• Title/Summary/Keyword: 차원감소

Search Result 2,309, Processing Time 0.024 seconds

An Assessment of the Accuracy of 3 Dimensional Acquisition in F-18 fluorodeoxyglucose Brain PET Imaging (3차원 데이터획득 뇌 FDG-PET의 정확도 평가)

  • Lee, Jeong-Rim;Choi, Yong;Kim, Sang-Eun;Lee, Kyung-Han;Kim, Byung-Tae;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Seong-Wun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.327-336
    • /
    • 1999
  • Purpose: To assess the quantitative accuracy and the clinical utility of 3D volumetric PET imaging with FDG in brain studies, 24 patients with various neurological disorders were studied. Materials and Methods: Each patient was injected with 370 MBq of 2-[$^{18}F$]fluoro-2-deoxy-D-glucose. After a 30 min uptake period, the patients were imaged for 30 min in 2 dimensional acquisition (2D) and subsequently for 10 min in 3 dimensional acquisition imaging (3D) using a GE $Advance^{TM}$ PET system, The scatter corrected 3D (3D SC) and non scatter-corrected 3D images were compared with 2D images by applying ROIs on gray and white matter, lesion and contralateral normal areas. Measured and calculated attenuation correction methods for emission images were compared to get the maximum advantage of high sensitivity of 3D acquisition. Results: When normalized to the contrast of 2D images, the contrasts of gray to white matter were $0.75{\pm}0.13$ (3D) and $0.95{\pm}0.12$ (3D SC). The contrasts of normal area to lesion were $0.83{\pm}0.05$ (3D) and $0.96{\pm}0.05$ (3D SC). Three nuclear medicine physicians judged 3D SC images to be superior to the 2D with regards to resolution and noise. Regional counts of calculated attenuation correction was not significantly different to that of measured attenuation correction. Conclusion: 3D PET images with the scatter correction in FDG brain studies provide quantitatively and qualitatively similar images to 2D and can be utilized in a routine clinical setting to reduce scanning time and patient motion artifacts.

  • PDF

The Early Results of Tricuspid Valvuloplasty with Using the Edwards MC3 Annuloplasty System (Edwards MC3 Annuloplasty System을 이용한 삼첨판 성형술의 조기 성적)

  • Oh, Tak-hyuck;Cho, Joon-Yong;Lee, Jong-Tae;Kim, Gun-Jik;Kim, Dae-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.28-33
    • /
    • 2009
  • Background: Functional tricuspid regurgitation (TR) greater than or equal to a mild grade requires tricuspid valvuloplasty, and tricuspid valvuloplasty with ring annuloplasty has shown good outcomes. We report here on our early experience with the Edwards $MC^3$ annuloplasty system (Edwards LifeSciences, Irvine, CA). Material and Method: From November 2004 to July 2006, 72 patients with tricuspid annular dilatation and TR underwent tricuspid valvuloplasty with using the Edwards $MC^3$ annuloplasty ring. Sixty-eight patients were operated on via median sternotomy and four patients were operated on using robotic assisted minimal invasive thoracotomy. The patient population included 21 males and 51 females and their mean age was $53.9{\pm}12.3$. The mean grade of TR, as assessed by the preoperative echocardiography, was $2.2{\pm}1.0$. The mean NYHA functional class was $3.1{\pm}0.8$. The mean left ventricular ejection fraction was $57.0{\pm}9.9$%. Result: The TR and NYHA functional class, as assessed by postoperative echocardiography, was significantly reduced (mean=$0.4{\pm}0.6$ and $2.0{\pm}0.7$, respectively p<0.001). There was one case of hospital mortality. One patient required permanent pacemaker insertion for third degree atrioventricular block. Conclusion: Our study shows that the Edwards $MC^3$ remodeling ring is easy to implant and it effectively corrects functional TR with excellent clinical and echocardiographic outcomes. Further follow-up and a larger clinical series are required to establish the long-term stability of this repair technique.

