• 제목/요약/키워드: 집열효율

검색결과 93건 처리시간 0.021초

여러 가지 종류의 태양열 집열기 작동성능 비교 분석 연구 (The study on the comparison of the operation performance of different type of solar collectors)

  • 김휘동;백남춘;이진국;주문창
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.64.2-64.2
    • /
    • 2010
  • The objective of this study is to make a comparative study of the operation performance of different type of solar collectors. A flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector are used in this study. These 3 type of collectors are connected in series in the order of a flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector. This experimental facility is a kind of a solar system with a controller, a heat exchanger, a storage tank and a circulation pump. Each collector has a different collection area(flat-plate collector-$6.00m^2$ total area/$5.61m^2$ aperture area, double-glazed evacuated collector-$6.04m^2$ total area/$4.92m^2$ aperture area, single-glazed evacuated collector-$7.65m^2$ total area/$5.61m^2$ aperture area) and its performance characteristic respectively. The experiments have been demonstrated at around $70^{\circ}C$ operating temperature(flat-plate collector inlet temperature). The thermal collecting efficiencies of each collector are obtained under the different insolation and operation condition as a result.

  • PDF

태양열 실증시스템의 진공관형 태양열 집열기 장기 열성능 (Long-term thermal performance of evacuated tubular solar collector for demonstration system)

  • 이호;주홍진;윤응상;김상진;곽희열
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.104-110
    • /
    • 2008
  • This paper presents demonstration study results derived through field testing of a part load solar energized cooling system for the library of a cultural center building located in Gwangju, Korea. First operating demonstration system was set up in Gwangju in 2005. These system comprises the $200m^2$ evacuated tubular solar collector, a $6m^3$ heat storage tank. In a 2006, daily average of insolation showed about $506W/m^2$, the solar collector efficiency was 44%. In a 2007, daily average of insolation showed about$507W/m^2$, the solar collector efficiency was 42%. As a result, evacuated tubular solar collector kept the high efficiency for two years.

  • PDF

태양열 이용 냉난방 공조시스템 중 공기식 집열기의 집열효율에 관한 연구 (Study on the Collector Efficiency of an Air Heater in a Solar Air Conditioning System)

  • 김보철;신현준;최광환;금종수
    • 태양에너지
    • /
    • 제20권4호
    • /
    • pp.1-8
    • /
    • 2000
  • The suggested year round solar air conditioning system has been developed for cooling and heating. In particular, this system focused on cooling and dehumidification and it could reduce a peak time owing to the use of air conditioners in summer. This study was performed to find out how much heating loads could be saved and furthermore whether this suggested system would be possible to do heating without a switch of system in real situations. Through model house experiments, the following conclusions were obtained. 1) The collector efficiency was 36% at maximum, but more improved structure of suggested collector could increase its efficiency. 2) The temperature of outlet air was about $30^{\circ}C$ and it could reduce heating loads. 3) Measured temperature and calculated one agreed well within ${\pm}1.5^{\circ}C$.

  • PDF

진공관형 태양열 집열기 히트파이프 작동유체에 따른 열성능 연구 (Experimental Study on Thermal Performance of Various Heat Pipe Working Fluid for Evacuated Tubular Solar Collector)

  • 주홍진;곽희열;김정배;김종보
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.70-75
    • /
    • 2007
  • This study was carried out to compare the thermal performance and operating characteristics of evacuated tubular solar collector(ETSC) with different working fluid. The evacuated tubular solar collectors with different working fluid of heat pipe were investigated in the same operating condition for a indoor experiment equipment. First, the result of working fluid with Water showed that $F_R({\tau}{\alpha})$ was 0.6636 and $F_{R}U_{L}$ was -1.8457. Second, Ethanol showed that $F_R({\tau}{\alpha})$ was 0.6147 and $F_{R}U_{L}$ was -0.6365. Third, Flutec-pp9 showed that $F_R({\tau}{\alpha})$ was 0.515 and $F_{R}U_{L}$ was -3.2313. Finally MA's showed that $F_R({\tau}{\alpha})$ was 0.6572 and $F_{R}U_{L}$ was -2.0086.

