• Title/Summary/Keyword: 진동 저감효과

Search Result 261, Processing Time 0.024 seconds

Analytical Study on the Isolation Effects of Bore Holes by Materials (진동차단공의 재료별 방진효과에 관한 해석적 연구)

  • Lee, Kang-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.2
    • /
    • pp.23-30
    • /
    • 2006
  • This paper aims at investigating the material and dimensions of a wall barrier such as installation depth, thickness, and distance from vibration source by means of finite element method (FEM). In this study, various materials such as concrete, EPS, and steel were adopted. The results showed that the efficiency of a wall barrier appears to be more dependent on installation depth than thickness. In addition, a concrete wall barrier is less efficient than any other wall barrier. In contrast, EPS wall barriers seem to be much sensitive to the wall thickness than the depth.

  • PDF

Movable Anchorage System for Mitigation of Cable Vibration in Cable-Stayed Bridges with Sag (Sag가 고려된 사장교 케이블의 진동저감을 위한 Movable Anchorage 시스템)

  • Hwang, Inho;Park, Jun Hyung;Lee, Jong Seh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.657-664
    • /
    • 2008
  • Rain-wind induced cable vibration can cause the damages in the cable-stayed bridge due to very little inherent damping characteristics and low fundamental frequency. External Dampers attached to stay cables near anchorages have been shown to be effective means at short stay-cables. However, installation locations of external dampers are limited to a particular range due to aesthetic and practical reasons for very long stay-cables. A recent study by the authors showed that the stay-cable vibration system can perform better than the optimal passive viscous damper, thereby demonstrating its applicability in large cable-stayed bridges. This paper extends the previous study on the taut string representation of the cable by adding cable sag and inclination. The response of the proposed system compared to those of the cable with and without an external damper, and the movable anchorage system provides very effective mitigation of cable vibration. Cable damping ratio is seen to be remarkably reduced by movable anchorage system for a wide range of cable sag. This result shows that the sag effects of the proposed system should be considered.

Input Shaping for Vibration Reduction in Precise Positioning System (정밀 위치결정 시스템의 진동 저감을 위한 입력성형 기법)

  • Hong, Seong-Wook;Park, Sang-Won;Singhose, William E.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.4
    • /
    • pp.26-31
    • /
    • 2008
  • 본 논문은 정밀 위치결정 시스템의 잔류진동을 효과적으로 제거할 수 있는 입력성형기법을 소개하고, 실시간 입력성형기법을 적용하는 방법을 설명하였다. 또한 두 가지 응용 분야에 대한 실험결과를 바탕으로 입력성형기법의 성능을 고찰하였다. 일반적으로 입력성형기법은 정밀 위치결정 시스템에 대해 동작 완료시간을 단축시키는 효과가 있을 뿐만 아니라 위치결정 정밀도를 향상시키는 효과가 있다. 그리고 되먹임제어 방법에 비해 적용방법도 간단하며 저렴하게 구성할 수 있다는 장점이 있으므로 많은 정밀 위치결정 시스템에 유용할 것으로 생각된다.

A Study on the Characteristics of Noise & Vibration Propagtion in Sanbon Electric Railway Station (산본 전철 역사의 소음.진동 전파 특성에 관한 기초연구)

  • 김준호;김석홍;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.65-69
    • /
    • 1994
  • 전철의 궤도 방진에 의한 소음.진동 저감 효과를 실제 측정에 의해 확인하기 위해서는 궤도 방진 전과 후의 소음.진동 측정 데이타가 필요하다. 그러나 방진 궤도 구조로 설계된 신축 역사는 전철이 운행되지 않으므로 궤도 방진 전의 전철 운행시 발생하는 소음.진동을 측정할 수 없으며 공사완료 후 전철이 운행된다고 하여도 궤도 방진이 되지 않은 상태에서의 소음.진동 측정은 불가능하다. 따라서 본 연구에서는 현재 전철이 운행되고 있고 궤도 방진이 되어 있지 않은 유사한 구조의 산본 전철 역사를 선택하여 소음.진동을 측정, 분석하고 이 데이타를 방진 궤도 구조로 설계된 유사한 구조 신축 역사의 소음.진동을 예측하는데 기초 입력 데이타로 제시하고자 한다.