Numerical Simulation on Seabed-Structure Dynamic Responses due to the Interaction between Waves, Seabed and Coastal Structure (파랑-지반-해안구조물의 상호작용에 기인하는 해저지반과 구조물의 동적응답에 관한 수치시뮬레이션)

  • Lee, Kwang-Ho;Baek, Dong-Jin;Kim, Do-Sam;Kim, Tae-Hyung;Bae, Ki-Seong
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.1
    • /
    • pp.49-64
    • /
    • 2014
  • Seabed beneath and near the coastal structures may undergo large excess pore water pressure composed of oscillatory and residual components in the case of long durations of high wave loading. This excess pore water pressure may reduce effective stress and, consequently, the seabed may liquefy. If the liquefaction occurs in the seabed, the structure may sink, overturn, and eventually fail. Especially, the seabed liquefaction behavior beneath a gravity-based structure under wave loading should be evaluated and considered for design purpose. In this study, to evaluate the liquefaction potential on the seabed, numerical analysis was conducted using 2-dimensional numerical wave tank. The 2-dimensional numerical wave tank was expanded to account for irregular wave fields, and to calculate the dynamic wave pressure and water particle velocity acting on the seabed and the surface boundary of the structure. The simulation results of the wave pressure and the shear stress induced by water particle velocity were used as inputs to a FLIP(Finite element analysis LIquefaction Program). Then, the FLIP evaluated the time and spatial variations in excess pore water pressure, effective stress and liquefaction potential in the seabed. Additionally, the deformation of the seabed and the displacement of the structure as a function of time were quantitatively evaluated. From the analysis, when the shear stress was considered, the liquefaction at the seabed in front of the structure was identified. Since the liquefied seabed particles have no resistance force, scour can possibly occur on the seabed. Therefore, the strength decrease of the seabed at the front of the structure due to high wave loading for the longer period of time such as a storm can increase the structural motion and consequently influence the stability of the structure.

A Study on Trust and Commitment between Buyer and Supplier of Industrial Parts, and Their Usage of Information Technology (산업재 부품 구매자와 공급자의 신뢰와 몰입, 그리고 정보기술의 이용에 관한 연구)

  • Kim, Jong-Hun;Yun, Hui-Taek
    • Proceedings of the Korean DIstribution Association Conference
    • /
    • 2006.08a
    • /
    • pp.47-68
    • /
    • 2006
  • This study aims to determine the association structure of the behavioral relationship variables, such as trust, commitment, cooperation, communication and coercive power, in the relationship between the buyers and suppliers of industrial parts. It also investigates the impact of the use of IT technologies on the relationships quality. Data was collected from 216 part suppliers of machinery, electronics and automobiles located in Incheon. Data supported all of the proposed hypotheses. First, it was confirmed that parts suppliers' trust in buyers leads to the commitment into relationships with buyers. Second, cooperation and communication showed a positive influence on parts suppliers' trust in buyers, and coercive power gave a negative influence on trust. Third, the use of IT technologies like Internet and E-Mail between parts suppliers and buyers was verified to have generally a positive influence on the quality of relationships. At the same time, cooperation and communication were confirmed to have a positive influence on each other, and cooperation and coercive power as well as communication and coercive power were confirmed to have negative influence on each other. This study is a pioneering attempt to examine the relationships between suppliers and buyers of industrial parts, and the influence IT technologies on the relationship quality. Also, the findings will be practically much helpful to find how to reinforce the relationships between parts suppliers and buyers.

  • PDF

Binocular Vision Corrective Spectacle Lenses Reduce Visual Fatigue in 3-D Television Viewing (양안시 교정안경의 3차원 텔레비전 시청 중 발생한 안정피로 감소)

  • Yoon, Jeong Ho;Kim, Jae-Do
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.363-369
    • /
    • 2014
  • Purpose: Three-dimensional (3D) displays are very useful in many fields, but induce physical discomforts in some people. This study is to assess symptom type and severity of asthenopia with their habitual distance corrective spectacle (HDCS) and their binocular vision corrective spectacle lenses (BVCSL) in people who feel physical discomforts. Methods: 35 adult subjects (ages $32.2{\pm}4.4$ yrs) were pre-screened out of 98 individuals to have the highest symptom/asthenopia scores following 65 minutes of 3D television viewing with HDCS. These 35 individuals were then retested symptom/asthenopia scores during they watched 3D television for 65 minutes at a distance of 2.7 m with wearing BVCSL of horizontal, vertical or base down yoked prisms. A 4-point symptom-rating scale questionnaire (0=no symptom and 3=severe) was used to assess 11 symptoms (e.g., blur, diplopia, etc.) related to visual fatigue/visual discomfort. Distance and near lateral phoria were measured using Howell phoria card and vertical phoria were measured using Maddox rod. Symptoms induced by watching 3D TV were compared between wearing HDCS and BVCSL. Results: Asthenopia in watching 3D TV with wearing BVCS was significantly lower than wearing HDCS at 5, 25, 45, and 65 minutes (all p < 0.001, paired t-tests). In only refractive error power correction power group, all asthenopia was not significantly different between HDCS and BVCSL (all $p{\geq}0.05$, paired t-tests). In prism correction groups for binocular imbalance, symptoms of asthenopia, however, was significantly lower for when wearing BVCSL than when wearing HDCS (all p < 0.05). Conclusions: Correction of phoria/vergence-based binocular vision imbalance can reduce asthenopia during 3D television viewing. An individual with binocular vision imbalance need corrected/compensated glasses with appropriate prisms prior to prolonged viewing of 3D television displays to reduce asthenopia/visual fatigue.

