• Title/Summary/Keyword: 직접측정

Search Result 3,867, Processing Time 0.072 seconds

Analysis of Fatigue Crack Opening: Belhlavioll Using Direct Measuring Method (직접측정법에 의한 피로크랙 개구거동의 해석)

  • Song, Sam-Hong;Kim, Hyun
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.8
    • /
    • pp.1493-1502
    • /
    • 1992
  • The purpose of this study is to identify the effects of loading variables on fatigue crack opening behavior, using structural steel SS41. To use various stress ratios, three kinds of the methods varying stress ratio were used; .DELTA.P const., P$_{max}$ const., and P$_{min}$ const.. To measure the opening load, the direct measuring method which measures the distance between two micro indentations 20 .mu.m behind crack tip and the elastic compliance method were used. As the results of present study, the following conclusions are obtained. First, using the direct measuring method, it was possible to measure the COD at any location behind crack tip. Second, as measuring point becomes farther from crack tip, opening load becomes smaller. Third, the acceleration of da/dN near notch is due to crack opening behavior. Finally, opening ratio is a function of not only R, but .DELTA.K.K.K.

A Study on Shear Stress Distribution in a Open Channel (개수로에서의 바닥전단응력 분포 분석)

  • Kim, Min Gyu;Kang, Kimchhun;Oh, Jun Oh;Park, Jae Hyeon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.445-445
    • /
    • 2016
  • 급변하는 개수로 흐름에서 발생하는 바닥전단응력의 분포는 하천구조물 설계에 있어 매우 중요한 요소이다. 하천 구조물 중 호안에 대한 하천설계기준 '설계편 제 24장 호안'에는 호안 설계에 대한 일반적인 사항이 제시 되어 있으나, 구체적인 소류력 또는 유속에 대한 기준, 각 호안공법들의 안정성을 평가하기 위한 시험법 등에 대한 구체적인 기준이 부족한 상황이다. 소류력 측정방법에는 간접측정법과 직접측정법이 있다. 간접측정법에는 Reach-Average공식, Reynolds Stress, TKE공식 (Turbulent Kinetic Energy)이 있고 직접측정법에는 Shear Meter, Preston Tube 등이 있다. 본 연구에서는 바닥전단응력을 직접 측정할 수 있는 1차원 소류력 측정장치를 개발하고, 최대유속 5m/s 가변형 고속수로 실험을 통하여 Reach-Average 공식, Reynolds Stress, TKE 공식으로 산정한 바닥전단응력 값과 1차원 소류력 측정장치 값을 비교 분석하였다. 실험케이스는 총 3개로, 22.42???, 30.00???, 41.00??? 유량을 사류이면서 난류인 상태로 실험을 수행하였다. 분석 결과, 본 연구에서 개발한 1차원 소류력 측정장치의 측정값은 TKE공식과 약 2.3% 차이가 났으며, Reach-Average공식과 약 8.1%, Reynolds Stress는 약 22.1% 차이가 났다. 즉, 본 연구에서 개발한 1차원 소류력 측정장치는 유속 범위(1m/s ~1.6m/s )에서 TKE공식을 이용한 바닥전단 응력과 가장 근사하게 나타나는 것으로 분석되었다.

  • PDF

Improvement of Direct Measurement of Bottom Shear Stress Using Shear Plate (전단평판을 이용한 바닥전단응력의 직접 측정 방법의 개선)