  • PDF

태양열급탕시스템의 집열기 배열에 따른 에너지성능 분석 및 평가 (Analysis on the Energy Performance of Solar Water Heating System according to the Configuration of Flat Plate Collectors)

  • 고명진;임보민;김용식
    • 한국태양에너지학회 논문집
    • /
    • 제36권4호
    • /
    • pp.49-56
    • /
    • 2016
  • The objective of this work is to analyze the variation in energy performance for each flat plate collector connected in series. In this study, it was assumed that solar water heating system with annual solar fraction of 60% was installed in an office building in Seoul, South Korea. The transient energy performance corresponding to four cases, which are selected using different solar radiation and outdoor air temperature, is studied by analyzing the variation in outlet temperature, solar useful heat gain, and thermal efficiency of each collector. It is observed that the useful heat gain and the collector efficiency decrease continuously, and outlet temperature increases when increasing the number of collector connected in series. The long-term performance is assessed by evaluating the thermal efficiency of each collector for two solar radiation conditions ranging from 780 to $820W/m^2$ and from 380 to $420W/m^2$. It is found that the differences between the intercept and slope of the efficiency curves for first and eighth collectors are 3.68% and 6.74% for solar radiation of $800{\pm}20W/m^2$ and 8.57% and 12.90% for solar radiation of $400{\pm}20W/m^2$, respectively. In addition, it is interesting to note that annual useful heat gain and collector efficiency are reduced with similar rate of about 6.13% when increasing the collector area by connecting the collectors in series.

PTC와 평판형 태양열집열기의 성능평가 비교 연구 (The Comparative Study on Performance of PTC and Flat-plate Solar Collector)

  • 김인환;허남수;김만석;이정언
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.28-33
    • /
    • 2010
  • Solar collectors to be applied are mainly flat-plate or vacuum tube collector which is used for hot water supply of house because of low heat value and low temperature. There are a necessity to expand applicable scope of solar collector into the industrial process heat source and air conditioner for coping with renewable energy policy of government and industrial trend. This study is to analysis the performance of PTC solar collector of concentrating type and flat-plate of non-concentrating. For this, temperature difference and heating value as insolation of air outside is measured from these two collectors mounted on 2-axial solar tracking system. It is investigated that temperature profile obtained from PTC solar collector is uniform and collecting heat per unit area is 6.8kcal/$m^2$ min which is about 3 times with compare to flat-plate collector of 2kcal/$m^2$min. Also the amount of heat to be produced from PTC solar collector is 3 Mcal/$m^2$ which is about 2 times with compare to flat-plate collector of 1.5Mcal/$m^2$ as a result of operating these two collectors during one month. Therefore, it is obtained that heat collecting performance of PTC solar collector is superior to flat-plate.

부하를 고려한 태양열온수시스템의 일간 집열효율에 대한 실험적 분석 (An Experimental Study on Daily Efficiency of Solar Collector with Heating Loads of Solar Water Heating System)

  • 이경호;주홍진;윤응상;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.19-27
    • /
    • 2012
  • This paper describes an experimental study on efficiency of solar collector in solar water heating system connected to hourly water heating load. In general, the functional form of solar efficiency is expressed as a function of fluid temperature entering solar collector, ambient temperature, and solar irradiance. When energy saving from solar heating of water heating system is analyzed on along-term basis such as one year with given solar irradiance data, simplified analysis is more convenient han detailed system simulation for quick assessment. However, the functional form of the efficiency is not convenient for approximately simplified energy analysis because the inlet temperature can be obtained through a detailed system simulation. In the study, solar collector efficiency is obtained with various daily water heating load sand daily solar irradiance using experimental tests. The study also considers large residential buildings such as apartment buildings for application of solar water heating systems. From test results, it is found that daily solar collector efficiency is proportional to daily water heating loads and daily solar irradiance. The data obtained from the study can be utilized to find a functional relation between daily solar irradiance and daily heating load in stead of collector inlet temperature for application of solar collector efficiency to long-term approximated energy analysis of solar heating system.

