• Title/Summary/Keyword: 차단성

Search Result 2,478, Processing Time 0.03 seconds

Effect of ${\alpha}$-Interferon Treatment on Serum ALT Levels in Patients with Chronic Hepatitis C (만성 C형 간염에 대한 ${\alpha}$-interferon 치료 후 ALT치의 변화)

  • Lee, Heon-Ju
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.190-196
    • /
    • 1993
  • The prognosis of chronic hepatitis C is very variable. In some, the disease is progressive and cirrhosis can develop from chronic hepatitis C. Hepatitis C virus(HCV) may act as a trigger towards hepatocellular carcinoma in patients with cirrhosis. Interferon has been used for the treatment of chronic hepatitis C in abroad, 16 patients with chronic C liver disease were treated with ${\alpha}$-interferon (alfa-2b; "Intron A" Schering Corp. Kenilworth. NJ). All patients were given ${\alpha}$-interferon in subcutaneous doses of 3 million units three times weekly for 1 to 9 months. During therapy, CBC and ALT levels were checked weakly to monthly. After therapy, patients were followed for 1 to 8 months. Among 16 patients treated with ${\alpha}$-interferon, progressive decrease of ALT levels was observed in 14(87.5%). In 11 patients(68.8%), ALT levels fell into the normal range during therapy, and in 9 of 11, within one month after therapy, 6 months after the completion of therapy in 4 of 9 patients(44.4%) whose ALT levels were in the normal range, ${\alpha}$-interferon seems to have effect in controlling disease activity in patients with chronic hepatitis C. But the changes in the usage of ${\alpha}$-interferon, dose and duration, long term follow up and more convenient and simple tests for HCV detection are recommended for the better effect and the exact evaluation on the effect of ${\alpha}$-interferon therapy in patients with chronic hepatitis C.

  • PDF

Comparison of Paraquat Actions on Oxygen Radical Generation and Lipid Peroxidation between Submitochondrial Particle and Microsome of Mouse Liver (Paraquat에 의한 산소 Radical 생성 및 지질과산화 작용의 Mouse 간 Submitochondria Particle과 Microsome에서의 비교)

  • Choi, Jung-Hwan;Kim, Yong-Sik;Park, Jong-Hwan;Chung, Myung-Hee;Yunn, Chong-Ku
    • The Korean Journal of Pharmacology
    • /
    • v.27 no.2
    • /
    • pp.155-166
    • /
    • 1991
  • In order to evaluate a potential role of mitochondria in the mediation of toxicity of paraquat (PQ), submitochondrial particle and microsome of mouse liver were compared by oxygen radical generation and lipid peroxidation. With NADH in submitochondrial particle and NADPH in microsome as electron donors, PQ stimulated production of superoxide anion and $H_2O_2$ in both fractions. Under the same conditions, PQ enhanced the generation of ethylene from methional suggestiong stimulation of OH production by PQ. But these effects by PQ were somewhat lower in submitochondrial particle than in microsome. In addition, lipid peroxidation(measured as MDA production) was stimulated by PQ in both fractions. The stimulation of lipid peroxidation in both fractions seemed to occur by the same mechanism probably through perferryl ion. This was supported by the following findings: i) The lipid peroxidation in both fractions was partially inhibited by SOD and completely inhibited by DETAPAC(an iron chelator) but not by catalase or OH scavenger. ii) Addition of $ADP-Fe^{3+}$ further increased PQ-induced lipid peroxidation but decreased ethylene production from methional suggesting no correlation between OH production and lipid peroxidation. The redox-cycling of PQ in mitochondria appeared to be linked to NADH dehydrogenase, not to CoQ since all of the observed stimulations by PQ in submitochondrial particle were inhibited by p-hydroxymercuribenzoate(a NADH dehydrogenase inhibitor) but not affected by other respiratory chain blockers. The above results demonstrate that redox-cycling properties of PQ leading to oxygen radical generation and lipid peroxidation can also occur in mitochondria in the same manner as in microsome. Therefore, the observed actions of PQ in mitochondria suggest that mitochondria may also contribute to toxicity of this drug in vivo.

