• Title/Summary/Keyword: 지하저장

Search Result 412, Processing Time 0.029 seconds

A Study on the Thermal Crack Control of the In-Ground LNG Storage Tank as Super Massive Structures (지하식 LNG 저장탱크 구조물의 온도균열 제어에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.773-780
    • /
    • 2011
  • In this study, thermal stress analysis are carried out considering material properties, curing condition, ambient temperature, and casting date of the mass concrete placed in bottom slab and side wall of the in-ground type LNG tank as a super massive structure. Also, based on the numerical results, cracking possibility is predicted and counter measures to prevent the cracking are proposed. For the tasks, two optimum mix proportions were selected. From the results of the thermal stress analysis, the through crack index of 1.2 was satisfied for separately caste concrete lots except for the bottom slab caste in 2 separate sequences. For the double caste bottom slab, it is necessary introduce counter measures such as pre-cooling prior to the site construction. Also, another crack preventive measure is to lower the initial casting temperature by $25^{\circ}C$ or less to satisfy 1.2 through crack index criterion. In the $1^{st}$ and $2^{nd}$ caste bottom slab, the surface crack index was over 1.2. Therefore, the surface cracks can be controlled by implementing the curing conditions proposed in this study. Since the side wall's surface crack index was over 1.0, it is safe to assume that the counter preventive measures can control width and number of cracks.

Determination of Hydraulic Parameters in Unconfined Sandy Aquifer in a Laboratory Scale (실내 자유면 사질 대수층의 수리상수 결정)

  • 김정석;김동주
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.152-157
    • /
    • 1999
  • Oil leaked from underwound storage tanks and leachate from sanitary landfills have been known as contaminant sources of the high-quality groundwater resources. The mobility of contaminants in the aquifer largely depends on the groundwater flow and the determination of associated hydraulic parameters is essential for a proper remediation of contaminated grnundwater. This study aimed at determining an optimum set of hydraulic parameters for an unconfined sandy aquifer of a laboratory scale through comparison of various methods. Results showed that the specific yield obtained from gravity drainage experiment was an average of 0.20 with minor variations in aquifer depths. and the permeabilities obtained from Dupuit approximation and slug test gave similar values of 5.33 cm/min and 5.85 cm/min but the constant head method gave 0.17 cm/min, which is much ion than the other methods. This experimental evidence reveals that the permeability of the unconfined sandy aquifer could be accurately determined by Dupuit assumption or slug tut rather than by constant head method conducted for a disturbed separate soil column.

  • PDF

Feature and Operation on Correlation for Royal (State operation) Storage of Baekjae (백제 왕실(국영) 창고시설의 특징과 운영)

  • So, Jae Yun
    • Korean Journal of Heritage: History & Science
    • /
    • v.45 no.4
    • /
    • pp.22-37
    • /
    • 2012
  • Storage facility of the pre-historic Korea is classified into the subterranean, ground and overground types. The rectangular-shaped subterranean Storage facilities have been identified in the Pungnaptoseong, the Gong mountain fortress site and the Gwanbukri site. Feature no. 196 at Gyeongdang District in Pungnaptoseong yielded a large quantity of glazed potteries, and a wooden storage at the Gwanbukri site contained a large amount of fruit seeds. These storage facilities might be functioned as the warehouse for the highest group rather than the storage for the emergency such as war and flooding and stipend of government officials. This article subdivided into "state storage" on the concept of the former that "royal storage" on the concept of the latter. If it look on the state storage at large, this include the royal storage too. But it subdivided to help article understand because Baekjae changed from state storage to royal storage by change and specialization of system after 4th. The reason why the diversification of storage pits was closely related to the unification of local polities and the concentration of political power in the state-level. Therefore, it might reflect the political circumstances the ruling elites attempted to heighten their authority in terms of the organizing tax collecting system. And divided the time of storage is confirmed separative storage pits in the suburbs of capital city. There is hight probability of top local polities or nation that have possessional a role. This is to cover on frequent war in the Three States. On the other hand, state storage is located around ancent road that linked castle gate that is divided into center and periphery depending on function and position of storage. Center is located royal storage focusing in the presumed royal palace that periphery is located state storage to provide service to the public. It is presumed that located with the government office.

Life assessment of monitoring piezoelectric sensor under high temperature at high-level nuclear waste repository (고준위방사성폐기물 처분장 고온 환경 조건에 대한 모니터링용 피에조 센서의 수명 평가)

  • Changhee Park;Hyun-Joong Hwang;Chang-Ho Hong;Jin-Seop Kim;Gye-Chun Cho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.509-523
    • /
    • 2023
  • The high-level nuclear waste (HLW) repository is exposed to complex environmental conditions consisting of high temperature, high humidity, and radiation, resulting in structural deterioration. Therefore, structural health monitoring is essential, and piezo sensors are used to detect cracks and estimate strength. However, since the monitoring sensors installed in the disposal tunnel and disposal container cannot be replaced or removed, the quantitative life of the monitoring sensor and its suitability must be assessed. In this study, the life of a piezo sensor for monitoring was assessed using an accelerated life test (ALT). The failure mode and mechanism of the piezo sensor under high temperature conditions were determined, and temperature stress's influence on the piezo sensor's life was analyzed. ALT was conducted on temperature stress and the relationship between temperature stress and piezo sensor life was suggested. The life of the piezo sensor was assessed using the Weibull probability distribution and the Arrhenius acceleration model. The suggested relationship can be used in multiple stress ALT designs for more precise life assessment.

