• Title/Summary/Keyword: 착화실험

Search Result 194, Processing Time 0.024 seconds

The Treatment of Heavy Metal-cyanide Complexes Wastewater by Zn$^{+2}$/Fe$^{+2}$ Ion and Coprecipitation in Practical Plant (II) (아연백법 및 공침공정을 이용한 복합 중금속-시안착염 폐수의 현장처리(II))

  • Lee, Jong-Cheul;Lee, Young-Man;Kang, Ik-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.5
    • /
    • pp.524-533
    • /
    • 2008
  • Industrial wastewater generated in the electroplating and metal finishing industries typically contain toxic free and complex metal cyanide with various heavy metals. Alkaline chlorination, the normal treatment method destroys only free cyanide, not complex metal cyanide. A novel treatment method has been developed which destroys both free and complex metal cyanide as compared with Practical Plant(I). Prior to the removal of complex metal cyanide by Fe/Zn coprecipitation and removal of others(Cu, Ni), Chromium is reduced from the hexavalent to the trivalent form by Sodium bisulfite(NaHSO$_3$), followed by alkaline-chlorination for the cyanide destruction. The maximum removal efficiency of chromium by reduction was found to be 99.92% under pH 2.0, ORP 250 mV for 0.5 hours. The removal efficiency of complex metal cyanide was max. 98.24%(residual CN: 4.50 mg/L) in pH 9.5, 240 rpm with 3.0 $\times$ 10$^{-4}$ mol of FeSO$_4$/ZnCl$_2$ for 0.5 hours. The removal efficiency of Cu, Ni using both hydroxide and sulfide precipitation was found to be max. 99.9% as Cu in 3.0 mol of Na$_2$S and 93.86% as Ni in 4.0 mol of Na$_2$S under pH 9.0$\sim$10.0, 240 rpm for 0.5 hours. The concentration of residual CN by alkaline-chlorination was 0.21 mg/L(removal efficiencies: 95.33%) under the following conditions; 1st Oxidation : pH 10.0, ORP 350 mV, reaction time 0.5 hours, 2nd Oxidation : pH 8.0, ORP 650 mV, reaction time 0.5 hours. It is important to note that the removal of free and complex metal cyanide from the electroplating wastewater should be employed by chromium reduction, Fe/Zn coprecipitation and, sulfide precipitation, followed by alkaline-chlorination for the Korean permissible limit of wastewater discharge, where the better results could be found as compared to the preceding paper as indicated in practical treatment(I).

Experimental Study on the Effects of Combustion Products on the Human Body and Suggestion of Law Revision (흡음재의 연소 생성물이 인체에 미치는 영향에 대한 실험적 연구 및 법률 개정 제언)

  • Kang, Jung Ki;Choi, Don Mook
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.28-34
    • /
    • 2019
  • Regardless of the ignition source, the main factors affecting the spread of flames to the human body are combustibles. The sound absorption material, which is the finishing material used in music institutes and karaoke rooms, consists of polyurethane that generates a large amount of toxic gas with a high amount of combustion gases during a fire. Still, the current law does not require the use of impregnated finishing materials for tutoring services with less than 100 users. In this study, the rate of flame diffusion was measured using the MultiRaelite composite gas measuring instrument (target substance VOC, HCHO, SO2, CO2, CO, HCN, and NO2) for the collection of sound-absorbing materials installed in the actual music academy. The results showed that the toxic gas found in this experiment exceeded the allowable concentration of TWA (Time Weighted Average) and STEL (Short Term Exposure Limit). In addition, a comparative combustion test of the general sound absorber and non-combustion sound absorbing materials on the market showed wide differences in ignition and diffusion. Therefore, based on the results of the experiment, private institutes with less than 100 users should be mandated to use non-combustion sound absorbing materials.

