• Title/Summary/Keyword: 착의 실험

Search Result 175, Processing Time 0.031 seconds

A Study on Evaluation of LED Lighting Environments for Energy Saving and Work Effectiveness (에너지 저감과 업무 효율성을 위한 LED 조명환경 평가에 대한 연구)

  • Kim, Hyung-Sun;Lim, Jae-Hyun;Lee, Kee-Sun;Kim, Kil-Hee;Jung, Hee-Chang;Kim, Jin Ho
    • Science of Emotion and Sensibility
    • /
    • v.18 no.2
    • /
    • pp.45-54
    • /
    • 2015
  • This study carried out an experiment to identify subject's work effectiveness and energy saving effect using LED light. Towards this end, this study configured nine various lighting environments in order to control PWM (Pulse Width Modulation) and illuminance (lux), which are the characteristics of LED light. The PWM ratio of LED light was set as R:G:B=1:1:1, R:G:B=4:1:5, and R:G:B=8:7:7, respectively, and illuminance (lux) was set as 400 lx, 700 lx, and 1000 lx, respectively. In addition, the indoor environment was set temperature $20-24^{\circ}C$, humidity 50%-60%, and the amount of clothing 1. This study analyzed work effectiveness and energy consumption in nine lighting environments, each. Error correction was performed for work effectiveness analysis, and cumulative power consumption was measured in each lighting environment for energy consumption analysis. According to experiment results through the lighting environments suggested in this study, accuracy and spent time effectiveness were good in 700lux and higher than 400lux. For spent time, the best effectiveness was revealed in the suggested PWM ratio, R:G:B=8:7:7. The lowest power consumption on each illuminance (lux) was revealed in the order of R:G:B=8:7:7, RGB=1:1:1, and R:G:B=4:1:5. Therefore, pulse-width modulation effect is proposed in this paper was found to affect the efficiency and energy saving.

Removal of As(III) and Phenol by Multi-functional Property of Activated Carbon Impregnated With Manganese (망간첨착 활성탄의 다기능성을 이용한 3가 비소 및 페놀 제거)

  • Yu, Mok-Ryun;Hong, Soon-Chul;Yang, Jae-Kyu;Chang, Yoon-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.3
    • /
    • pp.52-58
    • /
    • 2008
  • Mn-impregnated activated carbon (Mn-AC) prepared at different conditions was applied in the treatment of synthetic wastewater containing both organic and inorganic contaminants. Phenol and As(III) was used as the representative organic and inorganic contaminants, respectively. After evaluation of the physicochemical characteristic and stability of Mn-AC, oxidation of As(III) as well as adsorption of phenol by activated carbon(AC) and Mn-AC were investigated in a batch reactor. To investigate the stability of Mn-AC, dissolution of Mn from each Mn-AC was measured pH ranging from 2 to 4. Although Mn-AC was unstable at a strong acidic condition, the dissoluted Mn was below 3 ppm at pH 4. XRD analysis of Mn-AC indicated that the mineral type of the impregnated manganese was $Mn_2O_3$. From the simultaneous treatment of As(III) and phenol by AC and Mn-AC, As(III) oxidation by Mn-AC was greater than that by AC at lower pH, while the reverse order was observed at higher pH. After impregnation of Mn onto AC, 13% decrease of the surface area was observed, causing 8% reduction of phenol removal. Considering removal properties of As(III) and phenol, Mn-AC could be applied in the simultaneous treatment of wastewater contaminated with multi-contaminants.

Development of New Hanbok Cheollik One Piece Prototype

  • Cha, Su-Joung;An, Myung-Sook;Heo, Seung-Yeun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.10
    • /
    • pp.125-137
    • /
    • 2021
  • This study was intended to develop a prototype of new Hanbok Cheollik one-piece based on design extracted through a preference survey on new Hanbok Cheollik one-piece. Through this, it was intended to provide information on patterns that are fundamental to the production of new Hanbok Cheollik one piece. The pattern of the experiment was produced by modifying D pattern, which was selected as excellent in the comparison of commercial Cheollik one-piece patterns. The SPSS 26.0 program was used to analyze the appearance evaluation of patterns. As a result of the 1st evaluation of appearance and garment pressure, the shoulder, sleeve length, skirt length and sleeve width required modification, reducing the sleeve length by 8.0cm and the sleeve width by 1.0cm in total. The length of the skirt was reduced by 5.0cm and the shoulder end point was reduced by 0.5cm on both sides to modify the shoulder width. As a result of the 2nd evaluation, the waist area, sleeve width, and skirt wrinkles were required to be corrected, reducing 2.0 cm waist width and 1.0 cm sleeve width and removing wrinkles on the front center and side area. The final pattern was highly appreciated. In future studies, it is thought that research should be conducted through study of Cheollik one-piece pattern according to material and age and the actual wearing experiment according to fabric and age.

