• 제목/요약/키워드: 직접측정법

Search Result 739, Processing Time 0.029 seconds

A W-Band Millimeter-Wave Power Standard Transfer System Using the Direct Comparison Method (직접 비교법을 이용한 W-Band 밀리미터파 전력 표준 전달 시스템)

  • Kwon, Jae-Yong;Kang, Tae-Weon;Kang, Jin-Seob;Lee, Dong-Joon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.47-54
    • /
    • 2013
  • This paper introduces a W-band millimeter-wave power standard transfer system using the direct comparison method. The transfer system was developed to evaluate the effective efficiency and calibration factor of a W-band waveguide power sensor. The evaluation method and the measured results of the directional coupler that characterizes the calibration system are studied. The uncertainties of the standard transfer system are investigated, and the major uncertainty contributors are discussed as well. The performance of the realized W-band power standard transfer system was verified by comparing results with reference values.

Bonding Characteristics of Directly Bonded Si wafer and Oxidized Si wafer by using Linear Annealing Method (선형열처리법으로 직접 접합된 Si 기판 및 산화된 Si 기판의 접합 특성)

  • Lee, Jin-Woo;Gang, Choon-Sik;Song, Oh-Seong;Ryu, Ji-Ho
    • Korean Journal of Materials Research
    • /
    • v.10 no.10
    • /
    • pp.665-670
    • /
    • 2000
  • Linear annealing method was developed to increase the bond strength of Si wafer pair mated at room tem­perature instead of conventional furnace annealing method. It has been known that the interval of the two mating wafer surfaces decreases and the density of gaseous phases generated at the interface increases with increase in an-nealing temperature. The new annealing method consisting of one heat source and light reflecting mirror used these two phenomena and was applied to Si$\mid$$\mid$Si and Si$\mid$$\mid$$SiO_2/Si$ bonding. The bonding interface observed directly by using IR camera and HRTEM showed clear bonding interface without any unbonded areas except the area generated by the dusts inserted into the mating interface at the room temperature. Crack opening method and direct tensile test was ap­pplied to measure the bond strength. The two methods showed similar results. The bond strength increased continuous­tly with the increase of annealing temperature.

  • PDF

A Study on Accelerated Built-in Self Test for Error Detecting in Multi-Gbps High Speed Interfaces (수 Gbps 고속 인터페이스의 오류검출을 위한 자가내장측정법의 가속화 연구)

  • Roh, Jun-Wan;Kwon, Kee-Won;Chun, Jung-Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.226-233
    • /
    • 2012
  • In this paper, we propose a 'linear approximation method' which is an accelerated BER (Bit Error Rate) test method for high speed interfaces, based on an analytical BER model. Both the conventional 'Q-factor estimation method' and 'linear approximation method' can predict a timing margin for $10^{-13}$ BER with an error of about 0.03UI. This linear approximation method is implemented on a hardware as an accelerated Built-In Self Test (BIST) with an internal BERT (BET Tester). While a direct measurement of a timing margin in a 3Gbps interface takes about 5.6 hours with $10^{-13}$ BER requirement and 95% confidence level, the accelerated BIST estimates a timing margin within 0.6 second without a considerable loss of accuracy. The test results show that the error between the estimated timing margin and the timing margin from an actual measurement using the internal BERT is less than 0.045UI.

Cable Tension Measurement of Long-span Bridges Using Vision-based System (영상처리기법을 이용한 장대교량 케이블의 장력 측정)

  • Kim, Sung-Wan;Cheung, Jin-Hwan;Kim, Seong-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.115-123
    • /
    • 2018
  • In a long-span bridge, the cables are important elements that support the load of the bridge. Accordingly, the cable tension is a very important variable in evaluating the health and safety of the bridge. The most popular methods of estimating the cable tensions are the direct method, which directly measures the cable stresses using load cells, hydraulic jacking devices, etc., and the vibration method, which inverses the tensions using the cable shapes and the measured dynamic characteristics. Studies on the use of the electromagnetic (EM) sensor, which detects the magnetic field variations caused by the change in the stress of the steel in the cable, are increasing. In this study, the lift-off test, the EM sensor, and the vibration method (Vision-based System and Accelerometer) were used to measure cable tension, and their results were compared and analyzed.

