• Title/Summary/Keyword: 진동,소음

Search Result 12,520, Processing Time 0.041 seconds

Development of Position Sensor Detection Circuit using Hall Effect Sensor (Hall Effect Sensor를 이용한 위치센서 검출회로개발)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.2
    • /
    • pp.143-149
    • /
    • 2021
  • BLDC motors are getting better performance due to the improvement of material technology including high performance of permanent magnets, advancement of driving IC technology with high integration and high functionality, and improvement of assembly technology such as high point ratio. While having the advantage of such a square wave driven BLDC motor, interest in the design and development of a square wave driven BLDC permanent magnet motor and development of a position detection circuit and driver is increasing in order to more meet the needs of users. However, in spite of the cost and functional advantages due to reduced efficiency, switching loss and vibration, noise, etc., the application is somewhat limited. Therefore, in this paper, we study a position detection circuit that generates a sinusoidal signal in proportion to the magnetic flux of a BLDC motor rotor using a Hall Effect Sensor that generates a sinusoidal wave to increase the efficiency of the motor, reduce ripple, and drive a sinusoidal current with excellent speed and torque characteristics.

Analysis of vortex generation tendency around the pump suction using three dimentional numerical model (3차원 수치모형을 이용한 펌프 흡입부 주변의 와류 발생 경향 분석)

  • Byun, Hyun Hyuk;Yang, Jae Hoon;Yoon, Byung Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.103-103
    • /
    • 2016
  • 최근 기후변화에 따른 집중호우로 도시홍수의 피해가 급격히 증가하고 있다. 특히 인구가 밀집하고 교통량이 많은 대도시의 경우 동일한 호우에 대하여 녹지나 농경지 등에 비해 그 피해가 더 심각하다. 일반적으로 홍수 피해의 직접원인은 외수로 인한 피해와 내수로 인한 피해로 크게 구분할 수 있다. 외수피해는 주로 소하천 및 지천의 범람, 제방의 붕괴 등으로 발생한 것이며 내수피해는 배수로, 하수도 및 펌프장의 내수배제능력 부족이 주된 원인이다. 따라서 도시홍수를 효과적으로 방어하기 위해서는 우선적으로 내배수시설의 성능개선이 선행되어야 할 필요가 있다. 이러한 내배수 시설의 성능 개선을 위해서는 현재 기 설치되어 있는 빗물펌프장의 설계 및 내배수 효율에 대한 성능평가가 필요하다. 하지만 현재 국내 펌프설계기준에는 빗물펌프장의 설계 및 운영에 대한 구체적인 성능 평가 방법이 제시되어 있지 않은 실정이다. 만약, 펌프 흡입수조 및 흡입파이프의 형상이 적절하게 설계되지 못한다면 물이 파이프 입구로 부드럽게 흡입되지 못하고 볼텍스 및 스월이 발생하게 된다. 이러한 볼텍스 및 스월은 펌프 입구 쪽으로 물 뿐 아니라 공기를 함께 흡입시킴으로써 펌프의 효율저하, 소음, 진동을 발생시키며 펌프 파손의 원인이 될 수 있다. 따라서 펌프를 설치하기 전 펌프 설치 후에 발생되는 펌프 흡입부 주변의 흐름특성 변화 및 흐름특성이 구조물에 미치는 영향 등을 고려하기 위하여 수리모형실험이 필요한데, 수리모형실험은 많은 시간과 비용이 들어가기 때문에 이를 대체할 수 있는 방안이 요구된다. 그런 이유로 최근에는 수리모형실험 대신 수치모의를 이용하는 경우가 많다. 수치모의의 결과는 수리실험의 결과와 비교, 검증을 거쳐 신뢰성을 얻는다. 본 연구에서는, 3차원 수치모형의 다양한 난류모델을 이용하여 흡입파이프로 물이 유입될 때 흡입부 내, 외의 수심 별 유속 변화를 분석하고, 그 결과를 이용하여 FLOW 3D 모형의 검증을 수행하였다.

