• Title/Summary/Keyword: 착의 평가

Search Result 186, Processing Time 0.026 seconds

Physicochemical Properties and Antioxidative Activities of Mixed Citrus and Carrot Juice (감귤당근 혼합주스의 이화학적 특성 및 항산화효과)

  • Oh, You-Sung;Hwang, Joon-Ho;Oh, Hyun-Joeng;Lim, Sang-Bin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.5
    • /
    • pp.598-604
    • /
    • 2012
  • Four types of mixed citrus and carrot juice (CCJ) were prepared with citrus-pressed juice and cake, and carrot-pressed juice. Their physicochemical properties and antioxidative activities were investigated. The four types of juices were created using different ratios of citrus-pressed juice, carrot-pressed juice, citrus-pressed cake, and additives. The mixing ratios of the four CCJ were as follows (all ratios given in the order of citrus-pressed juice : carrot-pressed juice : citrus-pressed cake : additives; 70:30:0:0 for CCJ-1, 65:30:0:5 for CCJ-2, 65:30:5:0 for CCJ-3, and 60:30:10:0 for CCJ-4. Acidity was low in CCJ-3 and -4 at 0.82 and 0.80, respectively, compared with 0.95 in CCJ-1. The fructose, glucose, and sucrose content was 2.11~5.76 g/100 g, 1.20~2.75 g/100 g, and 3.00~4.21 g/100 g, respectively. Total phenolic content was 1.17 and 1.22 times high as 863 and 898 mg% in CCJ-3 and -4, respectively, compared with 735 mg% in CCJ-1. DPPH radical scavenging activities of methanol extracts of CCJ-3 and -4 were 3.05 and 3.29 times as high as 58.7% and 63.3%, respectively, compared with 19.2% in CCJ-1. Superoxide anion scavenging activities were also 1.67 and 1.80 times higher in CCJ-3 and -4 than that of CCJ-1. Inhibition of NO production in methanol extracts of CCJ-4 were 1.15 and 1.57 times as high as 20.9% and 28.5%, respectively, compared with 18.2% in CCJ-1. Based on the sensory evaluation, CCJ-3 was more preferable in terms of color, flavor, taste, and overall preference than CCJ-1, -2, and -4. It was concluded that CCJ-3 made with 65% citrus-pressed juice, 30% carrot-pressed juice, and 5% citrus-pressed cake were high in antioxidative activity and the inhibition of NO production, and more preferable in terms of sensory attributes.

Properties of Semen and Sperm Motility in Black Seabream, Acanthopagrus schlegeli (감성돔, Acanthopagrus schlegeli 정액의 특성과 정자의 운동성)

  • Chang Young Jin;Lim Han Kyu;Kho Kang Hee
    • Journal of Aquaculture
    • /
    • v.8 no.3
    • /
    • pp.149-157
    • /
    • 1995
  • In order to obtain the basic knowledges concerned to the semen preservation of aquacultural fishes, studies on the physical and chemical properties of semen, and sperm motility with the different osmotic pressures making by adding $Na^+,\;K^+,\; Mg^{++},\;and\;Ca^{++}$ to artificial seawater (ASW) were conducted in black seabream, Acanthopagrus schlegeli. Average semen volume per fish in one strip was 1.97ml and sperm concentration was $2.33\pm1.30\times10^{10}$ sperm/ml. Spermatocrit and pH of semen were $90.6\pm5.0\;and\;8.3\pm0.1$, respectively, Osmotic pressures of rearing seawater, seminal fluid and plasma were $939\pm24,382\pm70\;and\;342\pm77$ mOsm/l, and $Na^+,\;K^+$ and $Cl^-$ concentrations of seminal fluid were $169.5\pm4.5,\;4.9\pm2.2,\;156.0\pm2.0\;mM/l$, respectively. When semen were diluted by using $Na^+,\;K^+,\;Mg^{++}\;and\;Ca^{++}$ free ASW, only $Na^+$ free ASW had no sperm motility. As raising osmotic pressure graduary by addition of 1M NaCl to the $Na^+$ free ASW, spermatozoa showed the high motilities in 457-1128 mOsm/l, but the low motilities in 1398-1736 mOsm/l. In the case of same treatments with 1M of KCl, $MgC1_2\;and\;CaC1_2$ to the $K^+,\;Mg^{++}\;and\;Ca^{++}$ free ASW, spermatozoa revealed the high motilities in $904\~1434,\;818\~1175\;and\;956\~1343$ mOsm/l, respectively.

