• Title/Summary/Keyword: 직류/직류

Search Result 2,505, Processing Time 0.035 seconds

High-Order Temporal Moving Average Filter Using Actively-Weighted Charge Sampling (능동-가중치 전하 샘플링을 이용한 고차 시간상 이동평균 필터)

  • Shin, Soo-Hwan;Cho, Yong-Ho;Jo, Sung-Hun;Yoo, Hyung-Joun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.2
    • /
    • pp.47-55
    • /
    • 2012
  • A discrete-time(DT) filter with high-order temporal moving average(TMA) using actively-weighted charge sampling is proposed in this paper. To obtain different weight of sampled charge, the variable transconductance OTA is used prior to charge sampler, and the ratio of charge can be effectively weighted by switching the control transistors in the OTA. As a result, high-order TMA operation can be possible by actively-weighted charge sampling. In addition, the transconductance generated by the OTA is relatively accurate and stable by using the size ratio of the control transistors. The high-order TMA filter has small size, increased voltage gain, and low parasitic effects due to the small amount of switches and sampling capacitors. It is implemented in the TSMC $0.18-{\mu}m$ CMOS process by TMA-$2^2$. The simulated voltage gain is about 16.7 dB, and P1dB and IIP3 are -32.5 dBm and -23.7 dBm, respectively. DC current consumption is about 9.7 mA.

A Study on the Function Improvement of the Serge Protection Device for Radar Control Unit (레이더장비에 적용되는 저압전력계통의 서지보호장치 기능개선에 관한 연구)

  • Jo, Hee-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.400-407
    • /
    • 2016
  • The purpose of this study is to propose a useful method of solving the problem of thermal stability in surge protection devices (SPDs). First of all, the existence of the problem in the developed SPDs was confirmed by experiment. After analyzing the problem, a useful method of solving it is proposed and implemented. An experiment is performed to verify the performance of the implemented device. The results of this study are as follows; it is revealed that the problem of the thermal stability results from the varistor, one of the components in the SPD. A varistor with a built-in thermal fuse is applied to the SPD for the purpose of solving the problem. The experimental results confirmed that the thermal stability was improved by replacing the varistor. As a result of this study, the reliability of radar control units is enhanced and the probability of malfunction is reduced.

Design and fabrication of a 300A class general-purpose current sensor (300A급 일반 산업용 전류센서의 설계 및 제작)

  • Park, Ju-Gyeong;Cha, Guee-Soo;Ku, Myung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 2016
  • Current sensors are used widely in the fields of current control, monitoring, and measuring. They have become more popular with the increasing demand for smart grids in a power network, generation of renewable energy, electric cars, and hybrid cars. Although open loop Hall effect current sensors have merits, such as low cost, small size, and weight, they have low accuracy. This paper describes the design and fabrication of a 300A open loop current sensor that has high accuracy and temperature performance. The core of the current sensor was calculated numerically and the signal conditioning circuits were designed using circuit analysis software. The characteristics of the manufactured open loop current sensor of 300 A class was measured at currents up to 300 A. According to the test of the current sensor, the accuracy error and linearity error were 0.75% and 0.19%, respectively. When the temperature compensation was carried out with the relevant circuit, the temperature coefficients were less than $0.012%/^{\circ}C$ at temperatures between $-25^{\circ}C$ and $85^{\circ}C$.

Characteristics of Open-Loop Current Sensor with Temperature Compensation Circuit (온도보상회로를 부착한 개방형 전류측정기의 특성)

  • Ku, Myung-Hwan;Park, Ju-Gyeong;Cha, Guee-Soo;Kim, Dong-Hui;Choi, Jong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8306-8313
    • /
    • 2015
  • Open-type current sensors have been commonly used for DC motor controller, AC variable controller and Uninterruptible Power Supply. Recently they have begun to be used more widely, as the growth of renewable energy and smart-grid in power system. Considering most of the open-type current sensors are imported, developing the core technology needed to produce open-type current sensors is required. This paper describes the development and test results of open-type current sensors. Design of C type magnetic core, selection and test of a Hall sensor, design of current source circuit and signal conditioning circuit are described. 100A class DIP(Dual In-line Package) type and SMD(Surface Mount Devide) type open-type current sensors was made and tested. Test results show that the developed open-type current sensor satisfies the accuracy requirement of 2% and linearity requirement of 2% at 100 A of DC and AC current of 60Hz. Temperature compensation was carried out by using a temperature compensation circuit with NTC(Negative Temperature Coefficient) thermistor and the effect of the temperature compensation are described.

