• Title/Summary/Keyword: 직류 방전

Search Result 115, Processing Time 0.028 seconds

Emission Spectroscopy of Unstable Molecules using a Fourier Transform Spectrometer (Fourier Transform 분광기를 이용한 불안정한 분자의 방출분광학)

  • Sang Kuk Lee;Un Sik Kim
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.4
    • /
    • pp.371-377
    • /
    • 1993
  • Fourier Transform UV/VIS spectrometer has been modified for emission spectroscopy with the technique of supersonic expansion, in which the unstable molecular radical $CH_3S$ has been generated in a jet by a high voltage DC discharge. The fluorescence spectra of the supersonically cooled radical have been recorded on a Fourier Transform UV/VIS spectrometer. The ratio of signal to noise of the spectra has been improved substantially. Also the rotational structure has been clearly resolved for $CH_3S$ molecular radical.

  • PDF

Effects of Pre-formed Space Charges by Negative DC Voltages on PD Characteristics in XLPE (부극성 직류전압에 의해 사전 형성된 공간전하가 XLPE의 부분방전특성에 미치는 영향)

  • 황보승;이준호
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.7
    • /
    • pp.310-313
    • /
    • 2003
  • The purpose of this paper is to evaluate the effects of pre-formed space charges by DC stress on partial discharge(PD) characteristics in XLPE. We have suggested a modified pulsed electro-acoustic(PEA) method and successfully measured both space charge distribution and current simultaneously. It has been demonstrated that the PD patterns are strongly influenced by the pre-formed space charge distributions, which are hardly disappeared up to AC 8㎸ in electrode configuration including air gap between XLPE layer and electrode. From the results, it could be said that the pre-formed space charges by DC stress can play harmful and dangerous roles in insulating system under AC operating voltages because of the field distortion and localization due to the pre-formed space charge.

Characteristics of DC Surface Discharge for the Development of UV Camera (자외선 카메라 개발을 위한 직류 연면방전 특성)

  • Pang, Man-Sik;Choi, Jae-Hyeong;Kim, Woo-Jin;Kim, Young-Seok;Kim, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.98-103
    • /
    • 2011
  • Recently, UV(ultra-violet rays) camera has attracted a great deal of interest from the view point of easy judgement in inspections and diagnoses of the safety of power equipment. Especilly, UV camera is applied the inspection of UV with corona discharge. One of the most important and difficult problems is the basic research of filter design, materials and corona discharge. In this paper, we will report on the UV generation, corona pulse count and the polarity effect of positive and negative DC surface discharge in air. Also, corona discharge characteristics are analyzed using prototype UV camera of Korea. UV generation and corona pulse count due to surface discharge in positive needle is higher than that of negative needle.

유도 결합 플라즈마 스퍼터 승화법을 이용한 Cr 박막 증착 및 특성 분석

  • Choe, Ji-Seong;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.243-243
    • /
    • 2012
  • 화석연료를 대체할 새로운 청정 에너지원의 요구가 높아지고 있는 현 시점에서 고효율, 무공해, 무소음 등의 장점으로 인해 친환경적 에너지원으로 연료전지의 수요가 증가하고 있다. 연료전지 분리판으로 고밀도 흑연을 종래에 가공하여 제작하였는데, 가공이 어렵고, 비용이 크게 들며, 대량생산이 어렵다는 등의 문제로 스테인리스강을 위주로 한 금속 분리판 개발이 이루어지고 있다. 본 연구에서는, 낮은 가격, 고속 증착, 우수한 가공성, 높은 기계적 강도 및 전기전도도, 화학적 안정성 및 내식성을 충족시키기 위하여 스테인리스 강박(0.1 mm이하)에 보호막으로 CrN을 선택하였다. 저가격화를 위하여 새로운 증착원인 스퍼터-승화형 소스의 가능성을 유도 결합 플라즈마에 Cr 봉을 직류 바이어스 함으로써 시도하였다. 10 mTorr의 Ar 유도 결합 플라즈마를 2.4 MHz, 400 W로 유지하면서 직류 바이어스 전력을 120 W (615 V, 0.19 A) 인가하였을 때 10분 동안의 증발양이 0.35 gr으로 측정이 되어 그 가능성을 확인할 수 있었다. 또한 OES(Optical emission spectrometer)를 이용하여 RPS로 방전시킨 고밀도 ICP를 측정한 결과 842.4 nm, 811.4 nm, 772.3 nm 등의 파장에서 높은 intensity를 갖는 peak을 찾을 수 있었고, 이 peak 들은 Ar 중성의 peak임을 확인할 수 있었다. ICP+DC bias로 Cr rod를 가열하는 공정에서의 plasma를 OES로 측정한 결과 Ar 중성의 peak은 감소하고, 520.5 nm, 425.5 nm, 357.7 nm 등의 파장에서 높은 intensity를 갖는 peak을 찾을 수 있었으며, 이 peak들은 Cr 중성의 peak임을 확인할 수 있었다. OES 측정 data를 토대로 공정 중의 rod type Cr target의 교체 주기를 예측할 수 있고 공정 중 실시간 감시가 가능할 것으로 기대된다.