  • Jung, Dong Gyu;Kim, Young Do;Park, Yong Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.70-70
    • /
    • 2016
  • 하천시설물 설계, 시공 및 관리에 있어서 바닥전단응력은 매우 중요하다. 예를 들어, 호안 등 시설물의 허용 소류력을 계산하거나, 하천의 유사량을 예측하는 데 있어서 바닥전단응력이 기준으로 쓰인다. 정상 등류의 경우, 수로 내 수체에 작용하는 중력과 수로 바닥 및 측면에 작용하는 마찰력의 평형을 고려함으로써 바닥전단응력을 산정할 수 있다. 본 연구에서는 식생을 제외한 아크릴수로에서의 전단판의 움직임을 이용한 바닥전단응력 측정장치를 설계, 교정 및 검증을 실시하였다. 이 전단판은 수체와 바닥면에서 발생하는 마찰력에 의해 변위가 발생하고 이 변위를 바닥전단 응력으로 산정하였다. 직접 측정한 바닥전단응력은 기존에 연구된 두 가지 방법과 비교하여 검증하였다. 비교 검증을 위한 실험은 폭 0.3 m, 길이 10 m인 고속수로에서 Froude수 1이상, Reynolds수 20000이상의 사류이면서 난류인 상태로 실험을 진행하였으며 유속은 PIV을 이용하여 측정하였다. 비교 검증을 위한 첫 번째방법은 Reach-avrage공식을 기초로 manning의 평균 유속 공식을 이용한 바닥전단응력을 산정하는 방법으로 일반적으로 간단한 경험식을 이용하여 바닥 전단응력을 산정하는 방법이다, 두 번째는 Reynolds stress를 산정하는 방법으로 PIV를 통해 흐름방향의 연직프로파일의 유속을 측정 한 후 레이놀즈 분해법에 의해 산정된 난류 강도를 측정하여 Reynolds stress를 산정한 후 Shear stress를 산정하는 방법을 사용하였다. 마지막으로 본 연구에서 가로 0.14 m, 세로 0.14 m의 전단판으로 구성된 바닥전단응력 측정장치를 개발하여 실험을 진행하면서 앞에서 언급한 두가지 방법을 측정하는 동시에 장치를 이용하여 바닥전단응력을 직접측정하여 총 3가지 바닥전단응력을 비교하였다.

  • PDF

A Study for Indirect Channel Noise Measurement in Powerline Communications (전력선 통신 채널의 간접 잡음 측정에 대한 방안 연구)

  • Son, Hyun-Il;Oh, Hui-Myoung;Lee, Jae-Jo;Lee, Won-Tae;Kim, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2611-2613
    • /
    • 2002
  • 본 논문에서는 전력선 통신 채널의 간접 잡음 측정에 대한 연구를 하였다. 주위 환경에 의한 Noise 및 여러 통신매체에 의한 방해전파에 의해 전력선 통신 채널은 송신 측의 고출력 요구와 가능한 전력선 통신의 대역폭이 감소하는 악화된 통신환경을 보여 준다. 이러한 Noise를 측정하는 방법은 Coupling Capacitor를 이용한 직접 측정 방식과 이동 측정 장치를 이용한 간접 측정 방식이 있다. 전자는 광범위한 측정지역과 측정장비의 설치 등에서의 번잡함으로 효과적인 Noise 측정이 어렵다. 본 논문에서는 두 가지 방식의 Noise 측정 결과의 비교 및 검토를 통해 이동 측정 장치를 이용한 방식의 장점과 보완할 점을 검토였으며, 특히 직접 측정 방식과의 결과 값의 차이를 보상할 수 있는 상관관계 분석의 필요성을 고찰하였다.

  • PDF

Feasibility about the Direct Measurement of 226Ra Using the Gamma-Ray Spectrometry (감마분광분석을 이용한 226Ra의 직접 측정방법에 대한 적용성 평가)

  • Ji, Young-Yong;Chung, Kun Ho;Lim, Jong-Myoung;Kim, Change-Jong;Jang, Mee;Kang, Mun Ja;Park, Sang Tae;Woo, Zuhee;Koo, Boncheol;Seo, Bokyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.2
    • /
    • pp.97-105
    • /
    • 2014
  • In the case of the direct measurement of $^{226}Ra$ using a HPGe gamma-ray spectrometer, the interference between gammarays with 186.21 keV of $^{226}Ra$ and 185.7 keV of $^{235}U$ should be corrected to calculate the net peak area in the energy spectrum. In general, it is very difficult to conduct peaks stripping with difference of about 0.5 keV, although a HPGe with the superior resolution is applied and the maximum channels is applied to the spectrometer. In this study, several interference correction techniques in the direct measurement were surveyed to evaluate the feasibility for the measurement of $^{226}Ra$ using the gamma-ray spectrometery. Applying the interference corrections to the analysis of raw materials and by-products, the method validation for the direct measurement of $^{226}Ra$ was conducted by evaluating the measurement uncertainty, linearity, and range. As a result, the optimum method of the interference correction was selected by comparing with the indirect measurement of which progenies of $^{226}Ra$, such as $^{214}Pb$ and $^{214}Bi$, were analyzed in the secular equilibrium state.