A Study on the Estimation for the Guaranteed Strength and Construction Quality of the Combined High Flowing Concrete in Slurry Wall (지하연속벽용 병용계 고유동 콘크리트의 시공 품질 및 보증강도 평가에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.811-817
    • /
    • 2006
  • The primary purpose of this study is to estimate the guaranteed strength and construction quality of the combined high flowing concrete which is used in the slurry wall of underground LNG storage tank. The required compressive strength of this type of concrete become generally known as a non economical value because it is applied the high addition factor for variation coefficients and low reduction factor under water concrete. Therefore, after estimation of the construction quality and guaranteed strength in actual site work, this study is to propose a suitable equation to calculate the required compressive strength in order to improve its difference. Application results in actual site work are shown as followings. The optimum nix design proportion is selected that has water-cement ratio 51%, sand-aggregate ratio 48.8%, and replacement ratio 42.6% of lime stone powder by cement weight. Test results of slump flow as construction quality give average 616~634mm. 500mm flowing time and air content are satisfied with specifications in the rage of 6.3 seconds and 4.0% respectively. Results of strength test by standard curing mold show that average compressive strength is 49.9MPa, standard deviation and variation coefficients are low as 1.66MPa and 3.36%. Also test results by cored cylinder show that average compressive strength is 66.4MPa, standard deviation and variation coefficients are low as 3.64MPa and 5.48%. The guaranteed strength ratio between standard curing mold and cored cylinder show 1.23 and 1.32 in the flanks. It is shown that applied addition factor for variation coefficients and reduction factor under water concrete to calculate the required compressive strength is proved very conservative. Therefore, based on these results, it is proposed new equation having variation coefficients 7%, addition factor 1.13 and reduction factor 0.98 under water connote.

Stability Analysis of Concrete Liner installed in a Compressed Air Storage Tunnel (압축공기 저장용 터널에 설치된 콘크리트 라이닝의 안정성 해석)

  • Lee, Youn-Kyou;Park, Kyung-Soon;Song, Won-Kyong;Park, Chul-Whan;Choi, Byung-Hee
    • Tunnel and Underground Space
    • /
    • v.19 no.6
    • /
    • pp.498-506
    • /
    • 2009
  • The stability assessment of a concrete liner of a compressed air storage tunnel should be performed by an approach which is different from that commonly used for the liners of road tunnels, since the liner is exposed to high air pressure. In this study, the stability analysis method for the liner of compressed air storage tunnel is proposed based on the elastic and elasto-plastic solutions of the thick-walled cylinder problem. In case of elastic analysis, the yield initiation condition at the inner boundary is considered as the failure condition of the liner, while the condition which results in the extension of yielding zone to a certain depth is taken as a failure indicator of the liner in the elasto-plastic analysis taking Mohr-Coulomb criterion. The application of the proposed method revealed that the influence of the relative magnitude of boundary loads on the stability of liner is considerable. In particular, noting that the estimation of the outer boundary load may be relatively difficult, it is thought that the precise prediction of outer boundary load is very important in the analysis. Accordingly, the emphasis is put on the selection of the liner installation time, which may govern the magnitude of outer boundary load.

Analyses of Scenarios Based on a Leakage of Highly Compressed Air and Fire Anticipated in CAES (Compressed Air Energy Storage) Facility (압축공기에너지저장 시설에서 발생 가능한 압축공기 유출 및 화재 시나리오 분석)

  • Yoon, Yong-Kyun;Ju, Eun-Hye
    • Tunnel and Underground Space
    • /
    • v.25 no.6
    • /
    • pp.568-576
    • /
    • 2015
  • In this study, scenarios based on the leakage of highly compressed air and fire occurrence turned out to be high risks in an operation stage of CAES facility were constructed and estimated. By combining Bernoulli equation with momentum equation, an expression to calculate an impact force of a jet flow of compressed air was derived. An impact force was found to be proportional to the square of diameter of fracture and the pressure of compressed air. Four types of fire scenarios were composed to evaluate an effects that seasonal change and location of fire source have on the spread behavior of smoke. Smoke from the fire ignited in the vicinity of CAES opening descended more quickly below the limit line of breathing than one from the fire occurred 10 m away from CAES opening, which is expected to occur due to a propagation of wave front of smoke. It was shown that a rate of smoke spread of the winter fire is faster than one of the summer fire and smoke from the winter fire spreads farther than one of the summer fire, which are dependent on the direction of air flow into access opening. Evacuation simulation indicated that the required safe evacuation time(RSET) of the summer and winter fires are 262, 670 s each.