  • PDF

Supercapacitor Applications for System Stabilization and Efficiency Improvement on DC Railway System (직류 도시철도 시스템 에너지 효율 향상 및 안정화를 위한 슈퍼커패시터 에너지 저장장치 활용 방안 연구)

  • Song, Ji-Young;Lee, Kye-Byung;Lee, Han-Sang;Jang, Gil-Soo;Kwon, Sae-Hyuk;Lee, Chang-Mu;Lee, Han-Min;Kim, Gil-Dong
    • Journal of IKEEE
    • /
    • v.13 no.1
    • /
    • pp.49-56
    • /
    • 2009
  • In this paper, a simulation for the stability of the catenary voltage through charging and discharging by introducing an energy storage system in the railway system and the efficient usage of restoration energy has been performed. In order for the simulation, a simple railway model with an appropriate control technique has been introduced. The catenary voltage area is divided into two areas with voltage control and an area with normal operation and current control is performed to satisfy current limit of the supercapacitor. We confirmed the energy absorption and emission through the simulation and observed energy efficiency through charging and discharging according to the operation state of the railway.

  • PDF

Modeling of Hybrid Generation System with Wind Turbine, Diesel Generator and Flywheel Energy Storage System (풍력-디젤-플라이휘일 하이브리드 발전시스템 모델링에 관한 연구)

  • Kim, Jae-Eon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2979-2984
    • /
    • 2013
  • This paper proposes a modeling and controller design method of Flywheel Energy Storage System(FESS) for solving the unstable operation problem in hybrid generation system with wind turbine and diesel generator applied in island area. FESS is considered as a permanent magnetic synchronous machine connected to flywheel because of its efficiency. The controller of FESS is composed of AC/DC/AC back-to-back converter. The AC/DC converter is designed to charge/discharge according to the frequency variation and the DC/AC converter to operate to keep the DC bus voltage constant. The proposed modeling and controller design method of FESS was applied to hybrid generation system with wind turbine and diesel generator. The unstable operation problem owing to wind variations was solved through simulation results.

플라즈마를 이용한 그래핀의 산화

  • Lee, Byeong-Ju;Jeong, Gu-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.460-460
    • /
    • 2011
  • 그래핀은 탄소원자로 구성된 2차원의 나노재료로서 우수한 기계적, 전기적, 광학적 특성을 지닌다. 이러한 특성들을 기반으로 그래핀은 디스플레이, 터치스크린, 전 자기 차폐재 등의 다양한 분야로의 응용이 가능하다고 예측되고 있다. 한편 이러한 특성은 그래핀의 구조 및 결함, 불순물 등에 의하여 변화한다고 알려져 있으며, 이러한 특성의 변화를 통해 전자소자로의 응용도 가능 하다고 예측되고 있다. 따라서 그래핀의 구조를 제어하고 적절한 결함 및 불순물을 부여하는 것은 그래핀의 기초물성 연구 뿐 아니라 응용연구 에 있어서도 매우 중요하다고 할 수 있다. 본 연구에서는 공기 플라즈마를 이용하여 그래핀의 구조변형을 도모하였다. 그래핀은 열화학 기상증착법 (thermal chemical vapor deposition; TCVD)을 이용하여 300 nm 두께의 니켈박막이 증착된 기판위에 합성하였다. 합성된 그래핀은 산화처리 시 기판의 영향을 배제하고자 트렌치(trench) 구조의 산화막 실리콘 기판위로 전사함으로서 공중에 떠 있는 (air suspended) 구조를 구현하였다. 산화처리를 위한 장치는 직류 플라즈마 장치를 이용하였으며 0.1 Torr의 압력에서 0.4W의 파워로 공기 플라즈마를 방전하여 5분간의 산화처리와 특성평가를 매회 반복함으로서 처리시간에 따른 산화처리의 영향을 관찰하였다. 그 결과 공기 플라즈마 산화처리를 통해 그래핀에 결함을 부여하고 그래핀의 구조변형이 가능함을 확인하였다. 그래핀의 특성분석을 위해서는 광학현미경, 라만 분광기, 원자간힘현미경 등을 이용하였다.

