• Title/Summary/Keyword: 진동성능평가

Search Result 758, Processing Time 0.027 seconds

Evaluation method of isolation performance for MIMO isolation table using singular value of transmissibility matrix (전달율 행렬의 특이치를 이용한 다입력/다출력 제진대계의 절연성능 평가법)

  • Sun, Jong-Oh;Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.324-329
    • /
    • 2012
  • Isolation tables are widely used for precision equipments and their isolation performances have been usually expressed and evaluated by transsmissibility. However, transmissibility is a concept for 1-degree of freedom(DOF) system. In practice, isolation tables are supproted by more than 4 springs. Each spring is subjected to vertical and horizontal ground vibrations, and also the table has more than 1-DOF. Therefore, isolation tables should be treated as multi-input/multi-output(MIMO) system of which isolation performance is expressed by transmissibility matrix. However, the matrix is too complicated to be an index for a system. In this paper, maximum singular value of transmissibility matrx is suggested as a simple performance index of a MIMO isolation system. Physical meaning of singular value is explained using a simple a 2-DOF isolation table. Furthermore, maximum singular values of passive, 3-DOF active and 6-DOF active isolation tables are obtained through experiments, and their meaning are explained and compared with each other.

  • PDF

Experimental Study on the Characteristics of Steel Hysteretic Dampers with E-Shape Elements (E-Shape 강재이력댐퍼의 거동 분석)

  • 김인배;강형택;이민구;서주원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.457-464
    • /
    • 2003
  • 최근 교량의 건설에 있어서 내진설계가 주요문제로 부각되면서, 구조물의 진동응답을 제어 하는 갖가지 형태의 진동제어 기법이 적용되고 있다. LRB(Lead Rebbe. Bearing), LUD(Lock Up Device)등 다양한 지진격리장치가 설계에 적용되고 있으며 특히, 설계변경 .내진보수보강과 같이 제약 조건이 있는 상황에서 유용한 면진방법으로 사용되고 있다. 이러한 지진격리장치는 기본적인 설계특성인 수평강성, 감쇠성능에 대한 검증을 필요로 한다. 특히, 지진과 같은 동적하중에 대하여 하중속도, 수직력, 변형률 등에 대한 의존성과 내구성의 검토가 필요하며 유사장치에 대하여 검증실험기준의 정립이 진행 중에 있다. 강재이력댐퍼인 E-Shape 댐퍼는 지진격리장치로서 교각의 고정단에 교좌장치로 설치되어 상시에는 탄성영역 내에서 거동하는 고정단의 역할을 하다가, 지진발생시에는 E-Shape형태의 강재댐퍼가 소성변형을 통한 이력거동으로 에너지 소산기능을 가진 교좌장치이다. 최근 LRB에 대하여는 다양한 특성실험이 수행되고 있으나 상대적으로 강재이력댐퍼에 대하여는 이러한 검증실험이 수반되지 않고 사용되고 있다. 본 실험연구에서는 E-Shape 강재이력댐퍼에 대하여 연직하중, 수평변형률, 수평속도에 패한 동적특성을 평가함으로서 강재이력댐퍼를 이용한 지진격리설계의 타당성과 면진성능을 평가해 보았다.

  • PDF

Seismic Performance Evaluation of Non-seismic T-bar type Steel-Panel Suspended Ceiling using Shaking Table Test (비내진 상세를 갖는 금속마감패널 천장시스템의 진동대 실험을 통한 내진성능평가)

  • Lee, Jae-Sub;In, Sung-Woo;Jung, Dam-I;Lee, Doo-Yong;Lee, Sang-Hyen;Cho, Bong-Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.171-180
    • /
    • 2019
  • In Korea, the seismic design of non-structural elements was interested by Earthquake of the 2016 Gyeong-ju and 2017 Po-hang. Among the non-structural elements, the ceiling system with steel panel used in Po-hang station showed failure examples of non-seismic design ceiling. In this study, the seismic performance of suspended ceiling with steel-panel, such as those used in Po-hang Station, was evaluated by shaking table tests. The shaking table tests were performed in accordance with the ICC-ES AC156 standard with floor acceleration being applied horizontally in one direction using a $3.3{\times}3.3m^2$ frame. The ceiling system consists of steel-panels, carrying channels, main and cross T-bars, and anti-falling clips. The anti-falling clip prevents the steel panel falling completely. The shaking table test confirmed that the damage at the previous stage had a direct impact on the damage state at the next stage. Through the shaking table test, the damage state of the T-bar type steel-panel suspended ceiling system was defined.

