• Title/Summary/Keyword: 착용시간

Search Result 298, Processing Time 0.024 seconds

The Current State of Lens Care in Contact Lens Wearer (콘택트렌즈 착용에 따른 사용자 실태조사)

  • Ryu, Geun Chang;Kim, In Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.15-20
    • /
    • 2002
  • The Hydroxyethyl methacrylate(HEMA) was developped in 1960's and later the use of contact lenses increased. At present more and more people use RGP contact lenses. Due to the wide range of optical corrections available and due to their high oxygen transmission Japanese and Korean people like them. Nevertheless one of nine CL users(beginners) stopped wearing the CL within the first year. We conducted a survey to evaluate the level of patient compliance in lens care and maintenance and to assess practitioner knowledge of contact lens information. Generally 6% of contact lens wearers drop out per year. The aim of this research was to find out what opticians can do to reduce the drop-out rate by getting information on handling, on general data of the patient and on optical prescription. Lens wearer were asked to complete a 10 question survey that focused on lens care-wear modality, lens replacement, storage, symptoms and case disinfection. There were total 180 participants in the study. Most of contact lens wearers have an inadequate understanding of contact lens care system. Therefore, it is important that contact lens specialists place more emphasis on practitioner education about general contact lens fields and reinforce patient education during the dispensing visit.

  • PDF

Effect of Wearing a Compression Stocking on Electromyogram of the Legs (동일인에서 한쪽 다리에만 압박스타킹을 착용했을 때 유발되는 다리 근육의 근전도 변화에 대한 정량적 분석)

  • Lee, Ji-Youn;Yuk, So-Hee;Yoo, Hyo-Gyung;Hong, Nam-Ju;Jeon, In-Cheol;Jung, Dongju
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.185-190
    • /
    • 2019
  • Compression stockings are widely used for prevention of varicose vein. Depending on manufacture, there are diverse types of compression stockings available. Most common type of compression stocking might be the one cover calf of a lower leg which has 20~30 mmHg pressure. Despite being widely used, possible side effects that may occur by wearing compression stockings have not been studied much. We analyzed for a long wearing effect of compression stocking. Participants wore the compression stocking over one leg for 7 days. During the period, all the participants did their ordinary works wearing the compression stocking. Electrocardiogram (ECG), ankle-brachial index (ABI), blood pressure (BP), and electromyogram (EMG) were measured at 0 day, 3rd day and 7th day. There was no effect of wearing compression stockings from ECG, ABI or BP. Only EMG that was measured on the covered muscle increased proportionally to the wearing time. Interestingly, EMG from the opposite leg that had never been covered by compression stocking decreased in proportion to the wearing date. These results suggest wearing a compression stocking for varicose vein may cause unintentional increase or decrease of EMG from the wearing or non-wearing legs, respectively.

Comparison of the Clinical Effect after Wearing Conventional and 2-Weeks Cosmetic Tinted Contact Lens (일반 미용 칼라 콘택트렌즈와 2주 교체용 미용 칼라 콘택트렌즈 착용에 따른 임상성능 비교)

  • Kim, Chang Jin;Kim, Jai-Min;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.15-26
    • /
    • 2009
  • Purpose: To compare and analyze the ocular changes after wearing conventional and 2-weeks cosmetic tinted contact lens, which were made of different material and fabrication method. Methods: Thirty five university students, age of twenties, participated in this study. With daily wearing schedule, they had worn temporary cosmetic tinted lens for 2 weeks and conventional tinted lens for two month in their right and left eye, respectively. Subjective symptoms and objective signs were graded by using CCLRU scales and corneal thickness were measured after 1 day and 2 months wearing, and under or over 5 hours wearing in a day, respectively. Results: Major subjective symptoms found in the student wearing cosmetic tinted contact lens for a 1 day and 2 months were dryness, redness, foreign body sensation and itchiness. It was also found that those symptoms were more severe in left eye (conventional cosmetic tinted contact lens) than right eye (2-weeks cosmetic tinted contact lens). However, symptoms of redness in both eyes showed statistically significant difference in the case of 1 day and 2 months wearing and under or over 5 hours wearing in a day (p=0.000). After 2 months wearing, left eye with conventional cosmetic tinted contact lens showed limbal redness (p=0.000) and bulbar conjunctival redness (p=0.012) with statistically significance, whereas there was no significant difference in both eyes before lens wear. Left eye showed statistically significant changes in all objective signs, but right eye showed palpebral conjunctival redness, corneal staining and conjunctival staining. Therefore, it was concluded that conventional cosmetic tinted contact lens may be more effective on ocular changes after wearing of lens. A statistically significant changes in both eyes after wearing lens were found that corneal thickness increased about $5{\mu}m$ (p=0.001) in right eye whereas $7{\mu}m$ (p=0.004) in left eye. Conclusions: A statistically significant number of participants in this study preferred to wearing of high Dk/t temporary cosmetic tinted contact lens made by sandwich method which resulted in less ocular changes and may give more healthy and safe ocular conditions.

