantom and then measured their signal to noise ratio (SNR). As a result, the maximum tube current was 60.0 mAs that automatically exposed conditions were the 100% of shielding area and the sensitivity of S200 and the density of +2.5. The minimum tube current was 0.9 mAs with non-shielding area and the sensitivity of S800 and the density of -2.5. When the shielded area 0% with the sensitivity of S200 and the density of +2.5, the maximum SNR was the highest as 25.2. But when the shielded area 25% with the sensitivity of S800 and the density of -2.5, the minimum SNR was the lowest as 4.7.

Sunlighting in atrium building (대공간의 채광계획 -아트리움을 중심으로 -)

  • 김정태
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.28 no.1
    • /
    • pp.10-15
    • /
    • 1999
  • 산업헉명 이후 유리와 철의 이용은 넓은 개구부를 지닌 대형공간을 지닌 건축을 가능케 하였고, 1970년대 이후 새로운 건축양식의 추구라는 시대적 요구는 아트리움의 건축적 응용을 확산하게 하였다. 아트리움은 다층건물의 유리로 덮힌 대형공간으로 건물의 중심적이고 내부적인 공공의 공간이다. 대형공간으로서 아트리움의 가장 큰 특징은 넓은 채광창을 통해 실내로 유입되는 태양광에 있다. 넓은 채광창은 사람들에게 시각적인 개방감을 제공하며, 또한 많은 채광량으로 식재에 의한 조경이 가능해 외부공간과 같은 분위기를 연출하면서도 비·바람·추위 등으로부터 보호되는 쾌적한 온열환경을 제공하고 있다.

  • PDF

The Effect of indoor illuminance depends on direction of the side windows lighting (측창채광의 방향에 따른 실내조도의 영향)

  • Cho, Shee-Man;Kim, Won-Joong;Jang, Woo-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.253-260
    • /
    • 2004
  • 실내의 조명은 자연채광방식과 인공조명으로 나누어지는데 자연형 채광방식에서도 측창채광과 천창채광, 정 측창채광 그리고 반사 채광방식이 있다. 측창채광은 벽면에 대하여 일반적으로 연직인 창에 의한 채광을 말한다. 측창채광의 방향에 따라 실내조도는 영향을 많이 받는다. 따라서 본 연구는 측창채광의 동서남북의 방향에 따라 봄, 여름, 가을, 겨울의 계절에 따라 아침, 점심, 저녁시간대에 따라 변화되는 실내조도를 알아보았다. 실험방법은, 조명시뮬레이션 프로그램인 Lightscape V3.2를 사용하여 교실공간의 치수와 작업면의 높이를 가로 5.8[m], 세로 10.8[m], 높이 3[m], 작업면의 높이 0.75[m]로 정하였고, 각 시설물의 반사율[p]은 벽 80%, 창문 12%, 출입문 13%, 바닥 20%, 천장 85%로 지정하였으며 창문의 투과율은 88%로 설정하였다. 본 연구에서 측정하고자 하는 변수 값은 계절은 여름을 6월20일, 겨울은 1월20일 기준으로 하고 시간대는 09시, 13시, 18시로 하였으며 창측방위는 동, 서, 남, 북으로 정하였으며 계절과 시간은 가장 차이가 많이 나는 값을 선택하였다. 결론으로 창이 남쪽일 때 평균조도가 9,100[lx]로 가장 높았고, 시간별로는 점심에 19,590[lx]로 조도가 가장 높은 것을 알 수 있었고 조도 균제도는 창이 동쪽일 때 겨울에 가장 높았다. 창이 북쪽일 때는 여름이 겨울보다 평균조도가 약간 높았고, 시간별로는 아침에 조도가 약간 높은 것을 알 수 있었고 전체적으로 북쪽 창에서 실내조도가 현저하게 떨어지는 것을 알 수 있었다. 이와 같은 결과로 측창의 브라인드를 현재 사용하고 있는 수직 브라인드 대신에 수평 브라인드를 사용하여 주광의 범위를 넓게 조절하여 사용하게 하고, 점등제어를 현재 측창면과 수직으로 되어있는 배열을 수평으로 한다면 자연채광의 효과를 배가 할 수 있으리라고 사료된다. 미백 전, 미백후, 재광화 후 미세경도 변화 양상이 미백을 하지 않은 대조군과 차이를 보이지 않았으며 (p > 0.05) 미백 전과 미백 후의 미세경도의 차이 미백후와 재광화 후의 미세경도의 차이도 유의할 만한 차이가 없었다 (p > 0.05). 따라서 시중에 판매되고 있는 whitening strip과 미백 젤은 14일 동안의 통상적인 미백과정 동안 법랑질의 미세경도에 영향을 미치지 않는 것으로 사료된다.able pitch와 helical angle보다는 근본적으로 radial land가 screw-in effect의 예방에 더 큰 역할을 하는 것으로 추정될 수 있다 따라서 NiTi file의 사용 경험이 없는 초심자의 경우 근단부 폭경의 유지능력이 좋은 ProFile$^{(R)}$의 사용이 추천된다.)되었다.였으나 강남콩군 외에는 단백질의 소화 흡수율 및 효율은 크게 향상되지 않아 단백질의 소화 흡수율을 떨어뜨리는 요인에 관한 연구가 집중적 으로 이루어져야 하리라고 생각된다.면 바로 위 지점의 풍속을 측정하였다. 각 Seeding 물질에 대해 팬을 켜지 않았을 때, 즉 바람의 영향이 없을 때 측정한 표면유속을 바람의 세기가 변한 경우의 기준 표면유속으로 이용하였다. 본 연구의 결과 비중이 0.01 내외인 Ecofoam과 white polystyrene에 비해 비중이 0.92인 black polypropylene은 대부분이 물속에 잠겨 있어 흐름과 거의 일치하여 움직임을 알 수 있었다. 또한 흐름의 평균유속이 0.165 m/s의 저유속에서 바람이 tracers에 미치는 영향이 평균유속 0.558m/s인 경우보다 커서, 바람의 세기의 증가에 따라 표면유속 측정값이 급속히 감소되었다. 흐름의 평균유속이 큰 경우에는 바람이 tracer에 마치는 영향이 현격히 줄어듬을 보이고 있다. 결론적으로 유속이 증가함에 따라 바람의 영향은 감소하나, 바

