• Title/Summary/Keyword: 진동내구성시험

Search Result 65, Processing Time 0.025 seconds

A study on the improvement method of heat treatment condition for the long-term stability evaluation in the floor impact isolator (층간소음저감재 장기 내구성 평가를 위한 가열시험의 문제점 및 개선방안에 관한 연구)

  • Park, Youn-Joon;Lee, Chan-Gyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.238-243
    • /
    • 2011
  • This study compared Kd, loss factor and thickness of floor impact isolator by loading/unloading heat treatment with results by continuous loading treatment and checked problem and improvement method of heat treatment condition for the long-term stability evaluation of the floor impact isolation. As the results, it is required the change of heat treatment condition unloading now to loading as actual weigh on the floor impact isolator.

  • PDF

Data Analysis of International Joint Road and Sea Transportation Tests Under Normal Conditions of Transport (국제공동 육해상 정상운반시험의 데이터 분석)

  • Lim, JaeHoon;Cho, Sang Soon;Choi, Woo-seok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.275-289
    • /
    • 2020
  • In 2017, multimodal transportation tests for evaluating road, sea, and rail transport were performed by research institutes in the US, Spain, and the Republic of Korea. In this study, acceleration and strain data determined through road and sea tests were analyzed. It was investigated whether the load generated for each transport mode was amplified or attenuated according to the load transfer path. From the results, it was confirmed that the load transfer characteristics differed according to the transportation mode and loading path. The effects of strain determined through each test on the structural integrity of the spent nuclear fuel were also investigated. It was found that the magnitude of the measured strain had a negligible effect on the structural integrity of the spent nuclear fuel, considering its fatigue strength. The results for the acceleration and strain data analyses obtained in this study will be useful for scheduled domestic transportation tests under normal transport conditions.

An Experimental Study on the Application of P.C.L-layer on the Railroad Bridge used to Latex Modified Concrete (Latex Modified Concrete를 이용한 철도교량의 PCL층 적용에 관한 실험적 연구)

  • Lee, Sun-Gyu;Choi, Sung-Min;Sung, Sang-Kyung;Park, Sung-Ki;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.757-760
    • /
    • 2008
  • The latex modified concrete was applied to baseplate of road bridge after 2000 year. This is in the limelight of stability to be missing problems. But, The baseplate of railroad bridge being experience to difficulty that searching method substituted for bridge waterproofing. In this study, I would like to application on P.C.L layer of railroad bridge using the property and merit of L.M.C. As a result performance test about six item, L.M.C was confirmed no problem to performance and application of bridge waterproofing.

  • PDF

Analysis of Vibration Characteristics for a Molded Dry-type Potential Transformer (몰드형 건식 계기용 변압기 진동 특성 분석)

  • Kim, Moosun;Jang, Dong Uk;Kim, Seung Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.209-214
    • /
    • 2017
  • Most of the present potential transformers of train vehicles are of the oil-type filled with insulating oil and are susceptible to problems such as explosion due to the increase in the internal pressure during train operation and poor reliability near the end of their life cycle. As a solution to this problem, it is necessary to develop a molded dry-type potential transformer with excellent pressure-resistance performance using insulating resin. In order to localize the product, the Korea Railroad Research Institute has been developing a molded dry-type potential transformer. As part of this research, it is necessary to analyze the vibration characteristics of the developed product and to check the transformer performance in a vibration environment. In this study, a resonance test and simulated long-term life test of the developed product were conducted according to the KS R 9144 and IEC 61373 standards, respectively, which are vibration test methods for railway vehicle parts. Their natural frequencies were analyzed by comparing the results of the numerical modal analysis and resonance test, in order to confirm their adherence to the standards. Also, the performance test after the simulated long-term life test confirmed that the operation of the developed transformer was not problematic even in a long-time vibration environment.

