• Title/Summary/Keyword: 차지펌프

Search Result 76, Processing Time 0.025 seconds

Minimization of Pump Running Cost in the Large-scale Water Supply System (광역상수도 계통의 Pump 운전비용 최소화)

  • Lee, Gwang-Man;Kang, Shin-Uk;Kim, Soo-Myung
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.9
    • /
    • pp.759-771
    • /
    • 2009
  • The electricity cost of pumping system accounts for a large part of the total operating cost for long distance water supply networks. This study presents a method based on dynamic programming for establishing an joint optimal operation of pumps and storages system on a hourly basis. Analysis is taken of the relative efficiencies of the available pumps, the structure of the electricity tariff, the consumer-demand pattern, and the storage characteristics and operational constraints of the pipe. The possible system objectives and constraints are described. An application of the method to the existing Yangju Water Supply System consisted of two pump station and 5 storage pools under the condition of expanding pumping facility in the part of the Capital Area Water Supply System is presented, showing that considerable electricity cost savings are remarkable. The approach was found to be implementable in real system operation and large-scale water supply system design in respect of minimizing life-cycle total cost.

Analysis and Design of Hybrid Electromagnetic Linear Actuator for Linear Pump (리니어 펌프 구동용 하이브리드 전자기 리니어 엑츄에이터 해석 및 설계)

  • Lee, Jung-Hun;Kim, Jin-Ho;Lee, Jae-Yong;Jeong, Sang-Hyun;Han, Bang-Woo
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.1
    • /
    • pp.28-33
    • /
    • 2010
  • The purpose of this paper is to analyze and design a new hybrid electromagnetic linear actuator for linear pumps. Solenoid linear actuator is widely used because it occupies small space due to no mechanical energy conversion system. In addition, the energy loss is very low and it has no noise. Conventional solenoid linear actuator, however, has the critical drawback of high power consumption. In this research, we present a new hybrid electromagnetic linear actuator using a permanent magnet in order to reduce power consumption. The enhanced performance of the hybrid linear actuator was verified by dynamic finite element analysis.

Boost converters including PV system with Differential power processor applying Isolated type buck converter (절연형 벅 컨버터가 적용된 승압형 태양광 피드백 차동전력조절기)

  • Lee, Chun-Gu;Park, Joung-Hu
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.347-348
    • /
    • 2016
  • 본 논문에서는 차동전력조절기회로가 적용된 승압형 태양광 차지펌프 플라이백 전하 균등화 회로를 사용하여 연속 모드로 동작하는 전하 균등화 방법을 제안한다. 이 컨버터는 차동전력조절기회로의 입력부에 커패시터가 병렬로 연결되어 있어서 포워드 컨버터가 아닌 벅 컨버터로 동작을 한다. 이로 인하여 기존 포워드 컨버터가 갖고 있는 동작 한계점을 극복할 수 있다. 즉 차동전력조절기회로의 듀티 비가 부스트 회로의 듀티 비 보다 작을 필요가 없다. 또한 실제 현장에 적용할 때 문제가 되는 긴 라인으로 인한 기생 인덕턴스 발생 시 차동전력조절기회로의 스위치에 큰 스파이크가 발생 할 수 있는데 이를 커패시터가 흡수하는 장정을 갖는다.

  • PDF

A Fast Locking Phase Locked Loop with Multiple Charge Pumps (다중 전하펌프를 이용한 고속 위상고정루프)

  • Song, Youn-Gui;Choi, Young-Shig;Ryu, Ji-Goo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.2
    • /
    • pp.71-77
    • /
    • 2009
  • A novel phase-locked loop(PLL) architecture with multiple charge pumps for fast locking has been proposed. The proposed PLL has three charge pumps. The effective capacitance and resistance of the loop filter can be scaled up/down according to the locking status by controlling the direction and magnitude of each charge pump current. The fast locking PLL that changes its loop bandwidth through controlling charge pumps depending on locking status has been designed. The capacitor usually occupying the larger portion of the chip is also minimized with the proposed scheme. Therefore, the PLL size of $990{\mu}m\;{\times}\;670{\mu}m$ including resistors and capacitors at the bandwidth of 29.9KHz has been achieved. It has been fabricated with 3.3V $0.35{\mu}m$ CMOS process. The locking time is less than $6{\mu}s$ with the measured phase noise of -90.45dBc/Hz @1MHz at 851.2MHz output frequency.