  • PDF

A Case Study of Combining NDC Blasting Method and Wide Space Blasting Method to Increase Blast Efficiency (NDC 및 Wide Space 혼합공법을 통한 발파효율 개선 사례연구)

  • No, Sang-Lim;Noh, Seung-Hwan;Lee, Sang-Pil;Lee, Hoon-Yeon;Lee, Tai-Ro
    • Tunnel and Underground Space
    • /
    • v.16 no.5 s.64
    • /
    • pp.387-393
    • /
    • 2006
  • This paper introduces the combination of two blasting methods applied to reduce blast-vibration and increase blast efficiency. NDC (New Deck Charge) blasting method using air deck effect with separation tube made of paper was effective to reduce blast-vibration, while blast efficiency was decreased a little in the bottom of a blasthole. Wide Space blasting method has an advantage to control the fragmentation and to increase blast efficiency over conventional blasting methods. In this study new blasting method combining NDC blasting method and Wide Space blasting method was applied to the field, it was confirmed to reduce blast-vibration and increase blast efficiency. It is expected to make useful blasting method to cover the public complaints and to shorten construction time by accumulating blasting data using new method with various conditions.

Experimental Study on Cement Cohesion Reduction Effect of Grout Mixer with Vibration Filter (진동필터가 설치된 그라우트 믹서의 시멘트 응집 저감 효과에 대한 실험적 연구)

  • Hwang, Sung-Pil;Jeoung, Jae-Hyeung;Kim, Chang-Yong;Lee, Woo-Je
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.61-67
    • /
    • 2018
  • Grouting is reinforcement or cutoff method which uses the hardening agent which is typically represented by portland cement and injected into the ground or the structure. When mixing the cement in powder form with water, the particles tend to cohere each other. Once they cohered, the particle size tends to become larger while injection efficiency becomes lower. This study, in a bid to reduce the cohesion of cement, the screen was set inside the grout mixer so that the cement particles are separated while vibrating them. To validate the effect of vibration screen, comparison test was conducted by using ordinary portland cement, slag cement and micro cement. Viscosity test, bleeding test and grain-size analysis indicated that the characteristics varied significantly after passing through the vibration filter. It is expected that the vibration filter installed inside the grout mixer will reduce the cement cohesion when mixing with water.

Numerical Simulation on the Behavior of Air Bubble Discharging into a Water Pool through a Sparger without Load Reduction Ring (하중저감 링이 없는 증기분사기를 통해 수조로 방출되는 기포 거동에 대한 수치해석)

  • 김환열;배윤영;송진호;김희동
    • Journal of Energy Engineering
    • /
    • v.12 no.4
    • /
    • pp.259-266
    • /
    • 2003
  • Load reduction ring (LRR) was installed on the ABB-Atom sparger to reduce the oscillatory loadings due to the air bubble clouds in the water pool in case of safety relief system operations. In order to investigate the effect of LRR on the pressure field, a numerical simulation on the behavior of air bubble clouds discharging into a water pool through a ABB-Atom sparser without LRR was performed by using a commercial thermal hydraulic analysis code, FLUENT 4.5. Among the multi-phase models contained in the code, the VOF (Volume Of Fluid) model was used to simulate the interface of water, air and steam flows. By comparing the analysis results with the previous ones, the load reduction ring has an effect on reducing the oscillatory loads at the wall. It also includes the effect of air mass and inlet boundary conditions of the pipe on the pressure oscillations at the wall.