A Study on the Estimation of Dilution Factors by Sensory Dilution Method and Triangular Bag Method (공기희석 관능법과 삼점비교식 냄새봉지법에 의한 희석배율 산정에 대한 연구)

  • 양성봉
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.103-104
    • /
    • 2000
  • 우리나라의 악취배출 허용기준에는 직접관능법, 공기희석관능법 및 기기분석법에 의한 측정과 규제 기준을 제시하고 있다. 직접관능법의 경우 신속하고 간편하여 현장에서 바로 판정을 내릴 수 있다는 점에서 부지경계선상에서의 악취의 평가수단으로 이용되어 현재까지 많은 평가서에 측정결과를 제시하고 있다. 그러나 직접관능법에 의한 평가결과가 규제치를 넘어 법적 조치가 이루어진 사업장은 거의 없는 듯하다. (중략)

  • PDF

숫돌면의 직접관찰에 의한 드레싱 시기 최적화

  • 김선호;안중환;박화영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.51-55
    • /
    • 1996
  • 본 연구에서는 숫돌면의 직접관찰에 의해 적정한 드레싱 시기를 결정하는 것에 관한 연구를 수행했다. 이를 위해, 와전류센서를 숫돌주위에 설치하여 숫돌면의 눈막힘량을 비접촉식으로 직접 측정하므로서 숫돌의 상태를 검출했다. 숫돌의 재생작용에 의한 정상연삭과 눈막힘에 의한 이상연삭의 구분은 검출된 눈막힘량과 가공면 표면거칠기의 상관괘적(Relational Locus)을 통해 드레싱 시기를 결정했다. 또한 이때의 숫돌면의 상태를 레이져 변위센서를 이용해 측정하고 3차원 Topography로 표현했다. 본 논문에서는 이러한 내용들에 대한 실험적 결과들을 소개한다.

  • PDF

원자로냉각재 RTD우회배관 제거 전후의 계통측정 정확도 평가

  • 이재용
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.345-350
    • /
    • 1997
  • 1980년대 이후로 원자로냉각재 온도를 계측하기 위한 RTD우회배관 계통을 제거하고 RCS 배관에 직접삽입식 RTD를 설치하여 온도를 계측하고 있다. 이에 고리 1,2,3,4호기에서도 직접삽입식 RTD를 설치하고자 한다. 이때 고온관 온도층화에 의한 계통측정정확도(PMA)가 설비 개선후 어떻게 변하는지 평가하였다. 평가 결과 RTD우회배관 계통의 PMA는 1.3℉F이고 직접삽입식 RTD 계통은 1.0℉로 계산되어 설비 개선후의 불확실도가 작아짐을 확인하였다.

  • PDF

Automatic Flow Measurement by Acoustic Velocity Sensors on a Weir (기존 보와 유속센서를 활용한 자동유량측정)

