• Title/Summary/Keyword: 차단 스프링

Search Result 27, Processing Time 0.028 seconds

Effect of Rack Compartment using Barriers on Reducing the Fire Spread (차단막에 의한 랙크 구획화가 화재확산 저감에 미치는 영향)

  • Cho, Gyu-Hwan;Yeo, In-Hwan
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.66-75
    • /
    • 2018
  • A barrier installed within a rack plays a significant role in delaying the initial spread of fire but it can be an obstacle to a ceiling-type sprinkler installed for extinguishing fires and for supplying fire extinguishing water. An in-rack sprinkler and a barrier can be applied at the same time, but a study on a barrier's ability to delay fire spread or its effect on the in-rack sprinkler is needed. Accordingly, this study examined the effect of a barrier on the delay of fire spread and the in-rack sprinkler according to installation conditions through the reduced scale fire test. As a result, the delay in fire spread increased more than four times when a horizontal barrier and a vertical barrier were installed at the same time. The temperature was also increased two to three times with the compartment, resulting in the early operation of the in-rack sprinkler.

Opening Spring Modeling of Current Circuit Breaker Mechanism with respect to Opening Speed using Energy Method (전류 차단기 메커니즘에서 에너지방법을 이용한 차단 속도에 따른 스프링 모델링)

  • Kwon, Byung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.688-692
    • /
    • 2000
  • This study proposed design parameters of opening spring of circuit breaker that cut off the over-current in order to protect the electric device about opening speed using the energy method. We simulated the opening kinetic energy, the potential energy of opening spring and the design parameters of opening spring with respect to opening speed of VCB (Vacuum Circuit Breaker)'s moving contactor which has 24kV 25kA break capacity. From the result of simulation the initial tensional force and the final tensional force of the opening spring chose 107kgf and 282kgf respectively. Through the dynamic analysis using ADAMS, We verified that the opening speed of moving contactor satisfied break capacity of VCB and analyzed opening dynamic characteristics of VCB such as the opening displacement, the opening velocity and the opening acceleration of moving contactor in time domain.

  • PDF

The Effect of the Combined Operation of Sprinkler and Vent Systems on the Smoke Control in a Horizontal Corridor (스프링클러와 배연설비의 통합작동이 수평통로의 연기제어에 미치는 영향)

  • Jeon Heung-Kyun;Choi Young-Sang;Choo Hong-Lok;Jang Jun-Young
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.70-89
    • /
    • 2005
  • Fire scenarios in a space $20.0m\;\times\;4.0m$ floor and 3.0m high were simulated by using computational fluid dynamics program (FDS 4.0.3) to investigate the effect of the combined operation of both sprinkler and vent systems, which are installed for cooling and blocking smoke which propagates beneath the ceiling of a horizontal corridor, on the temperature and smoke density of it. It was shown that the combined operation both sprinkler and vent systems was more effective than each operation for cooling and blocking smoke, the number of operating sprinklers was two because of corner effect of wall, and over-installed sprinklers deteriorated the effect of cooling and blocking smoke. This study showed that the case of two sprinklers and vent flow rate $3.0m^3/s$ in fire scenario was the most effective for cooling and blocking smoke. It was confirmed that the smoke downdrag occurs in operating sprinkler system, and the more smoke droplets produced by increasing fire size, the greater smoke downdrag occurred.

Analysis of Hydraulic Control Characteristics of Powershift Transmission for Agricultural Tractors (농업용 트랙터의 파워시프트 변속시 유압 특성 해석)

  • 정병학;이호상;김경욱
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.07a
    • /
    • pp.66-71
    • /
    • 2002
  • 파워시프트는 동력전달의 단속 없이 변속할 수 있는 변속 방식이다. 기어는 동기 물림식으로 되어 있으며, 유압 클러치를 통하여 주행 중에도 동력의 흐름을 제어할 수 있다. 주요 구성 요소는 동력 흐름을 제어할 수 있는 유압 클러치와 동력을 전달하는 기어 조합이며, 유압 클러치는 피스톤, 리턴 스프링, 디스크, 플레이트 등으로 구성되어 있다. 접속 시에는 유압 피스톤이 리턴 스프링을 압축하며 전진하여 플레이트와 디스크에 수직력을 가하고 이를 결합시켜 동력을 전달한다. 해제 시에는 리턴 스프링에 의하여 피스톤이 후퇴하고 동력이 차단된다. 이때 유압 제어 시스템은 최대 견인 부하에서도 변속을 원활하게 하기 위하여, 클러치 압력을 이용해 변속 중 작동 클러치의 토크를 정교하게 제어한다. (중략)

  • PDF

Study of Spring Modeling Techniques for Kinematic and Dynamic Analysis of a Spring Operating Mechanism for the Circuit Breaker (회로차단기용 스프링조작기의 기구동역학 해석을 위한 스프링모델링 기법 연구)

  • Sohn, Jeong-Hyun;Lee, Seung-Kyu;Kim, Seung-Oh;Yoo, Wan-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.7 s.262
    • /
    • pp.777-783
    • /
    • 2007
  • Since the performance of the circuit breaker mainly depends on the spring operating mechanism, the analysis of the spring operating mechanism is required. The spring, especially closing spring, stores the deformation energy due to the compression and then accelerates the big loads rapidly in the circuit breaker. To accurately carry out the kinematic and dynamic analysis of the circuit breaker, the precise modeling of the spring behavior is necessary. In this paper, the static stiffness of the spring is captured by using the tester. A simple mechanism similar to the spring operating mechanism was designed to generate the release motion of the spring. A high speed camera was used to capture the behavior of the spring. Three types of spring models such as a linear spring model, modal spring model, and nodal spring model are suggested and compared with the experimental results.