  • PDF

The Frequency Spectrum Characteristics of the Radiated Electromagnetic Waves during Positive DC Discharge in Liquid Nitrogen (액체질소중 정극성 직류방전시 방사전자파의 주파수 스펙트럼 특성)

  • Park, Gwang-Seo;Sin, Ho-Yeong;Choe, Byeong-Ju;Choe, Sang-Tae;Kim, Gi-Chae;Lee, Gwang-Sik;Lee, Dong-In
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.648-655
    • /
    • 1999
  • In this study, a relationship between DC discharge and the radiated electromagnetic waves is investigated by measuring electromagnetic waves using a biconical antenna and a spectrum analyzer. The characteristics of frequency spectrum ofthe radiated electromagnetic waves was measured at the atmospheric pressure in Liquid Nitrogen $(LN_2)$ during partial discharges in nonuniform and uniform electric field depend on positive DC power. From this experiment results, it was confirmed that when partial discharge was produced in Liquid Nitrogen and Air, the signal of partial discharge was detected by this experiment and the analysis method. It is considered thatthese results obtained from this investigation may be used as fundamental data for diagnosis and prediction of insulation on the equipments ultra-high voltage, superconducting and cryogenic applications.

  • PDF

A Study on the Electrical Properties of Electrical Tree Degradation in XLPE Cable Insulation (XLPE 케이블의 전기트리 열화에 따른 전기적 특성 검토)

  • Gang, Dong-Sik;Seon, Jong-Ho;Lee, Hong-Sik;Park, Jeong-Hu;Jo, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.400-405
    • /
    • 2000
  • In order to improve the reliability of XLPE cables, it is necessary to understand the mechanism of electrical and water tree degradation. Especially, electrical tree initiation and propagation are important in XLPE cable insulation. This paper deals with the changes of electrical properties of XLPE cable insulation with electrical tree degradation. To understand the electrical properties of XLPE insulation, specimens were prepared by 22.9kV distribution cable and made in a type of block. Ogura needles having tip radius of 10${\mu}{\textrm}{m}$ were inserted into each block pieces. AC voltages of 8kV, 10kV and 12kV at 60Hz were applied to needle. We investigated the relationship between electrical properties(PD quantity, tan$\delta$ and DC current) and the growth of electrical tree. The electrical properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed.

  • PDF

Surface Discharge Characteristics of a DC Corona Charged Ferroelectric Pellet Barrier (직류 코로나 하전된 강유전체구 층의 연면방전특성)

  • Geum, Sang-Taek;Lee, Geun-Taek;Mun, Jae-Deok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.385-390
    • /
    • 1999
  • Surface corona discharge characteristics of a dc corona charged ferroelectric pellet barrier have been investigated experimentally. Electric charges stored on the surfaces of the ferroelectric pellets by a dc corona discharge provide partial electric fields on the surfaces of the ferroelectric pellets, which could generate surface corona discharges on the ferroelectric pellets. This system utilizes both the surface discharges on the ferroelectric pellet barrier and the corona discharge between corona tip and mesh electrode. Positive and negative dc voltages were applied to the tip to generate partial discharges, and corona currents were estimated to investigate the buildup charge on ferroelectric pellets as a function of the applied time and the charge relaxation time constants of ferroelectric pellets. As a result, in the case of the negative corona discharge with the ferroelectric pellet barrier, the mean corona current and ozone generation increase greatly, and the surface discharges on the ferroelectric pellets can be fenerated efficiently. It is also found that, charge relaxation time, dielectric constants offerroelectric pellets, polarity of applied voltage and applied time affected to the surface discharges among the ferroelectric pellets.

  • PDF