The Treatment of Heavy Metal-cyanide Complexes Wastewater by Zn$^{+2}$/Fe$^{+2}$ Ion and Coprecipitation in Practical Plant (II) (아연백법 및 공침공정을 이용한 복합 중금속-시안착염 폐수의 현장처리(II))

  • Lee, Jong-Cheul;Lee, Young-Man;Kang, Ik-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.5
    • /
    • pp.524-533
    • /
    • 2008
  • Industrial wastewater generated in the electroplating and metal finishing industries typically contain toxic free and complex metal cyanide with various heavy metals. Alkaline chlorination, the normal treatment method destroys only free cyanide, not complex metal cyanide. A novel treatment method has been developed which destroys both free and complex metal cyanide as compared with Practical Plant(I). Prior to the removal of complex metal cyanide by Fe/Zn coprecipitation and removal of others(Cu, Ni), Chromium is reduced from the hexavalent to the trivalent form by Sodium bisulfite(NaHSO$_3$), followed by alkaline-chlorination for the cyanide destruction. The maximum removal efficiency of chromium by reduction was found to be 99.92% under pH 2.0, ORP 250 mV for 0.5 hours. The removal efficiency of complex metal cyanide was max. 98.24%(residual CN: 4.50 mg/L) in pH 9.5, 240 rpm with 3.0 $\times$ 10$^{-4}$ mol of FeSO$_4$/ZnCl$_2$ for 0.5 hours. The removal efficiency of Cu, Ni using both hydroxide and sulfide precipitation was found to be max. 99.9% as Cu in 3.0 mol of Na$_2$S and 93.86% as Ni in 4.0 mol of Na$_2$S under pH 9.0$\sim$10.0, 240 rpm for 0.5 hours. The concentration of residual CN by alkaline-chlorination was 0.21 mg/L(removal efficiencies: 95.33%) under the following conditions; 1st Oxidation : pH 10.0, ORP 350 mV, reaction time 0.5 hours, 2nd Oxidation : pH 8.0, ORP 650 mV, reaction time 0.5 hours. It is important to note that the removal of free and complex metal cyanide from the electroplating wastewater should be employed by chromium reduction, Fe/Zn coprecipitation and, sulfide precipitation, followed by alkaline-chlorination for the Korean permissible limit of wastewater discharge, where the better results could be found as compared to the preceding paper as indicated in practical treatment(I).

Fabrication of Strain Sensor Based on Graphene/Polyurethane Nanoweb and Respiration Measurement (그래핀/폴리우레탄 나노웹 기반의 스트레인센서 제작 및 호흡측정)

  • Lee, Hyocheol;Cho, Hyeon-seon;Lee, Eugene;Jang, Eunji;Cho, Gilsoo
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2019
  • The purpose of this study is to develop a strain sensor based on a nanoweb by applying electrical conductivity to a polyurethane nanoweb through the use of Graphene. For this purpose, 1% Graphene ink was pour-coated on a polyurethane nanoweb and post-treated with PDMS (Polydimethylsiloxane) to complete a wearable strain sensor. The surface characteristics of the specimens were evaluated using a field emission scanning electron microscope (FE-SEM) to check whether the conductive material was well coated on the surface of the specimen. Electrical properties of the specimens were measured by using a multimeter to measure the linear resistance of the specimen and comparing how the line resistance changes when 5% and 10% of the specimens are tensioned, respectively. In order to evaluate the performance of the specimen, the gauge factor was obtained. The evaluation of the clothing was performed by attaching the completed strain sensor to the dummy and measuring the respiration signal according to the tension using MP150 (Biopac system Inc., USA) and Acqknowledge (ver. 4.2, Biopac system Inc., U.S.A.). As a result of the evaluation of the surface characteristics, it was confirmed that all the conductive nanoweb specimen were uniformly coated with the Graphen ink. As a result of measuring the resistance value according to the tensile strength, the specimen G, which was treated with just graphene had the lowest resistance value, the specimen G-H had the highest resistance value, and the change of the line resistance value of the specimen G and the specimen G-H is increased to 5% It is found that it increases steadily. Unlike the resistance value results, specimen G showed a higher gauge rate than specimen G-H. As a result of evaluation of the actual clothes, the strain sensor made using the specimen G-H measured the stable peak value and obtained a signal of good quality. Therefore, we confirmed that the polyurethane nanoweb treated with Graphene ink plays a role as a breathing sensor.