Development of Hydro-Mechanical Coupling Method for CO2 Sequestration and Its Application to Sleipner Project (이산화탄소 지중저장을 위한 수리-역학 연동 해석 기술 개발 및 적용 - 슬라이프너 프로젝트)

  • Kwon, Sangki;Lee, Hyeji
    • Tunnel and Underground Space
    • /
    • v.27 no.3
    • /
    • pp.146-160
    • /
    • 2017
  • $CO_2$ sequestration for alleviating global warming is a hot issue in the world. In this study, TOUGH2 and FLAC3D were combined for analyzing the hyro-mechanical coupling behaviors expected in $CO_2$ sequestration and applied it to Sleipner project carried out in Norway. In the analysis, the influence of pore pressure on in situ stress was considered and the influence of caprock permeability on hydro-mechanical behaviors was analyzed. In the condition of constant injection rate, pressure and saturation at the injection well, liquid and gas saturation in rock, major and minor stress variations with time and distance from the injection well, and horizontal and vertical displacements after injection could be investigated. The major principal stress was quickly increased in the early stage and then slowly decreased to a stable value, which was higher than the initial value. In contrast, the minor principal stress returned to initial value after some increase in the early stage. Surface upheaval was steadily increased and it was up to 15mm in 2 years after injection. When the caprock's permeability was changed from $3e-15m^2{\sim}3e-18m^2$, it was found that the injection well pressure and surface upheaval were inversely propotional to the permeability.

A Study on the Charateristic of the Groundwater Quality in Seoul (서울지역의 지하수 수질특성에 관한 연구)

  • 김익수;이재영;최상일
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.2
    • /
    • pp.54-63
    • /
    • 2004
  • For the purpose of finding out the distributions of groundwater uses, the effect of facilities on the parameter and the correlations among measurements, various statistical analysis were carried out with the data of groundwater quality measurements from January to December in 2002. (1) The rates of groundwater for drinking water were 10.5% in Yungcheon-Gu, 10.2% in Kangdong-Gu, and 9.9% in Eunpyung-Gu. The rates of other uses of groundwater were shown to be 58.1 %(786 wells) for civil defense emergency, 22.1% (299 wells) for contamination-concerning, 9.8%(133 wells) for water quality monitoring, consisting of 90% of all groundwater. (2) The 52.6% of groundwater for drinking were demonstrated to be appropriate while 91.9% for other uses-domestic, industrial, agricultural uses- were shown to be proper. (3) For drinking water, the maximum values of colar, turbidity, NH3-N, F, and Fe were 766.9 degree, 69.16NTU, 860.0 mg/l, 5.6 mg/l and 49.87 mg/l respectively. (4) Comparision of skewness and kurtosis for Seoul groundwater, pH was found to be 0.022 and -0.524, but the T.colony, color, turbidity, NH$_3$-N, NO$_3$-N, Fe and Mn respectively fumed out to be 11.641 and 174.324, 8.501 and 80.260, 5.675 and 32.821, 19.507 and 380.994, 3.323 and 17.436, 10.544 and 134.093 and 5.979 and 39.124. (5) In cases of drinking water wells for emergency, the results of statistical analysis showed that building year of the wells, depth and pumping rate didn't affect on whether it was proper for that use or not. It were shown that there were linear correlations between depth and NO3-N(-0.171) and F(0.332) while the correlation coefficients were 0.381 and -0.169 between the building year of well and depth and pumping rate respectively.

A Study on Ventilation System of Underground Low-Intermediate Radioactive Waste Repository (지하 동굴식 중-저준위 방사성 폐기물 처분장의 환기시스템 고찰)

  • Kim, Young-Min;Kwon, O-Sang;Yoon, Chan-Hoon;Kwon, Sang-Ki;Kim, Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.65-78
    • /
    • 2007
  • The pollutants (Rn, CH, CO, HS, radioactive gas from radiolysis) were generated from the process of construction and operation of underground repository, and after disposal of low-intermediate radioactive waste inside there must be controlled by a ventilation system to distribute them in area where enough air is supported. Therefore, a suitable technical approach is needed especially at an underground repository that is equipped with many entry tunnels, storage tunnels, exhaust-blowing tunnels, and vertical shafts in complicated network form. For the technical approach of such a ventilation system, WIPP (Waste Isolation Pilot Plant) in U. S and SFR (Slutforvar for Reaktorafall) low-intermediate radioactive waste repository in Sweden were selected as the models, for calculating the required air quantity, organizing a ventilation network considering cross section, length, surface roughness of the air passage, and describing a calculation of resistance of each circuit. Based on these procedures, a best suited ventilation system was completed with designing proper capacity of fans and operating plan of vertical shafts. As a result of comparing the two repositories based on the geometry dimensions and ventilation facility equipment operation, more parallel circuit as in WIPP, brought decrease in resistance for entire system leading to reduce of operating costs, and the larger cross-sectional area of the SFR, the greater the percentage of disposal capacity. Accordingly, the mixture of parallel circuit of WIPP repository for reducing resistance and SFR repository formation for enlargement of disposal capacity would be the most rational and efficient ventilation system.

  • PDF