• 제목/요약/키워드: 집진기

검색결과 295건 처리시간 0.026초

청정에너지 회수용 유증기/매연 포집모듈에 관한 연구 (A Study on the Oil-mist/Smoke Collecting Module for the Pure Energy Recycling)

  • 김명수;오꾸라 시게노부;함경춘
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.279-284
    • /
    • 2009
  • Traditionally, so-called "industrial waste gases", such ad exhaust from boilers at industrial installations and a large quantity of soot discharged from power station, before their release into the atmosphere, have been on occasion subjected to an air cleaning process to remove fine particles that may pollute the atmosphere (such as mist and dust containing various powdery or oily substances and moisture from industrial waste gases). The release of industrial waste gases containing these particles directly into the atmosphere poses a serious threat to the earth environment; and recovery of these noxious substances is required by law in some countries and local governments. in urban areas, air pollution from automobile exhaust and others creates a serious condition. Some homes are equipped with and use indoor air purifiers. In many of the kitchens of restaurants, smoke generated during cooking and otherwise contaminated air are cleansed by air purifiers before being released outside or recycled inside. For the dust collecting devices to recover the fine particles contained in contaminated air, the cause for air pollution and how to purify air, many types based on various principles are known. Specifically, classified based on theories of particle collection, filtration, gravity, inertia, centrifugation, electricity, and cleaning types are cited as available processes. Among them, an appropriate type is selected according to the size or type of fine particles to be collected and conditions for installation. For the efficiency of dust collection, a filtration system (by using bag filters and others) and electric system are particularly outstanding and are therefore used widely in various areas of industry. In this research, rotary type high performance oil mist and smoke collecting system with self auto cleaning device equipped with the cleaning fluid spraying section is investigated.

  • PDF

고효율 호흡보호구의 나노물질 입경별 제거 효율 (Fractional efficiency of Nanomaterials for the High efficiency respiratory filters)

  • 이광재;지준호;김원근;육세진;김종규;김정호
    • 한국입자에어로졸학회지
    • /
    • 제12권3호
    • /
    • pp.95-102
    • /
    • 2016
  • 본 연구에서는 호흡용 보호구 필터의 나노물질에 대한 여과특성을 측정하기 위해서 소금(NaCl)과 은나노입자(Ag)를 대상으로 입경별 집진효율을 평가하였다. 호흡용 보호구 필터는 특급 방진마스크와 1급 방진마스크의 두 가지 안면부 여과식 방진마스크인 사용하였고, 마스크의 배기밸브 부분을 제외한 필터 여재 부분을 직경 47 mm로 잘라내어 필터홀더에 부착하여 입경별 입자제거효율을 시험하였다. 시험입자는 일반적으로 시험 입자로 사용되는 소금입자는 분무형 입자발생장치를 사용하여 발생하였고 중화기를 통과시켜 입자의 하전특성을 볼츠만 분포로 만들어 공급하였다. 은나노입자의 경우, 기화-응축 방법을 이용한 금속나노입자 생성방법인 ISO10801 방법을 사용하였다. 작업장의 은나노입자의 고농도 노출을 모사하기 위해, 중화기를 통과하지 않은 나노입자를 시험입자로 사용하였다. 은나노입자의 경우 소금입자로 만들기 어려운 20nm 이하의 입자를 안정적으로 효과적으로 만들어 시험에 적용하였고, 나노 크기에서도 매우 안정적인 데이터를 확보할 수 있었다. 1급 마스크 필터와 특급 마스크 필터에 대한 소금입자의 평가에서, 입경별 최소효율이 30~50nm 사이에서 나타나는 특성은 기존 연구와 비슷한 결과를 얻었다. 반면, 은나노입자의 경우 1급 마스크 필터와 특급 마스크 필터 모두에서 비슷한 크기의 소금 입자와 비교할 때 높은 효율을 나타냈다. 이것은 소금 입자의 경우 중화기를 통과시켜 시험입자로 사 용한 반면, 은나노입자의 경우 중화기를 통과시키지 않았기 때문이다. 본 연구에서는 작업장에서 은나노 입자가 고농도로 노출될 경우를 모사하여, 기화-응축에 의한 방법의 은나노입자 발생장치를 사용하였는데, 이 때 상대적으로 높게 대전된 입자들이 많이 만들어진다(Jung et al., 2006). 이로 인해, 정전필터인 마스크 필터의 포집 효과가 상대적으로 크기 때문에, 입경별 효율이 높아진 것으로 생각된다. 본 연구에서 평가한 1급 및 특급 방진마스크 여재의 최소 포집효율은 유럽 EN 149 기준인 95 LPM 유량 기준을 만족하는 것으로 나타났지만, 이것은 여재에 대한 평가 결과로, 실제 마스크에 대해서는 여재의 구조적인 불균일성이나 마스크를 착용하는 과정에서 밀착이 되지 않아 누출될 가능성은 마스크 사용에 고려되어야 한다. 불시에 발생할 수 있는 작업장 내 안전사고의 예방을 위하여 적절한 보호구의 선택과 올바른 착용 및 유지관리가 필요할 것으로 생각된다.

