• 제목/요약/키워드: 직접속도 피드백제어

검색결과 14건 처리시간 0.024초

직접속도 피드백을 이용한 보의 능동진동제어 (Active Vibration Control of a Beam using Direct Velocity Feedback)

  • 이영섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.587-592
    • /
    • 2004
  • Direct velocity feedback (DVFB) control is known that it offers an unconditional stability with very high performance when the control strategy is applied at a point collocated sensor and actuator pair, because the sensor-actuator pair has strictly positive real (SPR) property. In this paper, two types of collocated sensor-actuator pairs are considered for practical active vibration control of a structure. They are a point collocated sensor-actuator pair and a point sensor-distributed actuator pair. Both pairs with DVFB sho robust stability and performance. It is noted that the collocated point sensor-actuator ultimately acts as a 'skyhook' damper, but the point sensor-distributed actuator pair with DVFB acts as a 'skyhook' rotational dmaper pair.ational dmaper pair.

  • PDF

보의 능동진동제어을 통한 직접속도 피드백의 적용성 연구 (Active Vibration Control of a Beam Using Direct Velocity Feedback)

  • 이영섭
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.619-625
    • /
    • 2004
  • Direct velocity feedback (DVFB) control is known that it offers an unconditional stability with very high performance when the control strategy is applied at a point collocated sensor and actuator pair. because the sensor-actuator pair has strictly positive real (SPR) property In this paper, two types of collocated sensor-actuator pairs are considered for practical active vibration control of a structure. They are a Point collocated sensor-actuator pair and a point sensor-distributed actuator pair. Both pairs with DVFB show robust stability and performance. It is noted that the collocated point sensor-actuator ultimately acts as a “skyhook” damper, hut the point sensor-distributed actuator pair with DVFB acts as a “skyhook” rotational damper pair.

비동위치화된 센서와 액추에이터를 이용한 외팔보의 끝단 진동에 대한 직접속도 피드백제어 (Direct Velocity Feedback for Tip Vibration Control of a Cantilever Beam with a Non-collocated Sensor and Actuator Pair)

  • 이영섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.109-114
    • /
    • 2004
  • This paper presents a theoretical and experimental study of a non-collocated pair of piezopolymer PVDF sensor and piezoceramic PZT actuator, which are bonded on a cantilever beam, in order to suppress unwanted vibration at the tip of the beam. The PZT actuator patch was bonded near the clamped part and the PVDF sensor, which was triangularly shaped, was bonded on the other part of the beam. This is because the triangular PVDF sensor is known that it can detect the tip velocity of a cantilever beam. Because the arrangement of the sensor and actuator pair is not collocated and overlapped each other, the pair can avoid so called 'the in-plane coupling'. The test beam is made of aluminum with the dimension of $200\times20\times2mm$, and the two PZT5H actuators are both $20\times20\times1mm$ and bonded on the beam out-of-phase, and the PVDF sensor is $178mm\times6mm\times52{\mu}m$. Before control, the sensor-actuator frequency response function is confirmed to have a nice phase response without accumulation in a reasonable frequency range of up to 5000 Hz. Both the DVFB and displacement feedback strategies made the error signal from the tip velocity (or displacement) sensor is transmitted to a power amplifier to operate the PZT actuator (secondary source). Both the control methods attenuate the magnitude of the first two resonances in the error spectrum of about 6-7 dB.

  • PDF

보의 진동억제를 위한 중앙화 및 비중앙화 제어의 비교 연구 (Comparison of Centralized and Decentralized Control for Vibration Suppression of a Beam)

  • 이영섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.494-497
    • /
    • 2005
  • Direct velocity feedback (DVFB) control with a collocated distributed actuator and point sensor pair is known that it offers a good stability with high performance when the control strategy is applied at the suppression of structural vibration. Also decentralized control method introduced to offer to reduce implementaion effort and malfunction due to failure in sensors and actuators of control system has become an important position in DVFB. In this paper, the decentralized control is compared with centralized control in terms of vibrational velocity reduction in a clamped-clamped beam.

