• Title/Summary/Keyword: 직장 종양

Search Result 181, Processing Time 0.019 seconds

Dose Distribution of Rectum and Bladder in Intracavitary Irradiation (자궁경부암 강내 방사선 조사장치에 의한 직장 및 방광의 피폭선량 평가)

  • Chu S. S.;Oh W. Y.;Suh C. O.;Kim G. E.
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.261-270
    • /
    • 1984
  • The intrauterine irradiation is essential to achieve adequate tumor dose to central tumor mass of uterine malignancy in radiotherapy. The complications of pelvic organ are known to be directly related to radiation dose and physical parameters. The simulation radiation and medical records of 203 patients who were treated with intrauterine irradiation from Feb. 1983 to Oct. 1983, were critically analized. The physical parameters to include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem applicator to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids were measured for low dose rate irradiation system and high dose rate remote control afterloading system. The radiation doses and dose distributions within cervical area including interesting points and bladder, rectum, according to sources arrangement and location of applicator, were estimated with personal computer. Followings were summary of study results ; 1. In distances between lateral walls of vaginal fornices, the low dose rate system showed as $4\~7cm$ width and high dose rate system showed as $5\~6cm$. 2. In horizontal angulation of tandem to body axis, the low dose rate system revealed mid position$64.6\%$, left deviation $19.2\%$and right deviation $16.2\%$. 3. In longitudinal angulation of tandem to body axis, the mid position was $11.8\%$ and anterior angulation $88.2\%$ in low dose rate system but in high dose rate system, anterior angulation was $98.5\%$. 4. Down ward displacement of ovoids below external os was only $3\%$ in low dose rate system and $66.7\%$ in high dose rate system. 5. In radiation source arrangement, the most activities of tandem and ovoid were 35 by 30 in low dose rate system but 50 by 40 in high dose rate system. 6. In low and high dose rate system, the total doses an4 TDF were 50, 70 Gy and 141, 123, including 40 Gy external irradiation. 7. The doses and TDF in interesting points Co, B, were 93, 47 Gy and 230, 73 in high dose rate system but in low doss rate system, 123, 52 Gy and 262, 75 respectively. 8. Doses and TDF in bladder and rectum were 70, 68 Gy and 124, 120 in low dose rate system, but in high dose rate system, 58, 64 Gy 98, 110 respectively, and then grades of injuries in bladder and rectum were 25, $30\%$ and 18, $23\%$ respectively.

  • PDF

Radiotherapy Results of Early Uterine Cervix Cancer (초기 자궁경부암의 방사선치료 성적)

  • Choi, Doo-Ho;Huh, Seung-Jae
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.33-39
    • /
    • 1996
  • Purpose : This study was done to analyze survivals, patterns of failure, and complications of early uterine cervix cancer after curative radiotherapy. Materials and Methods : Eighty patients with uterine cervix cancer FIGO Stage IB (48 cases) and Stage IIA (32 cases) treated with radiotherapy were analyzed retrospectively. Patients were treated from November 1985 to May 1993, and minimum follow up period was 24 months and 6 cases were lost to follow up. All of them were treated with external radiotherapy and different fractions of high dose rate intracavitary radiotherapy, Survival rates, failure patterns, complication rates and degrees of severity were analyzed according to several factors. Results : Overall 5 year survival rate and relapse free survival rate were $72.3\%$, and $72.8\%$ respectively. Prognostic factors were stage, size, pathology, RT response and there was no significant survival difference among the reasons of radiotherapy choice. There were 19 cases of treatment failure, another 3 cases were not tumor related death, and most of treatment related failure occurred within 24 months Late complication rate of bladder and rectum were $8.8\%,\;15\%$ respectively, frequency and severity of complication were correlated with ICR fractionation dose and total dose. Conclusion : These results showed that survival rates of early stage radiation treated cervix cancer patients were comparable to surgical series, but more aggressive treatment methods needed for stage IIA poor prognostic patients. To decrease late complication, choice of proper ICR dose and meticulous vaginal packing is needed.

