• Title/Summary/Keyword: 진동과 풍하중

검색결과 84건 처리시간 0.228초

방음터널의 풍하중 산정 및 감음성능 예측 (Estimation of Wind Pressure on Soundproof Tunnel and Noise Reduction at Far-field)

  • 임정빈;김영찬;김두훈;조재영;이학은
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.542-547
    • /
    • 2004
  • The objective of this study is 0 estimate wind pressure acting on soundproof tunnel and noise reduction through the tunnel. For the purpose various shape of scale models were prepared and drag forces acting on each models were measured in wind tunnel. And numerical simulation was performed to confirm experimental results. As a result the lowest drag force coefficient of 0.59 was obtained in the case of arch roof shape model. Noise reduction through soundproof tunnel was simulated by using ray tracing method according to various open ratio of its roof area.

  • PDF

풍하중에 의한 건물내부 압력의 동적변화에 관한 연구 (Wind Tunnel Investigation of Fluctuating Pressure Inside Building)

  • 이경훈
    • 전산구조공학
    • /
    • 제3권4호
    • /
    • pp.133-141
    • /
    • 1990
  • 본 연구는 모형건물의 풍동실험을 통하여 건물내부에 작용하는 풍하중의 동적변화를 조사연구하였다. 실험에 사용된 모형건물은 건물외부에 작용하는 풍하중이 건물내부에 전달될 수 있는 개구부가 설치된 직육면체 형태의 구조물인데 실험시 개구부의 면적과 방향을 변화하고 정상류와 난류 상태의 풍하중을 사용하였다. 주어진 실험 조건하에서 건물내부 압력의 진동주파수를 알 수 있는 power spectrum과 내부압력의 동적변화량을 알 수 있는 RMS를 측정하여 분석하였는데 분석된 실험결과는 비교적 최근에 제안된 이론과 일치하였다.

  • PDF

바람과 파랑을 받는 해상 풍력 기상탑의 동적 응답 (Dynamic Responses of Offshore Meteorological Tower Under Wind and Wave)

  • 권순덕
    • 한국풍공학회지
    • /
    • 제22권4호
    • /
    • pp.171-177
    • /
    • 2018
  • 본 연구에서는 해상 풍력용 기상탑의 파단 원인을 찾기 위하여 실측된 풍속 자료를 분석하고, 변동 풍하중과 파랑하중에 의한 동적 변위를 산정하였으며, 와류진동에 대한 피로 검토를 수행하였다. 그 결과를 보면, 베인 풍속계와 초음파 풍속계의 10분 최대 풍속을 비교하여 기상탑에서 4시간 지속된 진동이 발생했음을 확인하였다. 그리고 파랑하중보다 풍하중이 기상탑의 동적 응답에 미치는 영향이 훨씬 크지만, 두 하중이 동시에 작용해도 기상탑의 부재력이 설계력보다 훨씬 낮아서 직접적인 파단의 원인이 아닌 것으로 나타났다. 하지만 와류진동은 연결부 볼트에서 피로 파괴를 일으키는 것으로 나타나서, 기상탑의 파단 원인은 유체의 변동 성분이 아닌 와류진동인 것으로 판단된다.

지하철 고가교 접합강화유리 방음판의 열차진동 및 풍하중에 대한 성능평가 (Performance Evaluation of Laminated-Tempered Glass as a Component of Noise Barrier on Metro Railway Elevated Bridge Against Train Induced Vibration and Wind Load)

  • 김석수;이호범;송재호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권5호
    • /
    • pp.30-41
    • /
    • 2017
  • 소음 저감을 목적으로 설치되는 방음벽은 크게 흡음판과 방음판으로 나뉘며, 일조 및 경관을 저해하는 방음벽의 문제점을 해결하고자 투명 방음벽을 설치하는 것이 일반적 추세이다. 방음벽에 사용되는 투명 방음판의 소재는 여러 가지가 있으나 경우에 따라서는 황변현상과 재질변형 등으로 인해 투명도가 떨어지고 오염이 심해져 오히려 도시미관을 해하기도 한다. 따라서 이러한 단점을 보안하기 위하여 투명 방음판의 재질을 접합강화유리로의 대체가 가능하다. 본 논문은 메트로 지하철 고가교 상에서의 열차 유발진동에 따른 접합강화유리 방음판의 진동 및 풍하중에 의한 안전성을 분석하고, 접합강화유리 시스템 및 재료에 대한 휨능력 성능시험, 압축강도 및 탄성계수 시험, 충격시험 등을 수행하여 접합강화유리의 방음판으로서의 적정성을 평가하는 데 목적이 있다.

