• Title/Summary/Keyword: 지하 주차장

Search Result 211, Processing Time 0.03 seconds

The Characteristics of Indoor Air Quality Variation in Underground Parking Lots of Apartments located in Northern Gyeonggi Province (경기도 북부지역 아파트의 지하주차장 실내공기질 변동 특성)

  • Park, Hyun-Ku;Jung, Yeon-Hoon;Kim, Byeong-Lok;Kim, Jin-gil;Shin, Hyung-Soon;Lee, Sang-Soo;Oh, Jo-Kyo
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.250-258
    • /
    • 2018
  • Objectives: The study examined indoor air quality during daytime and commute times in underground parking lots in five apartments located in northern Gyeonggi province. Methods: This study examined the temporal characteristics of $PM_{10}$, $CO_2$, CO, HCHO and VOCs in the indoor air quality of the underground parking lots in five apartments. Results: $PM_{10}$ concentration in daytime were ranged from 37.4 to $69.9{\mu}g/m^3$ which complied with the indoor air quality maintenance standard ($200{\mu}g/m^3$) and Gyeonggi province ordinance standard ($180{\mu}g/m^3$). However $PM_{10}$ concentrations in commuting time were in range of $447.3{\sim}944.0{\mu}g/m^3$ that exceeded for both criteria. The $CO_2$, CO and HCHO concentrations complied with the standard. The VOCs indicated high tendency in the order of toluene, xylene, ethylbenzene and benzene. This tendency was more apparent in commuting time than daytime. Conclusion: All indoor parking lots of five apartments were equipped with ventilators. However the most apartment residents did not operate blowers to save electricity and the lack of interest for indoor air quality. In order to improve the indoor air quality of underground parking lots in apartment, operating ventilation system during commuting time is recommended.

Punching Shear Strength of CFT Column to RC Flat Plate Connections Reinforced with Shearhead (전단머리 보강 CFT기둥-RC 무량판 접합부의 펀칭전단강도)

  • Kim, Jin-Won;Lee, Cheol-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.423-433
    • /
    • 2012
  • This paper summarizes full-scale gravity-load test results on CFT column-to-RC flat plate connections reinforced with shearhead. CFT construction has many structural and constructional advantages over conventional steel and RC column construction and is gaining wide acceptance. Meanwhile the use of RC flat plate system in the basement and residential floors of tall buildings is often mandatory to reduce story height and enable rapid construction in domestic practice. Combining CFT column and flat plate floor is expected to result in further rapid construction. However, the issues related to connecting CFT column to RC flat plate have not been fully addressed yet. Several promising connecting schemes by using steel shearhead were proposed and tested in this study. Test results showed that the proposed connection can exhibit the punching shear strength higher than RC flat plate counterparts. An empirical formula that can reasonably predicts the punching shear strength of the proposed connection was also proposed.

Shear Strength of Prestressed PC-CIP Composite Beams without Vertical Shear Reinforcements (수직전단보강이 없는 PS 콘크리트와 현장타설 콘크리트 합성보의 전단강도)

  • Kim, Chul-Goo;Park, Hong-Gun;Hong, Geon-Ho;Kang, Su-Min;Suh, Jung-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.533-543
    • /
    • 2014
  • Currently, composite construction of prestressed Precast Concrete (PC) and Cast-In-Place (CIP) concrete with different concrete strengths are frequently used in the modular construction. However, current design codes do not clearly define shear design methods for such composite beams. In this present study, simply supported prestressed PC-CIP composite beams without vertical shear reinforcement or only with horizontal shear reinforcement were tested to evaluate the effect of prestressing on the shear strength and the shear design method for such composite members. The test variables were the area ratio of PC and CIP concretes, prestressing force, shear span-to-depth ratio, and shear reinforcement ratio. The results showed that the shear strength was increased by the increase of prestressing force and prestressed PC area, and the decrease of shear span-to-depth ratio.