Rock-pile식(式) 집열기(集熱器)를 이용(利用)한 농산물건조(農産物乾燥)에 관(關)한 연구(硏究) (Drying of Agricultural Products by the Flat-plate Solar Collector with Rock-piled Heat Storage Medium)

  • 장규섭;김만수
    • Applied Biological Chemistry
    • /
    • 제26권2호
    • /
    • pp.75-81
    • /
    • 1983
  • 태양열(太陽熱) 축열장치(蓄熱裝置)의 개발(開發)을 위(爲)한 기초자료(基礎資料)를 얻기 위(爲)하여 태양열(太陽熱)의 축열매체(蓄熱媒體)로 돌을 이용(利用)한 평판집열기(平板集熱器)을 제작(製作)하여 집열기(集熱器)의 효율(效率), 총열전달계수(總熱傳達係數), 집열기(集熱器)에 의(依)한 상승온도등(上昇溫度等)을 분석(分析)하고 이를 열원(熱源)으로 벼와 고추에 대(對)한 건조실험(乾燥實驗)을 하였다. 초기함수율(初期含水率) 24.5%인 벼를 14.5%까지 건조(乾燥)시키는데 상온통풍건조(常溫通風乾燥)에서는 약(約) 18일(18日), 튜브형집열기(型集熱器)에서 약(約) 12일(12日), 평판집열기(平板集熱器)에서 약(約) 10일(10日)이 소요(所要)되었으며 통고추 건조(乾燥)의 경우 일광건조(日光乾燥)에서 약(約) 68시간(68時間), 튜브형집열기(型集熱器)에서 약(約) 38시간(38時間), 평판집열기(平板集熱器)에서 약(約) 36시간(36時間)이 소요(所要)되었다. 고추를 절단(切斷)하여 건조(乾燥)할 경우 수평(水平)으로 절단(切斷)하는 것이 효과적(效果的)이었으며 건조(乾燥) 과정중(過程中) capsanthine과 capsaicine성분(成分)의 변화(變化)는 건조방법(乾燥方法)이나 절단방법(切斷方法)에 따라 고추의 품질(品質)에 영향(影響)을 미치는 정도(程度)는 아니라고 사료(思料)되었다.

  • PDF

PV모듈의 냉각장치를 적용한 집속형 복합패널의 집열 특성 평가 (Thermal Characteristics Evaluation of Concentrated Hybrid Panel with cooling system on PV module)

  • 서유진;허창수
    • 한국태양에너지학회 논문집
    • /
    • 제25권3호
    • /
    • pp.47-52
    • /
    • 2005
  • Normally if sunlight is directed on a solar cell without any increasing in temperature, the amount of absorption energy per unit area of each cell is increasing. In a silicon solar cell. however, cell conversion efficiency decreases with the increase of temperature. Therefore, to maintain cell conversion efficiency under normal condition, it is necessary to keep the cell at operating temperature. We tried to design and make new hybrid panel with cooling system to prevent increasing of temperature on cell, collect and use thermal energy more effectively. We compared performance of this new hybrid panel with current thermal panel. We also evaluated conversion efficiency, thermal capacity and confirmed cooling effects from thermal absorption efficiency.

국내 저온용 집열기의 열성능 특성 (Thermal Characteristics of Domestic Solar Collector for Low-Temperature Applications)

  • 김정배;이순명;윤응상;이진국;주문창;백남춘
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.215-220
    • /
    • 2008
  • This study shows the results on thermal performance test with domestic solar collector for low-temperature applications using KS, then reveals the efficiency difference between KS and EN standard. Using the test results, this study presents the status of thermal performance with domestic solar collector including flat-plate, single evacuated, and double evacuated (with mirror or U-tube) solar collector.

  • PDF