• Title/Summary/Keyword: 진동과 풍하중

Search Result 84, Processing Time 0.017 seconds

Experimental Study on the Vibration Control Capacity of Hybrid Buckling-Restrained Braces (하이브리드 비좌굴가새의 진동제어능력에 관한 실험적 연구)

  • Kim, Do Hyun;Ju, Young Kyu;Kim, Myung Han;Sung, Woo Gi;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.1
    • /
    • pp.83-91
    • /
    • 2009
  • Buckling Restrained Braces (BRBs) show good seismic behavior. They do not dissipate energy, however, when they are subjected to minor earthquakes or wind. Hybrid Buckling Restrained Braces (H-BRBs), which can improve the wind performance of the BRB system, are a kind of hybrid damper system composed of a viscoelastic damper and BRBs. In this paper, two H-BRB specimens with different cores were experimentally investigated to ensure the structural behavior of the H-BRB system in an elastic range. The axial deformation of the primary resisting system was compared with that of the secondary resisting system, and the equivalent damping ratio of the H-BRBs was estimated. It was concluded that H-BRBs with double shear dampers show good structural behavior and are applicable to tall buildings, to improve the building performance at a comfortable level.

Performance Evaluation of the Drift Control in Residential Tall Building Using the Dampers (제진장치를 적용한 초고층 주거형 건축물의 횡변위 제어 성능 평가)

  • Park, Ji-Hyeong;Kim, Tae-Ho;Kim, Ook-Jong;Lee, Do-Bum
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.265-273
    • /
    • 2008
  • The problem controlling lateral drift by the wind and the earthquake is very important in high rise buildings. But, outrigger system, generally used for residential tall buildings in Korea, has weak points with the occupancy of special space, the difficult construction and the long duration of works. On the other hand, the damper reduces story drifts of building structure by absorbing vibration energy induced by the dynamic loads and the application of damper systems is relatively simple. Also, the lateral drift control system such as outrigger system may raise the wind vibration problem of serviceability like human comfort and this problem may need another vibration control devices. Accordingly, we analyze the effect of the drift control using various dampers to substitute for outrigger system as the efficient system in residential tall buildings.

Seismic Response Analysis and Performance Evaluation of Wind-Designed Concentrically Braced Steel Highrise Buildings under Moderate Seismicity (중진대의 지진환경하에서 내풍설계된 초고층 철골조 중심가새골조의 지진응답해석 및 내진성능평가)

  • Lee, Cheol-Ho;Kim, Seon-Woong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.33-42
    • /
    • 2005
  • Even in moderate to low seismic regions like Korean peninsular where wind loading usually governs the structural design of a tall builidng, the probable structural impact of the 500-year design basis earthquake (DBE) or the 2400-year maximum credible earthquake (MCE) on the selected structural system should be considered at least in finalizing the design. In this study, seismic performance evaluation was conducted for concentrically braced steel highrise buildings that were only designed for wind by following the assumed domestic design practice. It was found that wind-designed concentrically braced steel highrise buildings possess significantly increased elastic seimsic capacity due to the system overstrength resulting from the wind-serviceability criterion and the width-to-thickness ratio limits on steel members. The strength demand-to-strength capacity study based on the response spectrum analysis revealed that, due to the system overstrength factors mentioned above, wind-designed concentrically braced steel highrise buildings having a slenderness ratio of larger than six can withstand elastically even the maximum credible earthquake at the performance level of immediate occupancy.

Structural Design And Analysis of Haeundae Doosan We've The Zenith (해운대 두산 위브 더 제니스 구조설계)

  • Park, Ki-Hong;Park, Suk-Jin
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.93-98
    • /
    • 2008
  • Haeundae Doosan We've The Zenith project is adjacent to Suyoung-bay, now it is in the process of excavation and foundation work. The main use of the tower is residence which height is 300m and 80 floor, the highest residential reinforced concrete building through the Orient. It is comprised of 3 high- rised buildings and 1 low-rised building, the basement is 230m wide and 200m length sized mass structure. The lateral resistance system is acted effectively against the lateral load and satisfactorily against the wind vibration by the 4 direction extension of the center core wall($700{\sim}800mm$ thickness) and reinforced concrete column set around the slab. Flat-plate slab system(250mm thickness) is adjusted for the slab system and it enables effective work process and shortening the working term by minimizing the ceiling height and not needing to install perimeter beam and drop panel. The strength and serviceability of the structure is able to be monitored and estimated constantly through the health monitoring system during the construction and after the construction.

  • PDF