• Title/Summary/Keyword: 지하수 플럭스

Search Result 10, Processing Time 0.031 seconds

Comparison between Passive Flux Meters and Borehole Dilution Tests to Estimate Groundwater Flux in a Karst Aquifer (플럭스미터와 단공희석시험을 이용한 카르스트 대수층 내 지하수 플럭스 측정 비교)

  • Lee, Juyeon;Yang, Minjune
    • Economic and Environmental Geology
    • /
    • v.53 no.5
    • /
    • pp.543-552
    • /
    • 2020
  • In this study, we measured groundwater fluxes with a passive flux meter and a borehole dilution test in the Upper Floridan Aquifer. In addition, the feasibility of the passive flux meter is also evaluated within matrix and non-matrix zones. The results of the PFM (5.96 ± 1.75 cm/day) showed good agreement with those of the BHD (4.68 ± 2.99 cm/day) in matrix zones, whereas the results of the PFM (9.94 ± 0.90 cm/day) showed poor agreement with those of the BHD (1817.37 ± 1795.50 cm/day) in non-matrix zones. We assumed that the groundwater passes through the sorbent material inside the PFM. However, it could not pass through the sorbent when the groundwater flux is faster than 11 cm/day. The flow might bypass between monitoring well and the PFM. The PFM used in this study might be suitable for measuring the groundwater fluxes under 11 cm/day. Therefore, more extensive research is needed in the future to measure fast groundwater fluxes (> 11 cm/day).

Surfactant recycling using micellar enhanced ultrafiltration

  • 양중석;백기태;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.177-180
    • /
    • 2004
  • 계면활성제를 이용한 오염된 토양을 복원하는데 있어 계면활성제의 회수하는 방법의 하나로 한외여과 방식의 타당성을 검토하였다. 계면활성제의 종류, 전해질과 첨가제로서의 알코올 및 휴믹 물질과 점토질에 의한 상대 플럭스의 변화와 투과액의 계면활성제의 농도 변화를 살펴보았다. 계면활성제의 경우 임계미셀농도 낮을수록 투과액의 농도가 낮았으며, 기타 첨가물은 농도에 비례하여 상대 플럭스가 감소하는 경향을 보였다.

  • PDF

Aanalysis between groundwater and evapotranspiration using in-situ dataset (현장관측 자료를 활용한 지하수와 증발산의 연관성 분석)

  • Kim, Daeun;Yang, Jeong-Seok;Kim, Il-Hwan;Lee, Jae-Beom;Choi, Minha
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.324-324
    • /
    • 2018
  • 지구 온난화로 인한 기후변화로 점차 가속됨에 따라 이로 인한 수자원 관리의 취약성이 증가되고 있는 전망이다. 물수지 순환에서 지하수와 증발산은 수자원 총량에서 많은 부분을 차지하고 있는 인자로써, 두 인자의 정량적인 분석은 지표와 대기 시스템의 분석에서 필수적이라고 할 수 있다. 지구의 담수 중 약 30%를 차지하고 있는 것이 지하수로써 이는 토양의 수원으로도 작용할 수 있으며, 특히 지하수면이 토양과 가까울수록 토양수분에 상당한 영향을 미칠 뿐만 아니라 증발산의 변동성과도 밀접하게 연결되어 있다. 지하수위 및 수문인자의 변화는 지하수를 활용하는 농업 및 수자원 관리와도 연계되어 있으므로 지하수와 증발산의 연관성에 대한 정량적인 변화의 비교/분석이 필수적이다. 또한 식생의 종류에 따른 지하수 및 증발산의 거동이 달라지게 됨으로 이에 대한 영향 또한 고려해야 한다. 그러나 지하수와 증발산의 직접적인 관계를 규명하는 선행연구가 아직 미흡하며, 국내 수자원분야에서의 두 인자간의 직접적인 연관성에 대하여 밝힌 연구는 거의 전무한 실정이다. 따라서 본 연구에서는 국내 플럭스 타워 관측 지점 중 다른 지표 특성 및 식생 조건을 가진 지역을 선정하여 각 다른 특성의 관측 지점에서의 분석을 실시하고자 한다. 관측된 수문기상인자인 증발산, 강수량과 관측 지점에서 가장 가까운 지하수 측정망으로부터 획득된 지하수 자료를 활용하여 각 인자들 사이의 연관성을 비교/분석을 실시하여 수문순환에서의 이들 간의 영향 정도를 파악할 예정이다.