  • PDF

General Activity and Stress Response of Rats Following Removal of the Mamillary Bodies (유두체를 떼어버린 흰쥐의 일반활동 및 스트레스에 대한 반응)

  • Kim, Chul;Choi, Hyun;Kim, Chung-Chin;Kim, Jong-Kyu;Kim, Myung-Suk
    • The Korean Journal of Physiology
    • /
    • v.2 no.1
    • /
    • pp.79-88
    • /
    • 1968
  • For the purpose of assessing the influence of the mamillary bodies on the general activity and stress response, mamillary body·damaged rats(mamillary body group), operated control rats, and normal control animals were prepared and 2 experiments were carried out. The mamillary bodies. were damaged electrolytically by passing 0.3 ma d.c. current through stereotaxically implanted electrodes. The operated control group received the same treatment except passage of current. In the 1st experiment, each subject belonging to the mamillary body group .(9 rats) or the operated control group (13 animals) was put individually into an activity cage across which an infrared beam traversed. The number of beam interruptions by the movement of the subject in the cage was. recorded hourly for 48 hours and was regarded as an index of general activity. In the 2nd experiment, each of the mamillary body group (52 animals), the operated control group (45 rats), and the normal control group (37 animals) was further divided into 4 subgroups and the adrenal ascorbic acid content of one of the 4 subgroups was measured before, another subgroup immediately after, a third subgroup 2 hours after, and the remaining subgroup 4 hours after termination of a cold stress ($-10^{\circ}C$ for 1 hour). Following results were obtained: 1. Though the total activities in 48 hours of the mamillary body group and the operated control group were not significantly different, the activities of the malnillary body group for a few hours. at the beginning of the measurement and also in the evenings of both the 1st and the 2nd experimental days were significantly greater than those of the operated control group. 2. Judged by the significant reduction in adrenal ascorbic acid content, the stress response of the mamillary body group was as marked as that of the operated control or the normal control group-immediately after termination of cold exposure. Recovery from the stress was accelerated significantly in the mamillary body group and insignificantly in the operated control group compared with that of the normal control group, the intergroup difference of the former two groups being insignificant. It was inferred from the above results that the mamillary bodies may exert an inconspicuous inhibitory influence upon the central mechanism of general activity, and that the mamillaryies bodies may not be the main seat of the stress mechanism, although more works are desirable to confirm the results.

  • PDF

An Intelligent Intrusion Detection Model Based on Support Vector Machines and the Classification Threshold Optimization for Considering the Asymmetric Error Cost (비대칭 오류비용을 고려한 분류기준값 최적화와 SVM에 기반한 지능형 침입탐지모형)

  • Lee, Hyeon-Uk;Ahn, Hyun-Chul
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.4
    • /
    • pp.157-173
    • /
    • 2011
  • As the Internet use explodes recently, the malicious attacks and hacking for a system connected to network occur frequently. This means the fatal damage can be caused by these intrusions in the government agency, public office, and company operating various systems. For such reasons, there are growing interests and demand about the intrusion detection systems (IDS)-the security systems for detecting, identifying and responding to unauthorized or abnormal activities appropriately. The intrusion detection models that have been applied in conventional IDS are generally designed by modeling the experts' implicit knowledge on the network intrusions or the hackers' abnormal behaviors. These kinds of intrusion detection models perform well under the normal situations. However, they show poor performance when they meet a new or unknown pattern of the network attacks. For this reason, several recent studies try to adopt various artificial intelligence techniques, which can proactively respond to the unknown threats. Especially, artificial neural networks (ANNs) have popularly been applied in the prior studies because of its superior prediction accuracy. However, ANNs have some intrinsic limitations such as the risk of overfitting, the requirement of the large sample size, and the lack of understanding the prediction process (i.e. black box theory). As a result, the most recent studies on IDS have started to adopt support vector machine (SVM), the classification technique that is more stable and powerful compared to ANNs. SVM is known as a relatively high predictive power and generalization capability. Under this background, this study proposes a novel intelligent intrusion detection model that uses SVM as the classification model in order to improve the predictive ability of IDS. Also, our model is designed to consider the asymmetric error cost by optimizing the classification threshold. Generally, there are two common forms of errors in intrusion detection. The first error type is the False-Positive Error (FPE). In the case of FPE, the wrong judgment on it may result in the unnecessary fixation. The second error type is the False-Negative Error (FNE) that mainly misjudges the malware of the program as normal. Compared to FPE, FNE is more fatal. Thus, when considering total cost of misclassification in IDS, it is more reasonable to assign heavier weights on FNE rather than FPE. Therefore, we designed our proposed intrusion detection model to optimize the classification threshold in order to minimize the total misclassification cost. In this case, conventional SVM cannot be applied because it is designed to generate discrete output (i.e. a class). To resolve this problem, we used the revised SVM technique proposed by Platt(2000), which is able to generate the probability estimate. To validate the practical applicability of our model, we applied it to the real-world dataset for network intrusion detection. The experimental dataset was collected from the IDS sensor of an official institution in Korea from January to June 2010. We collected 15,000 log data in total, and selected 1,000 samples from them by using random sampling method. In addition, the SVM model was compared with the logistic regression (LOGIT), decision trees (DT), and ANN to confirm the superiority of the proposed model. LOGIT and DT was experimented using PASW Statistics v18.0, and ANN was experimented using Neuroshell 4.0. For SVM, LIBSVM v2.90-a freeware for training SVM classifier-was used. Empirical results showed that our proposed model based on SVM outperformed all the other comparative models in detecting network intrusions from the accuracy perspective. They also showed that our model reduced the total misclassification cost compared to the ANN-based intrusion detection model. As a result, it is expected that the intrusion detection model proposed in this paper would not only enhance the performance of IDS, but also lead to better management of FNE.