A VPP Generator Design for a Low Voltage DRAM (저전압 DRAM용 VPP Generator 설계)

  • Kim, Tae-Hoon;Lee, Jae-Hyung;Ha, Pan-Bong;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.776-780
    • /
    • 2007
  • In this paper, the charge pump circuit of a VPP generator for a low voltage DRAM is newly proposed. The proposed charge pump is a 2-stage cross coupled charge pump circuit. The charge transfer efficiency is improved, and Distributed Clock Inverter is located in each charge pump stage to reduce clock period so that the pumping current is increased. In addition, the precharge circuit is located at Gate node of charge transfer transistor to solve the problem which is that the Gate node is maintained high voltage because the boosted charge can't discharge, so device reliability is decreased. The simulation result is that pumping current, pumping efficiency and power efficiency is improved. The layout of the proposed VPP generator is designed using $0.18{\mu}m$ Triple-Well process.

  • PDF

A Charge Pump Design with Internal Pumping Capacitor for TFT-LCD Driver IC (내장형 펌핑 커패시터를 사용한 TFT-LCD 구동 IC용 전하펌프 설계)

  • Lim, Gyu-Ho;Song, Sung-Young;Park, Jeong-Hun;Li, Long-Zhen;Lee, Cheon-Hyo;Lee, Tae-Yeong;Cho, Gyu-Sam;Park, Mu-Hun;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1899-1909
    • /
    • 2007
  • A cross-coupled charge pump with internal pumping capacitor, witch is advantages from a point of minimizing TFT-LCD driver IC module, is newly proposed in this paper. By using a NMOS and a PMOS diode connected to boosting node from VIN node, the pumping node is precharged to the same value each pumping node at start pumping operation. Since the lust-stage charge pump is designed differently from the other stage pumps, a back current of pumped charge from charge pumping node to input stage is prevented. As a pumping clock driver is located the font side of pumping capacitor, the driving capacity is improved by reducing a voltage drop of the pumping clock line from parasitic resistor. Finally, a layout area is decreased more compared with conventional cross-coupled charge pump by using a stack-MIM capacitors. A proposed charge pump for TFT-LCD driver IC is designed with $0.13{\mu}m$ triple-well DDI process, fabricated, and tested.

A Fluid Analysis Study on Centrifugal Pump Performance Improvement by Impeller Modification (원심펌프 회전차 Modification시 성능개선에 관한 유동해석 연구)

  • Lee, A-Yeong;Jang, Hyun-Jun;Lee, Jin-Woo;Cho, Won-Jeong
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • Centrifugal pump is a facility that transfers energy to fluid through centrifugal force, which is usually generated by rotating the impeller at high speed, and is a major process facility used in many LNG production bases such as vaporization seawater pump, industrial water and fire extinguishing pump using seawater. to be. Currently, pumps in LNG plant sites are subject to operating conditions that vary depending on the amount of supply desired by the customer for a long period of time. Pumps in particular occupy a large part of the consumption strategy at the plant site, and if the optimum operation condition is not available, it can incur enormous energy loss in long term plant operation. In order to solve this problem, it is necessary to identify the performance deterioration factor through the flow analysis and the result analysis according to the fluctuations of the pump's operating conditions and to determine the optimal operation efficiency. In order to evaluate operation efficiency through experimental techniques, considerable time and cost are incurred, such as on-site operating conditions and manufacturing of experimental equipment. If the performance of the pump is not suitable for the site, and the performance of the pump needs to be reduced, a method of changing the rotation speed or using a special liquid containing high viscosity or solids is used. Especially, in order to prevent disruptions in the operation of LNG production bases, a technology is required to satisfy the required performance conditions by processing the existing impeller of the pump within a short time. Therefore, in this study, the rotation difference of the pump was applied to the ANSYS CFX program by applying the modified 3D modeling shape. In addition, the results obtained from the flow analysis and the curve fitting toolbox of the MATLAB program were analyzed numerically to verify the outer diameter correction theory.