  • PDF

Sulfur Cycle in the Rehabilitated Forest Catchment in Tanakami Mountain, Kansai District, Japan (일본 칸사이 지방 타나카미 산지의 황폐지 복구 산림유역 내 황(黃)순환에 관한 연구)

  • Kim, Su-Jin;Ohte, Nobuhito;Park, Jong-Kwan
    • Journal of the Korean Geographical Society
    • /
    • v.44 no.4
    • /
    • pp.429-446
    • /
    • 2009
  • To understand the sulfur flux and cycle in the forest catchment, the hydrological processes and chemical variation of soil solution, groundwater and stream water were analyzed at the Matsuzawa catchment located in the Kiryu Experimental Basin, Shiga Prefecture, central Japan. Unsaturated soil layer at the upper slope of catchment was the source area of ${SO_4}^{2-}$, and deep soil layer and groundwater were the sink zone of ${SO_4}^{2-}$. The vertical distribution of ${SO_4}^{2-}$ concentrations in groundwater affected seasonal variation of ${SO_4}^{2-}$ concentrations in stream water, as groundwater level changed. It is reasonable to assume that each hydrological processes in the forest catchment play an important roles in the retention and discharge of ${SO_4}^{2-}$.

Effect of Humic Substances on the Simultaneous Removal of Nitrate and Phosphate in a Micellar-Enhanced Ultrafiltration (MEUF) (미셀 한외여과(MEUF)를 이용한 질산성 질소와 인산의 동시제거 시 휴믹산의 영향)

  • 김보경;백기태;김호정;양지원
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.3
    • /
    • pp.30-36
    • /
    • 2003
  • The effect of humic acid on the simultaneous removal of nitrate and phosphate was investigated in a micellar-enhanced ultrafiltration (MEUF). At the low molar ratio of cetylpyridinium chloride (CPC) to contaminants, the removal of nitrate was lower to 50% by 100 ppm of humic acid due to the competition for binding on micelles. At the molar ratio higher than 3, however, the removal of nitrate was over 80%. Phosphate was removed over 80% at the molar ratio higher than 1. The CPC and humic acid were rejected over 99 % by UF membrane. The flux did not decrease by 100 ppm of humic acid but rather slightly increased since the humic acid adsorbed on the membrane made the membrane more hydrophilic. As a result, humic acid did not diminish the performance of MEUF in the simultaneous removal of nitrate and phosphate.

Application of PAC-Membrane System for Treating Groundwater Contaminated with Chlorinated Organic Compounds (유기염소화합물로 오염된 지하수를 처리하기 위한 PAC-막분리 공정의 적용)

  • Lim, Joong-Kun;Kang, Min-Su;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.8
    • /
    • pp.892-899
    • /
    • 2005
  • Groundwater is naturally of excellent microbiological qualify and generally of adequate quality for drinking water use. However, recently, the impact of urbanization and intensification of agricultural production have led to serious deterioration in groundwater quality. The representative SOCs used in this study were trichloroethylene (TCE) and tetrachloroethylene (PCE). Powdered activated carbon (PAC) is widely used for SOCs removal. The overall goal of this study was to demonstrate the feasibility of using a hybrid use of PAC-UF and PAC-MF processes for treating groundwater contaminated with TCE and PCE. The results show that the flux decline rate was lower for the PAC-UF or PAC-MF process than for UF or MF only process. Therefore, applying PAC before UF or MF membrane filtration showed not only enhancing the removal of TCE and PCE, but also reducing membrane fouling.