사각형 여과집진기 충격기류 시스템의 최적탈진조건에 관한 실험적 연구 (Experimental study on the optimum pulse jet cleaning conditions of a rectangular bag-filter system)

  • 박승욱;김태형;이효우;하현철;정재훈
    • 한국산업보건학회지
    • /
    • 제18권3호
    • /
    • pp.189-203
    • /
    • 2008
  • Cylindrical bag filter system with pulse jet cleaning has been the most common device to control particle laden exhaust gas from the various industrial processes. But, it has many shortcomings due to particle reattachment and frequent bag rupture. In recent years, rectangular type bag filter system has been developed to overcome the problems associated with the cylindrical system. However, not many studies about the rectangular system were not done, compared to the cylindrical system. In this study, the optimum pulse jet cleaning conditions were thus tested by the series of experiments. The factors tested in this study are pulse distance, pulse pressure, pulse duration, the number of holes for pulsing and bag materials. A single bag ($1,500mmL{\times}50mmW{\times}300mmH$) system and a multi-bags (3 bags in a row) were tested separately. The highest removal efficiency with a single bag system was found at the conditions with pulse distance of 10cm, pulse pressure of $3kg/cm^2$, pulse duration of 0.3s, pulse jet number of 6 and Polyester bag. With the multi-bags system, the best cleaning conditions were found at the bag interval of 20cm with the simultaneous pulsing and the bag interval of 15cm with the serial pulsing.

에어핸들링 유닛의 공기정화용 전기집진기의 방전극 비교 (Comparison of discharging electrodes for the electrostatic precipitator as an air filtration system in air handling units)

  • 신동호;우창규;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.11-16
    • /
    • 2017
  • Indoor air quality is of increasing concern because it is closely related human health. An air handling unit (AHU) can be used to control the indoor air quality related to particulate matters and $CO_2$ as well as air conditioning such as temperature and humidity of indoor air. An electrostatic precipitator has a high collection efficiency and low pressure drop, however, ozone can possibly generate from its chargers, which is one of drawbacks to apply it for indoor air control. Here we compared four charging electrodes such as a $50{\mu}m$ tungsten wire, a $100{\mu}m$ tungsten wire, a $16{\mu}m$-thickness Al foil and a carbon fabric comprised of $5-10{\mu}m$ fibers. The carbon fabric electrode showed a superior particle collection efficiency and a lower ozone generation at a given power consumption compared to tungsten wires of 50, $100{\mu}m$ and an Al foil electrode. This low ozone generating, micro-sized electrode can be applied to the electrostatic precipitator in AHU for indoor air control.

