• Title/Summary/Keyword: 착용시간

Search Result 298, Processing Time 0.026 seconds

The Effects of Visual acuity increase in mono vision by the P-VEP study using Netspeg lens (Netspag Lens를 이용한 Mono vision에서 시력개선 효과에 대한 P-VEP 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.241-246
    • /
    • 2005
  • The aim of the study was performed the wave analysis of P-VEP on the development of visual function using Netspeg lens in monocular of refraction error subjects. The P-VEP of three channels were recorded by the Bausch Lomb system. Ten adults (five males, five females, mean=22 years, range=19 to 23) subjects were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, ocular disease, and so on. Visual acuity and refraction test were performed for each subject with mono vision by using the Netspeg lens. Also subjects viewed the P-VEP stimulus with mono vision through the corrected visual acuity with Netspeg lens during VEP test. The results of study suggest that the mono vision using Netspeg lens is better than with non-Netspeg lens on the visual acuity and image symptom. On the other hand, the analysis of P-VEP suggest that the amplitude of wave is larger when the eye using Netspeg lens receives the P-VEP stimulus compared with the non Netspeg lens. Also, on the wave style of P-VEP, the eye of Netspeg lens was more stable compared with the naked eye. However, on latency period of P-VEP, the eye of non Netspeg lens was more longer than the eye of Netspeg lens. But, on the other hand, the right and left eye have similar results. In conclusion, this study indicated that the visual acuity and visual function of eye of Netspeg lens used have a better than the eye of non-Netspeg lens in Mono Vision.

  • PDF

A study on the sleeve-shaped platform of POF-based joint angle sensor for arm movement-monitoring clothing (인체동작 모니터링 위한 광섬유 기반 의류 소매형 동작센서 연구)

  • Kang, Da-Hye;Lee, Young-Jae;Lee, Jeong-Whan;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.14 no.2
    • /
    • pp.221-226
    • /
    • 2011
  • Although diverse researches on sensing method of human movement have been performed, there are still many limitations to the existing methods. As a part of supplementing the limitations to the existing motion sensing methods, this study aimed to execute an exploratory examination on a POF-based sleeve-shaped motion sensor for less restrictive sensing of human movement. In this study, a set of POF-based motion sensor, which was embedded in a sleeve-shaped platform was devised, and a set of exploratory experiments was performed on the possibility of sensing of human movement as diverse as in daily life, through this device. The scope of this research was limited to an exploration on the possibility and basic elements of POF-based sleeve-shaped motion sensor, while the influence of sleeve patterns, those of wearer's somatotype, those of sewing method were not studied in this study. When compared to the pre-existing methods, the POF-based motion sensor platformed on sleeve in this study, which was purposively devised to be applied to the motion sensing clothing shows some beneficial characteristics : more sensitive measurement on human motion, low cost, no timely restriction in sensing, no request for gigantic apparatus and space for sensing.

  • PDF

A Study on 2D Pattern Design Module and 3D Cloth Simulation System based on Octree Space Subdivision Method (2차원 패턴 디자인 모듈과 Octree 공간 분할 방법을 이용한 3차원 의복 시뮬레이션 시스템에 관한 연구)

  • Kim, Ju-Ri;Joung, Suck-Tae;Jung, Sung-Tae
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.4
    • /
    • pp.527-536
    • /
    • 2007
  • This paper proposes a 3D fashion design system that generates a 3D clothes model by using 2D patterns of clothes and drapes the 3D clothes model on a 3D human model. In the proposed system, 2D patterns of clothes are designed by selecting comer points of 2D mesh. After designing 2D patterns, a 3D clothes model is designed by describing the control points to be connected between 2D patterns. The proposed system reads a 3D human body model file and the designed 3D clothes model and creates a 3D human model putting on the clothes by using the mass-spring model based physical simulation. It calculates collision and reaction between the triangles of human body model and those of clothes for realistic simulation. Because the number of triangles is very large, the collision and reaction processing need a lot of time. To solve this problem, the proposed system decreases the number of collision and reaction processing by using the Octree space subdivision technique. It took a few seconds for generating a 3D human model putting on the designed 3D clothes.