  • PDF

Development of Practical Advanced Oxidation Treatment System for Decontamination of Soil and Groundwater Contaminated with Chlorinated Solvent (TCE, PCE) : Phase I (염소계 화합물(TCE, PCE)로 오염된 토양 및 지하수 처리를 위한 실용적 고도산화처리시스템 개발 (I))

  • Sohn, Seok-Gyu;Lee, Jong-Yeol;Jung, Jae-Sung;Lee, Hong-Kyun;Kong, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.5
    • /
    • pp.105-114
    • /
    • 2007
  • The most advanced oxidation processes (AOPs) are based on reactivity of strong and non-selective oxidants such as hydroxyl radical (${\cdot}OH$). Decomposition of typical DNAPL chlorinated compounds (TCE, PCE) using various advanced oxidation processes ($UV/Fe^{3+}$-chelating agent/$H_2O_2$ process, $UV/H_2O_2$ process) was approached to develop appropriate methods treating chlorinated compound (TCE, PCE) for further field application. $UV/H_2O_2$ oxidation system was most efficient for degrading TCE and PCE at neutral pH and the system could remove 99.92% of TCE after 150 min reaction time at pH 6($[H_2O_2]$ = 147 mM, UVdose = 17.4 kwh/L) and degrade 99.99% of PCE within 120 min ($[H_2O_2]$ = 29.4 mM, UVdose = 52.2 kwh/L). Whereas, $UV/Fe^{3+}$-chelating agent/$H_2O_2$ system removed TCE and PCE ca. > 90% (UVdose = 34.8 kwh/L, $[Fe^{3+}]$ = 0.1 mM, [Oxalate] = 0.6 mM, $[H_2O_2]$ = 147 mM) and 98% after 6hrs (UVdose = 17.4 kwh/L, $[Fe^{3+}]$ = 0.1 mM, [Oxalate] = 0.6 mM, $[H_2O_2]$ = 29.4 mM), respectively. We improved the reproduction system with addition of UV light to modified Fenton reaction by increasing reduction rate of $Fe^{3+}$ to $Fe^{2+}$. We expect that the system save the treatment time and improve the removal efficiencies. Moreover, we expect the activity of low molecular organic compounds such as acetate or oxalate be effective for maintaining pH condition as neutral. This oxidation system could be an economical, environmental friendly, and practical treatment process since the organic compounds and iron minerals exist in nature soil conditions.

INFLUENCE OF LIGHT IRRADIATION OVER SELF-PRIMING ADHESIVE ON DENTIN BONDING (상아질접착제에 대한 광조사가 접착에 미치는 영향)

  • 류현욱;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.409-417
    • /
    • 2001
  • The purpose of this study was to investigate the influence of light irradiation over self-priming adhesive on dentin bonding. After acid etching the exposed dentin, a self-priming adhesive (Prime&Bond$^{\circledR}$NT dental adhesive system Dentsply DeTrey, GmbH, Konstanz, Germany) was applied and light irradiation was done for 20 sec with regular intensity (600 mW/$\textrm{cm}^2$) in group I and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in group III. No light irradiation was done over self-priming adhesive in groups II and IV. Composite resin was added on the self-priming adhesive and irradiated for 40 sec with regular intensity (600 mW/$\textrm{cm}^2$) in groups I and II and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in groups III and IV. To see the effect of light curing time on dentin bonding, another 3 group specimens were prepared. Without light-irradiation over self-priming adhesive, added composite resin was irradiated for 3, 6, or 12 sec with ultra-high intensity light. After bonded specimens were stored in 37$^{\circ}C$ distilled water for 24 hours, shear bond strength were measured using a universal testing machine (4202, Instron, Instron Co., U.S.A.) and fractured surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan). Statistical analysis were done with one-way, two-way ANOVA and chi-square test. The results were as follows : 1. The shear bond strengths from the groups irradiated over self-priming adhesive were significantly higher than those from the groups without irradiation (p<0.05). 2. There was no significant shear bond strength difference between regular intensity light irradiation groups and ultra-high intensity ones (p>0.05). 3. There was no significant shear bond strength difference among various irradiation time groups with ultra-high intensity ones (p>0.05). 4. In stereomicroscopic examination of fractured surfaces, adhesive-cohesive mixed failure mode was mostly seen in all groups, and there was no significant difference in failure mode among groups (p>0.05).