  • PDF

Circuit Design for Noise Removal of Sine Wave Hall Sensor Signal (정현파 Hall Sensor 신호의 잡음제거를 위한 회로설계)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.4
    • /
    • pp.135-141
    • /
    • 2021
  • Interest is growing in the design and development of square wave driven BLDC permanent magnet motors suitable for industrial automation, and the development of position detection circuits and drivers. However, this motor is somewhat limited in its application despite the price and functional advantages due to the decrease in efficiency due to switching loss and vibration and noise. In the process of designing and assembling a BLDC motor, the magnetic pole angle is not uniform or the magnetic flux distribution is distorted due to problems in magnetic circuit design or product non-uniformity in the assembly process. Therefore, these things cause position detection deviation and deteriorate the motor characteristics. In addition, the sine wave driven BLDC system can operate stably only when the signal generated from the position sensor is accurately fed back to the driver. However, since the generated signal cannot perform stable position detection due to the occurrence of DC offset component due to magnetic flux density deviation or magnetization technology, which is an external influence, this study intends to study the proposed circuit that can remove the DC offset component.

Feasibility Study of a Corrugated Steel Protective Structure for Ammunition Test Facility (탄약시험장의 강재 방호구조물 적용성 분석 연구)

  • Han, Jae Duk;Kim, Donghee;Kim, Sungkon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.5
    • /
    • pp.671-679
    • /
    • 2022
  • Harmful factors such as shock waves and fragments are generated at domestic ammunition testing sites and military shell shooting training sites due to frequent shooting and explosion tests. As a result, complaints from local residents are rapidly increasing, and there is a high risk of damage to facilities and human life. The recently constructed ammunition test site built a test facility for firing artillery and rocket propulsion in a narrow area with a radius of 300 m due to site restrictions, but damage to the facility is accumulating because there is no adequate protective structure. Therefore, in this study, quantitative data on harmful factors such as noise, vibration, shock wave, and thermal effect generated between artillery firing and rocket propulsion tests were measured, and explosion pressure characteristics were analyzed to design a protective structure, and use Autodyn to protect performance. to perform verification.

A Study on the Harmfulness of Silicon Oxide Dust and Measures for the Work Environment Improvement in Construction Sites (건설현장에서 발생하는 산화규소분진의 유해성 및 작업환경 개선대책에 관한 연구)

  • Hwang, Jeong-Suk
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.478-486
    • /
    • 2022
  • Purpose: Although the working environment is measured at the construction site, only a few noise and vibration that are typically exposed for each process are performed without measuring the working environment by segmenting the exposed harmful factors. Therefore, it is intended to find the harmfulness of silicon oxide dust, which is most exposed at construction sites, and the complementary points of improvement measures currently being implemented at construction sites. Method: The status was analyzed using the actual condition survey report issued by the Korea Occupational Health Corporation and the Korea Occupational Health Association and data from the work environment measurement institution, and compared and analyzed with the rules on work environment measurement of the Occupational Safety and Health Act. Result: The harmfulness of silicon oxide dust was identified and improvement measures were derived. Conclusion: It is expected that occupational diseases against silicon dust can be reduced if the harmfulness of silicon oxide dust at construction sites is derived and improvement measures are actively applied at the site.

Development of roadheader performance prediction model and review of machine specification (로드헤더 장비사양 검토 및 굴착효율 예측 모델 개발)

  • Jae Hoon Jung;Ju Hyi Yim;Jae Won Lee;Han Byul Kang;Do Hoon Kim;Young Jin Shin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.3
    • /
    • pp.221-243
    • /
    • 2023
  • The use of roadheaders has been increasing to mitigate the problems of noise and vibration during tunneling operations in urban area. Since lack of experience of roadheader for hard rock, the selection of appropriate machines and the evaluation of cutting rates have been challenging. Currently, empirical models developed overseas are commonly used to evaluate cutting rates, but their effectiveness has not been verified for domestic rocks. In this paper, a comprehensive literature review was conducted to assess the rock cutting force, cutterhead capacity, and cutting rate to select the appropriate machine and evaluate its performance. The cutterhead capacity was reviewed based on the literature results for the site. Furthermore, a new empirical model and simplified method for predicting cutting rates were proposed through data analysis in relation to operation time and rock strength, and compared with those of the conventional model from the manufacturer. The results show good agreement for high strength range upper 80 MPa of uniaxial compressive strength.