  • PDF

Development of Tuberculosis Education Model for Junior Health Care Professionals (예비보건의료인을 위한 결핵 교육 모형 구축)

  • Baek, Seolhyang;Lee, Ji-Soo;Lee, Hyun-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.5
    • /
    • pp.432-445
    • /
    • 2018
  • For health care professionals(HCPs) who have relatively higher possibility of exposing tuberculosis(Tb), it is important for them to equip with proper levels of knowledge and prevention activities. In terms of establishment of Tb education model for junior HCPs, therefore, literature review was done alongside 129 junior HCPs and 14 HCPs were asked to answer questionnaires and telephone survey. The results are follows.; Firstly, six educational themes such as epidermiology of Tb, Tb transmission and patho-physiology, test and diagnosis, latent Tb, Tb treatment, and Tb prevention were identified, based on the literature review. Secondly, the junior HCPs showed lower levels of knowledge regarding epidermiology, transmission and patho-physiology and latent Tb, compared to the other themes. When education courses are planned, longer period of time should be given to the lower level of knowledge areas. Thirdly, the HCPs emphasized that definition and type of Tb should be well integrated into the education in particular epidermiology education. They also responded that hospital infection and infection cycle of Tb need to be addressed during educational session about transmission and patho-physiology. in addition, they said that specific and detailed contents about diagnosis and group examination should be carefully delivered during the education, along with diagnosis, test and application of personal protective devices during education of latent Tb. They also answered that patient education and adverse effect of Tb medication should be taught during Tb treatment session, as well as self activities of health promotion for junior HCPs and systematic TB education as key way of Tb prevention. As the findings were from limited numbers of respondents and contained the sampling bias, the result has to be carefully interpretated prior to generalization. Therefore, further survey with larger study population is required in terms of development of Tb education model.

A Study on Apparatus of Smart Wearable for Mine Detection (스마트 웨어러블 지뢰탐지 장치 연구)

  • Kim, Chi-Wook;Koo, Kyong-Wan;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.263-267
    • /
    • 2015
  • current mine detector can't division the section if it is conducted and it needs too much labor force and time. in addition to, if the user don't move the head of sensor in regular speed or move it too fast, it is hard to detect a mine exactly. according to this, to improve the problem using one direction ultrasonic wave sensing signal, that is made up of human body antenna part, main micro processor unit part, smart glasses part, body equipped LCD monitor part, wireless data transmit part, belt type power supply part, black box type camera, Security Communication headset. the user can equip this at head, body, arm, waist and leg in removable type. so it is able to detect the powder in a 360-degree on(under) the ground whether it is metal or nonmetal and it can express the 2D or 3D film about distance, form and material of the mine. so the battle combats can avoid the mine and move fast. also, through the portable battery and twin self power supply system of the power supply part, combat troops can fight without extra recharge and we can monitoring the battle situation of distant place at the command center server on real-time. and then, it makes able to sharing the information of battle among battle combats one on one. as a result, the purpose of this study is researching a smart wearable mine detector which can establish a smart battle system as if the commander is in the site of the battle.

Perfusion RRI of the Brain Using Oxygen Inhalation (산소 호흡을 이용한 뇌의 관류 자기공명영상)

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Purpose : To know the possibility of clinical application of MRI using oxygen inhalation as a perfusion MRI Materials and methods : Two healthy volunteers and three patients of one moyamoya disease, one acute infarction and one meningioma were studied using a 1.5 Tesla MRI unit. Oxygen (15 liters/min) mixed with room air was given using face mask from 8 second to 35 second during the study. Images were acquired 25 times (scan time per study were 1.6 seconds) using susceptibility contrast EPI (echo planar image) sequence. Difference maps were acquired by early (study 12-18), and late (study 19-25) O2 inhalation image groups minus pre-O2 inhalation image group (study 3-9) with a Z-score of 0.7-1.0 using VB31C program of Magneton Vision. The resulting perfusion images were created by superimposition of difference maps on corresponding T1 weighted anatomic images. On moyamoya patient, similar perfusion images were acquired after Gd-DTPA injection, and compared with O2 inhalation perfusion images. Results ; The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers, and the patient of moyomoya disease, acute infarction and meningioma. On moyamoya patient, perfusion images with O2 inhalation are similar with perfusion images by Gd-DTPA injection. Conclusion 1 This study has demonstrated that the susceptibility contrast EPI by oxygen inhalation can be used as the clinically useful perfusion MRI technique

  • PDF

The Study of Scattering Dust and Radiation Dose in Pedestrian Tunnels in Metropolitan Area (수도권 보행터널 내부에 존재하는 비산 먼지와 방사선량의 연구)

  • Jung, Hongmoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.385-390
    • /
    • 2020
  • In the present, external environmental factors affect human health. In particular, the most important issue is fine dust in these days. Because fine dust is inhaled through the human respiratory system is known to be harmful to health. Tunnels for cars and people can also be easily seen around us. This study, the amount of scattering radiation was measured for walkable tunnels about dust. For the measurement method, dust and radiation dose in the tunnel were measured on good weather (fine dust level: 0 ~ 30 ㎍/㎥) and normal day (fine dust level: 0 ~ 80 ㎍/㎥). The measurement resulted in an increase of 10~20 % of dust in the center of the tunnel on a good weather day and an increase of 20~30 % of dust in the center of the tunnel on normal weather. On the other hand, the results of tunnel measurement of radiation dose increased by 10~20 % at the center of the tunnel non-depending on the weather. As a result, pedestrians should pay attention to scattering dust and scattered radiation while moving through the tunnel. Therefore, it is recommended to wear a filter mask of PM2.5 or less during frequent tunnel walking.

Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography (혈관조영 및 중재적 시술 분야 내 종사자의 눈에 대한 선량평가)

  • Kim, Jung-hoon;Cho, Yong-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2018
  • In the field of angiography and interventional radiology, it is said that the risk of radiation exposure to the eyes is high due to the characteristics of work, but currently divided dose assessment and management are not carried out in reality. Therefore, in this study, in order to evaluate the dose of the operator in the surgical environment and to analyze the shields, firstly, we selected the point where the operator is mainly located, evaluated the exposure dose of the eye after attaching the pocket dosimeter to the lateral angle point of the head and neck phantom, and evaluate shielding effect when wearing lead glasses that is currently commercialized. Secondly, we evaluated the tendency of the exposure dose of the eye and the shielding effect through simulation in the same geometric structure as the actual measurement. As a result, in the case of measurement using a dosimeter, the cumulative dose increased with the increase of the fluoroscopic time, and the tendency was different according to the position of the operator. Simulation results show that the dose distribution of the eye lens in the mathematical phantom is about 1.1 ~ 1.3 times higher than that of the cornea. Also, The protective effect of the lead glasses showed a shielding effect of at least 3.7 ~ 21.4% in each eye.

Three-Dimensional Image Display System using Stereogram and Holographic Optical Memory Techniques (스테레오그램과 홀로그래픽 광 메모리 기술을 이용한 3차원 영상 표현 시스템)

  • 김철수;김수중
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.6B
    • /
    • pp.638-644
    • /
    • 2002
  • In this paper, we implemented a three dimensional image display system using stereogram and holographic optical memory techniques which can store many images and reconstruct them automatically. In this system, to store and reconstruct stereo images, incident angle of reference beam must be controlled in real time, so we used BPH(binary phase hologram) and LCD(liquid crystal display) for controlling reference beam. The reference beams are acquired by Fourier transform of BPHs which designed with SA(simulated annealing)algorithm, and the BPHs are represented on the LCD with the 0.05 seconds time interval using application software for reconstructing the stereo images. And input images are represented on the LCD without polarizer/analyzer for maintaining uniform beam intensities regardless of the brightness of input images. The input images and BPHs are edited using application software(Photoshop) with having the same recording scheduled time interval in storing. The reconstructed stereo images are acquired by capturing the output images with CCD camera at the behind of the analyzer which transforms phase information into brightness information of images. In output plane, we used a LCD shutter that is synchronized to a monitor that display alternate left and right eye images for depth perception. We demonstrated optical experiment which store and reconstruct four stereo images in BaTiO$_3$ repeatedly using the proposed holographic optical memory techniques.

The Usefulness of a Wearable Smart Insole for Gait and Balance Analyses After Surgery for Adult Degenerative Scoliosis: Immediate and Delayed Effects (척추측만증 환자의 수술 효과 평가 수단으로서 웨어러블 스마트 깔창을 이용한 보행분석의 유용성)

  • Seo, Min Seok;Shin, Myung Jun;Kwon, Ae Ran;Park, Tae Sung;Nam, Kyoung Hyup
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.2
    • /
    • pp.184-192
    • /
    • 2020
  • This study presents a gait analysis method (including time series analysis) using a smart insole as an objective and quantitative evaluating method after lumbar scoliosis surgery. The participant is a degenerative lumbar scoliosis patient. She took 3-min-gait-test four times(before and 8, 16, and 204-days after surgery) and 6-min-gait-test once(204-days after surgery) with smart-insoles in her shoes. Each insole has 8-pressure sensors, an accelerometer, and a gyroscope. The measured values were used to compare the characteristics of gait before and after surgery. The analysis showed that all of the patient's gait parameters improved after surgery. And after 6 months, the gait was more stable. However, after long walk, the swing duration of one leg was slightly shorter than that of the other again. It was a preclinical problem that could not be found in the visual examination by the practitioner. With this analysis method we could evaluate the improvement of patient quantitatively and objectively. And we could find a preclinical problem. This analysis method will lead to the studies that define and distinguish gait patterns of certain diseases, helping to determine appropriate treatments.