Clinical Analysis of 500 Cases of Coronary Artery Bypass Grafting (관상동맥 우회술 500례의 임상적 고찰)

  • Shin, Yoon-Cheol;Kim, Ki-Bong;Ahn, Hyuk;Chae, Hurn;Rho, Joon-Ryang;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.525-531
    • /
    • 1999
  • Background: We analyzed five hundred patients who underwent either isolated or concomitant coronary artery bypass grafting(CABG) between November 1981 and June 1997. Material and Method: There were 330 males and 170 females with a mean age of 57.4$\pm$8.9 years. To evaluate the preoperative status, we performed electrocardiograghy, echocardiography, MIBI scan, Duplex sonogram, common blood test including CK and LDH and coronary angiography. Result: Preoperative clinical diagnoses were unstable angina in 282 (56.4%), stable angina in 141 (28.2%), postinfarction angina in 58 (11.6%), acute myocardial infarction in 8 (1.6%), variant angina in 7 (1.4%) and failed percutaneous transluminal coronary angioplasty in 4 (0.8%) patients. Preoperative angiographic diagnoses were three-vessel disease in 263 (52.6%), two-vessel disease in 93 (18.6%), one-vessel disease in 71 (14.2%), left main disease in 68 (13.6%), and others in 5 (1.0%) patients. Patients had various risk factors for coronary disease, and the frequency of the risk factors such as hypertension, diabetes and smoking showed increasing tendency year by year. We used saphenous vein grafts in 1143, internal thoracic artery grafts in 442, radial artery graft in 17, and gastroepiploic artery graft in 1 anastomosis. The mean number of grafts was 3.2$\pm$1.2 per patient. Concomitant operations were prosthetic valve replacement or valvuloplasty in 31, coronary endarterectomy and angioplasty in 27, left main coronary angioplasty in 13, carotid endarterectomy in 5, and neurologic problems, bleeding, and perioperative myocardial infarction. The mean follow-up period was 25$\pm$23 months and there were 5 cases of reoperation. Conclusion: We hope that the surgical results would improve with the accumulation of experience, application of new myocardial protection technique, and timely intervention of mechanical assisted devices.

  • PDF

Complete Myocardial Revascularization Utilizing Parallel Secluential Anastomoses (Parallel sequential anastomosis를 이용한 관상동맥 우회수술의 성적)

  • 박계현;김관민
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.647-655
    • /
    • 1997
  • We evaluated the feasibility and safety of this method by reviewing the early outcome of the patients who underwent coronary artery bypass grafting(CABG) utili ing parallel sequential anastomoses with saphenous vein grafts, comparing with the outcome of the patients revascularized with grafts having only single distal anastomosis. During the one-year period of 1995, a total of 79 patients underwent isolated CABG, among whom 39 patients with sequential vein grafts(sequential group) and 40 patients without sequential grafts(non-sequential group). There was no difference between the two groups in terms of preoperative status, except in the extent of the coronary disease; 87.2% of the sequential group and 45.0% of the non-sequential group had left main andlor triple vessel involvement. 318 distal coronary anastomoses were done; 198 for the sequential group(5.1/patient) and 120 for the non-sequential group(3.0/patient). In the sequential group, the mean durations of cardiopulmonary bypass and aortic clamp per one distal anastomosis were 33.5 and 21.1 minutes, respectively. In the non-sequential group, these were 41.8 and 22.7 minutes. There were two operative deaths, both in the non-sequential group. There was no difference in the incidence of postoperative complications including myocardial infarction. During the follow-up period(2 to 15 months), 8 patients(3 in the sequential and 5 in the nonsequential group) complained of residual or recurrent angina. Comparison of preoperative and postoperative ."'Thallium myocardial perfusion scans in 30 patients showed improved or normal perfusion reserve in 83.3% of segments bypassed with sequential grafts and 82.5% of segments bypassed with non-sequential graft(5), These results show that, utilizing parallel sequential anastomoses with saphenous vein grafts, we could achieve satisfactory short-term clinical results in patients with extensive coronary stenoses. So, we conclude that this technique is a safe, technically feasible strategy for CABG, which can achieve the aim of complete myocardial revascularization with a limited length of graft.raft.