Determination of Copper Ion with 2-Mercaptobenzimidazol Immobilized on Surfactant-Coated Alumina (계면활성제를 코팅한 알루미나에 부동화한 2-Mercaptobenzimidazol을 이용한 구리이온의 정량)

  • Absalan, G.;Goudi, A.Aghaei
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.2
    • /
    • pp.141-146
    • /
    • 2007
  • The present paper describes a procedure for separation, preconcentration and determination of trace amount of copper in natural water samples by using 2-mercaptobenzimidazol as the complexing agent. The proposed method is based on the surfactant aggregation formed on γ-alumina by mixing sodium dodecyl sulfate and γ-alumina in water; 2-mercaptobenzimidazol was incorporated into inner hydrophobic part of produced ad-micelles in acidic media to produce an assemble suitable for preconcentration and determination of copper ion. Optimum experimental conditions for adsorption of μg/ml levels of copper ions from aqueous solution by the adsorbent have been reported. The copper ions were quantitively adsorbed by the sorbent over the pH range of 7.1-8.0 and were quantitatively desorbed afterward by using sulfosalycilic acid as the eluent. The determination of copper was not interfered in the presence of common metal ions. The procedure was applied for analysis of river water sample. Relative standard deviation was found to be 4.91%.

Solvent Extraction of Cu(II) by 2,4-Heptadione in Chloroform (2, 4-Heptadione에 의한 Cu(II)의 용매추출특성)

  • Shin, Jeong-Ho;Jeong, Kap-Seop;Lee, Sang-Hoon;Park, Sang-Wook;Park, Dae-Weon
    • Applied Chemistry for Engineering
    • /
    • v.4 no.4
    • /
    • pp.672-682
    • /
    • 1993
  • 2, 4-Heptadione(abbreviated to 24HTD) was synthesized from methylpropyl ketone and ethyl acetate with sodium amide, and the equilibrium and the kinetic characteristics of copper extraction by 24HTD-chloroform were investigated. Equilibrium constants such as the dissociation constant and the distribution coefficient of 24HTD and the stability constant of the 24HTD-Cu chelate were evaluated from the spectrophotometry, and the overall equilibrium constant of the extraction was also determined. The extracted species of the 24HTD-Cu chelate was found to be $CuR_2$ and the initial rate of the extraction of coupper by 24HTD in chloroform was expressed by $R_0=k[\bar{HR}]([Cu^{2+}]/[H^+])^{0.5}$.

  • PDF

An Experimental Study on the Fire Risk of a Firewood Boiler (화목보일러 화재위험성에 관한 실험적 연구)

  • Lee, Sung-Ryong
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.37-42
    • /
    • 2015
  • In this study, experiments were carried out to evaluate the fire risk of a firewood boiler, which is mainly used as a winter heating apparatus in rural areas. The ambient temperatures of the combustion chamber and the duct were measured. The fire risk of tar inside the duct was also investigated. The temperature decreased less than $40^{\circ}C$ in the region more than 40 cm from the combustion chamber. Fire- flakes were scattered in the range of less than 60 cm from the combustion chamber. The temperature inside the rose to above $600^{\circ}C$. At 2 m from the boiler body, the temperature inside the duct was increased to about $420^{\circ}C$. The ignition temperature of tar was about $398^{\circ}C$. The temperatures of the boiler and duct surface were above $300^{\circ}C$. Combustible material ignited when it contacted the boiler surface or duct surface.

Investigation on the Field Application of the Flammable Limit of Vaporized Gasoline (휘발유 유증기 폭발범위의 현장 적용성에 관한 연구)

  • Kang, Jung Ki;You, Woo Jun;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.73-80
    • /
    • 2015
  • In this study, the conditions of explosion range of gasoline, which is used as combustion improver, are experimentally analyzed. Two types of compartment, which is the small scale ($0.5m{\times}0.5m{\times}1.0m$) and the middle scale ($0.5m{\times}0.5m{\times}1.0m$), are mocked-up and the auto-control systems are installed in order to measure the vaporized gasoline and the moment of pressure, ignition time and maximum pressure. In case the maximum flammable limit of gasoline is up to 22.4 Vol% not the generalized range of 1.4~7.6 Vol% when nichrome igniter of $700^{\circ}C$ is used. These results can be appled to the analytical prediction of fire identification in the field of explosion.