Determination of Specimen Geometry for Identification of the Complex Modulus of Viscoelastic Materials (점탄성재료의 복소탄성계수 규명을 위한 시편 크기의 결정)

  • Kang, Kee-Ho;Sim, Song;Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.133-138
    • /
    • 1991
  • 일반적으로 고무를 비롯한 점탄성재료는 형상 및 크기를 적절히 조절함으로 써 한 방향 이상으로의 원하는 스프링상수를 얻을 수 있으며, 금속에 비하여 내부 마찰에 의한 에너지 발산이 매우 크기 때문에 강제 진동시의 진폭저감 및 충격에 따른 자유진동의 감쇠에 널리 이용되고 있다. 이와 같은 진동감쇠 에 점탄성재료를 효과적으로 사용하기 위해서는 복소탄성계수 즉, 탄성계수 와 손실계수를 정확하게 알아내는 것이 필요하다. 점탄성재료의 복소탄성계 수는 주파수, 온도 및 변형률등에 따라 변하므로 이와 같은 사용조건의 함수 로 구해야 한다. 복소탄성계수를 실험적으로 구하는 방법은 여러가지가 있으 며 실험의 용이성과 관심대상에 따라 적절한 방법을 선택하게 된다. 본 연구 에서는 주파수변화에 따른 복소탄성계수를 임피던스법으로 집중질량 모형을 이용하여 구하려고 할 때, 실험데이타로부터 보다 정확한 결과를 얻기 위하 여 적절한 시편의 크기를 결정하는 방법을 제시하고자 한다. 이를 위해서 시 편내의 파동전달효과와 포아송비와 관련된 양단제한효과 그리고 정하중시 압축변형에 대한 시편의 좌굴등을 고려하여 이론적으로 해석하였으며 실험 적으로도 검증하였다.

  • PDF

Natural frequency control of machine room of refrigerator (냉장고 기계실 평판의 고유진동수 제어)

  • Kim, Hae-Seung;Yang, Jung-Min;Hwang, Sang-Jae;Lee, Moon-Seek;Kim, Ue-Kan
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.224-224
    • /
    • 2011
  • 본 연구에서는 냉장고 압축기를 지지하고 있는 평판의 고유진동수를 제어하여 냉장고 전체에 전달되는 진동의 저감을 꾀하고자 한다. 평판의 과도한 진동의 원인을 분석하기 위해 먼저 실험 모드 해석을 수행하였다. 평판의 고유진동수를 효과적으로 제어하기 위해 평판의 고유진동수와 진동모드에 미치는 영향을 상용 구조 해석 프로그램인 ANSYS를 이용하여 검토하였다. 해석의 신뢰성은 먼저 수행한 실험 모드 해석 결과와의 비교를 통해 검증하였다. 이들 일련의 과정을 통해 냉장고 압축기를 지지하는 평판의 최적 형상 설계 방법 도출하였다.

  • PDF

Characteristics of Vibration and Sound Pressure Transmission by Controlled Spall Blasting Method (이완식 제어발파의 진동.음압전달특성에 관한 연구)

  • Kim, Sik;Jeong, Young-Jun;Kim, Nam-Soo;Cho, Yong-So
    • Explosives and Blasting
    • /
    • v.21 no.3
    • /
    • pp.17-22
    • /
    • 2003
  • 발파작업에서 발생하는 공해로 인한 재산상의 피해나 정신적인 피해를 최소화하기 위하여 대부분의 현장에서 제어발파를 시행하고 있다. 이완식 제어발파는 발파의 규모가 일반발파와 비교하여 작고, 대상 구조물이 근거리에 위치하므로 그 전달특성이 다를 수 있다. 근거리에서 계측된 발파진동의 특징은 고주파이고 진동의 지속시간이 짧다. 본 연구는 국내의 8개 지역에서 계측한 자료를 분석하여 이완식 제어발파의 진동전달 특성에 관하여 국내의 현장에서 시공 전에 진동을 추정할 수 있는 진동전파식을 제안하였다. 또한 제어발파시에 사용하는 폐타이어를 부착한 철재매트에 의한 폭풍압의 저감 효과와 전달특성을 분석하였다.