A Study of Dose Stability at Low Monitor Unit Setting for Multiple Irradiated Field (다중 조사면 치료 시 기계적 입력치(MU)에 따른 선량적 안정성에 대한 연구)

  • Kim Joo-Ho;Lee Sang-Gyu;Shin Hyun-Kyung;Lee Suk;Na Soo-Kyung;Cho Jung-Hee;Kim Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.155-160
    • /
    • 2005
  • Purpose : Many authors have been introduced field in field technique and 3-D conformal radiotherapy that increased the tumor dose as well as decreased the dose of abutting critical organ. These technique have multiple beam direction and small beam segments even below 10 MU(monitor unit)for each field. we have confirmed the influence of low MU on dose output and beam stability. Materials and Methods : To study the dose output, the dose for each field was always 90MU, but it divided into different segment size: 1, 2, 3, 5, 10, 15 segments, 90, 45, 30, 18, 9, 6 MU the measurements were carried out for X-ray energy 4 MV, 6 MV, 10 MV of three LINAC(Varian 600C, 2100C, 2100C, 2100C/D), in addition each measurement was randomly repeated three times for each energy. To study the field symmetry and flatness, X-omat V films were irradiated. After being developed, films were scanned and analyzed using densitometer. Results : Influence of low MU on dose is slightly more increase output about $1.2{\sim}2.9%$ in cGy/mu than 90MU, but may not changed beam quality(flatness or symmetry), Output stability depends on dose rate(PRF)rather than beam energy, field size. Conclusion : Presented result are under the limits(out put<3%, flatness<${\pm}3%$, symmetry<2%). The 3 accelerators are safe to use and to perform conformal radiotherapy treatments in small segments, small MU around 10MU. but Even if the result presented here under the limits, continuous adjustments and periodic QA should be done for use of small MU

  • PDF

Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients (유방암 환자의 모의치료, CT 스캔 및 치료 과정에서 발생되는 준비 오차 분석)

  • Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: Although computed tomography (CT) simulators are commonly used in radiation therapy department, many Institution still use conventional CT for treatments. In this study the setup errors that occur during simulation, CT scan (diagnostic CT scanner), and treatment were evaluated for the twenty one breast cancer patients. Materials and Methods: Errors were determined by calculating the differences in isocenter location, SSD, CLD, and locations of surgical clips implanted during surgery. The anatomic structures on simulation film and DRR image were compared to determine the movement of isocenter between simulation and CT scan. The isocetner point determined from the radio-opaque wires placed on patient's surface during CT scan was moved to new position if there was anatomic mismatch between the two images Results: In 7/21 patients, anatomic structures on DRR Image were different from the simulation Image thus new isocenter points were placed for treatment planning. The standard deviations of the diagnostic CT setup errors relative to the simulator setup in lateral, longitudinal, and anterior-posterior directions were 2.3, 1.6, and 1.6 mm, respectively. The average variation and standard deviation of SSD from AP field were 1.9 mm and 2.3 mm and from tangential fields were 2.8 mm and 3.7 mm. The variation of the CLD for the 21 patients ranged from 0 to 6 mm between simulation and DRR and 0 to 5 mm between simulation and treatment. The group systematic errors analyzed based on clip locations were 1.7 mm in lateral direction, 2.1 mm in AP direction, and 1.7 mm in SI direction. Conclusion: These results represent that there was no significant differences when SSD, CLD, clips' locations and isocenter locations were considered. Therefore, it is concluded that when a diagnostic CT scanner is used to acquire an image, the set-up variation is acceptable compared to using CT simulator for the treatment of breast cancer. However, the patient has to be positioned with care during CT scan in order to reduce the setup error between simulation and CT scan.