A study on the relationship between exposure to hazardous and risk factors and absenteeism according to the period of the Korean Working Conditions Survey

  • Jin-Yeub Jung;Seo-Yeon Choi
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.8
    • /
    • pp.165-174
    • /
    • 2023
  • This study used Korean work environment surveys data to confirm the relationship between exposure to harmful and risk factors and absenteeism of manufacturing workers according to the survey period. Accordingly, 8,318 workers in the manufacturing industry were analyzed for the same questions of harmful and risk factors in 2011 (3rd), 2017 (5th), and 2020 (6th). Work-related hazards and risks, vibration, noise, high temperature, dust inhalation, vapor inhalation, chemical handling, and infectious material handling were found to affect absenteeism more than 3/4 of the time of exposure in 2020 compared to 2011. In conclusion, it was found that non-exposure to work-related hazards and risk factors increased one survey after another, and that the time of exposure to work-related hazards and risk factors affected absenteeism.

An Experimental Study on the Reinforcement Effect of Installed Micropiles in the Surround of Footing on Dense Sand (조밀한 모래지반의 기초 인접에 설치된 마이크로파일 보강효과에 관한 실험적 연구)

  • Lee Tae-Hyung;Im Jong-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.5
    • /
    • pp.69-81
    • /
    • 2006
  • The micropile, which is a kind of the in-situ manufactured pile with small diameter of $150\sim300mm$, is constructed by installing a steel bar or pipe and injecting grout into a borehole. The application fields of micropile are being gradually expanded in a limited space of down-town area, because the micropile has various advantages with low vibration and noise in method and compact size in machine, etc. Mostly, the micropile has been applied to secure the safety of structures, depending on the increment of bearing capacity and the restraint of displacement. The micropile is expected to be used in various fields due to its effectiveness and potentiality in the future. The model test, focused on the interaction between micropile and soil in this study, was carried out. The micropile is installed in a soil adjacent to footing (concept of 'soil reinforcement'). With the test results and soil deformation analysis, the reinforcement effect (relating to bearing capacity and settlement) was analysed in a qualitative and quantitative manner, respectively. Consequently, it is expected that we nay demonstrate the improvement of an efficiency and application in the design and construction of micropile.

Analysis Method Considering the Ground Reinforcement Effect of Micropile by Field Loading Tests (재하시험을 통한 소구경말뚝의 지반보강효과를 고려한 해석법)

  • Hong, Seok-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.1
    • /
    • pp.89-99
    • /
    • 2009
  • Compared to standard piling methods, micropile construction can be used in downtown areas since it generates less vibration and noise. Since it only causes less soil disturbance, it is commonly used as reinforcement to existing structures. In this study, a field wherein the bearing capacity and settlement of soil can not support the weight of the superstructure was selected and micropiles were implemented instead of ordinary piles. The deformation modulus of the micropile reinforced ground was determined and was directly reflected in the design. Loading testing was used to check whether or not the allowable bearing capacity satisfies the condition of the designed bearing capacity. The computed deformation modulus based from the test was used in the numerical analysis of soil to investigate the stability of the foundation and analysis method. And a method for controlling the bearing capacity and settlement was recommended.

An Experimental Study on the Reinforcement Effect of Installed Micropile under Footing on Dense Sand (조밀한 모래지반의 기초하부에 설치된 마이크로파일 보강효과에 관한 실험적 연구)

  • Lee, Tae-Hyung;Im, Jong-Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3C
    • /
    • pp.191-200
    • /
    • 2006
  • The micropile, which is a kind of the in-situ manufactured pile with small diameter of 100~300mm, is constructed by installing a steel bar or pipe and injecting grout into a borehole. The application fields of micropile are being gradually expanded in a limited space of down-town area, because the micropile has various advantages with low vibration and noise in method and compact size in machine, etc. Mostly, the micropile has been applied to secure the safety of structures, depending on the increment of bearing capacity and the restraint of displacement. The micropile is expected to be used in various fields due to its effectiveness and potentiality in the future. The model test, focused on the interaction between micropile and soil in this study, was carried out. The micropile is installed under footing(concept of "structure supporting"). With the test results and soil deformation analysis, the reinforcement effect(relating to bearing capacity and settlement) was analysed in a qualitative and quantitative manner, respectively. Consequently, it is hoped to demonstrate the improvement of an efficiency and application in the design and construction of micropile.