  • PDF

A Performance Evaluation of Solar Mirror Sunlighting Systems (반사거울형 태양광 채광시스템의 성능 평가)

  • Lee, Beom-Seok;Kim, Jeong-Tai
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.30-37
    • /
    • 2005
  • 태양광 채광시스템은 자연광의 유입이 어려운 공간에 주광을 유입하기 위하여 개발된 장치로써 에너지를 절약하고 인간의 쾌적성을 향상시키는 등 지속가능한 건축을 위해 도입 및 확대가 크게 기대 되는 장치이다. 이에 본 연구는 기존에 본 연구실에서 개발된 시스템의 문제점을 보완하고 개선하여 건축물 적용시의 채광성능을 평가하는데 연구목적이 있다. 본 시스템의 설치는 2004년 10월 25일 (주) 동아산전과의 공동작업으로 설치되었으며, 수원에 있는 K대학 공과대학 5층 옥상 파라펫에 설치하였다. 평가실험은 2005년 4월 5일 9시30분부터 15시30분까지 청천공 상태에서 실시하였고, 총32개의 측정점을 선정하여 주광조도비로 채광성능을 평가하였다. 실험결과, 반사거울을 설치 시 창이 있을 경우 실내의 주광조도비는 평균 20.3[%] 상승하였고 창을 제거할 경우 실내의 주광조도비는 평균 38.2[%]정도 상승하여 채광학적으로 유효한 것으로 분석되었다. 따라서 본 시스템은 건축물의 실내 및 옥외의 음영진 곳에서 유용하게 사용될 수 있음이 입증되었다.

  • PDF

A Study on Glazing Ratio of Certified Green Building Apartment (국내 친환경 아파트의 채광창 면적비에 관한 연구)

  • Kim, Sang-Bum;Park, Jong-Hoon;Yang, Byoung-E
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.95-100
    • /
    • 2010
  • Buildings receive solar radiation through windows and the solar radiation helps to save heating energy in winter. Therefore the bigger the glazing ratio is, the larger the amount of solar radiation we can receive. In this study we analysed the glazing ratio of Certified Green Building Apartments. And we verified whether the glazing ratio reflects energy saving through accepting solar radiation with correlation analysis. For glazing ratio analysis, we selected 116 apartment buildings of 19 apartment complexes that certified in 2008-2009 and took pictures of outside windows of the buildings. After that, we analysed the building's glazing ratio with 4 azimuth and checked distinction of the glazing ratio between 6 coupled azimuths. And we analysed the correlation between importance order of azimuth for energy saving and the glazing ratio change with the azimuth. The analysis showed that the glazing ratio does not reflect energy saving through accepting solar radiation.

