• Title/Summary/Keyword: 진단응력

Search Result 332, Processing Time 0.027 seconds

Computational Analysis of the Jinjeonsaji Three-Storied Stone Pagoda through the Finite Element Method (유한요소법을 이용한 진전사지 삼층석탑의 전산해석)

  • Kim, Kyun-Ho;Chung, Jae-Ung
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.6
    • /
    • pp.213-221
    • /
    • 2008
  • In order to examine the safety of stone-built historic properties, it is necessary to apply different methods to the properties according to their categories, respectively. However, there is no consensus for the criteria on which item should be examined. To make systematic preservation plans for the historic stone buildings, it must be requested to consider various factors such as weights, structural imperfections, and natural disasters and so on. In this paper, the Jinjeonsaji three-storied stone pagoda were numerically analyzed through the finite element method to measure its weight and slope. In addition, it was studied how slope variations of the stone pagoda affect to the deflections and stresses caused by its weight. Finally, criterions were proposed to examine the safety of the stone pagoda.

Electromechanical Properties of Smart Repair Materials based on Rapid Setting Cement Including Fine Steel Slag Aggregates (제강 슬래그 잔골재가 혼입된 초속경 시멘트 기반 스마트 보수재료의 전기역학적 특성)

  • Tae-Uk Kim;Min-Kyoung Kim;Dong-Joo Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.4
    • /
    • pp.62-69
    • /
    • 2023
  • This study investigated the electromechanical properties of cement based smart repair materials (SRMs) according to the different amounts of fine steel slag aggregates (FSSAs). SRMs can self-diagnose the quality of repairing and self-sense the damage of repaired zone. The replacement ratios of FSSAs to sand for SRMs were 0% (FSSA00), 25% (FSSA25), and 50% (FSSA50) by sand weight. The electrical resistivity of SRMs generally decreased as the compressive stress of SRMs increased: the electrical resistivity of FSSA25 at the age of 7 hours decreased from 78.16 to 63.68 kΩ-cm as the compressive stress increased from 0 to 22.37 MPa. As the replacement ratio of FSSAs by weight of sand increased from 0% to 25%, the stress sensitivity coefficient (SSC) of SRM at the age of 7 h increased from 0.471 to 0.828 %/MPa owing to the increased number of partially conductive paths in the SRMs. However, as the replacement ratio of FSSAs further increased up to 50%, the SSC decreased from 0.828 to 0.649 %/MPa because some of the partially conductive paths changed to continued conductive ones. SRMs are expected to self-sense the quality and future damage of repaired zone only by measuring the electrical resistivity of the repaired zone in addition to fast recovery in the mechanical resistance of structures.

Uniaxial Compression Behavior of RC Columns Confined by Carbon Fiber Sheet Wraps (탄소섬유쉬트로 구속된 RC 기둥의 일축압축 거동)

  • Han, Sang-Hoon;Hong, Ki-Nam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.2
    • /
    • pp.207-216
    • /
    • 2005
  • External confinement by CFS (Carbon Fiber Sheet) is a very effective retrofit method for the reinforced concrete columns subject to either static or seismic loads. For the reliable and cost-effective design of CFS, an accurate stress-strain model is required for CFS-confined concrete. In this paper, uniaxial compression test on short RC column with square section was performed. To evaluate the effect of confinement on the stress-strain relationship of CFS-confined concrete, CFS area ratio and tie area ratio are considered. Based on the experimental results, a stress-strain model is proposed for concrete confined by CFS wraps. In the development of the model, the method to compute the actual hoop strains in CFS jackets at the rupture was examined and resolved. Overall, the results of the model agree well with test data.

