• Title/Summary/Keyword: 차폐효과 측정

Search Result 168, Processing Time 0.031 seconds

A Convergence Study on the Contamination and Disinfection of General X-ray generator Practical Equipment (일반촬영 실습 장비의 오염 및 소독에 관한 융합적 연구)

  • Park, Gyu-Tae;Kim, Dong-Heun;Park, Sang-Hee;Jung, Won-Hee;Kim, So-Yeon;Hong, Hee-Jin;Son, Na-Ra;Nam, Seoul-Hee;Han, Man-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 2020
  • It is going to select one X-ray generating device for diagnosis in a radiography laboratory at K university in Gangwon-do to detect bacteria on the surface contamination of tables, IP cassettes, and lead gowns for medical radiation shielding and to inform students of the need for proper disinfection control and hand hygiene. Then disinfection was carried out with tissue, tissue cleaner and 70% alchol and immediately collected with sterile cotton swabs to assess the contamination distribution status and disinfection effects of the surface. The results of measuring the degree of contamination on the surface showed that the largest number of bacteria were detected in Apron, and the evaluation of the disinfection effects according to surface contamination showed a noticeable effect at 70% Alcohol in IP Cassette, and the disinfection effect was the same for Apron. Therefore, in order to prevent bacterial infections among students, basic hand washing and regular disinfection should be performed before the practice to prevent infection.

Recognition of Seawater Intrusion Using Reference IP Technique (참조채널 유도분극탐사기술에 의한 해수침투대 인지)

  • Lee, Sang-Kyu;Hwang, Hak-Soo;Hwang, Se-Ho;Park, In-Hwa;Shin, Je-Hyun
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.1
    • /
    • pp.56-63
    • /
    • 2002
  • Tracing the history of study, problems of seawater intrusion are commonly investigated with electrical techniques because seawater saturated zone is indicative of the low resistivity anomaly. There we, however, silt and mud layers in the western and southern coastal areas of Korea, so we may make a mistake in case we determine seawater intrusion only with resistivity survey. Hence, reference IP survey was carried out in Kimje, Jeollabuk-Do and Youngkwang, Jeollanam-Do in order to decide whether or not the area is under the influence of seawater intrusion. With the use of a electric field cable to minimize EM coupling, we obtained more accurate results by appling reference If technique measuring simultaneously wavelet of current as well as potential. With the aid of reference IP technique, it is possible that we can exactly evaluate seawater intrusion by discriminating seawater saturated area (no IP effect) from very highly conductive layer composed of clay mineral (high IP effect).

Reflection Properties of SiO2/ITO Transparent and Conductive Thin Films for Display (디스플레이용 SiO2/ITO 투명전도막의 반사특성)

  • Shin, Yong-Wook;Kim, Sang-Woo;Yoon, Ki-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.3
    • /
    • pp.233-239
    • /
    • 2002
  • Reflection properties of $SiO_2$/ITO (Indium Tin Oxide) thin films coated for electromagnetic shielding, anti-static and anti-reflection on the front surface in CRT were studied. The behavior of reflectance as a function of thickness of $SiO_2$/ITO was investigated and applied to theoretical anti0reflection model of double layers and three layers. As the thickness of ITO layer increased, the deviation from theoretical value increased because uniformity of film deteriorated by pore. Because of the effect of mixed layer of $SiO_2$ and ITO, experimental reflectance showed better acceptance to the three layer antireflection model of $SiO_2$/$SiO_2$+ITO/ITO than the two layer model. Based on the theoretical antireflection design, the double layer whose thickness of $SiO_2$ and ITO were 90, 65 nm, respectively appear 2.5% in reflectance at standard wavelength, 550 nm. This phenomenon was similar to theoretical reflectance in visual range.

The Characteristic and Control of Contaminant Transport through the Subsurface of Nanjido Landfill (난지도 매립장 지반을 통한 오염이동 특성과 제어)

  • 장연수;이광열
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 1994
  • The contaminant migration through the subsurface of Nanjido landfill is studied using a 2-D finite element model of contaminant transport. The leachate mounding caused by the installation of partial slurry wall around the pheriperal area of the Landfill is analysed using the finite difference model of groundwater flow. Model parameters were validated using in-situ concentration data and the behavior of the transport next 30 years is predicted. The sensitivities of chloride concentration by the change of model parameters, e.g. leachate mounding in the Landfill and the dispersivity are analysed. The results of the analyses show that the maximum chloride concentration level near Han River caused by the leachate of Nanjido Landfill would be 1488mg/1 and comes 17 years after the landfill closure. Increase of the leachate concentration is caused by the increase of both the leachate mounding and the dispersivity. However, the rate of concentration increase becomes higher with the rise of leachate mounding level, while it tends to converge a certain concentration with the increase of the dispersivity.

  • PDF

A Very Compact 60 GHz LTCC Power Amplifier Module (초소형 60 GHz LTCC 전력 증폭기 모듈)

  • Lee, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.11 s.114
    • /
    • pp.1105-1111
    • /
    • 2006
  • In this paper, using low-temperature co-fired ceramic(LTCC) based system-in-package(SiP) technology, a very compact power amplifier LTCC module was designed, fabricated, and then characterized for 60 GHz wireless transmitter applications. In order to reduce the interconnection loss between a LTCC board and power amplifier monolithic microwave integrated circuits(MMIC), bond-wire transitions were optimized and high-isolated module structure was proposed to integrate the power amplifier MMIC into LTCC board. In the case of wire-bonding transition, a matching circuit was designed on the LTCC substrate and interconnection space between wires was optimized in terms of their angle. In addition, the wire-bonding structure of coplanar waveguide type was used to reduce radiation of EM-fields due to interconnection discontinuity. For high-isolated module structure, DC bias lines were fully embedded into the LTCC substrate and shielded with vias. Using 5-layer LTCC dielectrics, the power amplifier LTCC module was fabricated and its size is $4.6{\times}4.9{\times}0.5mm^3$. The fabricated module shows the gain of 10 dB and the output power of 11 dBm at P1dB compression point from 60 to 65 GHz.

