• Title/Summary/Keyword: 진동성능평가

Search Result 758, Processing Time 0.026 seconds

A Study on Flow and Vibration Analysis, and Performance Test for Automotive Fuel Pump (자동차 연료펌프의 유동 및 진동 해석과 성능시험에 관한 연구)

  • Son, Jae-Hwan;Bae, Jung-Sub;Kim, Young-Suk;Han, Chang-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1496-1502
    • /
    • 2012
  • The fuel pump mounted on the engine in the vehicle is consist of the outer and inter rotors, and which inhales fuel from the inlet port and supplies it to the outlet port. In this study, it is carried out the analysis and test of the fuel pump with rotors to evaluate its performance. It is analyzed the flow characteristics of the fuel pumps with numerical simulation in their inlet-outlet angles of 0, 15, 30 degree. After it is determined whether it has the best flow characteristics, its vibration characteristics is analyzed. The flow rate of a pump in the inlet-outlet angles of 0 degree is 191.0 LPH(Liter per hour) which is the largest. and its vibration is calculated to be 0.866 $^m/s^2$. In the results of vibration test, it is known that the vibration of the research pump is smaller than that of the existing one. And the natural frequencies of two pumps is nearly same. Therefore it is known that the performance of the research pump is superior.

Movable Anchorage System for Mitigation of Cable Vibration in Cable-Stayed Bridges with Sag (Sag가 고려된 사장교 케이블의 진동저감을 위한 Movable Anchorage 시스템)

  • Hwang, Inho;Park, Jun Hyung;Lee, Jong Seh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.657-664
    • /
    • 2008
  • Rain-wind induced cable vibration can cause the damages in the cable-stayed bridge due to very little inherent damping characteristics and low fundamental frequency. External Dampers attached to stay cables near anchorages have been shown to be effective means at short stay-cables. However, installation locations of external dampers are limited to a particular range due to aesthetic and practical reasons for very long stay-cables. A recent study by the authors showed that the stay-cable vibration system can perform better than the optimal passive viscous damper, thereby demonstrating its applicability in large cable-stayed bridges. This paper extends the previous study on the taut string representation of the cable by adding cable sag and inclination. The response of the proposed system compared to those of the cable with and without an external damper, and the movable anchorage system provides very effective mitigation of cable vibration. Cable damping ratio is seen to be remarkably reduced by movable anchorage system for a wide range of cable sag. This result shows that the sag effects of the proposed system should be considered.

Use of Semi-active Tuned Mass Dampers for Vibration Control under Various Excitations (다양한 하중의 진동제어를 위한 준능동 TMD의 이용)

  • Kim, Hyun-Su;Kim, Seung-Jun;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.1 s.47
    • /
    • pp.51-62
    • /
    • 2006
  • To dale, lots of types of tuned mass dampers are developed and investigated to reduce dynamic responses of a structure due to various causes. In this study, control performance of semi-active tuned mass damper(STMD), that can change the damping of tuned mass damper in real time based on structural responses, was investigated with respect to various types of excitation employing numerical simulation. Skyhook control algorithm was used to appropriately modulate the damping ratio of semi-active damper that composes STMD. The control effectiveness of a STMD under harmonic and random excitation were evaluated using a single-degree-of-freedom (SDOF) structure in comparison with a conventional passive tuned mass damper (TMD). The robustness of a STMD and a passive TMD were compared along with the variation of the mass of a SDOF structure. The control performance of STMD using magnetorheological (MR) damper was also investigated in this study. Based on the numerical studios, it was shown that the control effectiveness of the STMD was significantly superior to that of a passive TMD with respect to harmonic and random excitation.

Development of Piezoelectric Accelerometers and Their Performance Evaluation (압전형 가속도 센서의 개발과 특성평가에 관한 연구)

  • 이두희;임병덕;이용봉;김정태
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.4
    • /
    • pp.811-818
    • /
    • 1992
  • The sensor technology has becoming emerging area as the automation process in industry requires higher productivity, better quality, and the reliability. In this research, the dynamic measuring sensor such as piezoelectric accelerometers has been developed. Especially, the research concentrates on a design methodology, an analysis of the structural characteristics, and a method of the performance evaluation. The fabricated piezoelectric accelerometers show that the performance characteristics is better than commercial products available in the current market.

Speech Intelligibility Analysis on the Laser Detected Sound of the Glass Windows (유리창의 레이저 탐지음에 대한 음성명료도 분석)

  • Kim, Seock-Hyun;Lee, Hyun-Woo;Kim, Hee-Dong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.127-134
    • /
    • 2009
  • In this study, possibility of the laser eavesdropping is investigated on the window glasses with various thicknesses, Glass windows are excited by maximum length sequency (MLS) signal and the vibration sound is detected by a laser doppler vibrometer. From the detected sound, speech intelligibility is objectively estimated. Speech transmission index (STI), which is based on the modulation transfer function (MTF). is calculated for the estimation. Finally, disturbing wave effect on the speech intelligibility is analysed by using an outside speaker and a window shaker attached on the glass window. The purpose of the study is to estimate the possibility of remote eavesdropping by the laser sensor and to evaluate the performance of the homemade window shaker to protect from the remote eavesdropping.

Performance Evaluation Of Vibrating Table for Expendable Pattern Casting Process (소실모형주조용 진동장치의 성능평가)

  • Lee, Eun-Kung;Rim, Kyung-Hwa;Lee, Kyung-Whoan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.160-165
    • /
    • 2002
  • Vibration table is required to obtain high packing density in expendable pattern casting process. Packing density, which is an important manufacture factor, depends on the vibration pattern induced by vibration table. In general, circular vibration pattern is recognized as the best pattern. The existing vibration table is investigated to identify current vibration pattern and consider a countermeasure. Modal test is utilized to identify the dynamic characteristics of vibration table, and finite element method is used to present the improved design.

