• Title/Summary/Keyword: 착화수

Search Result 309, Processing Time 0.023 seconds

A Combustion Characteristic Analysis of Sandwich Panel Core Using Radiation Heat Flux (복사열을 이용한 샌드위치 패널 심재의 연소특성 분석)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.25-31
    • /
    • 2007
  • The combustion characteristics and combustion heat of sandwich panel cores were analysed using variable external irradiation level. The characteristics such as ignition time, critical heat flux, ignition temperature and surface temperature profile were measured. Fuel samples were exposed to incident heat fluxes from 15 to $50\;kW/m^2$. For the measurement of various combustion characteristics, the size of specimen was $100\;mm\;{\times}\;100\;mm\;{\times}\;50\;mm$ and the samples were 3 different kinds. As results, Type B showed the best characteristics in measurement of combustion heat and ignition temperature and Type C showd the best characteristics in critical heat flux and surface temperature profile than that of the other two. In conclusion, we knew that Type C had the best performance in fire safety from all data of this study.

Using Two-Dimensional Chemiluminescence Images to Study Inhomogeneity in Mixture Gas in the Combustion Chamber for HCCI Combustion (이차원발광화상계측에 의한 예혼합압축자기착화연소의 연소실내 혼합기의 불균질성에 관한 연구)

  • Lim, Ock-Taeck;Iida, Norimasa
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1043-1050
    • /
    • 2010
  • Fuel stratification and thermal stratification occur in the HCCI combustion chamber on a microscopic scale. They affect the ignition and combustion processes. In this study, the effect of the inhomogeneity in the mixture gas on the HCCI combustion process was investigated. Two-dimensional chemiluminescence images were captured using a framing camera to evaluate the flame structure. DME was used as the test fuel. First, the effect of inhomogeneity in the fuel distribution in the premixture was investigated for the four-stroke optically accessible engine. Then, by comparing the combustion of the homogeneous mixture in the rapid compression machine, which does not contain any residual gas, with the combustion in the four-stroke engine, the effect of inhomogeneity in temperature due to the residual gas was analyzed. The results showed that a time lag appears spatially in combustion under inhomogeneous conditions in the four-stroke engine. The spatial variation in the combustion without the residual gas in the rapid compression machine is less than that in the combustion in the four-stroke engine.

Development of Metal Compound Explosives Using KIO4 and TiH2 (KIO4와 TiH2를 이용한 금속복합화약 개발)

  • Ahn, Gilhwan;Kim, Sangbaek;Kim, Junhyung;Ryu, Byungtae
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.1
    • /
    • pp.58-63
    • /
    • 2020
  • THPP is a type of metallic complex explosive used in initiators, consisting of TiH2 and KClO4. In this case KClO4 includes ClO4- which is a harmful substance that may cause thyroid dysfunction or tumors. In this study KIO4 is applied to a new type of environmentally friendly explosive as a substitute to the conventional KClO4. Tests were carried out to see if KIO4 can be made a successful replacement for KClO4.

Ignition of ceiling insulation depending on working condition of Sprinkler head in underground parking lot fire (지하주차장 화재 시 스프링클러헤드 작동 여부에 따른 천장 위 단열재의 발화 여부)

  • Kim, Seo-Young;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.461-468
    • /
    • 2022
  • This study is focused on the ignition of ceiling insulation depending on working condition of Sprinkler head in underground parking lot fire. When temperature changes of same point were measured depending on sprinkler's working condition, in Scenario 1, inner temperature at border of spray applied material(SP-2) of ceiling part near the fire and ceiling insulation(blowing polystyrene) was 658.27℃ and its which inner maximum temperature is higher than 427℃ which is the ignition point of ceiling insulation(blowing polistyrene), so it was observed that flame is ignited on the ceiling insulation and spread fire. In scenario 2, Inner fire temperature at border of spray applied material(SP-2) and ceiling insulation(blowing polystyrene) near the fire was 53.10℃ and it was lower than ignition point so it was observed that flame was not ignated on the ceiling insulation. As a result, it was foreseen that possibility of ignition on the ceiling insulation depending on working condition of sprinkler.