A Study on the Mass Transfer and Metal Extraction by use of Hydrophobic Membrane (소수성막을 이용한 금속추출 및 물질전달에 관한 연구)

  • Lee, Ryong-Jin;Kim, Young-Il;Park, Dong-Won
    • Applied Chemistry for Engineering
    • /
    • v.9 no.7
    • /
    • pp.1036-1042
    • /
    • 1998
  • It was investigated that the extraction of Cr(VI) from aqueous solution into the organic TDA and the stripping(back extraction) of Cr(VI) from the Cr(VI)-TDA complex into NaOH aqueous solution by hydrophobic hollow fiber membrane. It was found that the mass transfer rates of stripping process were smaller than those of the extraction process. This result was expected that membrane resistance, neglected in the extraction process, acts on the stripping process when organic phase flow in the tube side of the hydrophobic membrane. Hollow fiber modules were made by potting the desired number(60, 100, 150, 300fibers). We also examined the effect of flow rates of aqueous and organic phase on the mass transfer rate in the membrane modules. From these experiments, we identified for the extraction process by using hydrophobic membrane, the effect of flow rate of aqueous phase on the mass transfer rate was significant, but that of organic phase was negligible one. In the stripping process, however, mass transfer rate depend neither flow rate of aqueous(stripping solution) phase nor that of organic(Cr-TDA complex) phase.

  • PDF

Studies on the Adsorption and Desorption Characteristics of Cu Ion Using Manganese Nodule as Adsorbent (Mn단괴를 흡착제로 한 Cu이온의 흡착 및 탈착 특성)

  • Kim, Jin-Wha;Kim, Dong-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.3
    • /
    • pp.547-556
    • /
    • 2000
  • A study have been conducted for the adsorption and desorption characteristics of Cu ion using manganese nodule as adsorbent. For 100 ppm Cu ion solution, the adsorbed amount of Cu ion was more than 90 % at equilibrium state. Adsorption was equilibrated in 42 hours the adsorption reaction was shown to be first order reaction. For the desorption reaction of Cu ion in the region of solution pH 3.5~9.5, the desorption was completed in the acidic region, but it has been decreased as the pH was raised. Also, the desorption rate was higher in the acidic region compared with alkaline region. The desorbed amount was decreased as the reaction temperature increased, therefore, the desorption reaction was thought to be exothermic. Also, several thermodynamic properties were calculated based on experimental results and compared with theoretically driven values. To see the effect of complexing agent on the desorption of Cu ion, EDTA was introduced and the des orbed amount increased in the presence of EDTA.

  • PDF

Diesel Combustion Strategies Effect on Exhaust Emissions and Hydrocarbon Species (디젤 연소 전략에 따른 배기가스 및 탄화수소 종 분석)

  • Han, Man-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.759-765
    • /
    • 2012
  • This study investigates the effect of diesel combustion strategies on exhaust emissions and hydrocarbon species emissions for a 1.7 L common rail direct injection diesel engine at 1500 rpm and 3.9 bar BMEP. The first strategy is a method to adopt no EGR with a split injection composed of pilot and main injection (split injection). The second is to adopt a moderate EGR rate with main injection only (single-1). The third is to use a high level of EGR and main injection with rail pressure increase, $i.e.$ low-temperature diesel combustion (single-2). Split injection and single-1 showed a renowned phenomenon of a PM-NOx trade-off, whereas single-2 was observed of a PM-NOx trade-off to reduce PM and NOx simultaneously. HC speciation results show that the split injection produced the least amount of HC species, regardless of the carbon number bin, followed by single-1 and single-2. The ratios of methane, acetylene, and CO to THC increased as a combustion A/F ratio is richer due to reduced oxygen content in the vicinity of the combustion zone, thus enhancing pyrolysis.

Effect of Light Intensity on Growth and Flowering of Several Korean Native Wild Flower Plants (자생화훼식물의 광도차에 따른 생육반응)

  • Lee, Jong Suk
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.4 no.1
    • /
    • pp.52-56
    • /
    • 2001
  • Experiment was performed to investigate the effect of light intensity on growth and flowering status of Korean native Dianthus superbus var. longicalycinus, Sedum middendorifianum, Hemerocallis aurantiaca, Iris ensata var. spontanea and Aquilegia buergeriana var. oxysepola for effective landscaping. Number of floret and flower stalk per a plant were markedly increased under full sun(about 100,000lux), and decreased with decreasing light intensity in all tested plants. This result indicate that it will be cultivated in the open for promote landscaping values. However, leaf area and plant height were more increased under half sun(22,000lux) than open(100,000lux) or shade(7,700lux) in all plants except Sedum middendorifianum. Especially, Hemerocallis aurantiaca had same number of shoot and leaf size, even if planted under shade condition to show a wide adaptation to various light intensities.

  • PDF