  • PDF

능동음향진동제어를 위한 센서와 액추에이터의 동위치화 연구 (Collocation of Sensor and Actuator for Active Control of Sound and Vibration)

  • 이영섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.778-783
    • /
    • 2003
  • The problem considered in this paper is about the collocation of sensor and actuator for the active control of sound and vibration. It is well-known that a point collocated sensor-actuator pair offers an unconditional stability with very high performance when it is used with a direct velocity feedback (DVFB) control, because the pair has strictly positive real (SPR) property. In order to utilize this SPR characteristics, a matched piezoelectric sensor and actuator pair is considered, but this pair suffers from the in-plane motion coupling problem with the out-of$.$plane motion due to the piezo sensor and actuator interaction. This coupling phnomenon limits the stability and performance of the matched pair with DVFB control. As a new alternative, a point sensor and piezoelectric actuator pair is also considered, which provides SPR property in all frequency range except at the first resonance in very low frequency. This non-SPR resonance could be minimized by applying a phase lag compensator.

  • PDF

직접속도 피드백을 이용한 지능판의 능동구조음향제어 (Active Structural Acoustical Control of a Smart Panel Using Direct Velocity Feedback)

  • Stephen J, Elliott;Paolo, Gardonio;Young-Sup, Lee
    • 한국소음진동공학회논문집
    • /
    • 제14권10호
    • /
    • pp.1007-1014
    • /
    • 2004
  • This paper presents a study of low frequencies volume velocity vibration control of a smart panel in order to reduce sound transmission. A distributed piezoelectric quadratically shaped polyvinylidene fluoride (PVDF) polymer film is used as a uniform force actuator and an array of $4\;{\times}\;4$ accelerometer is used as a volume velocity sensor for the implementation of a single-input single-output control system. The theoretical and experimental study of sensor-.actuator frequency response function shows that this sensor-actuator arrangement provides a required strictly positive real frequency response function below about 900 Hz. Direct velocity feedback could therefore be implemented with a limited gain which gives reductions of about 15 dB in vibration level and about 8 dB in acoustic power level at the (1,1) mode of the smart panel. It has been also shown that the shaping error of PVDF actuator could limit the stability and performance of the control system.

변위 피드백을 이용한 하이브리드 제진장치의 제어 알고리즘 (A Control Algorithm of Hybrid Mass Damper Using Displacement Feedback)

  • 김병전;이상현;정란
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.140-143
    • /
    • 2011
  • 본 연구에서는 준능동형 제진장치로 복합형 제진장치(HMD, Hybrid Mass Damper)의 운용에 요구되는 제어알고리즘 개발에 대한 연구를 진행하였다. 제어력을 산정하기 위한 알고리즘 내장화 과정에서 구조물의 상태를 피드백하기 위해서는 구조물의 가속도를 계측하고 이로부터 변위, 속도를 추정하게 되는데 여기서 발생하는 오차의 문제점을 개선하기 위하여 GPS의 실시간 변위측정기술을 활용하여 변위를 직접 입력하면서 구조물의 응답을 제어할 수 있는 알고리즘을 구성하려 한다. 이 때 측정된 데이터의 값에는 잡음이 발생하고 미분기의 동적특성을 가지고 있는 HMD에 입력신호로 사용하는 경우 상당한 오차가 생기는 변위 되먹임(Feedback)의 문제점을 확인하였다. 이러한 문제점을 개선하기 위해 제진장치 입력신호의 시간간격(Time-interval)을 조정하여 오차를 줄일 수 있는 방안을 제안하였다. 수치해석결과, 입력신호에는 최적의 시간간격(Time-Interval)이 존재하였으며 이를 적용할 경우 건물의 변위와 가속도 응답을 크게 줄일 수 있음을 확인하였다.