A Design and Performance Evaluation of Differentiated Daylight-Glazing Systems (가변 투과시스템의 광제어 특성을 고려한 통합 채광시스템의 적용성 평가에 관한 연구)

  • Kim, Gon;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.13-22
    • /
    • 2005
  • This research aimed to generate two points of daylighting application as follows: 1) providing daylight performance data with a variety of glazing materials for a large window and 2) designing and evaluating an experimental type of differentiated window. For this purpose, we compared the daylight and distribution performance of new defined type of window configuration to the conventional window counterpart with a variety of glazing materials. The comparison was made for a deep, south-facing perimeter zone with large window, without any interior obstruction. The conventional window is the base single homogeneous glass pane, where as the differentiated window uses of two different glazings; an upper daylight glazing with high visible transmission and lower view window with lower transmittal glass. The daylight performance data was translated into a ratio between outdoor illuminance and the interiors. The simulated analysis of the conventional window indicates that the interior light levels have been changed proportionally dependent on the transmittance of the applied glass. The comparison of daylight distribution analysis showed that the differentiated window has lots of photometric advantage by the optical function of upper daylight window. In particular, the contribution of higher daylight window into deep rear space must be stressed for daylighting application.

Daylighting Performance of Interior Space with Differentiated Glazing Systems (가변 유리투과체로 구성된 실 내공간의 채광성능평가)

  • Jeong, In-Young;Kim, Jeong-Tai
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.63-68
    • /
    • 2004
  • 본 연구는 우리나라 유리건축에서 적용되고 있는 유리투과체를 조사하여 투과율이 다른 4종류 즉, 투명유리, 색유리, 파스텔유리, 로이유리를 선정하여 복층유리로 제작하였다. 투과체에 따른 실내공간의 채광성능평가를 위하여 축소모형을 1/10으로 제작하였으며, 투과체의 구성을 일반형과 이중분할형으로 구성하여 기준실과 실험실에 설치하였다. 또한, 채광성능평가시 IEA모니터링 프로토콜을 적용하여 작업면, 벽면, 천정면에 대하여 조도를 외부조도와 동시에 측정하였고, 본 논문에서는 작업면에 대한 채광성능평가를 중심으로 분석하였다. 평가지표로서 주광조도비를 사용하였으며, 일반형과 이중분할형에 대한 가변 유리투과체를 변화시켰을 경우 투과율에 따른 실내공간의 채광성능을 평가하였다. 가변 유리투과체로 구성된 실내공간의 채광성능평가는 다음과 같이 분석되었다. 첫째, 실내공간에 일반형을 적용하여 서로 다른 투광성능을 가진 유리투과체가 적용된 경우 외부조도에 대한 내부조도 비율은 투과율이 증가할수록 일정하게 증가하는 것으로 나타났다. 이는 투과체가 갖는 투과성능의 영향으로 판단된다. 둘째, 일반형에 비해 이중분할형은 채광창으로 유입되는 채광학적 기여가 증가하여 실 전체의 조도를 증가시키며 특히, 실 중간부와 후면부의 경우 채광적 잠재력이 증대되어 실의 쾌적함과 시 환경적 질이 증대될 것으로 사료된다. 현재 유리건축물에 많이 적용되고 있는 저 투과체에 이중분할형을 적용할 경우 채광학적으로 많은 효과가 있을 것으로 기대된다.

  • PDF

Design of Daylighting Aperture Using Daylight Factor Method and its Evaluation by Distribution of Sky Component (Daylight Factor Method를 이용한 채광창의 설계)

  • 지철근;권영혜
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.3 no.1
    • /
    • pp.58-63
    • /
    • 1989
  • 이등분한 실의 주광율(Daylight Factor)의 비를 규제도의 지수로서 Lumen Method와 같이 정하고, 이를 만족하는 실의 깊이를 검토한 후, 설계 평균 주광율을 만족하는 창의 면적을 구하였다. 본 논문에서 제안한 창의 면적 자체가 다른 벽면의 면적 변화에 영향을 주고 있음을 고려하지 않은 종래의 방법을 개선하였다. 이후 주광율 요소 중 가장 지배적인 양인 운천공으로부터 입사하는 성분(SCo: Sky Component from overcast Sky)의 분포를 창의 위치와 형태를 변화시켜 조사, 평가하였다.

  • PDF

A STUDY ON COMPUTING ILLUMINANCE DISTRIBUTION OF THEINTERIOR WHICH HAS DAYLIGHT APERTURE BY MONTE CARLO SIMULATION (몬테카를로 시뮬레이션을 이용한 채광창을 가지는 실내면의 조도계산에 관한 연구)

  • 송민호;김석환;지철근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.23-27
    • /
    • 1991
  • The Monte Carlo Simulation has been used widely in physics for computing flux transfer, pricipally in applications where direct solution of analytical equations is very difficult. But it seldom has been applied in determining interior lighting. This article summarizes the Method, and deals with numerical results of illuminance distribution. This Method considers daylight as well as artificial light sources.

  • PDF