• Title/Summary/Keyword: 집열관

Search Result 27, Processing Time 0.022 seconds

Analysis for Thermal Performance of Axially Grooved Heat Pipe for Solar Collector (그루브형 태양열 집열용 히트파이프의 열성능 해석)

  • Hong, J.K.;Suh, J.S.;Byon, G.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2123-2128
    • /
    • 2004
  • In this study, analysis is made for the effects of groove shape on the thermal performance of a axial groove heat pipe. The mathematical models of two-phase flow in grooved heat pipe are presented for the capillary limitation in steady state. Generally, the heat pipe performance depends on the capillary pressure and liquid flow. The friction force of liquid flow through the groove increases with the groove width decreased, and then the capillary pressure is improved in the gas-liquid interface of groove. Therefore, the optimal groove width shaper exists for the maximum thermal performance of heat pipe. In this paper, the optimal groove shape and scale are presented by considering both capillary pressure and liquid flow.

  • PDF

A Study on the Flat-Plate Solar Collector Performance taking into account of the Collector Thermal Capacitance (집열기(集熱器) 열용량(熱容量)을 고려(考慮)한 평판형집열기(平板型集熱器) 성능(性能)에 관(關)한 연구(硏究))

  • Lee, Young-Soo;Yong, Ho-Taek;Seoh, Jeong-Ill
    • Solar Energy
    • /
    • v.2 no.1
    • /
    • pp.17-23
    • /
    • 1982
  • This paper presents the performance of a Flat-Plate Solar Collector in case of taking into account of the thermal capacitance. The relationships among energy absorption, overall heat loss coefficient and temperature distribution are studied theoretically. And the thermal capacitance of the collector is considered. Also, the results obtained are compared with those of model in which the thermal capacitance is neglected. As the results of this study, the efficiency of the collector having double glazing is higher than the other cases. It is shown that the fluid temperature in the tubes are rising close to linearly. The variations of the outlet temperature of tubes in the model neglecting the effect of thermal capacitance are tend to represent lower slope than that of considering the effect of thermal capacitance.

  • PDF

Red Pepper (Capsicum annum) Drying Using Flat-Plate Solar Collectors (평판집열기(平板集熱機)를 이용(利用)한 고추 건조(乾燥)에 관(關)한 연구(硏究))

  • Kim, Dong-Man;Kim, Man-Soo;Chang, Kyu-Seob
    • Korean Journal of Agricultural Science
    • /
    • v.6 no.1
    • /
    • pp.56-64
    • /
    • 1979
  • Two types of fiat-plate collector were designed and constructed for utilizing the solar energy as heating source of red pepper drying. It was performed to investigate the basic factors on using the collectors and the drying effect on various types of red pepper, and the results obtained are summarized as follows. 1. The optimum tilted angles of the collector in Daejeon area were ${\phi}-15^{\circ}$ in summer season and ${\phi}+15^{\circ}$ in winter season when it was adjusted two times per a year: 2. In the conditions during experiment period, average atmospheric temperature and relative humidity were $25.6^{\circ}C$ and 52.6%, respectively, and $42.0^{\circ}C$, 74.2% in the control chamber. The temperature in the drying chamber connected to the water heater was the highest but relative humidity in the chamber connected to the air heater was the lowest among the chambers. 3. The drying velocity of whole red pepper in the chamber connected to the water heater was the fastest as 2.3 times as compared to the whole type on the mat drying followed by air heater and control in decreasing order. The horizontally cut red pepper in the chamber connected to the water heater was dried exceedingly fast among twelve plots. 4. The content of capsaicine as pungent principle and of capsanthine as red pigment in the red pepper were reduced during drying but there were no differences significantly on the drying method, and it could not affect much on the quality of dried product.