Study on Optical Non-invasive Measurement of Blood Oxygen Saturation (광에 의한 비추출식 혈중 산소 포화도 측정에 관한 연구)

  • Park, Se-Kwang;Kwon, Ki-Jin
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.11
    • /
    • pp.86-91
    • /
    • 1990
  • 혈중 산소농도는 의료 분야에 기초적인 간으로 쓰이고, 이의 측정법은 오랜 역사를 가지고 있다. 현재까지 인체의 혈액 중 산소 포화도는 혈액을 직접 추출하여 조사할 수 있었으나, 이러한 직접추출 방법은 생리학적인 제조건의 변화에 따라 변할 수 있어서, 인공심장 등의 응용으로 사용될 때에는 신속한 정보를 알아야 하므로 부적합하다. 본 연구에서는 비추출식 산소 포화도를 광학적인 방법으로 연구하는데 필요한 자료 조사 및 기본 이론 분석에 있다.

  • PDF

Analysis of Sound Fields by Finite Element Method (유한요소법에 의한 음장해석에 관한 연구)

  • Choi Seok Joo;Tachibana Hideki;Park Byeong Jeon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.5
    • /
    • pp.51-58
    • /
    • 1989
  • The finite element method is usually formulated by utilizing the variation principle. In this paper, we introduce the approximate equation of finite element from Helmholtz eqation by means of the Galerkin method, which provides the best approximation of those methods known as the method of weighted residuals, and a numerical simulation based of the finite element method is applied to analysing the acoustic modes and the pattern of sound radiation in two and three dimensional sound fields. Beside the numerical calculations, the acoustic modes and the sound pressure level are mesured by scale model experiments. The finite element analysis of the model shows very good agreement with the mesured results.

  • PDF

Discharge estimation using index velocity method in the confluence of rivers affected by backwater (배수영향을 받는 하천의 합류부에서 지표유속법을 이용한 유량산정에 대한 적절성 검토)

  • Hwang Jae Sung;Oh Dong Heon;Cho Sang Uk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.307-307
    • /
    • 2023
  • 하천의 합류부는 물의 흐름에 변화가 생겨 수면 변화가 상류에 미치는 배수현상이 나타난다. 또한 한강과 평창강이 만나는 영월 지역의 경우 각 유역 면적이 비슷하기 때문에 홍수 사상에 따라 상호 배수 영향을 주어 수위에 영향을 준다. 그러므로 배수영향기간에는 하천 유량을 산정하는 기존 방법인 수위-유량관계곡선(stage-discharge relation curve)을 이용한 환산 유량은 실제 측정 유량과 차이가 있고, 연속적으로 유속을 직접 측정하여 얻은 유속과 평균유속 간의 관계를 이용한 지표유속법(index velocity method)의 적용에 대한 적절성을 검토할 필요가 있다. 본 연구에서는 강우 사상에 따른 영월군(영월대교) 지점, 영월군(팔괴교) 지점 간 기간별 상호 배수 영향을 검토하여 수위-유량관계곡선식 및 지표유속법을 비교·적용 하였고, 기간별 상하류 유량관계 및 총 유출량 분석을 실시하여 유량산정에 대한 적절성을 검토하였다. 배수 영향 발생 시 지표유속법을 이용하여 산정된 유량을 적용한 결과 상하류 유량 관계 및 총 유출량이 적절한 것으로 확인되었고, 배수 영향 기간에는 지표유속법을 활용하여 유량을 산정하는 것이 타당한 것으로 분석되었다.

