• Title/Summary/Keyword: 질량중위직경

Search Result 2, Processing Time 0.014 seconds

The Atomization Performance of Ceramic Nozzles in Air Carrier Sprayer (공기운반분무기용 세라믹 노즐의 미립화 성능)

  • 박석호;노수영
    • Journal of Biosystems Engineering
    • /
    • v.20 no.3
    • /
    • pp.236-244
    • /
    • 1995
  • Droplet size is one of the important factors in the deposition and drift of agrichemical application. In this study, droplet size and its distribution of the three different sizes of ceramic hollow cone nozzles being used in the air carrier sprayer for apple production were investigated at the various nozzle pressures and the three air velocities. The Malvern particle size analyzer were used for the measurement of droplet size and its distribution. The important results emerged from th is study can be summarized as follows. 1. Discharged rate was increase with the increase of the nozzle diameter and pressure, amount of the difference was remarkable between the nozzle diameter of 1.0, 1.2 and 1.5 mm, but no difference were found between the diameter of 1.0 and 1.2 mm in the same nozzle pressure. 2. Mass median diameter were varied as 40~160 ${mu}m$ at the air velocity of 0 m/s, 70~140 ${mu}m$ of 15 m/s and 100~160 ${mu}m$ of 20 m/s 3. It appeared that the air velocity range of 15~20 m/s was desirable for both drift and deposition control in the given experimental conditions.

  • PDF

Performance Characteristics of PM10 and PM2.5 Samplers with an Advanced Chamber System (챔버 기술 개발을 통한 PM10과 PM2.5 시료채취기의 수행 특성)

  • Kim, Do-Hyeon;Kim, Seon-Hong;Kim, Ji-Hoon;Cho, Seung-Yeon;Park, Ju-Myon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.8
    • /
    • pp.739-746
    • /
    • 2010
  • The purposes of this study are 1) to develop an advanced chamber system within ${\pm}10%$ of air velocity at the particulate matter (PM) collection area, 2) to research theoretical characteristics of PM10 and PM2.5 samplers, 3) to assess the performance characteristics of PM10 and PM2.5 samplers through chamber experiments. The total six one-hour experiments were conducted using the cornstarch with an mass median aerodynamic diameter (MMAD) of $20\;{\mu}m$ and an geometric standard deviation of 2.0 at the two different air velocity conditions of 0.67 m/s and 2.15 m/s in the chamber. The aerosol samplers used in the present study are one APM PM10 and one PM2.5 samplers accordance with the US federal reference methods and specially designed three mini-volume aerosol samplers (two for PM10 and one for PM2.5). The overall results indicate that PM10 and PM2.5 mini-volume samplers need correction factors of 0.25 and 0.39 respectively when APM PM samplers considered as reference samplers and there is significant difference between two mini-volume aerosol samplers when a two-way analysis of variance is tested using the measured PM10 mass concentrations. The PM10 and PM2.5 samplers with the cutpoints and slopes (PM10: $10{\pm}0.5\;{\mu}m$ and $1.5{\pm}0.1$, PM2.5: $2.5{\pm}0.2\;{\mu}m$ and $1.3{\pm}0.03$) theoretically collect the ranges of 86~114% and 64~152% considering the cornstarch characteristics used in this research. Furthermore, the calculated mass concentrations of PM samplers are higher than the ideal mass concentrations when the airborne MMADs for the cornstarch used are smaller than the cutpoints of PM samplers and the PM samplers collected less PM in another case. The chamber experiment also showed that PM10 and PM2.5 samplers had the bigger collection ranges of 37~158% and 55~149% than the theocratical calculated mass concentration ranges and the relatively similar mass concentration ranges were measured at the air velocity of 2.15 m/s comparing with the 0.67 m/s.