• Title/Summary/Keyword: 진폭스펙트럼

Search Result 162, Processing Time 0.023 seconds

Measurement of the Ultrasonic Longitudinal Wave Velocities in Thin Plate (얇은 판재에서의 초음파 종파속도 측정)

  • 안봉영;이승석;이재옥
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2181-2188
    • /
    • 1991
  • The ultrasonic longitudinal wave velocities propagating normal to the surface in thin plates were measured with the amplitude spectrum method. The accuracy of the velocity measurement in o.5mm thick plates was 0.1%. In 4.239mm thick plate the phase velocities at the frequency band of 5MHz-15MHz were measured with the phase spectrum method and the amplitude spectrum method, and the velocity difference between two methods was less than 20m/s.

The Acceleration Response Spectrum for Simulated Strong Motions Considering the Earthquake Characteristics of the Korean Peninsula (한반도 지진특성을 고려하여 모사된 강진동에 대한 가속도 응답스펙트럼)

  • Kim, Sung-Kyun
    • Journal of the Korean earth science society
    • /
    • v.28 no.2
    • /
    • pp.179-186
    • /
    • 2007
  • The response spectrum is one of the important basic materials for the aseismic design. Numerous strong ground motions based on the seismic source characteristics for the earthquakes occurring in the Korean Peninsula were simulated to obtain the response spectra by using the computer program, SMSIM, developed by Boore (2005). Through the extensive review of other study outcomes, the input data for the simulation such as seismic source and attenuation characteristics were selected. The spectra obtained from the simulated ground motions were normalized to 1.0 g of zero period acceleration and compared with the standard response spectrum proposed by the U.S. Atomic Energy Commission (AEC, 1973). In this study, we found that the spectral values for the response spectra appeared to be larger than those of the standard spectrum in the frequency band above roughly 10 Hz. The variation of resulting response spectra was evaluated with the variable stress drops. It was shown that the spectral amplitude of the spectrum for the larger stress drop denotes higher value in the low frequency range.

A Study on the Comparison and Evaluation of Spectrum Flattening Techniques (스펙트럼 평탄화 기법의 비교평가에 관한 연구)

  • 강은영;한상일;배명진
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.797-800
    • /
    • 2001
  • 스펙트럼의 평탄화는 스펙트럼 신호로부터 포만트의 영향이나 천이진폭의 영향을 제거하는 것이다. 따라서 정확한 피치검출과 포만트검출에 적용할 수 있다. 본 논문에서는 새로운 스펙트럼 평탄화 기법을 제안하고 기존의 방법인 LPC법, Cepstrum법과 비교하여 어느 정도의 우수성을 보이는지 평가하였다. 평가 방법은 각각의 평탄화된 신호의 분산을 구하여 평탄화의 정도를 측정하였다. 이때 핑탄화된 신호는 최고점이 영이 되도 록 정규화 시키고 평균이 영인 분산을 계산하였다. 실험 결과는 제안한 방법이 기존의 방법보다 우수함을 보여 준다.

  • PDF

Spectrum Filter Algorithm based on Acoustic Model (음향학적 모델에 의한 스펙트럼 필터 알고리즘)

  • Choi, Jae-seung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.770-772
    • /
    • 2016
  • 본 논문에서는 음성신호처리 시스템에 유용하게 사용되는 음성신호의 특징 파라미터를 출력하는 스펙트럼 필터모델을 사용하여, 배경잡음 환경 하에서 음성신호 중의 잡음을 제거하는 알고리즘을 제안한다. 따라서 본 논문에서는 배경잡음을 제거할 때 고려해야 할 인간의 청각특성이 포함된 음성의 진폭 스펙트럼에 의한 청각필터의 특성을 도입한다. 본 논문의 실험에서 사용한 성능평가의 방법으로는 음절 명료도의 테스트에 적합한 주관적인 평가인 주파수 영역에서의 스펙트럼 왜곡률(Spectral Distortion, SD)을 사용하여 실험결과를 비교하고 고찰한다.

  • PDF

Shock Waveform Synthesis for Shock Response Spectrum Test by Using Wavelets (충격반응 스펙트럼 시험에서 웨이브레트를 이용한 충격파형 합성)