  • PDF

EFFECT OF APF GEL ON THE SURFACE OF COMPOSITE RESIN (복합레진 표면에 대한 APF gel의 영향)

  • Yuk, Gun-Yeung;Yang, Kyu-Ho;Kim, Seon-Mi;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.43-52
    • /
    • 2006
  • Topical fluoride application for children is a widely peformed procedure in the field of pediatric dentistry to prevent dental caries. However, it is recently recognized as having some unwanted effects on several esthetic restorative materials as it roughens the surface of the restorative materials. The aim of this study was to evaluate the surface changes in composite resins to topical fluoride. Composite resins(Z $250^{(R)}$, Ultraseal $XT^{(R)}$ Filtek $flow^{(R)}$ $Revolution^{(R)}$, $Denfil^{(R)}$) in topical fluoride agents were immersed and their surface roughness, weight loss and SEM were evaluated. The results were as follows : 1. The 4 minutes-immersion groups showed more roughened surface than 1 minute-immersion groups and the control groups showed the smoothest surface among all the materials, and there was statistically significant difference except the revolution between the groups. 2. There was no significant difference between the 1 minute-immersion groups and 4 minutes-immersion groups in weight loss. 3. The experimental group treated with topical fluoride gel showed the generally mere roughened surface than control group in the SEM findings.

  • PDF

3-D Finite element stress analysis in screw-type, cement-type, and combined-type implant fixed partial denture designs (임플란트 상부보철물의 유지형태에 따른 3차원 유한요소 응력분석)

  • Lee, Sung-Chun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.365-375
    • /
    • 2009
  • Statement of problems: Stress analysis on implant components of the combined screw- and cement-retained implant prosthesis has not investigated yet. Purpose: The purpose of this study was to assess the load distribution characteristics of implant prostheses with the different prosthodontic retention types, such as cement-type, screw-type and combined type by using 3-dimensional finite element analysis. Material and methods: A 3-dimensional finite element model was created in which two SS II implants (Osstem Co. Ltd.) were placed in the areas of the first premolar and the first molar in the mandible, and three-unit fixed partial dentures with four different retention types were fabricated on the two SS II implants. Model 1 was a cement-retained implant restoration made on two cement-retained type abutments (Comocta abutment; Osstem Co. Ltd.), and Model 2 was a screw-retained implant restoration made on the screw-retained type abutments (Octa abutment; Osstem Co. Ltd.). Model 3 was a combined type implant restoration made on the cement-retained type abutment (Comocta abutment) for the first molar and the screw-retained type abutment (Octa abutment) for the first premolar. Lastly, Model 4 was a combined type implant restoration made on the screw-retained type abutment (Octa abutment) for the first molar and the cement-retained type abutment (Comocta abutment) for the first premolar. Average masticatory force was applied on the central fossa in a vertical direction, and on the buccal cusp in a vertical and oblique direction for each model. Von-Mises stress patterns on alveolar bone, implant body, abutment, abutment screw, and prosthetic screw around implant prostheses were evaluated through 3-dimensional finite element analysis. Results: Model 2 showed the lowest von Mises stress. In all models, the von Mises stress distribution of cortical bone, cancellous bone and implant body showed the similar pattern. Regardless of loading conditions and type of abutment system, the stress of bone was concentrated on the cortical bone. The von-Mises stress on abutment, abutment screw, and prosthetic screw showed the lower values for the screw-retained type abutment than for the cement-retained type abutment regardless of the model type. There was little reciprocal effect of the abutment system between the molar and the premolar position. For all models, buccal cusp oblique loading caused the largest stress, followed by buccal cusp vertical loading and center vertical loading. Conclusion: Within the limitation of the FEA study, the combined type implant prosthesis did not demonstrate more stress around implant components than the cement type implant prosthesis. Under the assumption of ideal passive fit, the screw-type implant prosthesis showed the east stress around implant components.