  • PDF

Analysis of the Heat Transport Capacity of a Axial Grooved Heat Pipe for Solar Collector (태양열 집열기용 히트파이프의 열전달 특성에 대한 해석)

  • Chung, Kyung-Taek;Bae, Chan-Hyo;Suh, Jeong-Se;Kim, Byeong-Gi
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.317-322
    • /
    • 2005
  • This study is aimed to analyze the effects of heat pipe shape on the heat transfer in solar collector with a axial grooved heat pipe. In the design of a heat pipe. two of the most important criteria to be met are the operating temperature range and the maximum heat transport capacity, When the operating temperature range is known and the working fluid has been selected, the maximum heat transport capacity depends strongly on capillary pressure and liquid flow. The heat transport capacity of the heat pipe will depend on the geometry of the heat pipe, the wick structure. the vapor channel shape. groove number. cooling temperature. condenser length and pipe diameter. So various shapes are used for mathematical models of two-phase flow in grooved heat pipe. From the results. the adequate groove shape and scale are presented by considering the heat transport and capillary limitation.

  • PDF

Design and Utilization of Solar Collector for Drying Agricultural Products (농산물(農産物) 건조(乾燥)를 위(爲)한 태양열(太陽熱) 집열기(集熱機)의 제작(製作) 및 이용(利用)에 관(關)한 연구(硏究))

  • Koh, Hak Kyun;Kum, Dong Hyeug
    • Journal of Biosystems Engineering
    • /
    • v.6 no.2
    • /
    • pp.48-57
    • /
    • 1982
  • In order to improve the quality of traditionally sun-dried red peppers and to increase the efficiency of drying performance, three types of solar dryers were designed and built, and drying performance of the solar dryers was compared to traditional sun drying. Results obtained from the experiment are summarized as fallows: 1. The air temperature and relative humidity profiles over a 8-hour period measured at the specified locations in the drying chamber of solar dryers appeared to have large variation in each dryer. The rate of drying increased with the temperature rise in the drying chamber of the solar dryer. 2. In general. drying with solar dryers proceeded faster than traditional sun drying. With A'-type of solar dryer developed in the second experiment it was possible to dry red peppers in seven days from an initial moisture content of 80% to safe storage conditions. The drying time with the A'-type solar drier was 50% shorter compared to traditional sun drying. 3. Red peppers appeared to have an increasing or constant-rate drying period until the weight of the product was reduced to about one half the initial weight, followed by a falling-rate drying period. When the dried red peppers were exposed to the atmospere during the night, the moisture content increased as much as 6%, which is much higher than for the grains. 4. It was suggested from the experiment that either a heat storage system or a supplemental heating system in the solar dryer was desirable for more efficient drying operation. 5. It was shown that the solar dryer developed in this study may be suitable for drying other vegetables and fishes, and also offered additional advantages of saving in drying time, maintaining sanitation and minimizing contamination by dust, insects and unfavorable weather condition.

  • PDF

Development of a Solar Collector Performance of Cylindrical Parabolic Concentrating Solar Collector (태양열(太陽熱) 집열기개발(集熱器開發)에 관(關)한 연구(硏究) - 포물반사곡면(抛物反射曲面)으로된 2차원(二次元) 집광식(集光式) 태양열(太陽熱) 집열기(集熱器)의 성능분석(性能分析) -)