  • PDF

The Role of the Postoperative Adjuvant Radiation Therapy to Primary Site in Rectal Cancer Patients with Synchronous Liver Metastasis (동시 간 전이가 있는 직장암 환자에서 원발 부위에 대한 수술 후 보조 방사선 치료의 역할)

  • Pyo Hong Ryull;Seong Jin Sil;Shin Hyun Soo;Lee Hyung Sik;Kim Gwi Eon;Suh Chang Ok;Loh John Juhn Kyu;Kim Woo Cheol
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.103-108
    • /
    • 1993
  • Among the patients with rectal cancer who entered Yonsei University Hospital for management from Jan. 1980 to Dec. 1990, we selected 23 subjects who were received surgical resection of tumor in rectum, and who proved to have liver metastasis during the diagnostic work-up, at the time of the operation, or within 3 months after starting definitive treatment. With those subjects, we investigated the role of radiation therapy by comparison of the treatment results of the patients without radiation therapy (S group) with those of the patients with radiation therapy to the primary site (S+R group). The local control rates of S group and S+R group were $64{\%}$ and $89{\%}$, and 2-year survival rates were $50{\%}$ and $78{\%}$, respectively. Although there was not statistically meaningful difference, local control rate and 2-year survival rate were higher in the group with radiation therapy to primary site than that without radiation therapy. The 2-year survival rates of the case with resection of the liver and the case without it were $63.6{\%}$ and $58.3{\%}$ respectively, which was not statistically significant. Also, the 2-year survival rate of the case with sustained local control was higher than that of the case with local failure, which was statistically significant ($76.5{\%}$ and $16.7{\%}$, p<0.005). From the above results, it is thought that radiation therapy to the primary site might improve the local control rate even in the patients with liver metastasis, which seems to be correlated to the higher survival rate.

  • PDF

The Effect of Therapy Oriented CT in Radiation Therapy Planning (치료 계획용 전산화 단층촬영이 방사선 치료계획에 미치는 효과)

  • Kim, Sung-Kyu;Shin, Sei-One;Kim, Myung-Se
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.149-155
    • /
    • 1987
  • The success of radioation therapy depends on exact treatment of the tumor with significant high dose for maximizing local control and excluding the normal tissues for minimizing unwanted complications. To achieve these goals, correct estimation of target volume in three dimension, exact dose distribution in tumor and normal critical structures and correction of tissue inhomogeneity are required. The effect of therapy oriented CT (plannng CT) were compared with conventional simulation method in necessity of planning change, set dose, and proper distribution of tumor dose. Of 365 new patients examined, planning CT was performed in 104 patients $(28\%)$. Treatment planning was changed in $47\%$ of head and neck tumor, $79\%$ of intrathoracic tumor and $63\%$ of abdmonial tumor. in breast cancer and musculoskeletal tumors, planning CT was recommended for selection of adequate energy and calculation of exact dose to critical structures such as kidney or spinal cord. The average difference of tumor doses between CT planning and conventional simulation was $10\%$ in intrathoracic and intra-abdominal tumors but $20\%$ in head and neck tumors which suggested that tumor dose may be overestimated in conventional simulation Although some limitations and disadvantages including the cost and irradiation during CT are still criticizing, our study showed that CT Planning is very helpful in radiotherapy Planning.

  • PDF

The Role of Radiation Therapy in the Unresectable Rectal Cancers (절제 불가능 직장암에서 방사선 치료의 역할)

  • Kim, Woo-Cheol;Seong, Jin-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.13 no.2
    • /
    • pp.173-180
    • /
    • 1995
  • Purpose: Unresectable rectal cancer has a grave prognosis. regardless of the therapy used and median survival is less than 1 rear. Also, it is reported by many authors that $50-80\%$ of unresectable lesions were rendered resectable by radiation therapy and the median survival time for the completely resected patients were better than that of the unresected patients. So we analyzed retrospectively our data for the better treatment outcome in these patients. Materials and MEthods:From 1980 to 1992, 45 patients with initially unresectable tumors in the rectum were treated with radiation therapy with/without surgery in Department of Radiation Oncology, Yonsei Cancer Center 10 MV radiation and multiple field technique (box or AP/PA) were used. The total dose was 28-70 Gy and median dose was 48 Gy. We evaluated the lesion status at 45-50 Gy for operability. If the lesions appeared to be resectable, the Patients were operated on 4-6 weeks after radiation therapy. But if the lesions were still fixed, the radiation dose was increased to 60-65 Gy. Results: For all patients, the 2-year actuarial survival was $13.3\%$ and median survival was 9.5 months. Of 6 patients who had received less than 45 Gy, only $17\%$ of patients responded, but in the patients who had received more than 45 Gy, $60\%$ of response rate was achieved Six of the 24 patients$(25\%)$ underwent surgical resections following RT. For patients undergoing curative resection. the two-rear survival was $50\%,$ but that of the patients without resection was $9.5\%$ (p<0.01). Survival of patients with complete response following RT was $50\%$ at 2 years. Survival of patients with partial response, stable disease and progressive disease after RT was $13.4\%,\;15.4\%,\;0\%$ respectively (P<0.05). Conclision: Our data suffests that the efforts which can increase the response rate and aggressive surgical approach are needed to achieve the better local control and survival in unresectable rectal cancers.

