• Title/Summary/Keyword: 진동신호 에너지

Search Result 54, Processing Time 0.027 seconds

Efficiency Analysis of Schisandra Tea Using Image & Acoustic Signal Processing (영상과 음성 처리를 이용한 오미자차의 효능 분석)

  • Kim, Bong-Hyun;Cho, Dong-Uk;Han, Kil-Sung;J.Bae, Young-Lae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.2975-2981
    • /
    • 2011
  • We propose an efficiency analysis method to test whether Schisandra tea is beneficial to the health of internal organs, and, if so, to find which organ is mostly benefited. Firstly, for this, the color change in the right cheek region of face images before and after drinking Schisandra tea is analyzed using image processing techniques. Also, acoustic analysis experiments on both of the vocal cords vibration and the intensity value of acoustic signal are performed to investigate further Schisandra tea's effectiveness. The results of lung function smoothly by eating omijacha become. Vocal cords vibration and voice energy intensity of the right cheek region has changed a steady increase of the b values were observed.

Development of fault diagnostic system for mass unbalance and aerodynamic asymmetry of wind turbine system by using GH-Bladed (GH-Bladed를 이용한 풍력발전기의 질량 불평형 및 공력 비대칭 고장진단 시스템 개발)

  • Kim, Se-Yoon;Kim, Sung-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.1
    • /
    • pp.96-101
    • /
    • 2014
  • Wind power is the fastest growing renewable energy source in the world and it is expected to remain so for some times. Recently, there is a constant need for the reduction of Operational and Maintenance(O&M) costs of Wind Energy Conversion Systems(WECS). The most efficient way of reducing O&M cost would be to utilize CMS(Condition Monitoring System) of WECS. CMS allows for early detection of the deterioration of the wind generator's health, facilitating a proactive action, minimizing downtime, and finally maximizing productivity. There are two types of faults such as mass unbalance and aerodynamic asymmetry which are related to wind turbine's rotor faults. Generally, these faults tend to generate various vibrations. Therefore, in this work a simple fault detection algorithm based on spectrums of vibration signals and simple max-min decision logic is proposed. Furthermore, in order to verify its feasibility, several simulation studies are carried out by using GH-bladed software.

Development of Inverter fault diagnostic algorithm based on CT for small-sized wind turbine system (CT기반의 소형 풍력발전 시스템 인버터 고장진단 알고리즘 개발)

  • Moon, Dae-Sun;Kim, Sung-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.6
    • /
    • pp.767-774
    • /
    • 2011
  • In recent years, wind turbine system has been considered as the most efficient renewable energy source. Wind turbine system is a complex system which is composed of blade, generator and inverter systems. Recently, lots of researches on fault detection and diagnosis of wind turbine system have been done. Most of them are related with the fault diagnosis of mechanical elements using bivration signal. In this work, a new type of inverter fault detection and diagnstic algorithm is proposed. Furthermore, extensive simulation studies and practical experiments are carried out to verify the proposed algorithm.

Operating Characteristics of Low Vacuum Pumps (저진공 펌프의 운전 특성)

  • 임종연;심우건;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.2
    • /
    • pp.93-104
    • /
    • 2003
  • For evaluation of durability of low vacuum pumps, it is required to examine the performance and degradation of low vacuum pumps. Pump degradation may result from abnormalities associated with the performance in many areas of pump operation. The diagnostics method can be used to monitor the pump performance in the semi-conductor process line. Based on the mechanical defect of the pump, the dynamic response and reliability of the system for performance test, and the dynamic characteristics of the pump were experimentally assessed. The theoretical work rate for the compression process in the pump was calculated, and then the efficiency of the pump associated with the power consumption was evaluated. This analysis will be useful in detecting pump degradation with increasing the power consumption. To determine the predominant factors of pump degradation, it is important to evaluate the entire pumping system. We studied vibration, dynamic pressure, pumping speed, and power consumption of low vacuum pumps. Our results can be utilized for the future research on the evaluating technology of durability of low vacuum pumps.

Neutron Noise Analysis for PWR Core Motion Monitoring (중성자 잡음해석에 의한 PWR 노심 운동상태 감시)

  • Yun, Won-Young;Koh, Byung-Jun;Park, In-Yong;No, Hee-Cheon
    • Nuclear Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.253-264
    • /
    • 1988
  • Our experience of neutron noise analysis in French-type 900 MWe pressurized water reactor (PWR) is presented. Neutron noise analysis is based on the technique of interpreting the signal fluctuations of ex-core detectors caused by core reactivity changes and neutron attenuation due to lateral core motion. It also provides advantages over deterministic dynamic-testing techniques because existing plant instrumentation can be utilized and normal operation of the plant is not disturbed. The data of this paper were obtained in the ULJIN unit 1 reactor during the start-up test period and the statistical descriptors, useful for our purpose, are power spectral density (PSD), coherence function (CF), and phase difference between detectors. It is found that core support barrel (CSB) motions induced by coolant flow forces and pressure pulsations in a reactor vessel were indentified around 8 Hz of frequency.

