• Title/Summary/Keyword: 진동 추정

Search Result 674, Processing Time 0.025 seconds

Distribution of Natural Frequency of 2-DOF Approximate Model of Stay Cable to Reduction of Area (단면감소에 따른 사장케이블의 2-자유도 근사모델의 고유진동수 분포)

  • Joe, Yang-Hee;Lee, Hyun-Chol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.147-154
    • /
    • 2014
  • The cable damages of the bridge structures induce very important impact on the structural safety, which implies the close monitoring of the cable damage is required to secure sustained safety of the bridges. Most usual available maintenance techniques are based on the monitoring the change of the natural frequency of the structures by damages. However, existing method are based on vibration method to calculate lateral vibration and system identification can calculate the axial stiffness using sensitivity equation by trial error method. But the frequency study by the longitudinal movement need because of the sag effect in system identification. This study proposes a new method to investigate the damage magnitudes and status. The method improves the accuracies in the magnitudes and status of damages by adopting the natural frequency of longitudinal movement. The study results have been validated by comparing them with the approximate solution of FEM. Thus, the relationship of cable damage and frequency appear with relation that the severe damage has the little frequency. If we know the real frequency we can estimate the cable damage severity using this relationship. This method can be possible the efficient management of the cable damage.

Comparative Study of Cable Tension Measurement Methods by In-situ Measurements on a Cable-stayed Bridge under Construction (시공 중 사장교 실측을 통한 케이블 장력 추정 기법 비교 연구)

  • Cho, Soo-Jin;Yim, Jin-Suk;Shin, Sung-Woo;Jung, Hyung-Jo;Yun, Chung-Bang;Wang, Ming.L.
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.48-51
    • /
    • 2011
  • 사장교에서 케이블은 하중을 지지하는 주요 부재로, 케이블 장력은 사장교의 건전성과 안전도 평가에 있어서 매우 중요한 변수이다. 케이블 장력을 추정하기 위한 대표적인 방법으로는 로드셀을 이용한 직접법과 진동 계측 자료를 이용한 간접법 등이 있으며, 최근에는 자기장-응력 관계를 이용한 EM(Elasto-Magnetic) 센서 측정법이 개발되어 케이블 장력 추정에 적용되었다. 본 논문에서는 세 가지 장력 추정 기법을 실제 시공중인 사장교에 적용하여, 그 성능을 상호 비교하였다. 본 연구는 한국의 KAIST와 미국 Northeastern 대학교의 공동연구로 수행되었다. 대상 교량은 부산 화명동과 김해 초정리를 연결하기 위해 현재 건설중인 화명대교이다. 화명대교의 교량 형식은 2주탑 콘크리트 사장교 (주탑 경간장 270m, 총 사장교 구간장 500m)이며, 사장재로는 MS (Multi-Strand) 형 케이블이 사용되었다. 실험 당시 화명대교는 중앙경간의 폐합 후 선형관리를 위한 장력조정작업을 수행하였으며, 케이블 재긴장시의 정확한 장력관리를 위하여 로드셀을 이용한 Lift-off test방법으로 케이블의 장력을 측정하였다. 이와 동시에 두 개의 케이블을 대상으로 진동 가속도 센서와 EM 센서를 설치하고 장력 계측을 수행하였으며, 재긴장 단계별 장력 변화치를 지속적으로 계측하였다. 계측된 결과를 바탕으로 케이블 장력 추정 기법의 정확성 및 실교량에서의 활용성을 비교하였다.