  • Song, Hyun Kap;Yon, Kwang Seok;Cho, Sung Chan
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.54-68
    • /
    • 1985
  • It is desirable to collect the solar thermal energy at relatively high temperature in order to minimize the size of thermal storage system and to enlarge the scope of solar thermal energy utilization. So far the concentrating solar collector has been developed to collect solar thermal energy at relatively high temperature, but it has some difficulties in maintaining the volumetric body of solar collector for long term utilization. On the other hand, the flat-plate solar collector has been developed to collect the solar thermal energy at low temperature, and it has advantages in maintaining the system for long term utilization, since it's thickness is thin and not volumetric. In this study, to develop a solar collector that has both advantages of collecting solar thermal energy at high temperature and fixing conveniently the collector system for long term period, a cylindrical parabolic concentrating solar collector was designed, which has two rows of parabolic reflectors and thin thickness such as the flat-plate solar collector, maintaining the optical form of concentrating solar collector. The characteristics of the concentrating parabolic solar collector newly designed was analysed and the results are summarized as follows; 1. The temperature of the air enclosed in solar collector was all the same as $50^{\circ}C$ in both cases of the open and closed loop, and when the heat transfer fluid was not circulated in tubular absorber, the maximum surface temperature of the absorber was $118-120^{\circ}C$, this results suggested that the heat transfer fluid could be heated up to $118^{\circ}C$. 2. In case of longitudinal installation of the solar collector, the temperature difference of heat transfer fluid between inlet and outlet was $4^{\circ}-6^{\circ}C$ at the flow rate of $110-130{\ell}/hr$, and the collected solar energy per unit area of collector was $300-465W/m^2$. 3. The collected solar energy per unit area for 7 hours was 1960 Kcal/$m^2$ for the open loop and 220 Kcal/$m^2$ for the closed loop. Therefore it is necessary to combine the open and closed loop of solar collectors to improve the thermal efficiency of solar collector. 4. The thermal efficiency of the solar collector (C.P.C.S.C.) was proportional to the density of solar radiation, indicating the maximum thermal efficiency ${\eta}_{max}=58%$ with longitudinal installation and ${\eta}_{max}=45%$ with lateral installation. 5. The thermal efficiency of the solar collector (C.P.C.S.C.) was increased in accordance with the increase of flow rate of heat transfer fluid, presenting the flow rate of $110{\ell}/hr$ was the value of turning point of the increasing rate of the collector efficiency, therefore the flow rate of $110{\ell}/hr$ was considered as optimum value for the test of the solar collector (C.P.C.S.C.) performance when the heat transfer fluid is a liquid. 6. In both cases of longitudinal and lateral installation of the solar collector (C.P.C.S.C.), the thermal efficiency was decreased linearly with an increase in the value of the term ($T_m-T_a$)/Ic and the increasing rate of the thermal efficiency was not effected by the installation method of solar collector.

  • PDF

Development of Solar Warehouse for Drying and Storing the Agricultural Products (농산물(農産物) 건조(乾燥) 및 저장(貯藏)을 위(爲)한 태양열(太陽熱) 저장고(貯藏庫)의 개발(開發)에 관(關)한 연구(硏究))

  • Kim, Man Soo;Chang, Kyu Seob;Kim, Soung Rai;Jeon, Byeong Seon
    • Korean Journal of Agricultural Science
    • /
    • v.9 no.1
    • /
    • pp.357-370
    • /
    • 1982
  • Recent concern regarding price and availability of fossil fuels has spurred the interest in alternative sources for farm crop drying. Among the available options such as biomass energy, wind power, nuclear energy and solar energy etc., the increasing attention is being directed to the utilization of heat from solar energy especially for farm crop drying. Even though solar energy is dispersed over a large land area and only a relatively small amount of energy can be simply collected, the advantages of solar energy is that the energy is free, non-polluting. The study reported here was designed to help supply the informations for the development of simple and relatively inexpensive solar warehouse for farm crop drying and storage. Specifically, the objectives of this study were to determine the performance of the solar collector fabricated, to compare solar supplemented heat drying with natural air drying and to develop a simulation model of temperature in stored grain, which can be used to study the effects due to changes in ambient air temperature. For those above objectives, solar collector was fabricated from available materials. Corrugated steel galvanized sheet, painted flat black, was used as absorbers and clear 0.2mm polyethylene sheet was the cover material. The warehouse for rough rice drying and storage was constructed with concrete block, and the solar collector was used as the roof of warehouse instead of original roofing system of it. The results obtained in this study were as follows: 1. The thermal efficiency of the solar collector was average 26 percent and the overall heat transfer coefficient of the collector was approximately $25kJ/hr.m^2\;^{\circ}K$. 2. Solar heated air was sufficient to dry one cubic meter of rough rice from 23.5 to 15.0 percent in 7 days and natural air was able to dry the same amount of rough rice from 20.0 to 5 percent in l2 days. 3. Drying with solar heat reduced the required drying time to dry the same amount of rough rice into a half compared to natural air drying, but overdrying problems of the bottom layer were so severe that these problems should be thoroughly analyzed. 4. Simulation model of temperature in stored grain was developed and the results of predicted temperature agreed well with test results. 5. Based on those simulated temperature, changes in the grain-temperature were a large at the points of the wallside and the damage of the grain would be severe at the contact area of wall.

  • PDF