Vibration Analysis and Reduction for Large-scale Diesel Engines (대형 디젤엔진의 진동 분석과 저감)

  • Bae, Yong-Chae;Kim, Hee-Soo;Lee, Wook-Ryun;Lee, Doo-Young;Kim, Bong-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.1047-1052
    • /
    • 2011
  • Diesel engines are widely used as power supplies for isolated islands as well as emergency power supplies for large-capacity power plants because of their rapid response to operation, high reliability, and good durability. However, diesel engines are also vulnerable to damage or degradation of reliability when high levels of vibration are generated in them. This paper shows experiments and analysis for the determination of the causes of high-vibration phenomena in large-scale diesel engines, which have experienced various power decreases over several years because of the high levels of vibration. The main cause of the vibration is identified as the resonance created by the torsional vibration of its crank axis, and the appropriate countermeasures that were designed worked well when applied in field tests.

Flight Compatibility Certification of ALQ-X ECM Pod (ALQ-X ECM 포드 비행 적합성 인증)

  • Jun, Seung-Moon;Lim, Jae-Moon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.91-99
    • /
    • 2005
  • Flight compatibility certification is performed to substantiate the compatibility between ALQ-X ECM pod and KF-16D/RF-4C aircraft. A certification plan for the ALQ-X flight compatibility is established. Similarity analysis, mass/inertia analysis, structural analysis/test, and ground vibration test/flutter analysis are made to support the safety of MIL-HDBK-1763 Test 250 (Captive compatibility flight profile). Aircraft flew along flight envelope boundary with representative ALQ-X configurations. Handling qualities are evaluated by comparing flight characteristics of the aircraft with and without ALQ-X. Structural integrity and endurance is evaluated using measured flight test data. Results of these flight tests showed that ALQ-X is compatible with KF-16D/RF-4C without altering the flight envelope which has originally been certified for ALQ-88 and ALQ-119 ECM pods. ALQ-X certification program made following technical achievements: Type III certification for foreign designed fighter, flutter analysis program development using GVT results, and utilization of MIL-STD-1553B data bus in flight test.

Investigation on optimum applied potential for corrosion resistance and cavitation-erosion damage reduction of Al alloy in seawater (알루미늄 합금의 해수 내 내식성 및 캐비테이션-침식 손상 저감을 위한 적용전위 규명)

  • Jeong, Gwang-Hu;Park, Il-Cho;Lee, Jeong-Hyeong;Han, Min-Su;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.112-112
    • /
    • 2018
  • 알루미늄 합금은 내구성과 내식성이 우수한 경량 재료이다. 그 중 Al-Mg계 5083 Al 합금은 가공성 및 용접성이 우수하여 선체 재료로 널리 이용되고 있다. 이는 선체 중량의 경량화로 인해, 연료비 절감과 빠른 선속 등 다양한 이점을 지니기 때문이다. 그러나 선박의 고속화에 따라 선체에 가해지는 유체충격이 증가하고, 압력 저하에 기인하여 캐비테이션-침식 손상이 증가할 뿐만 아니라, 염소이온이 존재하는 해수환경에서는 침식과 부식의 시너지효과로 인하여 재료의 손상이 더욱 가속화된다. 이에 대한 다양한 방지책들이 제안되고 있으나, 강한 충격압을 동반한 캐비테이션 침식-부식 복합 손상 환경에서는 다소 한계가 있다. 따라서 본 연구에서는 알루미늄 5083에 대하여 캐비테이션 환경 하에서 일정 전위를 인가하며 침식-부식 손상이 최소화 되는 전위 구간을 규명하고자 하였다. 먼저, 분극 실험을 선행하여 재료의 전기화학적 거동을 파악 한 후 적용 전위구간을 선정하여, 해당 전위를 인가한 상태에서 캐비테이션 실험을 실시하였다. 전기화학적 분극실험과 캐비테이션-전기화학 복합 실험은 $25^{\circ}C$의 해수 하에서 실시하였으며, 시험편의 노출면적은 $3.24cm^2$으로 하였다. 분극 실험은 개로전위로부터 +3 V까지 2 mV/s의 분극속도로 전위를 인가하였고, 기준전극으로 Ag/AgCl, 대극으로 백금전극을 사용하였다. 캐비테이션-전기화학 복합 실험은 정전위를 인가한 상태에서 대향형 진동법으로 진동수 20 kHz, 진폭 $30{\mu}m$ 진동을 20분간 가하였으며, 혼팁과 시험편 사이의 거리는 1 mm로 일정하게 유지하였다. 실험 후 표면 손상의 정량적 분석을 위해 인가된 전위별 전류밀도를 비교하고, 무게감소량을 측정하였으며, 손상경향 파악을 위하여 3D광학현미경과 주사전자현미경(SEM)을 통해 표면을 분석하였다.