Similitude Law on Material Non-linearity for Seismic Performance Evaluation of RC Columns (RC기둥의 내진성능평가를 위한 재료비선형 상사법칙)

  • Lee, Do-Keun;Cho, Jae-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.409-417
    • /
    • 2010
  • This paper discusses a series of experiments including material improvement in order to ensure quality of grouting for the post-tensioned structure. In prestressed concrete, grouting refers to the construction procedure of filling empty space of duct enclosing with strands using cementitious material, To date, adequate quality control of the grouting has not been established in Korea because the relationship between the grouting and durability of post-tensioned structure is not well-recognized. The Korean standard does not consider the important material characteristic, wick effect, which is caused by strands in the ducts and current standard testing method unlikely quantify reasonable material segregation. As a result, the grout material, which meets the current material standards, may exhibit excessive bleeding water or shrinkage during construction. In this study, international codes and standards related to grouting were surveyed. The ratio of constituents and novel admixtures were suggested to meet equivalently with these standards. Performance of this enhanced grout was compared to common domestic grout using the international standard testing method. A series of mock-up specimens considering geometry of PC beam was constructed and grout flow pattern was observed as the grout was injected. It was observed that the grouting performance was highly influenced by material properties and filling characteristic can be varied depending on geometry of ducts.

A Study on Vibration Control Performance of Macpherson Type Semi-Active Suspension System (맥퍼슨 타입 반 능동 현가장치의 진동제어 성능 고찰)

  • Dutta, Saikat;Han, Chulhee;Lee, TaeHoon;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.2
    • /
    • pp.157-164
    • /
    • 2016
  • The paper studies a comparison analysis of semi-active control strategies for a Macpherson strut type suspension system consisting of MR(magneto-rheological) damper. As a first step, in order to formulate governing, a dynamic full model of a Macpherson strut is developed considering the kinematics. The nonlinear equation of motion of the strut is then linearized around the equilibrium point. A new adaptive moving sliding model controller is developed for fast response of the system. A newly proposed adaptive moving sliding mode control strategy is then compared with conventional sliding mode controller and skyhook controller. The comparison is made for two different types of road inputs; bump and random road profiles showing superior vibration control performance in time and frequency domains.

Performance Evaluation of RWA Vibration Isolator Using Notch Filter Control (노치 필터 제어기법을 이용한 반작용 휠 미소진동 절연장치의 절연성능 평가)

  • Park, Geeyong;Suh, Jong-Eun;Lee, Dae-Oen;Han, Jae-Hung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.391-397
    • /
    • 2016
  • Vibration disturbances induced by the reaction wheels can severely degrade the performance of high precision payloads on board satellites with high pointing stability requirements. The unwanted disturbances produced by the reaction wheels are composed of fundamental harmonic disturbances due to the flywheel imbalance and sub/higher harmonic disturbances due to bearing irregularities, motor imperfections and so on. Because the wheel speed is constantly changed during the operation of a reaction wheel, the vibration disturbance induced by the reaction wheels can magnify the satellite vibration when the rotating frequency of wheel meets the natural frequency of satellite structure. In order to provide an effective isolation of the reaction wheel disturbances, isolation performance of a hybrid vibration isolator is investigated. In this paper, hybrid vibration isolator that combines passive and active components is developed and its hybrid isolation performance using notch filter control is evaluated in single-axis. The hybrid isolation performance using notch filter control show additional performance improvement compared to the results using only passive components.

A Study of a Pilot Test for a Blasting Performance Evaluation Using a Dry Hole Charged with ANFO (건공화 공법의 발파 성능 평가를 위한 현장 시험에 관한 연구)

  • Lee, Seung Hun;Chong, Song-Hun;Choi, Hyung Bin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.2
    • /
    • pp.197-208
    • /
    • 2022
  • The existence of shallow bedrock and the desire to use underground space necessitate the use of blasting methods. The standard blasting method under water after drilling is associated with certain technical difficulties, including reduced detonation power, the use of a fixed charge per delay, and decoupling. However, there is no blasting method to replace the existing blasting method. In this paper, a dry hole charged with ANFO blasting is assessed while employing a dry hole pumping system to remove water from the drill borehole. Additional standard blasting is also utilized to compare the blasting performances of the two methods. The least-squares linear regression method is adopted to analyze the blasting vibration velocity quantitatively using the measured vibration velocity for each blasting method and the vibration velocity model as a function of the scaled distance. The results show that the dry hole charged with ANFO blasting will lead to greater damping of the blasting vibration, more energy dissipation to crush the surrounding rock, and closer distances for the allowable velocity of the blasting vibration. Also, standard blasting shows much longer influencing distances and a wider range of the blasting pattern. The pilot test confirms the blasting efficiency of dry hole charged with ANFO blasting.