  • PDF

Analysis of Vocal Cord Function by Humidity Change Based on Voice Signal Analysis (음성신호 분석 기반의 습도 변화에 따른 성대 기능 분석)

  • Kim, Bong-Hyun;Cho, Dong-Uk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.9
    • /
    • pp.792-798
    • /
    • 2012
  • Network Quotient, an important figure in modern society, the intelligibility of speech as a conversation partner to maximize pulling up feeling of liking it as much as possible has become an important issue. The humidity of air in the intelligibility of speech have many influences. Therefore, in this paper, we carried out experiment to apply voice signal analysis techniques which to analyze influenced vocal cords in 30%, 50% and 80%, maintaining a constant humidity of the environment. With this in mind, we carried out experiments on intensity and pitch of voice signal on twenty male 20s in maintaining a constant humidity 30%, 50% and 80% of humidity. Finally, we carried out study to draw a significance through statistical analysis measuring characteristic parameter of vocal cord function to change of humidity.

Pronunciation Influence Analysis of Carbonate Drink and Eucalyptus Fragrance by Applying Speech Signal Processing Techniques (음성신호 처리 기술을 적용한 탄산음료와 유칼립투스 발향이 발음에 미치는 영향 분석)

  • Kim, Bong-Hyun;Cho, Dong-Uk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.5C
    • /
    • pp.420-428
    • /
    • 2012
  • One of the most important means in modern NQ emphasized smart society is the communication skill. Especially, effects on improving pronunciation accuracy, it is mostly necessary to accurately express his or her own idea due to the personal relation influence 38% of voice. For this, this paper proposed the voice influence analysis of carbonate drink and eucalyptus fragrance. In particular, in the case of carbonate drink, the amounts of drinking accumulation is verified for analysing the drinking accumulation influence. Also, eucalyptus fragrance is reported for influencing the pronunciation accuracy. For this, jitter, shimmer, pitch and intensity of voice is analyzed. Finally, we accomplish an voice analysis of quantization, objective and visualization for such carbonate drink and eucalyptus fragrance.

High Energy Electron Dosimetry by Alanine/ESR Spectroscopy (Alanine/ESR Spectroscopy에 의한 고에너지 전자선의 선량측정)

  • Chu, Sung-Sil
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.85-92
    • /
    • 1989
  • Dosimerty based on electron spin resonance (ESR) analysis of radiation induced free radicals in amino acids is relevant to biological dosimetry applications. Alanine detectors are without walls and are tissue equivalent. Therefore, alanine ESR dosimetry looks promising for use in the therapy level. The dose range of the alanine/ESR dosimetry system can be extended down to 1 Gy. In water phantom the absorbed dose of electrons generated by a medical linear accelerator of different initial energies $(6\~21MeV)$ and therapeutic dose levels (1~60 Gy) was measured. Furthermore, depth dose measurements carried out with alanine dosimeters were compared with ionization chamber measurements. As the results, the measured absorbed doses for shallow depth of initial electron energies above 15 MeV were higher by$2\~5\%$ than those calculated by nominal energy $C_E$ factors. This seems to be caused by low energy scattered beams generated from the scattering foil and electron cones of beam projecting device in medical linear accelerator.

  • PDF

A Study on the Effect of Controllers in Small Signal Stability of Power Systems (전력계통의 미소신호안정도에 미치는 제어기의 영향에 관한 연구)

  • 권세혁;김덕영
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.72-79
    • /
    • 1996
  • The effect of controllers-Exciter, Power System Stabilizer, and Static Var Compensator-in one machine infinite bus system is investigated in this paper. The structure of generator state matrix with controllers is represented, while the Static Var Compensator is installed in generator terminal bus. Eigen-value analysis is performed and the effects of controllers to the dominant eigenvalue in one machine infinite bus system are represented by first order eigenvalue sensitivity coefficients while the operating conditions of the system are varied. Optimization of controller parameters using first order eigenvalue sensitivity coefficients is performed by the Simplex Method. It is proved that exciter control is the most efficient method to improve stability of the system and the effect of Static Var Compensator is small, in the case of one machine infinite bus system.

  • PDF

The Study of MAC protocol for efficient Wireless Sensor Network (Wireless 센서 네트워크를 위한 MAC 프로토콜에 관한 연구)

  • Lee, Woo-Chul;Kim, Dong-Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.517-520
    • /
    • 2005
  • Wireless sensor network combines sensing and computing technology which can sense light, temperature, vibration, magnetic field and wind etc, as each purpose of using those. Wireless nodes operate signal processing skill which has proceeded sensed information from the sensor, transmission which makes information reached to observer and limited energy managing skill which is needed on account of using battery to operate wireless. To make responsible measuring and sensing out of them, efficient energy management is so important to maintain life time of network. In this paper, after explaining CSMA/CA(Carrier Sense Multiple Access/Collision Avoidance) traditional wireless MAC protocol, and ER-MAC(Energy Rate Medium Access Control) which are not managing resource of hardware but MAN(Medium Access Control), data-link layer out of OSI 7 layer. We would like to analyze those efficiency of power saving comparing with each protocol.

  • PDF