Factors to Affect the Growth of Filamentous Periphytic Algae in the Artificial Channels using Treated Wastewater (하수처리수를 이용한 인공수로에서 사상성 부착조류의 성장에 영향을 미치는 요인들)

  • Park, Ku-Sung;Kim, Ho-Sub;Kong, Dong-Soo;Shin, Jae-Ki;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.1 s.115
    • /
    • pp.100-109
    • /
    • 2006
  • This study evaluated the effects of water velocity, substrates, and phosphorus concentrations on the growth of filamentous periphytic algae (FPA) in the two types of artificial channel systems using treated wastewater. Controlled parameters included 5 ${\sim}$ 15 cm $s^{-1}$ for the water velocity; 10 and 20 mm wire meshes, natural fiber net, gravel and tile for the substrates: and 0.05 ${\sim}$ 1.0 mgP $L^{-1}$ for the P concentration. Algal growth rate of FPA was compared using both chi. a and dry weight change with time. Under the controlled water velocity range, the growth of FPA increased with the velocity, but the maximum growth rate was shown in the velocity of 10 cm $s^{-1}$. The substrate that showed the maximum growth of FPA differed between the artificial channel and indoor channel, due to the influence of suspended matters which caused the clogging of the meshed substrates. Under the controled range of P concentration, the growth rates of all three FPA species (Spirogyra turfosa, Oedogonium fovelatum, Rhizoclonium riparium) increased with the P increase, but they showed the differential growth rates among different P concentrations. The results of this study suggest that under the circumstance having an large amount of nutrients FPA develop the biomass rapidly and that even a little increase over the threshold velocity causes the detachment of filamentous periphytic algae. Thus, FPA dynamics in eutrophic streams, such as those receiving treated wastewater, seem to be sensitive to the water velocity. On the other hand, detached algal filaments could deteriorate water quality and ecosystem function in receiving streams or down-stream, and thus they need to be recognized as an important factor in water quality management in eutrophic streams.

Physiological responses and subjective sensation of human body wearing Cool Mapsi in air-conditioning environment (냉방환경에서 쿨맵시 착용에 따른 생리적 반응과 주관적 감각)

  • Kang, Noo-Ri;Na, Young-Joo
    • Science of Emotion and Sensibility
    • /
    • v.13 no.2
    • /
    • pp.359-370
    • /
    • 2010
  • The purpose of this study is to test the performance of the recommended summer dressing for office man through the analysis of skin temperature changes by air-conditioning temperature. We tested two clothing combinations; formal wear with necktie and casual shirts without necktie as for Cool mapsi. 4 male subjects sat to stabilize for thirty minutes after entering artificial-climate chamber with both temperature of $25^{\circ}C$, $27^{\circ}C$ and $50{\pm}10%$ R.H. And during 60 minute experiments of simulating office work, the subjective feelings including thermal, humidity and comfort sensation, skin temperature, clothing humidity and sweat amount were measured at the equal intervals. The result is that formal wear of $25^{\circ}C$ and Cool mapsi of $27^{\circ}C$ show good values such as low skin temperature, low clothing humidity and neutral thermal sensation. And Cool mapsi of $25^{\circ}C$ shows the risk of low rectal temperature for long and static energy level of office work. Formal wear of $27^{\circ}C$ shows high values of mean skin temperature, clothing humidity and thermal sensation. Second experiment was to find the ambient temperature when the subject wearing formal wear shows the skin temperature corresponding to which he shows on Cool mapsi of $27^{\circ}C$. The air-conditioning temperature on wearing formal wear has to be $2^{\circ}C$ lower to produce the corresponding skin temperature to which shows on wearing Cool mapsi of $27^{\circ}C$. Therefore it is possible to increase room temperature to $27^{\circ}C$, when wear Cool mapsi for summer office, for skin temperature and thermal sensation are produced the same.