  • PDF

Influence of Gaming Display and Wearing Glasses on Perceived Characteristics, Presence, and Fatigue (게임 디스플레이 종류와 안경착용 여부에 따른 영상의 인지된 특성, 프레즌스 그리고 피로도의 차이)

  • Lee, Hyun-Ji;Lee, Sang-Wook;Heo, Ok;Chung, Donghun
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2012.07a
    • /
    • pp.439-442
    • /
    • 2012
  • 3D 영상 산업과 더불어 3D가 적용됨으로써 유망한 산업 분야 중 하나가 바로 게임이다. 2D에서 3D 그래픽으로 그리고 현재는 3D 입체영상으로 진화하면서 이용자로 하여금 깊이감을 제공함으로써 더 큰 즐거움을 주고 있다. 본 연구에서는 게임에서의 입체영상 및 안경 착용여부가 영상의 특성, 프레즌스 그리고 피로도 등에 어떠한 영향을 미치는지 알아보고자 했다. 실험결과 디스플레이와 안경착용의 상호작용효과는 인지된 특성 구성요소 중 입체감과 프레즌스 구성요소 중 시간관여에서 유의미하게 나타났다. 입체감과 시간관여의 경우 모두에서, 3D 영상에서 게임을 플레이했을 경우 안경 미착용자가 착용자 보다 더 잘 인지하는 것으로 나타났다.

  • PDF

A Comparison of the Movements of Circle Contact Lens and Soft Contact Lens with Identical Material on Cornea (써클 콘택트렌즈와 동일 재질 소프트 콘택트렌즈의 각막에서의 움직임 비교)

  • Kim, So Ra;Park, Sang Hee;Joo, Seon-Ok;Lee, Hye Rim;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.27-35
    • /
    • 2012
  • Purpose: The present study was conducted to compare any difference caused by pigmentation in the centrations and movement patterns on the cornea between circle and soft contact lens with identical material and parameters during lens wearing. Methods: Soft and circle contact lenses with identical material and parameters were applied to twenty eyes with normal tear volume for 3 hrs a day during a total of 5 days and then their lens centrations, the moving distances and rotations by repeat blinking were compared. Results: The lens centration beyond the fitting criteria was shown in initial wears of both soft contact lens and circle contact lens. However, the centration of soft contact lens was changed to the pupil center for being suitable to the fitting criteria with longer wearing time. On the other hand, the decentration of circle contact lens in the horizontal direction was still presented even with longer wearing time. The moving distances of soft contact lens and circle contact lens decreased with the expand of lens wearing but were not significantly different between total wearing period and daily wearing time. The rotation of circle contact lens by repeat blinking was significantly different from that of soft contact lens even when the wearing period was extended. Conclusions: We revealed that the lens centration and movement of circle contact lens on cornea were different from those of regular soft contact lens resulting in bigger difference with the expand of wearing period in the study.

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

Effectiveness of Glove for the Prevention of Microbial Contamination during the Dental Clinical Practice (치과 임상실습에서의 장갑의 미생물 오염 차단 효과)

  • Jeong, Sun-Ju;Kim, Jung-In;Kim, Ji-Yeon;Ban, Se-Hee;Um, Ji-Young;Jeong, Moon-Jin;Lim, Do-Seon;Jeong, Soon-Jeong
    • Journal of dental hygiene science
    • /
    • v.14 no.4
    • /
    • pp.537-545
    • /
    • 2014
  • We conducted a study to access the effectiveness of glove and washing hands for the prevention of microbial contamination during the dental clinical practice. Microbial numbers at unwashed hands and gloves were $9.938{\time}10^3(CFU)/ml$, those at washed with soap were $9.44{\time}10^3CFU/ml$ And those at washed with a typical liquid soap including disinfectant, Dettol (Reckitt Benckiser, Slough, SL1 3UH, UK) were $6.58{\time}10^2CFU/ml$. In case of unwashed hand and hand washing with soap had similar microbial numbers and in case of hand washing with Dettol showed a rapid decrease of microbial number. Hand washing with Dettol was effective to prevent microbial contamination than hand washing with soap. Also microbial numbers in all case wearing gloves decreased. It showed effectiveness of gloves for prevention of microbial contamination. In addition to microbial numbers showed a tendency to increase from 3 hours on wearing gloves, the change of new gloves after 3 hours on wearing is necessary to minimize the danger of microbial contamination.