Punching Shear Strength and Behavior of CFT Column to RC Flat Plate connections (CFT기둥-RC 무량판 접합부의 펀칭전단강도 및 거동)

  • Lee, Cheol Ho;Kim, Jin Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.4
    • /
    • pp.491-502
    • /
    • 2006
  • This paper summarizes full-scale test results on CFT column-to- flat plate connections has gained wide acceptance subjected to gravity loading. CFT construction has gained wide acceptance in a relatively short time in domestic building construction practice due to its various structural and construction advantages. However, efficient details for CFT column to flat plate connections have not been proposed yet. Based on the strategies that maximize economical field construction, several connecting schemes were proposed and tested. Test results showed strength and connection stiffness exceeding those of R/C flat p late counterparts. A semi-analytical procedure is presented to model the behavior of CFT column-to-flat plate connections. The five parameters to model elastic to post-punching catenary action range are calibrated based on the limited test data of t to progressive collapse prevention design is also illustrated.

Physical Properties of Concrete Using Shrinkage Reducing Admixture and Expansive Additive (수축저감제와 팽창재를 혼입한 콘크리트의 물리적 특성)

  • Jung, Yang-Hee;Song, Young-Chan;Kim, Yong-Ro;Han, Hyung-Sub;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.919-922
    • /
    • 2008
  • This paper reports the physical and shrinkage properties of concrete using expansive additive(E) and three shrinkage reducing admixtures(SRA1, 2, 3) in order to reduce shrinkage of concrete. For the properties of fresh concrete, the use of SRA1, 2, 3 results in a increase in fluidity and decrease in the dosage of super plasticizer as much as 0.05$\sim$0.1%. And For the properties of hardened concrete, the use of SRA1, 2, 3 results in a decrease in compressive, tensile and flexural strength slightly. For drying shrinkage properties, the use of SRA3 is the most effective for reduction of shrinkage, and the next best way to reduce shrinkage is combination with expansive additive(E) and shrinkage reducing admixture(SRA) or the using of expansive additive(E).

  • PDF

A Study on the Location Awareness System Using TOA(Time of Arrival) of CSS(Chirp Spread Spectrum) Algorithm (CSS 기반의 TOA 알고리즘을 이용한 위치인식 시스템 구현에 관한 연구)

  • Kim, Jung-Soo;Yang, Jin-Uk;Yang, Sung-Hyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.2
    • /
    • pp.13-25
    • /
    • 2008
  • In this paper, we propose the Location Awareness System adjusting Ranging Technology for CSS(Chirp Spread Spectrum) which is adopted on 2.45GHz standard in IEEE 802.15.4a and TOA(Time-of-Arrival) algorithm. The conventional methods have adopted RSSI, ultrasonic waves and infrared rays in Zigbee. RSSI measures strength indication of received signal and recognizes the position of nodes in RF boundary. However, this technology has the following problems; lots of error by the change of the channel environment and much power consumption. In this paper, adopting chirp pulse on 2.45GHz standard in IEEE 802.15.4a and SDS-TWR(Symmetrical Double Side-Two Way Ranging) method using the characteristic of Spread Spectrum, a new Location Awareness System is suggested. The distance and the coordinate are measured within ${\pm}\;5cm$ by TOA(Time of Arrival) algorithm and proposed algorithm and the data in error rate is decreased less than 1%. Through these results, the algorithm suggested in this paper is verified for its performance in a computer simulation.

  • PDF

Weighing the CS Experts' Priority on the Quality of Each Housing Segment - Focused on Apartment Building Construction Projects - (공동주택 부위별 마감수준에 대한 CS전문가 집단의 인식 분석)

  • Cho, Tae-Jea;Choi, Jong-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.6
    • /
    • pp.609-617
    • /
    • 2011
  • For the past several decades, the residential housing market has been led by construction firms rather than consumers; in essence, it has been a suppliers' market. However, the market is experiencing a transition to a buyers' market, the implication of which is that there will be increased competition among the residential building suppliers. For this reason, it is necessary for construction firms to prepare new strategies to respond to the rapidly changing market environment. Furthermore, consumer satisfaction should be valued more highly than in the past, and should be a baseline in formulating construction product development strategy. For the pre-classified 13 apartment building segments, questionnaire surveys are conducted for the 50 CS (Customer Satisfaction) experts to evaluate their perceptions on the weighing of the quality of each apartment segment. Data obtained from a survey of experts was analyzed from an industry perspective utilizing the AHP technique. Analysis results indicate that the CS experts valued the kitchen & dining area more highly than all other segments. Specific analysis results and implications drawn from the study can be a valuable basis for marketing, product development, and quality management.