  • PDF

다차원 스펙트럼해석의 기초와 응용

  • 오재응
    • Journal of the KSME
    • /
    • v.24 no.6
    • /
    • pp.446-451
    • /
    • 1984
  • 최근 기계구조물로부터 발생되는 소음. 진동의 수준을 평가하고 그 대책을 수립하는데 스펙트 럼분석(spectral analysis)과 상관기술(correlation technique)의 이용도가 점증하고 있다. 전자계 산기에 의한 데이터처리기술의 진보에 따라 불규칙한 입력을 받는 기계구조물의 고유진동수추정 및 진동모우드해석, 많은 소음. 진동원을 갖는 플랜트. 선박. 차량기기등의 발생원검출 및 기여 량파악, 그리고 acoustic emission 및 bispectrum에 의한 기기이상진단기술에 적용함으로써 공 학분야에서 한층 중요한 위치를 점하고 있다. 따라서 본 강좌에서는 먼저 상관해석에 의한 스 펙트럼의 정의에 대해서 기술하고 샘플링이론에 만족하는 시간간격으로 샘플링함으로써 얻어지는 시계열데이타를 Fourier 변환하여 주파수영역에서 계의 특성을 해석하는 원리 및 기여함수에 대해 설명하고자 한다. 그리고 입력원간에 상관이 존재하는 경우에 있어서 소음. 진동원을 검 출하고 기여량을 추정할 수 있는 방법으로서의 다차원스펙트럼해석법에 대해 간단하게 기술하 고자 한다.

  • PDF

Back Analysis Technique for the Estimation of Tension Force on Hanger Cables (역해석기법을 이용한 행어케이블의 장력 추정)

  • Kim, Nam-Sik;Park, Dong-Uk;Park, Yong-Myung;Cheung, Jin-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.1-10
    • /
    • 2007
  • In general, the tension forces of hanger cable in suspension bridges play an important role in evaluating the bridge conditions. The vibration method, as a conventional one, has been widely applied to estimate the tension forces by using the measured frequencies on hanger cables. However, the vibration method is not applicable to short hanger cables because the fiequencies of short cables are severely sensitive to flexural rigidity. Thus, in this study, the tension forces of short hanger cables, of which the length is shorter than 10 meters, were estimated through back analysis of the cable fiequencies measured from Gwang-An suspension bridge in Korea. Direct approach to back analysis is adopted using the univariate method among the direct search methods as an optimization technique. The univariate method is able to search the optimal tension forces without regard to the initial ones and has a rapid convergence rate. To verify the feasibility of back analysis, the results from back analysis and vibration method are compared with the design tension forces. From the comparison, it can be inferred that back analysis results are more reasonable agreement with the design tension forces of short hanger cable. Therefore, it is concluded that back analysis applied in this study is an appropriate tool for estimating tension forces of short hanger cables.

Study on the Efficient Application of Vision-Based Displacement Measurements for the Cable Tension Estimation of Cable-Stayed Bridges (사장교 케이블의 장력 추정을 위한 영상변위 측정법의 효율적 적용에 대한 연구)

  • Lee, Hyeong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.709-717
    • /
    • 2016
  • In this study, the convenience and efficiency of vision-based displacement measurement (VBDM) to estimate the cable tension of cable-stayed bridges and the requirements for its effective application were examined. To demonstrate its convenience and efficiency, it was confirmed that VBDM can be accomplished with a minimum amount of equipment using a commercial camcorder. In this case, it was found that the accuracy of estimation of the natural frequencies is sufficient, even though magnitude errors can occur when conducting high-speed recording at the low resolution afforded by the minimal equipment employed. It was also confirmed that the most important factor in detecting the precise natural frequencies is the use of the appropriate frequency range in the tension estimation using vibration. Based on these results, a study was carried out on the accuracy variation of the estimated tension according to the frame rate of a commercial camcorder. For this purpose, an experiment was performed to estimate the cable tension in a cable-stayed bridge model. Through this experiment, the detectable tensions of cables with various natural frequencies as a function of the frame rate were summarized. As a result, it was shown that the frame rate should be determined based on the natural frequency which is estimated to be located within the appropriate frequency range (approximately 10~75% of theoretical range) considering the aliasing and low-frequency distortion due to excitations.

