• Title/Summary/Keyword: 직산 분리 모델

Search Result 6, Processing Time 0.014 seconds

Performance Validation of Five Direct/Diffuse Decomposition Models Using Measured Direct Normal Insolation of Seoul (서울지역 실측일사량을 이용한 일사량 직산분리 모델의 정밀성 검증 연구)

  • Yoon, J.H.
    • Solar Energy
    • /
    • v.20 no.1
    • /
    • pp.45-54
    • /
    • 2000
  • Five direct/diffuse decomposition models were validated using the eight years data set of direct normal beam insolation measured in Seoul. The comparison has been performed In terms of the widely used statistical indicators such as MBE, RMSE, CV(RMSE), t-Statistic and Degree of Agreement. Result indicates that most of the correlations exhibit a tendency to underestimate the direct normal beam insolation except Bouguer's model. Most of big discrepancies between the measured and the predicted values was mainly shown in near the sunrising and the sunset period. Even though the investigated five models showed fairly large disagreement for the measured values by 34%$\sim$48% of CV(RMSE), Udagawa's correlation which includes the effect of solar altitude variation appears to performs always better in every statistical error tests.

  • PDF

Comparative Analysis of Decomposition Models with Site-fitted Coefficients for Seoul (서울지역 지역계수가 적용된 직산분리 모델의 성능 비교)

  • Seo, Dong-Hyun;Kim, Hye-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.3
    • /
    • pp.91-102
    • /
    • 2019
  • Decomposition models are essential in TMY development and solar energy system design. Up until recently, only a few decomposition model related researches are implemented in Korea due to lack of measured direct normal solar irradiance. In contrast, numerous researches have been conducted in various countries, and some quasi-universal composition models have been recommended by several papers. In this research, three decomposition models - Watanabe model, Reindl-2 model and Engerer1 model - are selected and their site-fitted coefficients are developed using measured direct normal solar irradiance in Seoul. R-squared, RMSE, MBE of the site-fitted models are compared with the case of original coefficients and then each other. The comparison result shows that the Reindl-2 model with site-fitted coefficients is best suitable for Seoul. Further researches will be conducted to find the best model using more various measured data of Korean cities and site-fitting methods.

A Research on the Decomposition Model and Transposition Model Using the Measured Pyranometer Irradiation Data (피라노미터 실측 일조량을 통한 직산 분리 모델과 경사면 일조량 변환 모델에 관한 연구)

  • Lee, Sang-Hyuk;Lee, Kyung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.3
    • /
    • pp.1-20
    • /
    • 2018
  • It is a very important and fundamental process to know accurately the intensity of the solar energy coming into the installed module considering the tilted angle. Europe and the US commonly use a program called PVsyst to convert the global horizontal irradiation to global irradiation on tilted plane. There are two types of models that PVsyst uses to convert to irradiation on tilted plane. In this paper, Perez model, which is a decomposition model and Perez model, which is a transposition model used in PVsyst, are applied based on global horizontal irradiation and global irradiation on tilted plane measured in a specific area. The comparison of the decomposition model shows the effect of the transpostion model on global irradiation on tilted plane conversion by comparing the ratio of the horizontal diffuse irradiation amount of the Watanabe model which are highly trusted in Asia and the Perez model. The comparison of transposition model confirm the error between the measured data and the calculated value which is applied Perez model to global horizontal irradiation decomposed by Perez model and Watanabe model. Based on the two comparisons, This paper propose a method to confirm the reliability of transposition model and reduce the error when PVsyst is used in Korea.

Variation of Solar Photovoltaic Power Estimation due to Solar Irradiance Decomposition Models (일사량 직산분리 모델에 따른 표준기상연도 데이터와 태양광 발전 예측량의 불확실성)

  • Jo, Eul-Hyo;Lee, Hyun-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.3
    • /
    • pp.81-89
    • /
    • 2019
  • Long-term solar irradiance data are required for reliable performance evaluation and feasibility analysis of solar photovoltaic systems. However, measurement data of the global horizontal irradiance (GHI) are only available for major cities in Korea. Neither the direct normal irradiance (DNI) nor the diffuse horizontal irradiance (DHI) are available, which are also needed to calculate the irradiance on the tilted surface of PV array. It is a simple approach to take advantage of the decomposition model that extracts DNI and DHI from GHI. In this study, we investigate variations of solar PV power estimation due to the choice of decomposition model. The GHI data from Korea Meteorological Administration (KMA) were used and different sets of typical meteorological year (TMY) data using some well-known decomposition models were generated. Then, power outputs with the different TMY data were calculated, and a variation of 3.7% was estimated due to the choice of decomposition model.

A Study on the Effect of Particulate Matter Concentration on the Reliability of Decomposition Model (미세먼지 농도가 직산분리 모델의 신뢰성에 미치는 영향에 관한 연구)

  • Lee, Sang-Hyuk;Lee, Kyung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.4
    • /
    • pp.55-67
    • /
    • 2019
  • Recently, as the amount of particulate matter blowing from China increases, the domestic air environment is rapidly deteriorating. This pollution of the atmosphere greatly affects the light energy reaching the ground. Particularly, since the light enters the solar cell module in various forms, the amount of input energy of the solar power generation system may be changed depending on the ratio of direct beam irradiation and diffused horizontal irradiation. In this paper, we analyze how the ratio of direct beam component and diffused component on global horizontal irradiation varies with the atmospheric conditions. In addition, the reliability of the regression equation, designed to decompose the global horizontal irradiation into horizontal direct beam irradiation and diffused horizontal irradiation, was verified according to the level of air pollution. So, we derive the most suitable decomposition model for use in domestic climatic conditions in Korea by comparing the ratio of direct and diffuse component on the horizontal which is calculated with Perez model and Watanabe model using the meteorological weather data observed for 14 months. Finally, to reduce the error of the transposition result, we verified the reliability of the decomposition which depends on the atmospheric environment.

Calculation Method for the Transmitted Solar Irradiance Using the Total Horizontal Irradiance (수평면 전일사를 이용한 창 투과 일사량 계산 방법)

  • Jeon, Byung-Ki;Lee, Seung-Eun;Kim, Eui-Jong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.4
    • /
    • pp.159-166
    • /
    • 2017
  • The growing global interest in energy saving is particularly evident in the building sector. The transmitted solar irradiance is an important input in the prediction of the building-energy load, but it is a value that is difficult to measure. In this paper, a calculation method, for which the total horizontal irradiance that can be easily measured is employed, for the measurement of the transmitted solar irradiance through windows is proposed. The method includes a direct and diffuse split model and a variable-transmittance model. The results of the proposed calculation model are compared with the TRNSYS-simulation results at each stage for the purpose of validation. The final results show that the CVRMSE over the year between the proposed model and the reference is less than 30 %, whereby the ASHRAE guideline was achieved.