Basic Properties of Polymer Cement Mortar with EVA Emulsion and Admixtures (EVA 에멀젼과 혼화재를 사용한 폴리머 시멘트 모르타르의 기초적 성질)

  • Jo, Young-Kug
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.6
    • /
    • pp.53-60
    • /
    • 2019
  • The purpose of this study is to evaluate the degree of improvement in strengths by mixing blast-furnace slag and fly ash in polymer cement mortar(PCM). The test specimens are prepared with EVA polymer dispersion, two types of Admixtures (blast-furnace slag and fly ash), five kinds of polymer-cement ratios (0, 5, 10, 15 and 20%), and six kinds of admixtures (0, 3, 5, 10, 15 and 20%). Plain cement mortar is also made for comparison. From the test results, the flowing of PCM is greatly improved with the mixing of the admixtures, and strengths of PCM compared to ordinary cement mortar are also improved due to a decrease in water cement ratio. In addition, the strength characteristics of PCM by admixtures are greatly improved in flexural strength with fly ash compared to other strengths. It is apparent that the optimum mix proportions with polymer-cement ratio of 10% or more, admixture contents 5 to 10% of flay ash for flexural strength improvement of EVA-cement mortar are recommended in this study.

Thermal Response of Concrete in Steel-Concrete Composite Structure (복합구조 적용에 따른 콘크리트 열 응답)

  • Son, Young-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.185-191
    • /
    • 2003
  • This paper presents the thermal problems of steel-concrete composite structure and the basic references in placing concrete into the structure. Based on the analytical investigation, application of the composite structure has the effect of highly decreasing the temperature difference between the center section and the surface section of the structure, though its application has little influence on the decrement of the maximum temperature under the same using material and placing temperature. Meanwhile, its application causes the section decrement of a concrete structure, and in the section which the decrement ratio is relatively large, the restraint action by a old concrete structure takes place highly tensile stresses over a tensile strength. And, the stress is concentrated on sharp edges of the steel-concrete boundary. Both restraint action and stress concentration considerably decrease the reduction effect of the temperature difference. Therefore, the prediction of thermal response and the reasonable steps are required through the simulation considering the factors and the sections related to those problems.

An Experimental Study on Allowable Compressive Stress at Prestress Transfer in Pre-Tensioned Concrete Members (프리텐션된 콘크리트 부재의 프리스트레스 도입시 허용압축응력에 관한 실험적 연구)

  • Lee, Jeong Yeon;Lee, Deuck Hang;Kim, Kang Su;Park, Min Kook;Yoon, Sang Chun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.9-17
    • /
    • 2012
  • In the previous research, allowable compressive stress was analyzed based on strength theory, in which primary effect factors on the allowable compressive stress, such as eccentricity ratio, section type, section size, prestress and self-weight moment, were considered. As its results, allowable compressive stress equations were proposed. As a series of the previous research, this paper presents an experimental study on the prestress at transfer of pre-tensioned members with different eccentricity ratios. The results shows that ACI318-08 and EC2-02 are unconservative for the members under low eccentricity ratios, and they are conservative for the members under high eccentricity ratios. Compared to the code provisions, the results indicates that the proposed equation reasonably well evaluates the allowable compressive stresses for those with different eccentricity ratios.

Structural Stability Analysis Study for Existing Subway Tunnels Using a 3D Stress-Pore Pressure Coupled Finite Element Modelling of NATM Tunneling (NATM 터널굴착시 응력-간극수압 연계 3차원 유한요소모델링을 통한 기존 지하철터널의 구조적 안정성 해석연구)

  • Kong, Byung-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.6 s.58
    • /
    • pp.192-203
    • /
    • 2009
  • In the new Seoul-Busan high speed railroad construction specially in area of city center passage the roadbed establishment is recommended the staibility for the existing subway tunnel segments of Busan subway 1st and 2nd lines regarding the appearance condition, a quality condition and the durability of the objective facility, and it evaluates the numerical analysis using MIDAS/GTS which leads the stability of the objective facility and investigatesd tunnels. Fundamental issues in tunneling under high groundwater table are discussed and the effect of groundwater on tunnel excavation was examined using a 3D stress-pore pressure coupled Finite-Element Method. Based on the results the interaction mechanism between the tunnelling and groundwater is identified. In the both of 1st and 2nd Line the maximum sinkage, unequal sinkage and the lining stress from numerical analysis are within permission and the damage degree is appearing to be disregarded. But it enforces necessary Pre-grouting in order to minimize an actual tunnel face conduct and when the tunnel is excavated it is also necessary to minimize the outflow possibility.

