• Title/Summary/Keyword: 지향성 장비

Search Result 26, Processing Time 0.022 seconds

Input Signal Model Analysis for Adaptive Beamformer (적응 빔형성기의 입력신호 모델 분석)

  • Mun, Ji-Youn;Hwang, Suk-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.3
    • /
    • pp.433-438
    • /
    • 2017
  • Containing an Angle-of-Arrival(: AOA) estimation and interference suppression techniques, an adaptive beamformer is one of core techniques for the Signal Intelligence(: SIGINT) which collect various intelligence utilizing cutting edge devices including the radar and satellite. It generates a beam with the directivity in a corresponding direction, to efficiently receive a signal from the specific direction, using antenna array. In this paper, we present the received signal model including interference signals and noise, which can be applied to an input of the signal intelligence satellite system equipped with the AOA estimation and the interference cancellation techniques, and analysis the characteristics of various signals, which can be included in the proposed received signal model. This proposed signal model can be directly applied to the performance evaluation for a variety of beamforming techniques. Also, we verify the spectrum characteristic of the presented received signal model in the frequency domain through computer simulation examples.

A Development of the DIRCM Effectiveness Analysis Simulator based on DEVS (DEVS 기반 DIRCM 효과도 분석 시뮬레이터 개발)

  • Shin, Baek-Cheon;Hur, Jang-Wook;Kim, Tag-Gon;Kim, Mi-Jeong
    • Journal of the Korea Society for Simulation
    • /
    • v.27 no.2
    • /
    • pp.115-123
    • /
    • 2018
  • we analyzed simulation of the effectiveness for one or two DIRCM on a helicopter. The survival rate of helicopter followed increase of the deception rate of DIRCM. When the deception rate was over 70% at 100% detection rate, the survival rate was 10~30% when one DIRCM was installed and the survival rate was 70~80% when two DIRCMs were installed. When the detection rate was over 70% at 100% deception rate the survival rate was 10~30% case of one DIRCM was installed. survival rate was 20~30% when two were installed. Survival rate of 70~90% was observed with one DIRCM when the deception rate and detection rate were 100%, and 100% with two DIRCMs.

Parametric Array Sonar System Based on Maximum Likelihood Detection (최대우도 검파에 기반한 파라메트릭 어레이 소나 시스템)

  • Han, Jeong-Hee;Lee, Chong-Hyun;Paeng, Dong-Guk;Bae, Jin-Ho;Kim, Won-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • In the underwater communications, transmitted acoustic signal is corrupted by interference from multipath. A parametric array transducer is capable of radiating a narrow beam with very low sidelobe levels. In certain cases, the parametric array transducer can help the multipath problem. To improve the performance of the underwater communications, the statistical signal processing methods will be required. In the paper, the communication system using a parametric array transducer was demonstrated. To detect the received signal of the communication system based on the on-off keying, the maximum likelihood method using averaged signal for a particular window size is used. The communication system has GUI using LebVIEW which allows the user to change the parameter. The GUI can also be easily modified based on the characteristics of a parametric array transducer. The implemented system can effectively evaluate the performance of the parametric array transducer.

A Design of the Dual Directional Coupler with Unequal Coupling Value (비대칭 결합도를 갖는 이중 방향성 결합기 설계)

  • Kim, Chul-Soo;Park, Jun-Seok;Ahn, Dal
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.4
    • /
    • pp.1-7
    • /
    • 1999
  • The demands for the various type of directional coupler, which is for the sampling of the signal levels in mobile communication baseband or transceiver systems, are growing. The proposed dual directional coupler, which has three parallel coupled transmission lines, can provide the dual coupling and good isolation characteristics between the coupling ports. In this paper, the novel analysis method and the design equation of even and odd mode for the dual directional coupler, which is employing the asymmetrically coupled transmission lines, are proposed. Using the proposed method, the dual directional coupler for PCS system has been designed and fabricated. We obtained the desired coupling value and the high directivity of 40dB. Measured results show the validity of this design method.

  • PDF

The Measurement System for Small Microphone's Electro Acoustic Characteristics (소형 마이크로폰의 전기적인 음향 특성 측정 시스템)

  • Park, Byoung-Uk;Kim, Hack-Yoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.3
    • /
    • pp.259-266
    • /
    • 2007
  • The parameters of electric acoustic characteristic used as standards to evaluate the performance of a small microphone are composed of sensitivity, harmonic distortion, frequency response, directivity and others. Such characteristic parameters should be designed differently depending on a purpose, so it is important to verify whether a small microphone was made appropriately for the purpose after measuring the acoustic characteristics. Therefore, a system that can measure the acoustic characteristic parameters of a small microphone using DSP, not only simultaneously but also in real-time, was implemented in this paper. To verify the implemented system, four kinds of microphones were measured and the results were compared with the data values of the acoustic characteristics of each microphone. There were a little discrepancy between them because the conditions when measuring the characteristics were not identical. But it was verified that the errors are within the error tolerance and it proved that the system can be used in place of the conventional equipment used in measuring the acoustic characteristics of small microphones.

  • PDF

A comparison of acoustic measures among the microphone types for smartphone recordings in normal adults (정상 성인에서 스마트폰 녹음을 위한 마이크 유형 간 음향학적 측정치 비교)

  • Jeong In Park;Seung Jin Lee
    • Phonetics and Speech Sciences
    • /
    • v.16 no.2
    • /
    • pp.49-58
    • /
    • 2024
  • This study aimed to compare the acoustic measurements of speech samples recorded from individuals with normal voices using various devices: the Computerized Speech Lab (CSL), a unidirectional wired pin-microphone (WIRED) suitable for smartphones, the built-in omnidirectional microphone (SMART) of smartphones, and Bluetooth-connected wireless earphones, specifically the Galaxy Buds2 Pro (WIRELESS). This study included 40 normal adults (12 males and 28 females) who had not visited an otolaryngologist for respiratory diseases within the past three months. Participants performed sustained vowel /a/ phonation for four seconds and reading tasks with sentences ("Walk") and paragraphs ("Autumn") in a sound-treated booth. Recordings were simultaneously conducted using the four different devices and synchronized based on the CSL-recorded samples for analysis using the MDVP, ADSV, and VOXplot programs. Compared with CSL, the Cepstral Spectral Index of Dysphonia (CSIDV, CSIDS) and Acoustic Voice Quality Index (AVQI) values were lower in the WIRED and higher in the SMART. The opposite trend was observed for the L/H spectral ratios (SRV and SRS), and the WIRELESS demonstrated task-specific discrepancies. Furthermore, both the fundamental frequency (F0) and the cepstral peak prominence of the vowel samples (CPPV) had intraclass correlation coefficient (ICC) values above 0.9, indicating high reliability. These variables, F0 and CPPV were considered highly reliable for voice recordings across different microphone types. However, caution should be exercised when analyzing and interpreting variables such as the SR, CSID, and AVQI, which may be influenced by the type of microphone used.