A Case Study on Blasting Vibration 3D Modelling with Electronic-Delay System Detonator (전자발파시스템을 이용한 발파진동 3D 모델링 연구 사례)

  • Kim, Gab-Su;Yang, Ruilin;Kim, Yong-Gyun;Kang, Dae-Woo
    • Tunnel and Underground Space
    • /
    • v.24 no.2
    • /
    • pp.131-142
    • /
    • 2014
  • This study is using electronic-delay system detonator which can input an accurate detonating delay, compare predicted blasting vibration level derived from vibration 3D modelling with real measured blasting vibrations, and then considered modelling results are able to apply blast design. It confirmed there are certain relations between modelling and real vibration data, so modelling prediction method also can be apply design various blast conditions and prediction equation of blast vibration.

Structural Intensity Analysis of Stiffened Plate Using Assumed Mode Method (Assumed Mode Method를 이용한 보강판의 진동인텐시티 해석)

  • Dae-Seung Cho;Sa-Soo Kim;Sang-Min Jung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.35 no.4
    • /
    • pp.76-86
    • /
    • 1998
  • Structural intensity of plates experiencing bending vibration is analytically evaluated using the modal analysis based on assumed mode method. To evaluate the convergence of structural intensity according to the number of superposition modes, the power obtained by structural intensity integration over the closed curve containing the excitation source is compared with the power injected into plates. The erect of power reduction due to the material internal loss is evaluated using the intensity around a localized damping point, In addition, the dominant component among internal forces in the power transfer by the bending vibration of plates and the change of power flow due to stiffener are also investigated.

  • PDF

A Comparative Study on the Characteristics of Vibration Propagation during Open-Pit Blasting using Electric and Electronic Detonators (전기 및 전자뇌관을 이용한 노천발파 시 진동전파 특성에 관한 비교 연구)

  • Lee, Ki-Keun;Lee, Chun-Sik;Hwang, Nam-Sun;Lee, Dong-Hee
    • Explosives and Blasting
    • /
    • v.37 no.1
    • /
    • pp.24-33
    • /
    • 2019
  • Recently, Electronic Detonators have gradually increased their performance for various purposes such as vibration control and improved Fragmentation. This study analyzed the vibration estimation equations of electric and electronic detonator blast by comprehensive analysis of the vibration data collected during electric and electronic detonator blast waves at the comparison sites of urban areas, geology and soil conditions, stone quarries and mines in different areas of Korea from June 2017 to December 2018. It has been confirmed that electronic detonator blast can meet the criteria for allowing vibration even if maximum charge weight per delay is increased by 1.5 times compared to the electric detonator blast.

Modal Parameter Extraction of Seohae Cable-stayed Bridge : II. Natural Frequency and Damping Ratio (서해대교 사장교의 동특성 추출 : II. 고유진동수와 감쇠비)

  • Kim, Byeong Hwa;Park, Jong-Chil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.641-647
    • /
    • 2008
  • This paper introduces a new technique that can extract natural frequencies and damping ratios from output-only vibration data. Firstly, the free vibration data is obtained from the cross correlations of the output-only response data using a singular value decomposition process. Secondly, the well-known system identification algorithm is applied to extract the natural frequencies and damping ratios from the extracted free vibration data. Comparing to ERADC technique, the accuracy of the proposed modal parameter identification algorithm has been numerically examined. Furthermore, the practicability of the proposed algorithm has been examined through the output-only acceleration data collected from the Seohae cable-stayed bridge. Using the proposed technique, total 24 modes have been identified for the deck plate motions of the bridge.

Estimation of Structural Damages by Inverse Modal Perturbation Method (구조물 손상의 추정을 위한 Inverse Modal Perturbation 기법)

  • Min, Jin Ki;Kim, Hyeong Ki;Hong, Kyu Seon;Yun, Chung Bang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.4
    • /
    • pp.35-42
    • /
    • 1990
  • A method for the damage assessment of a structure by an inverse modal perturbation technique is studied. The first few natural frequencies and mode shapes of the damaged structure are assumed to be known. Then, the perturbation equation is formulated for the changes of the modal properties due to the stiffness changes. The stiffness changes due to damages are evaluated, using optimization techniques. Example analyses are carried out for several cases of stick models and a truss model. Results indicate that the present method yields very reasonable estimates for the element stiffness changes.

  • PDF