핵융합로 증식재용 $\gamma$-$LiAlO_2$분말 합성

  • 박지연;문영태;김원주;오석진;김영석;국일현
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.747-752
    • /
    • 1995
  • 핵융합로 증식재용 ${\gamma}$-LiAlO$_2$ 분말을 자발착화 연소반응법을 적용하여 합성하였다. LiAlO$_2$분말을 합성하는데 이 방법을 적용하면 다른 분말 합성법과 달리 짧은 시간 내에 미세한 ${\gamma}$상을 쉽게 형성할 수 있었다. 최적의 ${\gamma}$-LiAlO$_2$ 분말을 합성하려면 구연산과 우레아의 혼합연료가 가장 적절하다고 판단되며, 이 연료로 합성된 ${\gamma}$-LiAlO$_2$ 분말을 24시간 볼분쇄하면 비표면적 값이 15.8 m$^2$/g인 미세한 분말을 얻을 수 있었다.

  • PDF

분진폭발의 예방대책

  • 목연수
    • Bulletin of the Korean Institute for Industrial Safety
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 2001
  • 생활양식의 변화와 정밀산업의 발달로 고체 덩어리나 입자를 분쇄하여 분체의 형태로 사용, 취급, 저장하는 빈도가 증가하고 있으며, 이들 중 분체가 가연성인 경우에는 공기 또는 산소와의 접촉면적이 커서 비교적 쉽게 착화할 뿐 아니라 급격한 연소를 일으켜 화재·폭발의 위험성이 항상 존재하고 있다고 할 수 있다. 이와 같은 위험성을 가지는 가연성 분진에는 소맥분, 전분, 사탕 등의 식료품을 비롯하여 가축용 사료분진, 각종금속, 플라스틱 및 화학제품 등의 가공용 분진, 약품, 연료로 사용되는 석탄 뿐 아니라 섬유부스러기, 연마시의 분진 등을 들 수 있다. 특히 최근에는 신소재로서의 기능성 물질과 전자재료의 개발이 활발하게 진행되어 이 분야에서 분체를 취급하는 공정도 증가하고 있는 실정이다.(중략)

  • PDF

A Study on Analysis of Characteristics Combustion of Floor Covering Materials (바닥내장재의 연소특성 분석에 관한 연구)

  • Park, Young-Ju;Lee, Hae-Pyeong;Kim, Hyun-Ju
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.77-83
    • /
    • 2010
  • In this study, we analyzed the combustion characteristics of four different floor covering materials(wood, monorium, laminatedpaper, and varnish-laminated paper) with regard to their ignitibility, thermal characteristics and flame retardancy by using an ignition temperature tester, a dual cone calorimeter, a thermogravimetric analyzer and limited oxygen index, for their fire risk assessment. According to the result, monorium had the lowest ignition temperature of $325^{\circ}C$ and the laminated paper and the varnish-laminated paper promptly ignited before 7s. Further, the wood showed the largest total heat release of $100MJ/m^2$, and the varnish-laminated paper showed the highest peak heat release rate. From the thermogravimetric analysis, it was shown that all specimens underwent rapid weight loss at $300{\sim}400^{\circ}C$. The limit oxygen indices of the laminated paper and the varnish-laminated paper were in the range of 20~21%, while it was 34% for wood. This study enabled us to confirm that wood, laminated paper and varnish-laminated paper have a relatively short ignition time and are easy to burn but they all have low heat release. In contrast, wood showed the lowest fire risk among them and had excellent flame retardancy but with high heat release.