A Study on Wearing Tests of Mastectomy Brassieres with Prostheses (유방절제환자를 위한 보정용 브래지어와 부속물 착장실험연구(III))

  • Hei-Sun Choi;Kyung Mi Lee
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.8
    • /
    • pp.13-21
    • /
    • 2002
  • 본 연구의 목적은 유방절제수술을 받은 여성들을 위해 개발한 다섯 종류의 브래지어와 두 종류의 보정물 유형에 따른 착용감과 쾌적성을 검토하기 위한 것이다. 피험자로는 유방절제시술기간이 3년 이상이며 브래지어 사이즈 85에 컵사이즈 A컵인 여성 세 명을 선정하였다. 실험방법은 보정물을 삽입한 브래지어를 하루에 최소 15시간 이상 연속착용하도록 하고 실험복을 착용한 상태에서 피험자들의 일상과 그에 소요된 시간을 기록하도록 하였으며 이 때 착용한 브래지어와 보정물에 대한 느낌을 5점 척도로 표시하게 하였다. 실험기간은 다섯 종류의 브래지어를 하루에 한 가지씩 정해진 순서대로, 처음 5일은 옥보정물과 함께 착용하도록 하고 그 후 5일은 스펀지 보정물과 함께 착용하도록 하였으며 이러한 순서를 두 번 반복하게 하여 총 20일이 소요되었다. 각각의 피험자들에 대해서는 실험이 진행되는 동안 반복적인 면접을 통하여 진행상황을 기록하였으며 아울러 실험복에 대한 제언을 수렴하여 보다 나은 제품개발을 위한 기본 자료화하였다. 실험결과는 다음과 같다. 1. 브래지어에 있어서는 세 명의 피험자가 일치된 결과를 나타내어 일반적인 브래지어 형태와 가장 유사하면서 어깨 끈과 하변밴드 폭만 약간 넓혀준 실험복이 착용감에서 가장 높은 점수를 받았다. 착용자의 편의를 고려하여 앞트임으로 제작한 실험복의 경우에는 앞으로 구부렸을 때 밴드부분이 꺾이는 현상이 생겼으며 피험자들이 모두 뒤트임에 익숙하여 앞트임 브래지어 착용에 불편함을 나타내었다. 브래지어 착장평가에 있어서는 피험자들의 일상적인 행동이나 보정물의 종류가 영향을 미치지 않는 것으로 나타났다 2. 보정물 평가에 있어서는 모든 피험자가 옥가루 재질의 보정물만으로는 수술부위를 자극하는 느낌이 든다고 하였으나 3mm 두께의 스펀지와 함께 삽입했을 때는 아무런 문제가 없는 것으로 나타났다. 또한 보정물의 무게 조절이 가능하므로 실리콘재질의 보정물에서 쉽게 찾아볼 수 있는 무게에 대한 문제를 제기한 피험자는 없었다. 그러나 스펀지로 제작된 보정물에 대해서는 무게가 너무 가벼워 모든 피험자들이 양 쪽 가슴의 균형이 잘 맞지 않는다고 답하였으며 특히, 운동을 즐기고 활동이 많은 피험자의 경우 스펀지로 제작된 보정물에 대해 큰불만을 표시하였다.

The momentary movement of soft contact lens by blinking : The change of movement depending on wearing time (손목에 의한 소프트콘택트렌즈의 순간적인 움직임 : 착용시간의 증가에 따른 움직임의 변화)

  • Park, Sang-Il;Lee, Youn Jin;Lee, Heum-Sook;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • To investigate the momentary movement pattern of soft contact lens(SCL) depending on wearing time, eight types of soft contact lenses were worn by 10 normal subjects and the momentary movements of SCLs were estimated using by high speed camera(FASTCAM ultima 1024). When the momentary movements of SCLs in the cornea between blinkings were compared after 15 min wearing, the vertical movements of all eight SCLs were about 2 times larger than the horizontal movement but the extent of these movement difference was a function of kinds of SCLs. The momentary moving distance of SCL varied from the kinds of SCLs, which A and B lens, daily wear lens, moved significantly larger distance compared with other SCLs. The momentary movements between blinkings decreased significantly after 8hr wear of SCLs. The extents were different when SCLs were compared with each other, which the reduction range of horizontal and vertical movement was 24.6~60.0% and 20.4~94.3%, respectively. The A, B and C lenses which had relatively higher water content showed the larger movement reduction after SCL wear. This results suggest that wearing SCL for some hours decreases the movement of SCl, which can induce the change of tear flow.

  • PDF