A Study on Development of Standard Propellers for Coastal Fishing Vessels (연근해 어선용 표준형 추진기 개발)

  • Lee, Chang-Sub;Kang, Dae-Sun;Lee, Kun-Hwa;Kim, Moon-Chan;Moon, Il-Sung
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • s.31
    • /
    • pp.14-24
    • /
    • 2011
  • 최근 국제유가 상승과 탄소배출량 규제에 따른 친환경 선박의 개발 요구가 증대되고 있으며 이는 일반선 뿐만 아니라 어선에서도 마찬가지이다. 본 논문에서는 유류비 증가 및 어선의 노후화 등으로 인한 국내 어업 경쟁력의 약화 및 채산성 악화를 극복하기 위한 방안으로 연근해 어선용 추진기 개발을 위한 연구를 수행하였다. 현재 국내 어선현황에 기초하여 대표 선종인 130톤급 예망어선을 대상선으로 선정하고 추진기의 추진성능을 이론 및 실험적으로 평가 분석하였으며, 모형 시험 및 수치 해석 결과를 종합해 볼 때, 대상선의 프로펠러는 과도한 캐비테이션이 발생되는 상태에서 매운 높은 수준의 소음과 진동이 발생하는 것으로 추측된다. 이는 어선의 추진력 감소에 따른 연료비의 증대, 캐비테이션에 의한 추진기 손상, 과도하게 발생되는 소음에 따른 어획량 감소의 주된 원인이 된다. 본 연구를 통해 일반 상선의 추진성능 평가에 적용되는 최신 기술을 어선 추진기에 적용하여 모형시험 및 이론 성능 평가 과정을 정립하였으며, 이를 통해 앞으로 어선 추진기의 성능을 상당 부분 개선할 수 있음을 확인하였다.

  • PDF

Natural Frequency Analysis of Sleeper Floating Track System using Modal Test Technique (모달시험기법을 이용한 침목플로팅궤도의 고유진동수 분석)

  • Jung-Youl Choi
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.833-838
    • /
    • 2024
  • The urban railway sleeper floating track(STEDEF) is a structure that structurally separates the sleepers and the concrete bed using sleeper boots and resilience pads to reduce vibration transmitted to the concrete bed. Recently, the resilience pads of sleeper floating tracks that have been in use for more than 20 years are deteriorating. Accordingly, in order to evaluate the performance of the resilience pad, a static spring stiffness test is being performed after extracting the resilience pad. This evaluation technique is performed after replacing the resilience pad in use. However, the track natural frequency can change depending on the resilience pad spring stiffness and the uplift and subsidence of the concrete bed. In this study, modal testing technique was used to evaluate the track natural frequency. For this purpose, the sleeper boots material, resilience pad spring stiffness, and track natural frequency according to concrete bed uplift and subsidence were measured using modal tests at a laboratory scale. It was analyzed that the natural frequency of the sleeper floating track was directly affected by changes in the spring stiffness of the resilience pad. In addition, the change in natural frequency due to the uplift and subsidence of the concrete bed was also found to be large. Therefore, it is believed that the modal test technique presented in this study can be used to evaluate the resilience pad deterioration and voided sleepers.

Vehicle Test of Electromagnetic type Active Engine Mount (전자식 능동형 마운트 실차 성능평가)

  • Kim, Jeong-Hoon;Lee, Dong-Wook;Hong, Sung-Woo;Bae, Chul-Yong;Hong, Seung-Mo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.486-487
    • /
    • 2009
  • Recently active engine mounting system is developed for improvement of vehicle NVH Problem which is caused by development of high efficient powertrain and lightweight vehicle body. The aims in the development of active engine mounting system is performance confirmation of vehicle to apply active engine mount. In this paper, NVH test was done on test vehicle including active engine mount. And performance of active engine mount is evaluated by controlling active engine mount.

  • PDF