Effective Concentration of Procaine Solution for Inotophoresis

  • Lee Jae-Hyoung;Kim Joo-Young;Jekal Seung-Joo
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 1998
  • The purpose of this study was to determine the of effective concentration of procaine iontophoresis for durarion of cutaneous local anesthesia. Forty-five healthy students with an age range of 19 to 34 years$(21\pm2.7)$, were participated in this study. The subjects were randomly assigned into 5 groups. Bach 9 subjects received iontophoresis on the flexor surface of dominant forearm with soft cotton pad $(3.5\times3.5cm)$ soaked in 2ml of $2\%$ (pH 5.28), $4\%$ (pH 5.12), $8\%$ (pH 4,98), $16\%$ (pH 4.72), $32\%$ (pH 4.52) procaine hydrochloride solution at 4mA for 10 minutes (total current 40mA min) using anodal direct current. The study was performed in a randomized, double-blind design, After procaine iontophoresis, the duration of anesthesia were evaluated at five minute intervals on five random locations in the iontophoretically area using a 21-gauge sterile hypodermic needle pressed with 1mm invagination unitl sharp pin-pricking pain sensation returned. The data were analyzed with one-way ANOVA to determine significant differences between groups. Duncan post hoc was performed at level .01. The relationship between anesthetic duration and procaine concentration was assessed with Pearson Product-Moment Correlation Coefficients. ANOVA tests showed significant differences in the anesthetic duration between the concentration of procaine solution (p<.001). Procaine iontophoresis with $4\%$ concentration produced cutaneous Socal anesthesia of significantly longer duration(15.56 min) than iontophoresis with $2\%,\;8\%,\;16\%$, and $32\%$ of procaine GCl(p<.01). Whereas the anesthetic duration had no correlation with concentration of procaine solution (r=-0.41, NS). These results support the $4\%$ procaine solution was an effective concentration of iontophoresis for induced cutaneous local anesthesia.

  • PDF

Development of Recycling Technology for Used Cables (폐전선 재활용 기술개발)

  • 양정일;오정완;최우진;황선국
    • Resources Recycling
    • /
    • v.3 no.2
    • /
    • pp.28-34
    • /
    • 1994
  • A part of used cables, such as electric and communication cables has already been recycled by using simple processing methods. However, it has been found that the main problems in recycling of the used cables are insufficient treatment of fine stranded wires and low recovery of copper by air separation process. It has been shown that copper can be effectively separated from the PE using a solvent treatment method. In the present study, the used communication wires having diameter of 0.4 mm are treated in the mixing solution of toluene and water at $86^{\circ}C$ for about 10 minutes. In the solvent treatment, the copper wires recovered have 10~15mm length, which are much longer than that of 1~2mm length copper wires recovered by air table concentration method used in current recycling plants. The process consisting of cutting, air separation and electrostatic separation would be recommendable for the treatment of mixed cables. In this investigation, fine copper powders can also efficiently be recovered from insulation materials using electrostatic separator at the conditions of 20~50RPM roller speed and 15~30KV high DC power.

  • PDF

The Effect of Residual H2Pressure on Gallium-doped ZnO Films Deposited by Magnetron Sputtering (마그네트론 스퍼터링에 의해 제작한 Gallium-doped ZnO 박막에 있어서 잔류 H2O 분압의 영향)

  • Song, Pung-Keun;Kwon, Young-Jun;Cha, Jae-Min;Lee, Byung-Chul;Ryu, Bong-Ki;Kim, Kwang-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.10
    • /
    • pp.928-934
    • /
    • 2002
  • Gallium doped Zinc Oxide(GZO) films were deposited by dc magnetron sputtering using a GZO ceramic target at various conditions such as substrate temperature (RT, 400), residual water pressure ($P_{H_2O}$; 1.61${\times}10^{-4}∼2.2{\times}10^{-3}$ Pa), introduction of $H_2$ gas (8.5%) and different magnetic field strengths(250, 1000G). GZO films deposited without substrate heating showed clear degradation in film crystallinity and electrical properties with increasing $P_{H_2O}$. The resistivity increased from 3.0${\times}10^{-3}$ to 3.1${\times}10^{-2}{\Omega}㎝$ and the grain size of the films decreased from 24 to 3 nm when PH2O was increased from 1.61${\times}10^{-4}$ to 2.2${\times}10^{-3}$ Pa. However, degradation in electrical properties with increasing $P_{H_2O}$ was not observed for the films deposited with introduction of 8.5% $H_2$. When magnetic field strength of the cathode increased from 250G to 1000G, crystallinity and electrical properties of GZO films improved remarkably about all the $P_{H_2O}$. This result could be attributed to the decrease in film damage caused by the decrease in plasma impedance.