  • 윤을재
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.25-25
    • /
    • 1998
  • 진동시험기를 사용한 충격시험은 자유 낙하식 충격시험기를 이용하는 것 보다 여러 가지 장점이 있으며, 충격반응 스펙트럼 시험의 요구가 점점 증가하고 있다. 진동시험기를 이용하여 충격반응 스펙트럼 시험을 실시하는데 진동시험기에서 허용하는 최대 힘, 속도, 변위에 의하여 제약을 받게 된다. 충격반응 스펙트럼을 만족하는 충격파형은 무수히 많으나 최대 가속도, 속도, 변위 등이 작으면 작을수록 그 충격파형의 품질이 우수하다고 말할 수 있다. 충격 지속시간이 짧고 충격가속도의 최대치가 큰 충격파형을 인가할 수 없지만, 충격 지속시간이 보다 길고 충격가속도의 최대치가 작은 파형이 동일한 충격반응 스펙트럼 규격을 만족할 수 있다. 진동시험기를 사용하여 충격반응 스펙트럼 시험을 수행하기 위한 충격파형이 웨이브레트를 이용하여 시험규격의 충격반응 스펙트럼을 만족하도록 합성된다. 웨이브레트의 매개변수는 주파수, 반파의 개수, 지연시간, 극성이다. 각 웨이브레트의 진폭은 시험규격의 충격반응 스펙트럼을 만족하도록·반복적으로 조절된다. 이렇게 합성된 충격파형은 진동시험기를 사용한 충격반응 스펙트럼 시험의 참조 가속도 파형으로 간주된다.

  • PDF

Computer simulation of Playback spectrum bumps due to pseudo gaps of MIG head (MIG 헤드 가상 갭에 의한 재생 전압 스펙트럼 Bump의 컴퓨터 시뮬레이션)

  • 한은실;조순철
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.2
    • /
    • pp.130-134
    • /
    • 1994
  • This paper describes the occurance of bumps in playback spectrum while reading with MIG heads. The amplitudes of the bumps in theoretically predicted frequencies are investigated by computer simulation. Three cases of MIG head structure are simulated, one without pseudo gaps, the other two with pseudo gap thicknesses of $0.02\;\mu\textrm{m}\;and\;0.2\;\mu\textrm{m}$ on both sides of the main gap, respectively. It is assumed that metal powder tapes are used. The results show that the bumps occur at predicted frequencies and the amplitudes of the bumps agree well with predicted values.

  • PDF

Acoustic characteristics of pacific white-sided dolphin sound observed in the middle coast of Donghae (동해중부연안에서 관측된 흰줄무늬 돌고래 발생음의 음향 특성)

  • 김봉채
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1996.06a
    • /
    • pp.51-54
    • /
    • 1996
  • 동해 중부 연안(수심: 200 m)에서 해수 중 주위잡음을 측정하는 동안 태평양 흰줄무늬 돌고래(pacific white-sided dolphin, 학명: Lagenorhynchus obliquidens)의 발생음을 수신하였으며 그 음향 특성을 분석하였다. 그 결과 얻어진 결론을 요약하면 다음과 같다. 첫째, 돌고래 발생음의 파형은 임펄스의 형태로서 그것의 전체 길이는 0.25~60.50 ms였고, 처음에 음(-)의 방향으로 작은 진폭을 보였으며, 그 후 작은 진폭으로 빠르게 감쇠진동하고 있는 형태를 나타내었다. 둘째, 돌고래 발생음의 주파수 스펙트럼은 약 18~90kHz의 광범위한 성분을 포함하고 있었다. 셋째, 돌고래 발생음의 스펙트럼 레벨 피크는 주파수 범위 35~55 kHz에서 나타났으며, 이것은 돌고래의 발생음이 없는 경우 해수 중 주위잡음의 레벨에 비하여 약 30~40 dB 높게 나타났다.

  • PDF

Ultrasonic Nondestructive Evaluation of Creep-Induced Cavities (크리프 기공의 초음파 비파괴평가에 관한 연구)

  • Jang, Young-Su;Jeong, Hyun-Jo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.2
    • /
    • pp.110-117
    • /
    • 1999
  • In order to ultrasonically evaluate creep cavities pure copper samples were subjected to creep test and their microstructures were examined. Ultrasonic velocities. frequency-dependent magnitude spectra and attenuations were measured on a series of copper samples obtained from the different stages of creep test. Velocities measured in three directions with respect to the loading axis decreased and their anisotropy increased as a function of the creep-induced porosity. The anisotropic behavior could be attributed to the progressive change of pore shape and preferred orientation as the creep advanced. The 2% porosity by volume decreased the longitudinal and shear wave velocities by 11% and 4%, respectively. Furthermore, both velocities decreased nonlinearly with the porosity. As the creep damage developed, the magnitude spectra lost high frequency components and their central frequencies shifted to lower values. The attenuation showed almost linear behavior in the frequency range used. Normalized velocity, central frequency shift and attenuation slope were selected as nondestructive evaluation parameters. These results were presented and showed good relations with the porosity content.

  • PDF

Seismic Trace Interpolation using Spectral Estimation (스펙트럼 추정을 이용한 탄성파 트레이스 내삽)

  • Ji Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.3
    • /
    • pp.134-137
    • /
    • 2003
  • A scheme for missing-trace interpolation of linear events is proposed. For a two-dimensional seismic dataset which contains linear events, a post-interpolation spectrum can be estimated from a portion of the original aliased spectrum. The restoration of missing trace data is accomplished by minimizing the energy after applying a filter which has an amplitude spectrum that is inverse to the estimated spectrum.