Fuzzy Controller Design for Active Vibration Isolation System Using Air-spring (공기스프링을 이용한 능동 방진 시스템의 퍼지 제어기 설계)

  • Yang, Xun;An, Chae-Hun;Jin, Kyong-Bok;Rim, Kyung-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.185-190
    • /
    • 2007
  • In recent days, vibration isolation system is mostly required in precise measurement and manufacturing system to reduce vibration due to external disturbances and internal actuators. Among all the vibration isolation systems, air spring is widely used because of its low resonant frequency and high damping ratio. In this study, we first analyze the passive air-spring system using leveling valve, and then design the active vibration isolation system. Because the non-linearity of pneumatic characteristics, we try to design the fuzzy controller which is better than PID controller at complex and non-linear system, and then compare them both in experiment and simulation.

  • PDF

Improvement of Fatigue-Proof Characteristics of Link Members Under Impact Loadings by a Spring-Actuated Mechanism (스프링구동 메커니즘의 충격 하중을 받는 링크부재의 내피로 특성 향상)

  • 안길영;박상후;이부윤;김원진;오일성
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.4
    • /
    • pp.158-164
    • /
    • 2003
  • The air circuit breaker (ACB) with the spring-actuated mechanism was studied to improve the fatigue-proof characteristics of its link. The low-cycle fatigue fracture phenomenon occurred on the critical link, called h-link, of ACB from the repeated rapid closing and opening operations. To analyze the cause of failure, dynamic FE-analysis on the b-link part of ACB was performed considering tile velocity and acceleration of the links per time as boundary conditions, which were obtained by using ADAMS. Also, the S-N curve obtained by experiments was used to investigate requirement on the fatigue-proof characteristics. Then, to reduce the maximum tensile stress on the h-link, three types of h-link were examined and one of them was selected.

Characteristic Analysis of Permanent Magnetic Actuators for Distribution Circuit Breakers (배전급 차단기용 PMA의 특성 해석)

  • Park, Gook-Nam;Hahn, Sung-Chin
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.838_839
    • /
    • 2009
  • 차단기는 전력계통에서 고장이 발생한 경우, 고장전류가 퍼져나가는 것을 방지하고 고장전류에 의해 계통에 연결된 다른 기기들이 손상을 입는 것을 방지하는 전력기기이다. 그 중 진공 차단기는 친환경성과 우수한 절연특성으로 배전급 중.저압용 차단기로 널리 사용되고 있다. 차단기는 크게 조작부와 차단부로 구분되는데 진공 차단기의 조작부 메커니즘은 스프링 구동방식과 영구자석형 마그네틱 액츄에이터(PMA)를 사용하여 구동하는 방식으로 나뉜다. 본 논문에서는 진공차단기의 조작부인 영구자석형 마그네틱 액츄에이터(PMA)의 개방.투입 유지력과 동작특성을 유한요소법을 이용하여 해석하였다. 정밀한 해석을 위해 물질의 비선형성을 고려하였으며, 외부회로와 결합한 전자계 해석을 하였다.

  • PDF

The analysis of drag in the multi-clutch, Design proposal (다판 클러치의 Drag 분석, 설계 제안)

  • 곽희성;김정훈;정삼석;강영선;남상일
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.134-139
    • /
    • 2003
  • 오늘날 산업용 차량은 대부분 유압식 클러치를 채택하여 사용하고 있다 유압식 클러치는 운전자가 손쉽게 엔진으로부터 동력을 바퀴까지 전달 또는 차단하는 기능을 갖고 있기 때문이다. 차량속도에 대한 운전자의 다양한 요구는 다수의 변속 단수를 갖는 기어트레인이나 연속가변식 변속기(CVT) 원하고 있다. 그 중에 기어단을 단속하는 클러치는 엔진의 회전력과 차량 관성력을 효과적으로 연결 또는 차단을 위해 다수의 마찰판과 유체압력을 이용하여 작동된다. 유압식 클러치는 동작방식에 따라서 유체압력이 작동하면 동력을 전달하는 POSITIVE방식과 자체 탄성 스프링력에 의해서 동력을 전달하는 NEGATIVE방식이 있다. POSITIVE방식 유압식 클러치는 동력전달시 어큐뮬레이터를 이용하여 충격을 줄이고, 부하 변동시 승차감각을 향상할 수 있는 장점이 있다 TRX500 트랙터에 사용되는 유압식 클러치는 POSITIVE방식을 채택하고 있다. (중략)

  • PDF

The research for causes of delayed breaking of circuit-breaker driven by compressed air and solutions (압축공기 조작방식 차단기의 지연차단원인 및 해결방안에 관한 연구)

  • Kim, Woo-Kyum;Kim, Jin-Hwan;Lee, Bok-Hyung;Park, Han-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.104-106
    • /
    • 2007
  • 전력계통의 평상시 전류개폐, 고장구간을 신속히 차단 및 재투입하기 위해 차단기(CIRCUIT BREAKER)를 설치 운영하고 있다. 차단기를 조작방식에 따라 분류해 보면 압축공기압 조작방식과 유압 조작방식, 전동스프링 조작방식으로 크게 나눌 수 있으며 본 연구는 최근에 지속적으로 지연동작을 일으키는 압축공기 조작방식의 문제점 분석과 대책을 마련하고자 한다.

  • PDF