점탄성감쇠기를 이용한 송전철탑 풍하중의 저감 (Wind Load Mitigation for Transmission Tower using Viscoelastic Damper)

  • 민경원;박지훈;문병욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.955-958
    • /
    • 2005
  • In this study, the wind load characteristics for a transmission tower is investigated considering the effect of the transmission lines through stochastic analysis. The assemblage of the transmission line and insulator are modeled as a double pendulum system connected to the SDOF model of the tower It is observed that the background component of the overturing moment induced by the wind response of the transmission line has considerable portion in the total overturning moment. Based on this result, a rotational viscoelastic damper (VED) is proposed for the mitigation of the transmission line reactions, which act as wind load transferred to the tower. To verify the effectiveness of the proposed strategy, time history analysis is conducted for different wind velocities and VED damping constants. From the analysis, the proposed VED is proved to be effective for mitigation of the background component rather than the resonance component of the transmission line reaction.

  • PDF

전단벽 구조물의 풍응답 저감을 위한 LRB의 적용 (Application of LRBs for Reduction of Wind-Induced Responses of Coupled Shear Wall Structures)

  • 박용구;김현수;고현;김민균;이동근
    • 한국공간구조학회논문집
    • /
    • 제11권1호
    • /
    • pp.47-56
    • /
    • 2011
  • 일반적으로 전단벽은 횡력저항 요소로서 널리 이용되고 있다. 대부분의 전단벽 구조물은 통로의 목적으로 개구부를 필요로 하게 되고 전단벽들 사이가 슬래브나 연결보로 연결된 병렬전단벽의 형태를 띠게 된다. 본 연구에서는 병렬전단벽 구조물의 연결보 중앙부에 LRB(Lead Rubber Bearing)를 도입하였고 이 시스템의 풍응답 저감성능을 검토하였다. 제안된 방법의 효과를 살펴보기 위하여 20층 및 30층 예제구조물을 구성하였고 인공풍하중을 작성하여 경계비선형 시간이력해석을 수행하였다. 제안된 방법이 풍하중을 받는 고층 병렬전단벽 구조물의 사용성 향상에 도움을 줄 수 있는지 평가하기 위하여 일본 진동성능평가기준을 적용하여 보았다. 해석결과 본 논문에서 제안하는 LRB를 사용하여 병렬전단벽을 연결하는 방식이 풍응답 제어성능 개선에 효과가 있는 것을 확인할 수 있었다.

개폐식 대공간 구조물의 파라메트릭 설계와 풍하중 적용 (Parametric Design and Wind Load Application for Retractable Large Spatial Structures)

  • 김시욱;정보라;김치경;이시은
    • 한국전산구조공학회논문집
    • /
    • 제32권6호
    • /
    • pp.341-348
    • /
    • 2019
  • 본 연구의 목적은 개폐식 대공간 구조물의 풍하중 산정 및 구조해석의 과정을 자동으로 수행하는 컴포넌트를 개발하는 것이다. 설계한 파라메트릭 모델링을 StrAuto를 통해 구조해석 자동화단계를 거쳐 구조해석용 모델로 변환하는 과정을 실시간으로 연동하여 구조해석 결과를 자동으로 도출하는 과정으로부터 본 연구에서는 추가로 구조물의 풍하중을 형상에 따라 상세히 할당하는 기능을 개발하였다. 이와 같은 과정을 통해 풍하중에 대한 최적화를 수행하여, 기존 설계된 구조의 물량을 줄이고, 구조적 안정성은 유지하는 방향으로 결론을 도출하였다. 추후에는 본 예제 모델을 통해 진동제어 최적화를 위한 제진장치 설치위치의 자동탐색이 가능하게 되는 연구를 진행할 계획이다.

마찰댐퍼에 의한 사장 케이블의 진동저감 효과 (Vibration Reduction Effects of Stay Cable Due to Friction Damper)

  • 김형구;임성순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권2호
    • /
    • pp.54-61
    • /
    • 2013
  • 사장교 케이블은 초기 큰 인장력으로 축강성이 매우 크지만, 횡방향 휨강성은 약하다. 풍하중이나 교통하중은 케이블을 심각하게 진동시켜 사장교의 사용성에 부정적 영향을 끼친다. 그러므로 장대교량에 감쇠장치를 설치하는 진동 저감 계획이 절실히 요구된다. 마찰댐퍼는 교통하중이나 풍하중과 같은 동적하중이 작용하는 케이블 진동에서 진폭과 지속시간을 대폭 감소시킬 수 있는 효과적인 장치임을 알 수 있다. 케이블 진동은 댐퍼제작방법과 설치위치 및 형상에 따라 효율이 달라질 수 있다. 그럼에도 불구하고 본 실험연구의 마찰댐퍼 설치전 후 제진성능효과 분석결과는 향후 사장케이블의 진동을 저감시키는 기본 자료로 활용할 수 있다.