• Title/Summary/Keyword: 지하 주차장

Search Result 211, Processing Time 0.024 seconds

The First Step Study on the Standardization of the Analysis and Design for Underground BOX-Type Structures (BOX형 지하구조물 해석 및 설계 표준화 연구(1차 연구))

  • Han, Man-Yeop;Park, Hong-Kee;Son, Eun-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.883-886
    • /
    • 2008
  • KCI Committee 107 is "Underground Structures Research Committee". The Committee 107completed the first step study on the analysis and design for underground BOX type structures by 2005. In the study, the committee attempted to the standardization of the analysis and design procedure. This is the introduction and summary of the study and the prospective plan on this subject.

  • PDF

Economic Evaluation of Underground Parking Lot PC Structural System that is Suitable for Long-Life Housing (장수명주택에 적합한 지하주차장 PC구조시스템의 경제성분석에 관한 연구)

  • Jo, Min-Joo;Kim, Jong-Sung
    • Journal of the Korean housing association
    • /
    • v.26 no.2
    • /
    • pp.103-110
    • /
    • 2015
  • Precast Concrete (PC) construction method can be the one that is suitable for long-life housing due to its merit in respect of maintenance and durability based on crack-free from mass production with indirect construction cost-saving-effect due to shortening construction period comparing to the conventional construction method, but it has the problem that causes the raise of direction construction costs. So, this study analyzed its economic feasibility of PC method whose maintenance and durability are excellent for underground parking lot of apartment house for accomplishing cost-saving long-life housing by applying the various structural system. In evaluation of unit module structural system, two-way PC system requires 10 to 28% more costs for frame work than RC rigid frames, and, one-way PC system 98~112%. Although it varies depending on the method, the costs are similar to RC rigid frame structure, provided a proper method is adopted. Also, Model 11, which was most economical in the evaluation, was applied to an real parking lot and about 2 to 6% of construction costs was reduced than RC rigid frames. This seems to be because, although PC system has a higher production cost, introduction of P.S (prestress) reduces member depth and, therefore, height, as well as the number of members per unit module.

Structural Analysis of Underground Parking Garage Under Vehicle Load (지하주차장 차량하중에 따른 구조체의 영향분석)

  • Kim, Young-Jin;Lee, Bum-Sick;Choi, Dong-Sub;Oh, Hyo-Keon;Kang, Chang-Bum
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.4
    • /
    • pp.22-29
    • /
    • 2013
  • Accumulation of more than 20,000,000 vehicles since the establishment of the quality of life and economic development needs several parking lots and cause crack problem in Korea. Related structures in large cities due to the lack of parking garage attached to secure underground parking structures are actively being built, and the basement parking lot will continue to increase more stories and the trend is expected to be larger. But so far, construction of the underground parking structure is related to a number of problems, including cracks in the structure. Therefore, in this study, repair, reinforcement and a few non-economic losses in the current design criteria are presented. The review of the structure used to current design criteria is to minimize crack and maximize usability.

A Study on Inhabitants' Mental Survey for Apartment House's Underground Parking Lots (공동주택 지하주차장 계획을 위한 거주자 의식조사연구)

  • Jeong, Young-Suk;Cho, Sung-Woo;Oh, Se-Gyu
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.113-117
    • /
    • 2009
  • By statistics in August, 2007, currently Korean motors registration number broke through 16 million units. The demand of motors is being increased as time goes on and the demand of parking lot within apartment complex is increased together. Therefore, it is inevitable to expand underground parking lots. Underground parking lots have relatively weaker environment than the ground and physical/psychological problems as distance far away from the main building, fear for vehicle damage and crimes, impure air, darkness and closed feeling take place. Underground parking lots also occupy a lot of area ratio within apartment complex and have a lot of effects on other facilities. Therefore, underground parking lots are neglected for all that underground parking lots have deep relations with satisfaction for public space within apartment complex. Accordingly, the purpose of the study is to make reference materials when underground parking lots are planned by grasping satisfaction of underground parking lots through inhabitants'mental survey and surveying preferential location and requirements of parking lots.