  • PDF

Development of Domestic Rainwater Treatment System and its Application in the Field (소규모 빗물처리시설 개발 및 현장 적용성 평가 연구)

  • Pak, Gijung;Park, Minseung;Kim, Hwansuk;Lim, Yoonsoo;Kim, Sungpyo
    • Journal of Wetlands Research
    • /
    • v.18 no.1
    • /
    • pp.24-31
    • /
    • 2016
  • The increase of impervious area in cities caused the unbalanced water cycle system and the accumulated various contaminants, which make troubles as introducing into watershed. In Korea, most of rainfall in a year precipitate in a summer season. This indicate that non-point source pollution control should be more important in summer and careful rainfall reuse strategy is necessary. Accordingly, the aim of this study is to monitor the characteristics of rainfall contaminants harvested in roofs and to develop the rainfall treatment system which are designed to fit well in a typical domestic household including rain garden. The rain garden consists of peatmoss, gravel and san to specially treat the initial rainfall contaminants. For this purpose, lab scale experiments with synthetic rainfall had been conducted to optimize the removal efficiency of TN, TP and CODcr. After lab scale experiments, field scale rainfall treatment system installed as a pilot scale in a field. This system has been monitored during June to July in 2015 in four time rainfall events as investigating the function of time, rainfall, and pollutant concentrations. As results, high loading of pollutants were introduced to the rainfall treatment system and its removal efficiency is increased as increase of pollutant concentrations. Since it is common that the mega-size of rainfall treatment system is not attractive in urban area, small scale rainfall treatment system is promising to treat the non-point source contaminants from cities. In addition, this small scale rainfall treatment system could have a potential to water resue system in islands, which usually suffer the shortage of water.

Development of High-performance Microwave Water Surface Current Meter for General Use to Extend the Applicable Velocity Range of Microwave Water Surface Current Meter on River Discharge Measurements (전자파표면유속계를 이용한 하천유량측정의 적용범위 확장을 위한 고성능 범용 전자파표면유속계의 개발)

  • Kim, Youngsung;Won, Nam-Il;Noh, Joonwoo;Park, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.613-623
    • /
    • 2015
  • To overcome the difficulties of discharge measurements during flood season, MWSCM(micowave water surface current meter) which measures river surface velocities without contacting water has been applied in field work since its development. The existing version of MWSCM is for floods so that its applicability is low due to the short periods of floods. Therefore the renovative redesign of MWSCM to increase the applicability was conducted so that it can be applied to the discharge measurements during normal flows as well as flood ones by extending the measurable range of velocity. A newly developed high-performance MWSCM for general use can measure the velocity range of 0.03-20.0 m/s from flood flows to normal flows, whereas MWSCM for floods can measure the velocity range of 0.5-10.0 m/s. The improvement of antenna isolation between transmitter and receiver to block the inflow of transmitted singals to receiver and the improvement of phase noise of oscillator are necessary for detecting low velocity with MWSCM technology. Separate type antenna of transmitting and receiving signals is developed for isolation enhancement and phase locked loop synthesizer as an oscillator is applied to high-performance MWSCM for general use. Microwave frequency of 24 GHz is applied to the new MWSCM rather than 10 GHz to make the new MWSCM small and light for convenient use of it at fields. Improvement requests on MWSCM for floods-stable velocity measurement, self test, low power consumtion, and waterproof and dampproof-from the users of it has been reflected on the development of the new version of MWSCM.

