• Title/Summary/Keyword: 집속초음파

Search Result 99, Processing Time 0.022 seconds

Suppression of side lobe and grating lobe in ultrasound medical imaging system (의료용 초음파 영상 시스템에서 부엽과 격자엽의 억제)

  • Jeong, Mok Kun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.525-533
    • /
    • 2022
  • We propose an effective method for suppressing both side and grating lobes by applying 2-dimensional Fourier Transform to the received channel data during the receive focusing process of an ultrasound imaging system. When the signal from the image point is focused, the channel signals have the same DC value across the channels. However, even after echoes from outside an imaging point are focused, they are manifested as having different spatial frequencies depending on their incident angles. Therefore, after the receive focusing delay time is applied, 2-D Fourier Transform is performed on the time-channel data to separate the DC component and other frequency components in the spectral domain, and the weighting value is defined using the ratio of the two values. The side lobe and grating lobe were suppressed by multiplying the ultrasound image by a weighting value. Ultrasound images with a frequency of 5 MHz were simulated in a 64-channel linear array. The grating lobe appearing in the ultrasound image was completely removed by applying the proposed method. In addition, the side lobe was reduced and the lateral resolution was greatly increased. Results of computer simulation on a human organ mimicking image show that the proposed method can aid in better lesion diagnosis by increasing the image contrast.

Nonlinear phenomena in the focused fields diffracted by a straight edge (직선 edge 에 의해 회절된 집속음장내에서의 비선형 현상)

  • 김정순
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06d
    • /
    • pp.13-17
    • /
    • 1998
  • 집속음장이 고조파성분을 이용한 초음파영상의 특성을 해석하는 초기단계로서 음축에 수직하게 놓인 강체판의 직선 edge가 집속 가우스빔을 회절시킨다고 가정하고, edge의 전후에서 발생하는 제 2고조파를 고려해서 회절음장을 해석하였다. 계산에서는 그린함수의 간단화를 위해 , Fresnel 근사를 이용하였고 실험에서는 성형전극을 형성시킨 요면 압전진동자에 의한 1.9MHz 집속가우스음원에 의해 만들어지는 초음파 빔에 수직하게 edge을 삽입시켰다. 회절 edge 후방에서 음장을 관측한 결과, 제 2고조파의 빔형상을 제외하고는 계산치와 실험치가 잘 일치하고 있다.

  • PDF

Development of communcation signal interference removal module between High-Intensity Focused Ultrasound Devices using CAN communication (CAN 통신을 이용한 고강도 집속 초음파 디바이스간의 통신 신호 간섭 제거 모듈 개발)

  • Park, Jong-Cheol;Lee, Jin-Wook;Kim, Min-Sung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.463-465
    • /
    • 2022
  • The high-intensity focused ultrasound device intermittently operates abnormally due to communication signal interference between the devices during use due to the high frequency radiated during the skin treatment procedure. Communication interference between multi-frequency ultrasound devices can be reduced through CAN communication controller and transceiver design, firmware S/W program and CAN communication module development.

  • PDF

The Theoretical Investigation of Phased Array Guided Waves (위상배열 유도초음파 검사의 이론적 고찰)

  • Lee, Jae-Sun;Cho, Youn-Ho;Achenbach, Jan D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.4
    • /
    • pp.367-373
    • /
    • 2011
  • Guided waves inspection techniques that are different with inspection technique by bulk waves are widely used in pipe line evaluation due to advantages of long distance inspection. However, most of pipe lines at industrial fields are buried and/or coated. In this case, due to the attenuation effect from soil and/or coating material, there are a lot of difficulty on inspection by conventional ultrasonic technique. In this paper, guided waves propagating patterns are calculated with respect to excitation mode by Normal Mode Expansion(NME). Guided waves patterns based on excited by single transducer and guided wave focusing technique have employed to analyze focusing pattern on a pipe. A longitudinal mode and high order flexural modes are used with various number of transducers to determine sensitivity. Guided waves energy excited by multi transducer with focusing algorithm was successfully focused at a desired point.