  • PDF

The Effect of Total Dose of Radiation on Normal Colon of Hybrid Mice (치료방사선 조사가 잡종 백색마우스의 대장에 미치는 병리조직학적 영향)

  • Jho, Gil-Ho;Kim, Myung-Se
    • Radiation Oncology Journal
    • /
    • v.4 no.2
    • /
    • pp.99-105
    • /
    • 1986
  • Optimal balance between control probability and risk of complication is emphasized even in present time, Although certain incidence of intestinal injury is accepted as an inevitable consequence after abdominopelvic irradiation, these complications still remain as problems. 60 mice were irradiated with 250 kVp orthovoltage x-ray machine and $200rad{\times}5/wk$ regimen. Histpathologic findings of colorectum and the relationship with occult blood test were analyzed and possible tolerable dose which would be safe from permanent complication was also estimated. Followings are the results: Mild mucosal and submucosal edema were observed in 1,000 rad irradiated group. Congestion of small vessels was prominent in 2,000 rad irradiated group and infiltration of inflammatory cells was observed in 3,000 rad irradiated group. Denuded mucosa was observed in 3,000 rad irradiated group. Occult blood test is not a proper indicator for rectal denuding or rectal ulcer, but our results suggest the possibility of using this as a relative scale of intestinal damage. Mitotic figures of crypt cells were observed even in 5,000 rad irradiated group, these suggest that the repair capacity of crypt cells are still functioning.

  • PDF

Locally Advanced Rectal Carcinoma : Curative Surgery Alone vs. Postoperative Radiotherapy and Chemotherapy (국소적으로 진행된 직장암에 대한 근치적 수술 단독 치료군과 수술후 보조적 방사선 및 항암화학요법 병행군의 치료결과 분석)

  • Ahn Seung Do;Choi Eun Kyung;Kim Jin Cheon;Kim Sang Hee
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.253-258
    • /
    • 1995
  • Purpose : To evaluate the effects of postoperative radiotherapy and chemotherapy on the pattern of failure and survival for locally advanced rectal carcinoma, we analyzed the two groups of patients who received curative resection only and who received postoperative radiochemotherapy retro-spectively. Materials and Methods : From June 1989 to December 1992, ninety nine patients with rectal cancer were treated by curative resection and staged as B2-3 or C. Group I(25) patients received curative resection only and group II(74) patients postoperative adjuvant therapy. Postoperative adiuvant group received radiation therapy (4500cGy/25fx to whole pelvis) with 5-FU (500mg/$m^2$, day 1-3 IV infusion) as radiosensitizer and maintenance chemotherapy with 5-FU(400mg/$m^2$ for 5 days) and leucovorin (20mg/m^2$ for 5 days) for 6 cycles. Results : The patients in group I and group II were comparable in terms of age sex, performance status, but in group II $74{\%}$ of patients showed stage C compared with $56{\%}$ of group I. All patients were followed from 6 to 60 months with a median follow up of 29 months. Three year overall survival rates and disease free survival rates were $68\%,\;64\%$ respectively in group I and $64\%,\;61\%$, respectively in group II. There was no statistical difference between the two treatment groups in overall survival rate and disease free survival rate. Local recurrences occurred in $28{\%}$ of group I, $21{\%}$ of group II (p>.05) and distant metastases occurred in $20{\%}$ of group I, $27{\%}$ of group II(p>.05). The prognostic value of several variables other than treatment modality was assessed. In multivariate analysis for prognostic factors stage and histologic grade showed statistically significant effect on local recurrences and lymphatic or vessel invasion on distant metastasis. Conclusion : This retrospective study showed no statistical difference between two groups on the pattern of failure and survival. But considering that group II had more advanced stage and poor prognostic factors than group I, postoperative adjuvant radiochemotherapy improves the results for locally advanced rectal carcinoma as compared with curative surgery alone.