A Study of the Velocity Distribution and Vorticity Measurement in the Pump Sump Using PIV (PIV를 이용한 흡수조 내 유속분포 및 와류강도 측정에 대한 연구)

  • Byeon, Hyun Hyuk;Kim, Seo Jun;Yoon, Byung Man
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.145-156
    • /
    • 2020
  • The climate change occurring all over the world increases the risk, specially in urban area, Accordingly, rainwater pumping station expansion is required than before. In order to increase the efficiency of the rainwater pumping station, the analysis of flow characteristics in the pump sump is needed for vortex control. Many efforts have been made to illuminate the vortex behavior using PIV, but any reliable results have not been obtained yet, because of the limitations in image capturing and dependency of measured velocity values on the interrogation area and time interval used for velocity calculation. In this study, therefore, experiments were carried out to find out the limitation of PIV and estimate the validation of the velocity values associated with the analysis parameters such as interrogation area, time interval, grid size. For the experimental condition used in this study, the limitation of PIV and the effects of parameters on the velocity estimation are presented.

A design on low-power and small-area EEPROM for UHF RFID tag chips (UHF RFID 태그 칩용 저전력, 저면적 비동기식 EEPROM 설계)

  • Baek, Seung-Myun;Lee, Jae-Hyung;Song, Sung-Young;Kim, Jong-Hee;Park, Mu-Hun;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2366-2373
    • /
    • 2007
  • In this paper, a low-power and small-area asynchronous 1 kilobit EEPROM for passive UHF RFID tag chips is designed with $0.18{\mu}m$ EEPROM cells. As small area solutions, command and address buffers are removed since we design asynchronous I/O interface and data output buffer is also removed by using separate I/O. To supply stably high voltages VPP and VPPL used in the cell array from low voltage VDD, Dickson charge pump is designed with schottky diodes instead of a PN junction diodes. On that account, we can decrease the number of stages of the charge pump, which can decrease layout area of charge pump. As a low-power solution, we can reduce write current by using the proposed VPPL power switching circuit which selects each needed voltage at either program or write mode. A test chip of asynchronous 1 kilobit EEPROM is fabricated, and its layout area is $554.8{\times}306.9{\mu}m2$., 11% smaller than its synchronous counterpart.

The estimating method of construction workable-quantity per unit time - Focused on Pump-Dredge - (건설기계 시간당작업량(Q) 산정 개선방안 -펌프준설선 작업효율(E)을 중심으로-)

  • Ahn, Bang-Ryul;Tae, Yong-Ho;Suh, Sang-Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.3
    • /
    • pp.125-133
    • /
    • 2010
  • Although work-efficiency of construction machinery is a critical factor for estimating its workable-quantity perunit time, the efficiency figure table presented in the Poom-Sam that is used for Construction Cost Estimation of public sectors in Korea is very subjective for practical usage. In order to suggest objective work-efficiency table for a Pump-Dredger, domestic and overseas documentary records were investigated and on-going construction sites were also visited. Moreover, actual work quantities collected from the site visits were compared with the ones calculated based on the Standard Measurement Methods used in Japan. The research found that the table can be revised by means of detailing down by several factors, namely project type, depth of soil, undersea-site shape, and condition on the sea for better estimation of its workable-quantity. The research will be the foundation for applying the rapid development of Construction Equipment and technology to the appropriate cost estimations and the ground work of related studies.