  • PDF

Site attenuation theory and practice (시험장감쇠량의 이론과 실제)

  • 김기채
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.2
    • /
    • pp.39-53
    • /
    • 1991
  • 디지탈 기기를 포함한 일반적인 전기전자기기로 부터 발생하는 방해전자파는, 낮은 주파수 대역(MF, HF 대역)에서는 전원성 등의 도선을 따라서 전달(전도성 방해파)되고, 높은 주파수 대역(VHF, UHF 대역)에서는 직접 공간에 방사(방사성 방해파)된다. 이러한 전도성 및 방사성 방해파의 측정은 IEC, CISPR, FCC, VDE 등의 규격이 정하고 있는 규정에 따라서 실시된다. 이들 규격은 방해파 측정법을 규정하고 있을 뿐만 아니라, 재현성이 좋은 측정을 실현시키기 위해 측정용 시설에 대해서도 자세하게 규정하고 있다. 방사성 방해파의 측정에 사용하는 측정시설로서는, 기본적으로 야외시험장(Open Area Test Site, OATS)을 사용하도록 규정하고 있는데, 측정치의 상호연관성을 위해서는 규약에 정해진 적합성이 평 가되고 확인되어 있어야만 한다. 여기서는 방사성 방해파 측정용 시설중에서 가장 기본적이고도 중요한 야외시험장의 적합성 평가 파 라미터 - 두 지점간의 전송손실, 이를 시험장감쇠량 이라함 - 에 대하여 기술하기로 한다.

  • PDF

Full-field Distortion Measurement of Virtual-reality Devices Using Camera Calibration and Probe Rotation (카메라 교정 및 측정부 회전을 이용한 가상현실 기기의 전역 왜곡 측정법)

  • Yang, Dong-Geun;Kang, Pilseong;Ghim, Young-Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.237-242
    • /
    • 2019
  • A compact virtual-reality (VR) device with wider field of view provides users with a more realistic experience and comfortable fit, but VR lens distortion is inevitable, and the amount of distortion must be measured for correction. In this paper, we propose two different full-field distortion-measurement methods, considering the characteristics of the VR device. The first is the distortion-measurement method using multiple images based on camera calibration, which is a well-known technique for the correction of camera-lens distortion. The other is the distortion-measurement method by measuring lens distortion at multiple measurement points by rotating a camera. Our proposed methods are verified by measuring the lens distortion of Google Cardboard, as a representative sample of a commercial VR device, and comparing our measurement results to a simulation using the nominal values.

A Study on the Surface Image Velocity Measurement Using GPS Electronic Floater in Lab-Scale (Lab-Scale에서의 GPS전자부자를 이용한 표면영상유속계측 연구)

  • Lee, Chang Hyun;Lee, Jeong Min;Kim, Young Do
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.158-158
    • /
    • 2020
  • 국내외 기상이변으로 인한 하천허용유량의 초과가 많이 일어나고 있다. 이때 사람이 직접 도섭으로 하천의 정보 대한 정보를 취득하기 어렵기 때문에 간접적인 방법으로의 정보취득이 중요시 되어야 한다. 그에 따른 방법으로 주입식의 표면부자를 활용한 방법이나, PIV 기법을 활용한 표면영상유속계측법을 이용한 유속측정방법 등이 있다. 하지만 이런 표면영상유속계측법은 영상의 변위가 커지게 되어 시간간격 설정에 대한 어려움 등이 있고, 표면부자법의 경우 표면 유속을 대변 할 수 있을지에 대한 분석연구가 필요하다. 따라서 이러한 표면 영상 유속계측법과 표면부자의 수표면 유속 측정 능력 등을 분석하여 GPS 전자부자의 활용성을 확인해 보고자 하였다. Lab-Scale 수로에서 GPS전자부자를 입자로 활용하여 주입 후 흘러가는 부분을 영상촬영하고, LS-PIV 기법을 활용하여 분석한 후 검증이 된 전자유속계 (FlowTracker)의 데이터를 참값으로 비교 분석하였다. LS-PIV 기법을 통해서 GPS 전자부자의 표면 유속 측정 능력을 잘 검증해낸다면, 유속측정에 용이하고 접근성 및 안정성까지 확보할 수 있다. 더 나아가 홍수 시 사용뿐만 아니라, ADCP나 ADV로 측정이 불가능한 저수심·저유속의 중소하천에서도 적용할 수 있다. GPS전자부자의 지속적인 연구는 향후 하천 측정 시스템에 많은 도움을 줄 것으로 사료된다.

  • PDF