2단 평행판 전기집진기의 서브마이크론 입자 포집특성 실험 (Experiment on Collection Characteristics of Sub micron Particles in Two-Stage Parallel-Plate Electrostatic Precipitators)

  • 오명도;유경훈
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.237-246
    • /
    • 1994
  • Experimental data are reported for charging and collection of NaCl aerosols in the 0.03- to $0.2{\mu}m$-geometric-mean-diameter range in 2-stage parallel-plate electrostatic precipitators. The NaCl aerosols are generated with geometric standard deviation of about 1.74 and particle generation rate of about 10^9 particles/see by the constant output atomizer and injected into the air flow in the clean wind-tunnel. The 2-stage parallel-plate electrostatic precipitator installed in the test section of the wind-tunnel is operated with a positive corona discharge. The NaCl aerosols in the channel flow are sampled and transported to the aerosol particle number concentration measurement system by using the isoaxial sampling and transport system constructed based on the Okazaki and Willeke design. The aerosol particle number concentration measurement system measures the size distribution of submicrometer aerosols by an electrical mobility detection technique. It is confirmed from comparing the measured collection efficiencies in this study and the predicted ones by our previous theoretical analysis that the predicted collection efficiencies agree well with the experimental ones. It is also found from the comparison that below about $0.02{\mu}m$ all particles are not charged and the uncharged particles are not collected, and consequently 2-stage parallel-plate electrostatic precipitators are not suitable for that particle size range.

  • PDF

디지털 이미지 분석을 이용한 Fly Ash의 원형지수 측정 (Circularity Measurenment of Fly Ash Using Digital Image Processing)

  • 이승헌;김홍주;배승묵;이원준
    • 한국세라믹학회지
    • /
    • 제39권8호
    • /
    • pp.735-741
    • /
    • 2002
  • 미분탄 화력발전소에서 보일러의 부하를 변화시켰을 때 전기집진기에서 단별 채취한 fly ash에 대해서 디지털 이미지 분석을 이용하여 원형지수를 검토하였다. 원형지수 측정은 다음과 같은 다섯 단계, 즉 ① 이미지 획득, ② 이미지 전처리, ③ 검출, ④ 이미지 후처리, ⑤ 측정의 단계를 거쳐 이루어 졌다. Fly ash의 평균 원형지수는 0.78∼0.83의 범위를 나타냈으며, 같은 위치에 있는 호파에서 채취한 fly ash는 보일러의 부하에 관계없이 유사한 원형지수 값을 나타냈다. 그리고 첫 번째 호파에서 세 번째 호파로 갈수록, 즉 fly ash의 평균 입경이 작아질수록 원형지수는 증가하는 경향을 나타냈다.

반도체 클린룸용 배기 열회수식 외기공조시스템의 에너지절감에 관한 실험적 연구 (An Experimental Study on Energy Reduction of an Exhaust Air Heat Recovery Type Outdoor Air Conditioning System for Semiconductor Manufacturing Clean Rooms)

  • 송근수;유경훈;강신영;손승우
    • 설비공학논문집
    • /
    • 제21권5호
    • /
    • pp.273-281
    • /
    • 2009
  • In recent semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems represents about 45% of the total air conditioning load required to maintain a clean room environment. Meanwhile, there is a large amount of exhaust air from a clean room. From an energy conservation point of view, heat recovery from the exhaust air is therefore useful for reducing the outdoor air conditioning load for a clean room. In the present work, an energy-efficient outdoor air conditioning system was proposed to reduce the outdoor air conditioning load by utilizing an air washer to recover heat from the exhaust air. The proposed outdoor air conditioning system consisted mainly of a preheating coil, an air washer, two stage cooling coils, a reheating coil, a humidifier and two heat recovery cooling coils inserted into the air washer and connected to a wet scrubber. It was shown from the lab-scale experiment with outdoor air flow of $1,000\;m^3/h$ that the proposed system was more energy-efficient for the summer and winter operations than an outdoor air conditioning system with a simple air washer.

오픈 소스 전산 유체 역학 해석 프로그램을 이용한 전기집진기 내부 정전 유동 해석 (Numerical Analysis of Electro-Hydrodynamic (EHD) Flows in Electrostatic Precipitators using Open Source Computational Fluid Dynamics (CFD) Solver)