  • PDF

Evaluation of Torsional Vibration Isolation Performance Using In-situ Driveline Output Torque Measurement (구동 출력 토크 측정을 이용한 비틀림 진동 절연 성능 평가)

  • Kim, Gi-Woo;Jang, Jae-Duk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.382-387
    • /
    • 2012
  • This paper presents a proof-of-concept study on the evaluation of torsional vibration isolation performance through in-situ output torque measurement by using a non-contacting magneto-elastic torque transducer installed in the vehicle driveline system. The de-trending processing is first conducted to extract the torsional vibration from the measured driveline output torque. In order to estimate the transmissibility, primary performance indicator of a vibration isolator, the magnitude of transmitted torsional vibration with different frequencies is compared. From the conservative estimation results, the torsional damper built in a lock-up clutch of a torque converter is identified to be a vibration isolator. The evaluation results show that the fluid damping by torque converter outperforms the vibration isolation function of a torsional damper, and the isolation performance needs to be enhanced.

  • PDF

Correlation between Dynamic Characteristics of Isolation Material and Impact Noise Reduction of Light-weight Impact Source (충격음 저감재의 동특성과 실험실 경량충격음레벨 저감량의 상관관계)

  • 이주원;정갑철;권영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.191-195
    • /
    • 2003
  • 충격음 저감재의 동탄성계수와 감쇠계수는 차단성능을 평가하는데 있어 중요한 물성치가 된다. 저감재의 동탄성계수는 뜬바닥구조의 고유진동수를 결정짓게 되며, 저감재의 동탄성계수가 높을수록, 즉 고유진동수가 높아짐에 따라 실험실 경량충격음레벨 저감량은 지수함수적으로 감소됨을 실험을 통해 알 수 있다. 또한, 저감재를 포함한 뜬바닥구조를 1자유도 진동계로 가정한 이론값과 실험실 경량충격음레벨 저감량의 결과가 비교적 잘 일치하는 것으로 나타났으며, 이 때 감쇠계수의 영향은 반드시 고려되어야 한다.

  • PDF

Experimental Study of a Seismic Reinforcing System without Power Interruption and Movement for Electric Panel on the Access Floor (무정전-무이설 방식의 전기판넬 내진보강시스템 시험연구)

  • Jang, Jung-Bum;Lee, Jong-Rim;Hwang, Kyeong-Min;Ham, Kyung-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • The seismic reinforcing system is developed to prevent damage to electric panels which are installed on the access floor and are essential to the operation of various basic facilities such as electric power and communication etc., from earthquakes. The seismic capacity of seismic reinforcing system is verified through the shaking table test. The seismic reinforcing system is intended for the electric panel on the access floor, and installation is possible without movement and power interruption of the electric panel. The enveloped response spectrum is adopted considering the location of the electric panel in the building as input motion for the shaking table test. The shaking table tests are carried out with two electric panels that can be considered representative of general electric panels, and two types of access floors such as wood panel and steel panel, which are commonly used in the industrial field. As a result of tests, it is confirmed that the seismic reinforcing system secures the seismic safety of electric panels by preventing the overturning of electric panels during and after the shaking table tests. In the event that the seismic reinforcing system is applied to the electric panel on the access floor, damage to the electric panel from an earthquake can be effectively prevented, which can greatly contribute to the stable operation of domestic basic facilities.

Analysis and Isolation of Cultivator Vibration transmitted to Hand (손으로 전달된 관리기 진동의 분석과 방진 대책)

  • 박영준;채문권;김경욱
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.104-110
    • /
    • 2002
  • 본 연구는 보행형 관리기의 손으로 전달되는 진동특성을 실험적으로 해석하고 평가하며 방진 방안을 제시할 목적으로 수행되었다. 관리기의 작업기 중에서 설문을 통해 사용 빈도가 높은 3개의 작업기(중경로터리, 중경제초기, 구굴기)를 선정하였고 각 작업기별 진동수준을 측정하였다. 진동 방지 방안에 대해서는 4개의 방진 장치(고무 패드, 방진 장갑, 핸들 방진 장치, 엔진 마운트)를 선정하여 각 방진 장치별 진동수준을 측정하였다. 방진 장치의 성능을 정확하게 비교하기 위해 진동의 측정은 진동수준이 가장 높은 구굴기에서 수행되었다. 실험결과에 의하면 관리기 작업이 작업자의 인체에 해를 끼칠 위험이 매우 크지만 이 결과는 작업자가 매일 3시간씩 관리기를 사용할 경우를 기준으로 설정한 값이기 때문에 실제로 관리기 사용일수가 많지 알은 대부분의 우리나라 사용자들에게 적용하는데는 한계가 있음을 밝힌다. 그렇다 하더라도 관리기의 주 사용자는 보행형 관리기 뿐만 아니라 보행형 경운기나 보행형 이앙기 등의 손으로 전달되는 진동이 심한 기계를 함께 사용하는 경우가 많음을 고려하면 방진 장치를 개발하거나 진동수준이 낮은 농작업기계를 개발하여 작업환경을 개선하는 조치가 필요하다고 생각한다. 그러므로 농작업기계에 대한 진동수준에 대한 종합적인 연구와 그에 대한 대책 마련이 지속적으로 수행되어야 할 것이다.

  • PDF