The Study for Radio Protection According to a Possible Danger of Exposure During dental X-ray Examination (치과 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구)

  • Lim, Cheong-Hwan;Kim, Seung-Chul;Jung, Hong-Ryang;Hong, Dong-Hee;You, In-Gyu;Jeong, Cheon-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.237-244
    • /
    • 2011
  • Generally, X-ray examinations for dentistry use low energy radiation. It explains that the radiations are mainly absorbed to a human body because of the weak permeability. We made up some counterplans for decrease in radiation exposure, when guardians and radiologists are overexposed owing to unavoidable circumstances. The equipments for the test are GX-770 and CRANEX TOME CEPH which are used for various exams. Besides we measured the radiations in the projection room and in the control room using model 2026c and 20X6-1800. According to the test, the measurement value in the control room was low dose below $20{\mu}R$, the maximum dose in the projection room was $702.8{\mu}R$ and the measurement value of back dose was higher than lateral one. As the result, if we use a shielding door, it's effective for radioprotection and when we didn't prepare protectors, we should secure appropriate distance and be situated at the side area($90{\sim}135^{\circ}$) on the basis of centeral radiation. That way will provide valuable aid for radioprotection.

Fabrication of Backscatter Electron Cones for Radiation Therapy (산란전자선을 이용한 강내측방조사기구의 제작과 특성)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.74-80
    • /
    • 2001
  • Purpose : Irradiation cones by using backscatter electrons are made for the treatment of superficial small lesions of skin, oral cavity, and rectum where a significant dose gradient and maximum surface dose is desired. Methods and Materials : Backscatter electrons are produced from the primary electron beams from the linear accelerators. The design consists of a cylindrical cone that has a thick circular plate of high atomic number medium (Pb or Cu) attached to the distal end, and the plate can be adjusted the reflected angle. Primary electrons strike the metal plate perpendicularly and produce backscatter electrons that reflect through the lateral hole for treatment. Using film and a parallel plate ion chamber, backscatter electron dose characteristics are measured. Results : The depth dose characteristic of the backscatter electron is very similar to that of the hard x-ray beam that is commonly used for the intracavitary and superficial lesions. The basckscatter electron energy is nearly constant and effectively about 1.5 MeV from the clinical megavoltage beams. The backscatter electron dose rate of $35\~85\;cGy/min$ could be achieved from modern accelerators without any modification. and the depth in water of $50\%$ depth dose from backscatter electron located at 6mm for $45^{\circ}$ angled lead scatter. The beam flatness is dependent on the slit size and the depth of treatment, but is satisfactory to treat small lesions. Conclusions : The measured data for backscatter electron energy, depth dose flatness dose rate and absolute dose indicates that the backscatter electrons are suitable for clinical use.

  • PDF

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

A study of Brachytherapy for Intraocular Tumor (안구내 악성종양에 대한 저준위 방사선요법에 관한 연구)

  • Ji, Gwang-Su;Yu, Dae-Heon;Lee, Seong-Gu;Kim, Jae-Hyu;Ji, Yeong-Hun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.19-27
    • /
    • 1996
  • I. Project Title A Study of Brachytherapy for intraocular tumor II. Objective and Importance of the project The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. III. Scope and Contents of the project In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models IV. Results and Proposal for Applications The result were as followed. 1. Eye model was determined as a 25mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15mm, 17mm and 20mm in diameter, and 1.5mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ${\pm}10\%$ and distance deviations are within 0.4mm Maximum error is $-11.3\%$ and 0.8mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192 seeds.

  • PDF

The Measurements of Energy and Distribution of Scattered Electrons in Therapeutic X-Ray Beam (치료 방사선 선속(Flux)에 포함된 산란전자의 분포와 에너지 측정)

  • Vahc, Young-Woo;Park, Kyung-Ran;Ohyun Kwon;Lee, Yong-Ha;Kim, Tae-Hong;Kim, Sookil
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • Accurate knowledge of the distribution of contamination electrons ( which comes from mainly gantry head by Compton scattering, pair production, and tray: henceforth called leptons ) at the surface and in the first centimeters of tissue is essential for the clinical practice of radiation oncology. Such lepton tends to reduce or eliminate the ‘skin-sparing’ advantage of megavoltage photon beam radiotherapy, This information is needed to prescribe a absorbed dose to a skin volume at a few millimeter depth in high energy therapeutic radiation photon beam All experiments were done with 15 MV photon beam from a dual energy linear accelerator (Clinac 1800, Varian). Field size is defined by ranged from 10.0$\times$10.0 to 30.0$\times$30.0 $\textrm{cm}^2$. The absorbed dose and distribution of leptons in therapeutic radiation beam (15 MV) are investigated by means of variable blocked beams of 30.0$\times$30.0 $\textrm{cm}^2$ and dose beam profiles partly removed leptons with a copper plate. A numerous leptons mainly are distributed as shape of broad cone in the central photon beam and leptons path length in the water are shorter than 2.5 cm because of the leptons energy having around 3.0 MeV. These results clearly appears that the subtraction of leptons from the total depth dose curve not only lower the absolute dose in the buildup region and surface dose, it also causes a shift of d$_{max}$ to a deeper depth.

  • PDF