Investigation of Eu(Ⅲ)-Polyfunctional Organic Acid Complexes by Eu(Ⅲ) Luminescence Spectroscopy (Eu(Ⅲ) 발광 분광법을 이용한 Eu(Ⅲ)과 다가 유기산 착물 연구)

  • Lee, Byoung Ho;Shin, Hyun Sang;Moon, HiChung
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.1
    • /
    • pp.59-64
    • /
    • 1996
  • The 7F0→5D0excitation spectra of Eu(Ⅲ) complexed with polyfunctional monocarboxylic acid(glycolic acid, glycine and thioglycolic acid) containing a terminal O, N and S neutral donors and propionic acid were investigated using Eu(Ⅲ) luminescence spectroscopy. In the excitation spectra of Eu(Ⅲ)-propionate system, the stepwise appearance of the peaks was observed at 579.0, 579.2 and 579.5 nm with increasing in the ligand-to-metal ratio, which correspond to the formation of Eu(propionate)2+, Eu(propionate)2+ and Eu(propionate)3 species. Three maximum peaks were also obtained for Eu(Ⅲ)-glycolate, Eu(Ⅲ)-glycinate and Eu(Ⅲ)-thioglycolate systems and were found to be quite similar to those of Eu(Ⅲ)-propionate system. The q values (number of coordinated water molecules of Eu(Ⅲ) ion) obtained from the luminescence decay constants of Eu(Ⅲ)-glycolate and Eu(Ⅲ)-thioglycolate were 7.0 and 7.1, and compare well with 7.3 for Eu(Ⅲ)-propionate: Each ligand units replace around two coordinated water molecules. These results show that the polyfunctional monocarboxylates behaves like the propionate for Eu(Ⅲ) ion coordination.

  • PDF

Fire Spreading Prevention of Straw-roofing House in Folk Village by Flame Resistant Treatment (민속마을 초가집의 방염에 의한 화재확산방지)

  • Park, Ho-Chun;Kim, Hwang-Jin;Lee, Seung-Hyun;Lee, Sung-Eun;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.52-57
    • /
    • 2010
  • Fire protection countermeasure were considered on the straw thatched roof and wooden structure. For the fire resistant treatment, rice straw was soaked in the fire resistant liquid with different soaking time. After treatment, some rice straw sample was washed with water then the rice straws were tested to check the fire resistance performance. And the wood was soaked in the fire resistant liquid at an atmospheric pressure, vacuum-pressure condition and painted with brush on the surface. To analyse the fire resistant performance of rice straw, ignition delay time was measured under the radiant heat flux of cone heater. And the fire resistant performance of wood samples were tested with 45 degree fire resistant test apparatus and cone heater. Based on the cone heater test, the rice straw which most easily ignitable material shows the longer ignition delay time than not treated ones and even in the water washed straw show a longer ignition delay time than not treated ones. And fire resistant treated woods of vacuum-pressure treated sample showed the most excellent performance on fire resistance. And the fire resistant treated by brush and soaking showed a longer ignition delay time than not treated ones. From this experiment, it was found that a fire resistant treatment of rice straw and wood of the house can be protected from the fire spread.

Effect of Cutting Time on Growth and Flowering of Double Flowered Hydrangea serrata for. acuminata (겹꽃산수국의 삽목시기가 개화에 미치는 영향)

  • Lee, Jong Suk;Kim, Hyun Jin
    • FLOWER RESEARCH JOURNAL
    • /
    • v.18 no.1
    • /
    • pp.33-37
    • /
    • 2010
  • Effects of cutting time of double flowered Hydragea serrata for. acuminata native to Korea on flowering and growth of following year were investigated in order to develop as a pot plant. Cuttings were carried out every 10th day from April to September in 2008. The cuttings were directly placed in 15 cm diameter pots. Longest plant was obtained from May cuttings and their average heights were 31.7 cm, and followed by April and July cuttings. Plant heights of August and September cuttings were 23.6 cm and 22.0 cm, respectively. In contrast, growth and height of June cutting were abnormally small. Leaf length, leaf width and petiole length of August and September cutting were reduced, but numbers of leaves were not changed. Average flower cluster numbers of May cuttings were 4 flower clusters, and July, August and September cuttings were 3 clusters while only 1 flower cluster per a plant was obtained during June. Biggest diameter of flower crown was observed from May cuttings and the size was 10.3 cm diameter; however, smaller flower crown size was observed after July cuttings. The best overall flower appearance was observed from May cuttings, and the worst was June cuttings. Even though plant height of August and September cuttings were reduced, flowering aspect and ornamental value were normal, but blooming times were retarded according to late cutting time.