  • PDF

능동음향진동제어를 위한 센서와 액추에이터의 동위치화 연구 (Collocation of Sensor and Actuator for Active Control of Sound and Vibration)

  • 이영섭
    • 한국소음진동공학회논문집
    • /
    • 제14권3호
    • /
    • pp.253-263
    • /
    • 2004
  • The problem considered in this paper is about the collocation of sensor and actuator for the active control of sound and vibration. It is well-known that a point collocated sensor-actuator pair offers an unconditional stability with very high performance when it is used with a direct velocity feedback (DVFB) control, because the pair has strictly positive real (SPR) property. In order to utilize this SPR characteristics, a matched piezoelectric sensor and actuator pair is considered. but this pair suffers from the in-plane motion coupling problem with the out-of-plane motion due to the piezo sensor and actuator interaction. This coupling phnomenon limits the stability and performance of the matched pair with DVFBcontrol. As a new alternative, a point sensor and distributed piezoelectric actuator pair is also considered, which provides SPR property in all frequency range when the pair is implemented on a clamped-clapmed beam. The use of this sensor-actuator pair is highly expected for the applications to more practical active control of sound and vibration systems with the DVFB control strategy.

보의 진동제어를 위한 압전 액추에이터의 길이변화 효과 연구 (Effect of Piezoactuator Length Variation for Vibration Control of Beams)

  • 이영섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.442-448
    • /
    • 2008
  • This paper presents an approach to define an optimal piezoactuator length to actively control structural vibration. The optimal ratio of the piezoactuator length against beam length when a pair of piezoceramic actuator and accelerometer is used to suppress unwanted vibration with direct velocity feedback (DVFB) control strategy is not clearly defined so far. It is well known that direct velocity feedback (DVFB) control can be very useful when a pair of sensor and actuator is collocated on structures with a high gain and excellent stability. It is considered that three different collocated pairs of piezoelectric actuators (20, 50 and 100 mm) and accelerometers installed on three identical clamped-clamped beams (300 * 20 * 1 mm). The response of each sensor-actuator pair requires strictly positive real (SPR) property to apply a high feedback gain. However the length of the piezoactuator affects SPR property of the sensor-actuator response. Intensive simulation and experiment shows the effect of the actuator length variation is strongly related with the frequency range of SPR property. A shorter actuator gave a wider SPR frequency range as a longer one had a narrower range. The shorter actuator showed limited control performance in spite of a higher gain was applied because the actuation force was relatively small. Thus an optimal length ratio (actuator length/beam length) was suggested to obtain relevant performance with good stability with DVFB strategy. The result of this investigation could give important information in the design of active control system to suppress unwanted vibration of smart structures with piezoelectric actuators and accelerometers.

  • PDF

보의 진동제어를 위한 압전 액추에이터의 길이변화 효과 연구 (Effect of Piezoactuator Length Variation for Vibration Control of Beams)

  • 이영섭
    • 한국소음진동공학회논문집
    • /
    • 제18권11호
    • /
    • pp.1185-1191
    • /
    • 2008
  • This paper presents an approach to define an optimal piezoactuator length to actively control structural vibration. The optimal ratio of the piezoactuator length against the beam length when a pair of piezoceramic actuator and accelerometer is used to suppress unwanted vibration with direct velocity feedback(DVFB) control strategy is not clearly defined so far. It is well known that DVFB control can be very useful when a pair of sensor and actuator is collocated on structures with a high gain and excellent stability. It is considered that three different collocated Pairs of piezoelectric actuators (20, 50 and 100 mm long) and accelerometers installed on three identical clamped-clamped beams($30{\times}20{\times}1mm$). The response of each sensor-actuator pair requires strictly positive real(SPR) property to apply a high feedback gain. However the length of the piezoactuator affects the SPR property of the sensor-actuator response. Intensive simulation and experiment show the effect of the actuator length variation is strongly related with the frequency range of the SPR property. Thus an optimal length ratio was suggested to obtain relevant performance with a good stability under the DVFB strategy.