  • PDF

Dose Evaluation of TPS according to Treatment Sites in IMRT (세기조절방사선치료 시 치료 부위에 따른 치료계획 시스템 간 선량평가)

  • Kim, Jin Man;Kim, Jong Sik;Hong, Chae Seon;Park, Ju Young;Park, Su Yeon;Ju, Sang Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.181-186
    • /
    • 2013
  • Purpose: This study executed therapy plans on prostate cancer (homogeneous density area) and lung cancer (non-homogeneous density area) using radiation treatment planning systems such as $Pinnacle^3$ (version 9.2, Philips Medical Systems, USA) and Eclipse (version 10.0, Varian Medical Systems, USA) in order to quantify the difference between dose calculation according to density in IMRT. Materials and Methods: The subjects were prostate cancer patients (n=5) and lung cancer patients (n=5) who had therapies in our hospital. Identical constraints and optimization process according to the Protocol were administered on the subjects. For the therapy plan of prostate cancer patients, 10 MV and 7Beam were used and 2.5 Gy was prescribed in 28 fx to make 70 Gy in total. For lung cancer patients, 6 MV and 6Beam were used and 2 Gy was prescribed in 33 fx to make 66 Gy in total. Through two therapy planning systems, maximum dose, average dose, and minimum dose of OAR (Organ at Risk) of CTV, PTV and around tumor were investigated. Results: In prostate cancer, both therapy planning systems showed within 2% change of dose of CTV and PTV and normal organs (Bladder, Both femur and Rectum out) near the tumor satisfied the dose constraints. In lung cancer, CTV and PTV showed less than 2% changes in dose and normal organs (Esophagus, Spinal cord and Both lungs) satisfied dose restrictions. However, the minimum dose of Eclipse therapy plan was 1.9% higher in CTV and 3.5% higher in PTV, and in case of both lungs there was 3.0% difference at V5 Gy. Conclusion: Each TPS according to the density satisfied dose limits of our hospital proving the clinical accuracy. It is considered more accurate and precise therapy plan can be made if studies on treatment planning for diverse parts and the application of such TPS are made.

  • PDF

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF

Analysis of Neurological Complications on Antegrade Versus Retrograde Cerebral Perfusion in the Surgical Treatment of Aortic Dissection (대동맥 박리에서 전방성 뇌 관류와 역행성 뇌 관류의 신경학적 분석)

  • Park Il;Kim Kyu Tae;Lee Jong Tae;Chang Bong Hyun;Lee Eung Bae;Cho Joon Yong
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.489-495
    • /
    • 2005
  • In the surgical treatment of aortic dissection, aortic arch replacement under total circulatory arrest is often performed after careful inspection to determine the severity of disease progression. Under circulatory arrest, antegrade or retrograde cerebral perfusion is required for brain protection. Recently, antegrade cerebral perfusion has been used more, because of the limitation of retrograde cerebral perfusion. This study is to compare these two methods especially in the respect to neurological complications. Material and Method: Forty patients with aortic dissection involving aortic arch from May 2000 to May 2004 were enrolled in this study, and the methods of operation, clinical recovery, and neurological complications were retrospectively reviewed. Result: In the ACP (antegrade cerebral perfusion) group, axillary artery cannulation was performed in 10 out of 15 cases. In the RCP (retrograde cerebral perfusion) group, femoral artery Cannulation was performed in 24 out of 25 cases. The average esophageal and rectal temperature under total circulatory arrest was $17.2^{\circ}C\;and\;22.8^{\circ}C$ in the group A, and $16.0^{\circ}C\;and\;19.7^{\circ}C$ in the group B, respectively. Higher temperature in the ACP group may have brought the shorter operation and cardiopulmonary bypass time. However, the length of period for postoperative clinical recovery and admission duration did not show any statistically significant differences. Eleven out of the total 15 cases in the ACP group and thirteen out of the total 25 cases in the RCP group showed neurological complication but did not show statistically significant difference. In each group, there were 5 cases with permanent neurological complications. All 5 cases in the ACP group showed some improvements that enabled routine exercise. However all 5 cases in RCP group did not show significant improvements. Conclusion: The Antegrade, cerebral perfusion, which maintains orthordromic circulation, brings moderate degree of hypothermia and, therefore, shortens the operation time and cardiopulmonary bypass time. We concluded that Antegrade cerebral perfusion is safe and can be used widely under total circulatory arrest.