  • PDF

EFFECT OF APF GEL ON THE SURFACE OF COMPOSITE RESIN (복합레진 표면에 대한 APF gel의 영향)

  • Yuk, Gun-Yeung;Yang, Kyu-Ho;Kim, Seon-Mi;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.43-52
    • /
    • 2006
  • Topical fluoride application for children is a widely peformed procedure in the field of pediatric dentistry to prevent dental caries. However, it is recently recognized as having some unwanted effects on several esthetic restorative materials as it roughens the surface of the restorative materials. The aim of this study was to evaluate the surface changes in composite resins to topical fluoride. Composite resins(Z $250^{(R)}$, Ultraseal $XT^{(R)}$ Filtek $flow^{(R)}$ $Revolution^{(R)}$, $Denfil^{(R)}$) in topical fluoride agents were immersed and their surface roughness, weight loss and SEM were evaluated. The results were as follows : 1. The 4 minutes-immersion groups showed more roughened surface than 1 minute-immersion groups and the control groups showed the smoothest surface among all the materials, and there was statistically significant difference except the revolution between the groups. 2. There was no significant difference between the 1 minute-immersion groups and 4 minutes-immersion groups in weight loss. 3. The experimental group treated with topical fluoride gel showed the generally mere roughened surface than control group in the SEM findings.

  • PDF

A Study on a Quantified Structure Simulation Technique for Product Design Based on Augmented Reality (제품 디자인을 위한 증강현실 기반 정량구조 시뮬레이션 기법에 대한 연구)

  • Lee, Woo-Hun
    • Archives of design research
    • /
    • v.18 no.3 s.61
    • /
    • pp.85-94
    • /
    • 2005
  • Most of product designers use 3D CAD system as a inevitable design tool nowadays and many new products are developed through a concurrent engineering process. However, it is very difficult for novice designers to get the sense of reality from modeling objects shown in the computer screens. Such a intangibility problem comes from the lack of haptic interactions and contextual information about the real space because designers tend to do 3D modeling works only in a virtual space of 3D CAD system. To address this problem, this research investigate the possibility of a interactive quantified structure simulation for product design using AR(augmented reality) which can register a 3D CAD modeling object on the real space. We built a quantified structure simulation system based on AR and conducted a series of experiments to measure how accurately human perceive and adjust the size of virtual objects under varied experimental conditions in the AR environment. The experiment participants adjusted a virtual cube to a reference real cube within 1.3% relative error(5.3% relative StDev). The results gave the strong evidence that the participants can perceive the size of a virtual object very accurately. Furthermore, we found that it is easier to perceive the size of a virtual object in the condition of presenting plenty of real reference objects than few reference objects, and using LCD panel than HMD. We tried to apply the simulation system to identify preference characteristics for the appearance design of a home-service robot as a case study which explores the potential application of the system. There were significant variances in participants' preferred characteristics about robot appearance and that was supposed to come from the lack of typicality of robot image. Then, several characteristic groups were segmented by duster analysis. On the other hand, it was interesting finding that participants have significantly different preference characteristics between robot with arm and armless robot and there was a very strong correlation between the height of robot and arm length as a human body.

  • PDF

Development of u-Health Care System for Dementia Patients (치매환자를 위한 u-Health Care 시스템 개발)

  • Shin, Dong-Min;Shin, Dong-Il;Shin, Dong-Kyoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.12
    • /
    • pp.1106-1113
    • /
    • 2013
  • For patients who have senile mental disorder such as dementia, quantity of excercise and amount of sunlight are important clue for dose and the treatment. Therefore, monitoring health information of daily life is necessary for patients' safety and healthy life. Portable & wearable sensor device and server configuration monitoring data are needed to provide these services for patients. Watch-type device(smart watch) which patients wear and server system are developed in this paper. Smart watch developed includes GPS, accelerometer and illumination sensor, and can obtain real time health information by measuring the position of patients, quantity of exercise and amount of sunlight. Server system includes the sensor data analysis algorithm and web server that doctor and protector can monitor through sensor data acquired from smart watch. The proposed data analysis algorithm acquires quantity of exercise information and detects step count in patients' motion acquired from acceleration sensor and to verify this, the three cases with fast pace, slow pace, and walking pace show 96% of the experimental result. If developed u-Healthcare System for dementia patients is applied, more high-quality medical service can be provided to patients.