  • 송동근;홍원석;신완호;김한석
    • 한국입자에어로졸학회지
    • /
    • 제9권2호
    • /
    • pp.103-110
    • /
    • 2013
  • The electrostatic precipitator (ESP) has been used for degrading atmospheric pollutants. These devices induce the electrical forces to facilitate the removal of particulate pollutants. The ions travel from the high voltage electrode to the grounded electrode by Coulomb force induced by the electric field when a high voltage is applied between two electrodes. The ions collide with gas molecules and exchange momentum with each other thus inducing fluid motion, electrohydrodynamic (EHD) flow. In this study, for the simulation of electric field and EHD flow in ESPs, an open source EHD solver, "espFoam", has been developed using open source CFD toolbox, OpenFOAM(R) (Open Field Operation and Manipulation). The electric potential distribution and ionic space charge density distribution were obtained with the developed solver, and validated with experimental results in the literature. The comparison results showed good agreement. Turbulence model is also incorporated to simulate turbulent flow; hence the developed solver can analyze laminar and turbulent flow. In distributions of electric potential and space charge, the distributions become distorted and asymmetric as the flow velocity increases. The effect of electrical drift flow was investigated for different flow velocities and the secondary flow in a flow of low velocity is successfully predicted.

여과집진기의 탈진 거동 개선에 관한 연구 (A study on the improvement of cleaning performance in bag-filter)

  • 홍성길;금영호;손병현
    • 한국산학기술학회논문지
    • /
    • 제16권2호
    • /
    • pp.1571-1578
    • /
    • 2015
  • 전산유체역학(CFD)을 이용하여 산업체에 널리 적용되고 있는 충격기류형 탈진시스템의 탈진 특성을 규명하고, 그 성능을 향상시키기 위해 탈진부 유니트(unit) 형상을 개조한 경우의 탈진 성능을 비교하였다. 탈진부 각 형상에 대해 검토한 결과, 블로우 튜브에 노즐을 설치한 경우(Case 3)와 벤츄리에 이중 유입관을 설치한 경우(Case4, 5)가 현재 현장에서 널리 적용되고 있는 구조(Case 1)에 비해 우수한 것으로 예측되었다. 또한 최적 형상의 벤츄리를 설계하고, 이 벤츄리를 pilot plant에서 실험하여 현장 적용성을 분석하였다. 블로우 튜브와 본 연구에서 제안한 벤츄리를 조합한 시스템의 경우, 기존 시스템(블로 튜브만 사용한 경우와 블로 튜브와 벤츄리를 조합한 경우)에 비해 탈진 기류를 집중시키는데 매우 효과적인 것으로 나타났다. 또한 본 연구에서 제안한 벤츄리를 장착하여 테스트한 결과, 산업 현장에서 사용 중인 상용 벤츄리를 사용한 경우 보다 탈진횟수 및 탈진시간이 많이 향상되는 결과를 보였다.

공기부유진내(空氣浮游塵內)의 Radon 붕괴생성물(崩壞生成物)의 농도측정(濃度測定) (Measurement of Radon Daughters in Airborne Dust)

  • 김필수;민덕기;노성기
    • Journal of Radiation Protection and Research
    • /
    • 제2권1호
    • /
    • pp.9-16
    • /
    • 1977
  • 공기부유진내(空氣浮游塵內)에 존재(存在)하는 라돈 붕괴생성물(崩壞生成物) 즉(卽) RaA, RaB및 RaC의 간단(簡單)한 농도측정법(濃度測定法)을 확립(確立)하였다. 이것은 단일집진장치(單一集塵裝置)로 membrane 여과지(濾過紙)(평균(平均) pore size=$0.8{\mu}m$)에 채취(採取)한 시료(試料)의 전(全)알파 방사능(放射能)을 시차별(時差別)로 측정(測定)하므로서 농도(濃度)를 결정(決定)하는 방법(方法)이다. 일연(一聯)의 예비실험(豫備實驗)으로써 이 방법(方法)을 이용(利用)하여 한국원자력연구소(韓國原子力硏究所) 구내(構內)에서 라돈 붕괴생성물(崩壞生成物)의 시간적(時間的) 농도변화(濃度變化)를 측정(測定)하였다. 이들 농도(濃度)의 시간적(時間的) 변화(變化)는 심(甚)하였는데 대개(大槪)의 경우(境遇) 최고치(最高値)는 대기(大氣)의 밀도(密度)가 비교적(比較的) 높은 아침에 나타났고 최고치(最高値)는 기(其) 반대(反對)인 오후(午後)에 나타났다.

  • PDF