  • PDF

Study of Vibration Fatigue Test for Urea Tank of Diesel Vehicle Considering Vibration Characteristics (디젤차량 요소수탱크의 진동 특성을 고려한 진동내구시험법 연구)

  • Yoon, Ji Soo
    • Journal of Applied Reliability
    • /
    • v.18 no.3
    • /
    • pp.213-219
    • /
    • 2018
  • Purpose: Satisfying the environmental regulations, the automobile manufacturer should install urea tank, which is a key component of the urea system. However, due to the limitations of existing layouts, it may be mounted which is disadvantageous to vibration and shock resulting in durability robust. analyze the factors affecting the durability life of urea tank and the vibration characteristics through RLDA. In this study, clarify the limit of the current practice test method of urea tank and analyze the possibility of the new vibration test method in the system unit reflecting the characteristics of actual use condition. Methods: Analyzing the factors affecting the durability life of urea tank and the vibration characteristics through PSD & FDS of RLDA that actual vehicle driving data on durability test road. Results: The limit of the uniform width/single frequency test method of urea tank is clarifed and the positive prospects of the new test method are discovered. Conclusion: The vibration durability test with PSD method in system unit effectively reflects the magnitude and frequency characteristics of field vibration.

Performance Qualification Test of the CRDM for JRTR (요르단 연구용원자로 제어봉구동장치의 성능검증시험)

  • Choi, M.H.;Cho, Y.G.;Kim, J.H.;Lee, K.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.12
    • /
    • pp.807-814
    • /
    • 2015
  • A control rod drive mechanism(CRDM) is a reactor regulating system, which inserts, withdraws or maintains a control rod containing a neutron absorbing material within a reactor core to control the reactivity of the core. The top-mounted CRDM for Jordan Research and Training Reactor(JRTR) with 5 MW power has been designed and fabricated based on the HANARO's experience through KAERI and DAEWOO consortium project. This paper describes the performance qualification test results to demonstrate the operability of a prototype and four production CRDMs during the reactor lifetime. The driving performance, the drop performance and the endurance tests for CRDM are carried out at a test rig simulating the actual reactor conditions. A vibration of internal components due to the coolant flow is also measured using a laser vibrometer. As a result, the CRDMs are driven having a good driving performance without a malfunction between command and output signals for the stepping motor. Also, the pure drop time and the impact acceleration are within 0.72 s and 4.2 g to meet the design requirements, and the vibrational displacement of control rod is measured as maximum $5.2{\mu}m$.

Inverse Kinematic Analysis for a three-axis Hydraulic Fatigue Simulator Coupling (3축 유압 피로 시뮬레이터의 커플링에 대한 역기구학적 해석)

  • Kim, Jinwan
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.1
    • /
    • pp.16-20
    • /
    • 2020
  • The fatigue happening during the road riding of the vehicle and for the moment the aircraft lands on the runway is closely related to the life cycle of the landing gear, the airframe, the vehicle's suspension, etc. The multiple loads acting on the wheel are longitudinal, lateral, vertical, and braking forces. To study the dynamic characteristics and fatigue stiffness of the vehicle, the dynamic fatigue simulator generally has been used to represent the real road vibration in the lab. It can save time and cost. In hardware, the critical factor in the hydraulic fatigue simulator structure is to decouple each axis and to endure several load vibration. In this paper, the inverse kinematic analysis method derives the magnitude of movement of the hydraulic servo actuator by the coupling after rendering the maximum movement displacement in the axial direction at the center of the dummy wheel. The result of the analysis is that the coupling between the axes is weak to reproduce the real road vibrations precisely.