  • Kim, Dong-Gu;Kim, Won;Lee, Chan-Joo;Kim, Chi-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.851-854
    • /
    • 2007
  • 기존 보를 활용하여 유량측정에 이용하는 방법은 보의 통제 특성을 이용한 것이다. 유량과 수위를 병행 측정하여 얻은 자료를 활용해 수위-유량관계를 개발하는 것이다. 이 방법은 간단하면서도 정확도가 높은 방법이다. 수위-유량관계가 개발되면 별도의 측정을 수행할 필요 없이 수위계 측정값으로 유량이 계산되기 때문이다. 물론 주기적인 수위-유량관계 검증은 반드시 필요하다. 이런 수위-유량관계를 이용한 기존 보 활용은 매우 유용한 방법 중 하나이다. 하지만 이런 기존 보를 활용해 유량을 계산하는 방법은 몇 가지 단점을 포함한다. 첫째, 통제 특성을 이용하는 모든 측정 구조물은 측정한계 조건이 있다. 즉, 보 마루에 한계류가 발생하지 않는 수위 이상으로 높아지면 보의 통제 특성이 소멸되고 수위-유량관계나 유량공식은 의미가 없어진다. 둘째, 유량측정 구조물의 가장 큰 문제점 중 하나가 토사퇴적이다. 특히 기존 보의 경우 토사가 퇴적되면 보 상류의 저류용량이 줄어 보의 통제 기능을 상실하게 된다. 이런 문제점들을 해결하기 위해 보마루를 높인다거나 정기적인 준설을 하는 방법이 있다. 장기적인 변화에 대응하는 것이지만 이런 조치는 임시방편일 뿐이다. 이런 문제를 해결하기 위해 연구하게 된 방법이 보마루에서 직접 유속측정을 하는 것이다. 그리하면 통제특성을 이용한 수위-유량관계가 필요 없게 된다. 이때 보마루에서 직접 유속측정을 하기 위해서 유속측정 센서를 이용한다. 유속측정센서는 도플러방식을 이용한 초음파 유속센서로써 uplooking 방식으로 보마루에 고정시켜 이용한다. 이런 센서는 관수로에서 유량을 측정하기 위해 많이 사용되고 있다. 본 연구를 위해 초음파 센서를 이용해 실험 수로에서 유속측정과 유량환산 결과를 비교해 보았고 실제 시험하천에서도 설치하여 적용해 보았다. 보마루라는 안정된 단면을 이용하여 유속을 직접 측정하는 방법은 앞서 언급했던 수위-유량관계를 이용한 기존 보 활용법상 단점도 극복할 수 있다. 즉 통제 특성과는 관계없이 측정할 수 있는 수심 범위에만 들어가게 되면 항상 측정이 가능하고 상류의 토사퇴적에도 영향을 전혀 받지 않는다. 설치한 후 센서가 파손되지 않고 관리만 잘 된다면 유량측정시 편리하고 정확하게 결과를 얻을 것으로 판단된다.

  • PDF

피로균열진전거동 평가를 위한 균열길이 측정법 - 직류전위차법

  • 한승호
    • Journal of the KSME
    • /
    • v.37 no.10
    • /
    • pp.41-46
    • /
    • 1997
  • 철강구조물 부재 내에 노치나 균열이 존재할 수 있고, 외부의 피로하중에 의하여 취약부에서 발생한 균열이 진전하여 전구조물의 최종파손을 야기시킬 수 있다. 부재를 보다 안전하게 사용하고 또한 신뢰성을 확보하기 위해서는 이미 손상된 부재에서 균열의 진전상태를 계측할 수 있는 방법이 확립되어져야 하고, 파괴역학적 파라미터를 이용한 사용재의 균열진전거동특성이 평가되어야 한다. 균열길이의 측정방법은 지금까지 많은 연구자들에 의하여 개발되어져 왔는데 크게 광학현미경을 이용하여 육안으로 직접 균열길이를 측정하는 방법과 컴플라이언스, 초음파, AE 또는 전기적 신호를 통하여 얻어진 결괄부터 균열길이로 환산하는 간접적인 방법으로 대별된다. 대부분의 균열길이의 측정방법은 많은 수작업이 요구되고, 특히 하한계응력확대계수영역의 미세한 균열진전량을 측정하기에는 어려움이 따르고 있다. 이에 대하여 전도체 시험편에 일정전류를 흐르게 하고 균열길이의 증가에 따라 변화하는 전위차로 이를 균열길이로 평가하는 전기적인 측정방법이 있다. 이 방법은 실험장치가 비교적 간단하고 미세한 균열길이의 측정이 용이하여 균열길이의 직접적인 측정이 곤란한 고온역 그리고 충격하중하에서의 균열길이 측정에 이용이 확대되고 있다. 이 글에서는 여러 균열길이 측정방법의 장.단점에 대하여 고찰하고, 그 중 많은 장점을 갖고 있는 직류전위차법의 실험방법을 소개한다.

  • PDF