Electrical Stimulation Parameters in Normal and Degenerate Rabbit Retina (정상 망막과 변성 망막을 위한 전기자극 파라미터)

  • Jin, Gye-Hwan;Goo, Yong-Sook
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • Retinal prosthesis is regarded as the most feasible method for the blind caused by retinal diseases such as retinitis pigmentosa (RP) or age related macular degeneration (AMD). Recently Korean consortium launched for developing retinal prosthesis. One of the prerequisites for the success of retinal prosthesis is the optimization of the electrical stimuli applied through the prosthesis. Since electrical characteristics of degenerate retina are expected to differ from those of normal retina, we performed voltage stimulation experiment both in normal and degenerate retina to provide a guideline for the optimization of electrical stimulation for the upcoming prosthesis. After isolation of retina, retinal patch was attached with the ganglion cell side facing the surface of microelectrode arrays (MEA). $8{\times}8$ grid layout MEA (electrode diameter: $30{\mu}m$, electrode spacing: $200{\mu}m$, and impedance: $50k{\Omega}$ at 1 kHz) was used to record in-vitro retinal ganglion cell activity. Mono-polar electrical stimulation was applied through one of the 60 MEA channel, and the remaining channels were used for recording. The electrical stimulus was a constant voltage, charge-balanced biphasic, anodic-first square wave pulse without interphase delay, and 50 trains of pulse was applied with a period of 2 sec. Different electrical stimuli were applied. First, pulse amplitude was varied (voltage: $0.5{\sim}3.0V$). Second, pulse duration was varied $(100{\sim}1,200{\mu}s)$. Evoked responses were analyzed by PSTH from averaged data with 50 trials. Charge density was calculated with Ohm's and Coulomb's law. In normal retina, by varying the pulse amplitude from 0.5 to 3V with fixed duration of $500{\mu}s$, the threshold level for reliable ganglion cell response was found at 1.5V. The calculated threshold of charge density was $2.123mC/cm^2$. By varying the pulse duration from 100 to $1,200{\mu}s$ with fixed amplitude of 2V, the threshold level was found at $300{\mu}s$. The calculated threhold of charge density was $1.698mC/cm^2$. Even after the block of ON-pathway with L-(1)-2-amino-4-phosphonobutyric acid (APB), electrical stimulus evoked ganglion cell activities. In this APB-induced degenerate retina, by varying the pulse duration from 100 to $1200{\mu}s$ with fixed voltage of 2 V, the threshold level was found at $300{\mu}s$, which is the same with normal retina. More experiment with APB-induced degenerate retina is needed to make a clear comparison of threshold of charge density between normal and degenerate retina.

  • PDF

The Role of Cyclooxygenase Metabolites in the Pathogenetic Mechanism of Endotoxin-Induced Acute Lung Injury in Domestic Pigs (내독소에 의한 돼지의 급성 폐손상에서 Cyclooxygenase 대사물의 역할에 관한 연구)

  • Yoo, Chul-Gyu;Jeong, Ki-Ho;Choi, Hyung-Seok;Lee, Hyuk-Pyo;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.1
    • /
    • pp.42-54
    • /
    • 1992
  • Background:It has been suggested that the cyclooxygenase metabolites play an important role in changes of early hemodynamic parameters in the endotoxin-induced acute lung injury. But there have been many debates about their role in the late increase of alveolar-capillary permeability, and it is not known whether they act directly or indirectly through oxygen free radicals which have been known to be produced during the metabolic process of cyclooxygenase pathway. So we performed this study to identify the pathogenetic role of cyclooxygenase metabolites in the endotoxin-induced acute lung injury in domestic pigs. Method: We infused endotoxin into 8 domestic pigs; endotoxin only (n=3), and pretreatment with indomethacin (n=5). We observed the sequential changes in hemodynamic parameters, the concentration of plasma oxidized glutathione (GSSG) in pulmonary arterial and venous blood, and albumin content in bronchoalveolar lavage fluid (BALF). Results: 1) While cardiac output decreased, mean pulmonary arterial pressure, pulmonary vascular resistance, and alveolar-arterial oxygen difference increased over phase 1 (0-2hr) and phase 2 (2-4.5hr) by endotoxin, indomethacin attenuated the decrease in cardiac output during phase 1 and increase in mean pulmonary arterial pressure, pulmonary vascular resistance, and alveolar-arterial oxygen difference during both phases. 2) The increase in plasma GSSG content during phase 2 was not attenuated by indomethacin. 3) The content of BALF albumin was significantly lower in indomethacin groups than that of endotoxin group. Conclusion: These results suggest that it is likely that cyclooxygenase metabolites have an effect on endotoxin-induced acute lung injury during both phases probably through direct action.

  • PDF