  • PDF

Performance Assessment of Light Pipe System for the Advanced Luminous Environment of the Underground Parking Lot (지하주차장 빛환경 개선을 위한 광파이프 시스템의 채광성능 평가에 관한 연구)

  • Shin, Ju-Young;Hwang, Tae-Yon;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.25-33
    • /
    • 2010
  • Use of daylight in underground space interacts with physiological need for human beings and provides relief from feeling secluded. Light pipe system can deliver natural light into the space where it is needed and can be used as primary or a secondary light source with benefits of energy, productivity and health. To use light pipe system effectively under various conditions, it is important to investigate the effectiveness of light pipe system with reliable monitoring protocol. This paper presents the results of light pipe system performance used in underground parking lot under different sky conditions. Comparisons were made between the illuminance standards of underground parking lot and the monitored data. The results indicated that adequate illuminance level was shown until 4.5m distance from the light pipe under clear sky condition. However, additional lighting device showed be used under overcast sky to meet the proper illuminance level.

분배계통에 따른 지하주차장 환기설비 성능의 예측

  • 김경환;이재헌;오명도;김종필
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.982-992
    • /
    • 2001
  • In this paper, the performance of ventilation equipments in enclosed parking garages were investigated for several air distribution systems by numerical method. Air change effectiveness of the non-mixing system was 0.42. It meant that more supply air as much as the design supply air was needed to maintain good indoor air quality. In the high speed nozzle ventilating system which is most expensive one, air change effectiveness was 0.54. Therefore this system satisfied to ventilation design. In the jet fan ventilating systems, air change effectiveness for jet fan ventilating system-A with 18 jet fans and jet fan ventilating system-B with 6 jet fans in circulation mixing arrangement were 0.565 and 0.42 respectively. Jet fan ventilating system-C with 6 jet fans in transport mixing arrangement was 0.535. Jet fan ventilating system-A and jet fan ventilating system-C met the ventilation design. But velocity in jet fan ventilating system-A was over 2.0m/s which is inappropriate in human comfort. Therefore this system is not proper to ventilation. Jet fan ventilating system-C was the optimum one for enclosed parking garages among 5 systems examined in this paper.

  • PDF

A Study on the Superstructure System Analysis of Underground Parting Lot in Apartment. (공동주택 지하주차장 상부구조 형식 분석연구)

  • Lim, Nam-Gi;Song, Hee-Won;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.2
    • /
    • pp.149-156
    • /
    • 2003
  • The purpose of this study was to find out the most reasonable design in the superstructure of an underground parking lot which needs to be considered with the economic efficiency being influenced on the subdivision price, construction duration, workability and the maintenance of crack and leakage status of apartment house. In this research, we've evaluated the fitness for the superstructure of an underground parking lot by examination of construction constraint, which was based on the calculated data of structural design and quantity survey. The results of this study are summarized as follows. 1. The system of the absent structure of beam is proper structure for economic efficiency, construction duration and workability, but it is disadvantageous at the side of maintenance efficiency because of the many part of large slab. In the opposite direction, the establishing structure of beam has the advantages of structural stability except economic efficiency, construction duration and workability 2. It's required a proper selection for the views being contrary to each other which the owners considers good quality, on the other hand, the contractors consider construction duration and workability. 3. In making a selection for the superstructure of an underground parking lot, we have concluded that it is the most important to choose the proper structure for the demanded performance by contrasting with two system. (2Bay or 3Bay)

Concrete Specification and Mixing Design for the Reduction of Slab Defects in Underground Parking Lot (지하주차장 슬래브 하자 저감을 위한 콘크리트 규격 및 배합설계)

  • Kim, Han-Sic;Ha, Jung-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.235-236
    • /
    • 2023
  • Concrete surfaces have weak surface strength due to bleeding and laitance, and problems such as peeling, cracking, and cracking may occur. In particular, underground parking lots can be said to be more vulnerable to peeling, breaking, and cracking if excessive loading of materials and equipment movement are not managed at the initial age after placing of concrete. Cracks, peeling, and cracking problems in slab concrete in underground parking lots of apartments can lead to leakage problems and affect finishing materials constructed on top of topping concrete, reducing the performance required for waterproof materials. Therefore, in this study, the bleeding and surface strength according to the standard of topping concrete and the use of admixture were reviewed to solve the crack, peeling, and cracking problems among the types of defects in underground parking lot slab concrete. As a result, it was derived that the optimal concrete compressive strength is 30MPa or more, and it is a reasonable performance design method to prohibit the substitution of admixtures.

  • PDF