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON PRODUCED DURING RETRACTION OF FOUR MAXILLARY INCISORS (상악 4절치의 후방견인시 나타나는 현상에 관한 유한요소법적 분석)

  • Cheon, Ok-Jin;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.525-541
    • /
    • 1995
  • This study was designed to investigate force systems and tooth movements produced by retraction archwire during retraction of four maxillary incisors after the maxillary canine retraction into the maxillary first premolar extraction space using the computer-aided three-dimensional finite element method. A three-dimensional finite element model, consisting of 2248 elements and 3194 nodes, was constructed. The model consisted of maxillary teeth and surrounding periodontal membranes, .022'$\times$.028'-slot brackets, and 5 types of retraction archwires(.019'$\times$.025' stainless steel archwire) modeled using the beam elements. The contact between the wire and the bracket slot was modeled using the gap elements because of the non-linear elastic behaviors of the contact between them. The forces and moments, End displacements produced by retraction archwire were measured at various conditions to investigate the difference according to types of loops, magnitudes of activation force, gable angle, and anterior lingual root torque. The results were expressed quantitative and visual ways in the three-dimensional method. The following conclusions can be drawn from this study.1. When the tear-drop loop archwire was activated, the mesio-distal and lingual translational movements of the teeth helped to close the extraction space, but unwanted movements of the teeth including intrusions and extrusions, and rotational movements in each direction occurred. 2. Activation of T-loop archwire compared with those of other types of retraction archwires produced the least translational movements of the teeth helped to space closure and also the least unwanted movements of the teeth. 3. Increasing amount of activation in the tear-drop archwire led not only to increase of translational movements of the teeth helped to space closure, but also to increase of unwanted movements of the teeth. 4. Addition of gable bend in the tear-drop archwire helped anterior teeth to translational movements in the mesio-distal direction, but increased unwanted movements of the teeth 5. Addition of anterior lingual root torque in the tear-drop archwire helped central and lateral incisor to improve their facio-lingual inclination, but increased unwanted movements of the teeth.

  • PDF

Effect of Mediating Variable on the Relationship between Job Stress and Stress Response among Clinical Dental Hygienists (임상치과위생사에서 직무스트레스와 스트레스 반응에 있어 매개요인의 영향)

  • Choi, Ja-Hyeong;Choi, Jun-Seon
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.114-122
    • /
    • 2014
  • The purpose of this study was to analyze the effect of mediating variables on the relationship between job stress and stress response. A survey was conducted to 243 clinical dental hygienists from January 15, 2013 to March 20, 2013 and the data were analyzed using t-test, one-way ANOVA, Pearson's correlation analysis, and hierarchical multiple regression analysis. The subjects who worked in poor working environment, had high level of role conflict and overload and aggressive nature showed high stress responsivity (p<0.01). The variable that showed mediation effect on the relationship between job stress and physical discomfort, depression was shown to be personality type (p<0.05). Also, the variable that showed mediation effect on the relationship between job stress and turnover intention was social support (p<0.05). According to the results, personality type and social support were shown to be important parameters when it came to the relationship between job stress and stress response. Therefore, in order to reduce negative outcomes caused by stress, it is suggested to provide an educational opportunity on self-control management while increasing social support from the organizational and structural level. Especially, it is asked to expand the system that provides encouragement and recognition to feel the sense of achievement in the course of their duty execution.

Utilization of Obosan (Dietary Herbs) I. Effects on Survival, Growth, Feed Conversion Ratio and Condition Factor in Olive Flounder, Paralichthys olivaceus (한방사료 첨가제인 어보산의 효과 I. 넙치의 생존율, 성장, 사료효율 및 비만도에 미치는 영향)

  • 김동수;김종현;정창화;이상윤;이상민;문영봉
    • Journal of Aquaculture
    • /
    • v.11 no.2
    • /
    • pp.213-221
    • /
    • 1998
  • The effects of differen concentrations of Obosan as a feed additive dietary herb were examined on survival rate, growth, feed conversion ration and condition factor in olive flounder (paralichthys olivaceus). Effectiveness of dietary Obosan with optimized concentration for 48 weeks were also observed with regard to growth performances and yields. All groups fed diets containing 0.15, 0.3 and 0.6% of Obosan revealed significantly higher survival rate than control group (P<0.05). Growth, feed conversion ratio and condition factor of olive flounder fed diets containing Obosan were considerably improved when compared to those of controls (P<0.05). The 0.3% of dietary Obosan was proven to be the optimal concentration in all parameters tested. The dietary Obosan (0.3%) for 48 weeks showed significantly higher surval rate than control (P<0.05), and also improved yields in weight gain (19.0% improvement), specific growth rate (4.8%), feed conversion ratio(13.6%) and condition factor (10.8%), significantly (P<0.05).

  • PDF