Stress-strain Model of Laterally Confined High-strength Concrete with the Compressive Fracture Energy (압축파괴에너지를 도입한 횡구속 고강도 콘크리트의 응력-변형률 모델)

  • Hong, Ki-Nam;Shim, Won-Bo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.54-62
    • /
    • 2019
  • In this paper, a stress-strain model for high-strength confined concrete is proposed using compressive fracture energy. In the compression test performed by author in Reference [6], an acrylic bar with strain gauges was embedded in the center of the specimen to measure the local strain distribution. It was found from the test that the local strain measurement by this acrylic rod is very effective. The local fracture zone length was defined based on the local strain distribution measured by the acrylic rod. Specifically, it was defined as the length where the local strain increases more than twice of the strain corresponding to maximum stress. In addition, the stress-strain relationship of confined concrete with compressive fracture energy is proposed on the assumption that the amount of energy absorbed by the compressive members subjected to the given lateral confining pressure is constant regardless of the aspect ratio and size. The proposed model predicts even results from other researchers accurately.

Experimental Study on Behaviors of Prestressed Concrete Beam Reinforced by Prestressed External Tendon (단면 보강용 외부 긴장 강선을 사용한 프리스트레스트 콘크리트 보의 거동에 관한 실험적 연구)

  • Park, Chan-Sol;Kim, Kee-Dong;Han, Taek-Hee;Latif, Abdul;Kim, Doo-Kie
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.222-229
    • /
    • 2022
  • The extensive use of external prestressing system with PSC-I beam to strengthen reinforced and prestressed concrete members requires the full understanding of the behavior of the strengthened members. The main approach of this research was to experimentally investigate the flexural performance of the PSC-I beam considering external tendon and an equation was developed which indicated the produced incremental stress in the tendon due to applied load. Further, this equation was verified through performing static loading tests on two experimental specimens considering the presence or absence of external tendon. The test results revealed that, the flexural performance enhanced due to the use of external tendon. Moreover, the magnitude of the estimated flexural strength using proposed stress increasing equation almost coincides with the experimental test results. However, it was the evident of the improvement of the flexural performance of the system by reinforcing with the external tendon and also proved that the proposed equation was valid and effective.

Fatigue Evaluation of a Steel Bridge in Service through Stress History Measurement and Consideration of Stress Category (공용중인 교량의 응력이력 계측 및 응력범주를 고려한 피로평가)

  • Na, Sung-Ok;Kwon, Min-Ho;Cha, Cheol-Jun;Kim, In-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.108-116
    • /
    • 2014
  • The proper stress history measurement should be conducted in order to examine the accurate cause of fatigue cracks or the fatigue safety in the steel bridge. Only one strain gauge is generally installed in the field for the stress history examination because of the field circumstances, economic feasibility, workability, and so on. However, this method may not consider the actual size of the specific structure, the gauge length, and the affect of stress concentration in the welded joint. In addition, it is difficult to apply for the stress analysis. Therefore, this study suggests improvements that are a great number of gauge installations, the gauge location adjustment, and the use of the minimum length gauge. It is drived the correlative equation of strain for the distance between the welding toe and the strain gauge installation, and compare correlative equation with equation of IIW. Also, this study could estimate the remaining life and fatigue damage of bridge in service by selecting the suitable stress category. In conclusion, it is possible to understand the member which is high in the fatigue cracks, and the quantitative relations between the welding toe and the strain gauge installation distances. The proposed approach in this study can make an more accurate fatigue damage and a remaining life prediction so that the improved method should be applied in measuring the strain of bridges from now on.