A Study of Sidelobe Reduction Based on FFT in Ultrasound Images (FFT를 기반으로 한 초음파 영상의 Sidelobe 영향 감소에 관한 연구)

  • 정목근
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.40-47
    • /
    • 1999
  • Focusing is widely used to increase the resolution in ultrasound transmit field. It increases signal levels returning from the mainlobe direction and decreases those due to sidelobe directions. However, when the sidelobes cannot be completely canceled, the resulting image resolution is greatly deteriorated. This paper proposes a method of improving the resolution by scaling the received signal according to the difference between the mainlobe and sidelobe levels computed in the frequency domain by the use of Fourier transform. The proposed method is verified by computer simulation and experiments, and is shown to be highly effective in narrowing the mainlobe width and decreasing the sidelobe levels.

  • PDF

Signal Processing in Medical Ultrasound B-mode Imaging (의료용 초음파 B-모드 영상을 위한 신호처리)

  • Song, Tai-Kyong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.521-537
    • /
    • 2000
  • Ultrasonic imaging is the most widely used modality among modern imaging device for medical diagnosis and the system performance has been improved dramatically since early 90's due to the rapid advances in DSP performance and VLSI technology that made it possible to employ more sophisticated algorithms. This paper describes "main stream" digital signal processing functions along with the associated implementation considerations in modern medical ultrasound imaging systems. Topics covered include signal processing methods for resolution improvement, ultrasound imaging system architectures, roles and necessity of the applications of DSP and VLSI technology in the development of the medical ultrasound imaging systems, and array signal processing techniques for ultrasound focusing.

  • PDF

Recent clinical trials with ultrasound induced blood-brain barrier opening (초음파 기반 혈뇌장벽 개방에 관한 최신 임상시험 연구 현황)

  • Park, Juyoung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.564-569
    • /
    • 2022
  • Blood-Brain Barrier (BBB) is the brain protecting system blocking the inflow of harmful substances into brain parenchyma from brain blood vessel. However, the BBB has a negative effect on the treatment of various brain diseases such as Alzheimer's dementia or brain tumors because it also prevents drug delivery into brain parenchyma. To overcome this problem, a brain drug delivery technique using Focused Ultrasound (FUS) which allows BBB to be temporarily opened by inducing the acoustic cavitation effect of microbubbles has been developed. Thus far, various studies using the FUS technique has been conducted to improve drug delivery efficiency, and therefore, this paper discusses recently developed drug delivery technologies using the FUS-induced BBB opening.

Design and Construction of Hexgonal Ring-type Transducers for Ultrasonic Hyperthermia (초음파 hyperthermia용 육각환 변환기의 설계및 제작에 관한 연구)

  • Cho, Young-Hwan;Sung, Koeng-Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.5-12
    • /
    • 1989
  • In the clinical application of ultrasonic hyperthermia, selective heating of tumor is essential and thus precise control of ultrasonic intensity in both tumor and normal tissue is needed. In this paper, a hexagonal array transducer for ultrasonic hyperthermia is designed and manufactured of which focal point and focal region can be ocntrolled by the digital phase control circuit proposed by authors. Profiles of the focussed ultrasound beam in water and those of temperature in phantom were determined. The experimental and computed results are in good agreement.

  • PDF

Analysis of Ultrasound Synthetic Transmit Focusing Using Plane Waves (평면파를 이용한 초음파 합성 송신 집속 기법의 해석)

  • Lee, Jong Pil;Song, Jae Hee;Song, Tai-Kyong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.3
    • /
    • pp.200-209
    • /
    • 2014
  • In this paper, we present a general model for synthetic transmit focusing method using plane waves (STF-PW) of which the properties are investigated through mathematical analysis and compared with those of the conventional focusing method. The analysis results show that STF-PW produces non-diffracting beams in the sense that their main lobe widths do not change with depth. We also present a method for synthesis of plane waves to obtain a desired main lobe width while preventing grating lobe generation and a method for broadening the region over which the non-diffracting property is maintained. The proposed model and analysis results were validated through computer simulations.

Stress Evaluation by the Measurement of Acoustoelastic Effect Using a Line-Foucus Acoustic Microscope (선 집속 초음파 현미경을 이용한 음탄성효과 측정에 의한 응력 평가)

  • Kim, J.O.;Lee, Y.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.119-126
    • /
    • 1997
  • The relationship between the applied stresses and the change of elastic wave velocity has been established based on the acoustoelasticity theory. The non-uniform stress field in a loaded specimen has been evaluated from the surface acoustic wave velocity measured by the line-focus acoustic microscopy with the acoustoelastic constants obtained form a calibration test. The evaluated stresses are in good agreement with the results calculated by finite element method.

  • PDF