Electrical Properties of Sputtered Gallium-doped Zinc Oxide Films Deposited Using Ne, Ar, or Kr Gas (Ne, Ar, Kr 가스를 사용하여 제작한 스퍼터 Gallium 도프 ZnO 박막의 전기적 특성)

  • Song, Pung-Keun;Ryu, Bong-Ki;Kim, Kwang-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.10
    • /
    • pp.935-942
    • /
    • 2002
  • Gallium-doped ZnO (GZO) films were deposited on soda-lime glass substrate without heating using Ne, Ar, or Kr gas. Electrical properties of GZO films deposited at various total gas pressures were investigated for the film positions corresponding to the erosion region (region B) and outside the erosion region (region A) of the target. Region B showed high resistivity, which was attributed to the decrease in carrier density and Hall mobility, compared to region A. GZO films deposited using Ne gas showed the degradation in resistivity and crystallinity, whereas, GZO films deposited using Kr gas showed the improvement in resistivity and crystallinity. This degradation in film properties could be attributed to the film damage caused by the bombardment of high-energy particles. Especially, the energies of recoiled neutral atoms ($Ne^0,\;Ar^0,\;Kr^0$) calculated by Monte Carlo simulation corresponded to experimental results.

The effects of electrical current from a micro-electrical device on tooth movement (초소형 전기장치에 의한 미세 전류가 치아이동에 미치는 효과)

  • Kim, Dong-Hwan;Park, Young-Guk;Kang, Seung-Gu
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.337-346
    • /
    • 2008
  • Objective: The purpose of this study was to determine whether an exogenous electric current to the alveolar bone surrounding a tooth being orthodontically treated can enhance tooth movement in human and to verify the effect of electric currents on tooth movement in a clinical aspect. Methods: This study was performed on 7 female orthodontic patients. The electric appliance was set in the maxilla to provide a direct electric current of $20{\mu}A$. The maxillary canine on one side was assigned as the experimental side, and the other as control. The experimental canine was provided with orthodontic force and electric current. The control side was given orthodontic force only. Electrical current was applied to experimental canines for 5 hours a day. The amount of canine movement was measured with an electronic caliper every week. Results: The amount of orthodontic tooth movement in the experimental side during 4 weeks was greater by 30% compared to that of the control side. The amount of increase in tooth movement in the experimental side was statistically significant. The amount of tooth movement in the experimental side during the first two weeks was !Bleater than that in the following two weeks. The amount of weekly tooth movement in the control side was decreased gradually. Conclusions: These results suggested that the exogenous electric current from the miniature electric device might accelerate orthodontic tooth movement by one third and have the potential to reduce orthodontic treatment duration.

Design and Experiment of Ku_band Linear Active Phased Array Antenna System (Ku 대역 선형 능동 위상 배열 안테나 시스템 설계 및 실험)

  • Ryu Sung-Wook;Eom Soon-Young;Yun Jae-Hoon;Jeon Soon-Ick;Kim Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.7 s.110
    • /
    • pp.694-705
    • /
    • 2006
  • In this paper, the linear active phased array antenna system operated in Ku DBS band was designed and experimented. The antenna system was composed of sixteen radiating active channels and Wilkinson power combiners with 16-channel inputs, a stabilizing DC bias and phase control board. Electrical beams of the antenna system can be formed by controling the phase-states of 3-bit digital phase shifter inside each active channel by virtue of the phase control board. The amplitude and phase deviations measured between active channels were less than ${\pm}0.8dB$ and ${\pm}15^{\circ}$, respectively, and the noise figure of each active channel was measured less than 1.2 dB in the operating band. The measured performances of the overall antenna system showed the antenna gain of more than 23.07 dBi and the sidelobe level of less than -11.17 dBc, and the bore-sight cross-polarization level of less than -12.75 dBc in the operating band. Also, by phase-controlling active channels, the beam scan patterns at $10^{\circ},\;20^{\circ},\;30^{\circ}$ were measured, and the losses caused by the corresponding beam scanning were 1.1 dB, 2.5 dB and 3.6 dB from the measurements, respectively.