A Study on Improvement of Connection Method of Underground Parking Lot SP Equipment Water Supply Pipe for Effective Fire Activities (효과적인 소방활동을 위한 지하주차장 스프링클러설비 송수배관 연결방식의 개선에 관한 연구)

  • Son, Gae-Seong;Choi, Ji-Hun;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.161-169
    • /
    • 2015
  • A fire sprinkler system is very important to extinguish fire in the building. The sprinkler system initiates sprinkler discharge if the detection system identifies a developing fire and opens the pre-action valve. However, pre-action fire sprinkler systems mainly installed in the underground parking lot at the apartment complex do not properly operate at fire if the connection type of fire sprinkler systems does not properly installed and operated. This study identified the relationship between fire dispersion & damage and the connection type of water supply in the sprinkler system from many fire cases at the apartment complex in South Korea. In addition, this study also identified the water supply differences and characteristics between South Korea and foreign countries. The main purpose of this study is also to improve the water connection types in the sprinkler system that can reduce the potential failures of pre-action valve operation through electrical signal system. The study also suggests the improvement plan for water connection types in pre-action fire sprinkler system that can minimize potential failure of pre-action fire sprinkler system. The suggestions for revising the fire safe standard in South Korea includes letting the water supply pipe of sprinkler system water inlet connect to the second side of pre-action valve and the water flow device that can minimize potential failure of sprinkler system.

Quantitative Evaluation on Surveillance Performance of CCTV Systems Based on Camera Modeling and 3D Spatial Analysis (카메라 모델링과 3차원 공간 분석에 기반한 CCTV 시스템 감시 성능의 정량적 평가)

  • Choi, Kyoungah;Lee, Impyeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • As CCTVs are widely utilized in diverse fields, many researchers have continuously studied to improve the surveillance performances of a CCTV system. However, an quantitative evaluation approach about the surveillance performance has rarely been researched. Therefore, we set up the research for suggesting a quantitative evaluation approach to determine the effectiveness of CCTV coverages. We firstly defined the surveillance resolution as that varies according to object's positions and orientations. Based on the definition, we computed surveillance resolution values at all three-dimensional positions with the orientations of interests in the specified space. By comparing these values to the required reasonable resolution, we determined the surveillance performance index indicating how well a CCTV system monitor a target space for specific surveillance objectives. This proposed approach evaluates the surveillance performance of a CCTV system quantitatively, so as examines the CCTV system design before its installation based on precise 3D spatial analysis.

An Experimental Study for Development of Details and Design Method of CFT Column-to-RC Flat Plate Connections (콘크리트 충전각형강관 (CFT)기둥과 철근콘크리트 무량판 접합부 상세 및 설계법 개발을 위한 실험연구)

  • Lee, Cheol Ho;Kim, Jin Won;Oh, Jeong Gun
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.481-490
    • /
    • 2005
  • This paper summarizes the full-scale test results on the CFT column-to-flat plate connections subjected to gravity loading. CFT construction has gained wide acceptance in a relatively short time in domestic building construction practice due to its various structural and construction advantages. Constructing an underground parking floor as a flat plate system is often regarded as essential for both cost savings and rapid construction. Efficient details for CFT-column-to-flat-plate connections have not been proposed yet, however, and their development is urgently needed. Based on some strategies that maximize economical field construction, several connecting schemes were proposed and tested based on a full-scale model. The test results showed that the proposed connection details can exhibit punching shear strength and connection stiffness comparable to or greater than those of their R/C flat plate counterpart.