A Study on the Removal of Dissolved Matter in Groundwater and Characteristics of Fouling using NF and RO (NF와 RO를 이용한 지하수중 용존성 물질의 제거와 막 오염의 특성에 관한 연구)

  • Gwon, Eun-Mi;Yu, Myong-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2205-2213
    • /
    • 2000
  • To investigate removal efficiency of dissolved matter by NF and RO, a pilot plant was operated for six months using groundwater treated by UF membrane. After the pilot plant operation, we performed autopsy test to identify characteristics of foulant attached on the membrane surface applying the used NF and RO in the pilot plant test. In autopsy test, we measured permeate flux and recovery rate of flux by chemical cleaning in each membrane. We also analyzed chemical cleaning disposal to examine component of foulant. Permeate flux of NF and RO1 showed rapid decline after 100 days of operation. Especially, reduction of specific flux in RO1 was more serious than in NF. Specific flux of RO2 with a low recovery rate resulted in gradual flux decline. Removal efficiencies of dissolved inorganic matters as a conductivity were 76.3%, 88.2% and 95.3% respectively for NF, RO1 and RO2, and RO2 presented the highest removal efficiency. And those of dissolved organic matters as TOC were about 80% for both NF and RO. The specific flux of membranes declined gradually from the feed water inlet to outlet of the membrane module and it showed that membrane fouling increased along the feed flow direction. Namely, concentration of pollutants became higher and volume of feed water was less as the feed flow approached to the outlet. It seemed that major foul ants were Ca consolidated into inorganic material and Si consolidated into organic material on the membrane surface. Fe was a great contribution to irreversible fouling. The SEM results indicated that the organic matter was attached to the first layer, closer to the membrane, and then inorganic matter with tetragonal shape layered over them. We could not observe biofouling because microorganism, which was cause of biofouling, was almost pretreated in UF membrane.

  • PDF

Calculation of TDR Sensor Coefficient through Measurement of Soil Sample (토양시료 측정을 통한 TDR 센서 계수 보정)

  • Moon, Duck Young;Lim, Kwang Suop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.76-76
    • /
    • 2015
  • 토양수분은 생태수문학에서 식생과의 상호작용의 중요한 인자이자, 대기와의 상호작용으로 인한 총체적인 물 순환에 밀접한 관련이 있다. 수문학적으로는 증발, 침투, 지하수 함량, 토양 침식, 식생 분포 등을 지배하는 중요한 요소이고, 특히 시 공간적 분포특성은 강수 사상 후 토양으로의 침투 및 토양수분의 재분포, 증발산과 불포화대에서의 오염물의 이송을 예측하는데 매우 중요하다. 또한, '07년 하천법 개정으로 증발산량 및 토양수분량이 신규 수문조사 항목으로 추가되어, 토양수분 측정에 대한 필요성이 높아졌다. 따라서, 2008년 5월, K-water연구원에서는 현재 시험유역으로 운영하고 있는 용담시험유역에 토양수분관측망(6개 관측소)을 구축하였다. 토양수분계는 토양수분을 결정하는 가장 중요한 인자인 강우자료의 획득이 이루어지는 지점에 설치하여 정확도와 신뢰도를 높일 수 있도록 용담시험 유역 내 6개 우량관측소에 설치하였다. 하지만 장비의 노후화에 따른 자료 취득의 어려움으로 인하여 2013년 4월, 토양수분계를 전면 교체하였다. 토양수분계는 기존의 FDR 방식에서 EC 농도에 대한 영향이 가장 적고, 플럭스 타워에 위치한 토양수분계 센서와 동일한 TDR 방식의 센서로 장비를 전면 교체하였다. 센서 설치 장소 변경에 따른 TDR 센서의 검증과 그리고 흙의 종류, 입도, 다짐도, 온도 등에 의한 오차가 발생 여부를 판단하기 위하여 이에 대한 보정을 실시하였다. 원지반 시료채취를 통하여 토양수분량을 측정하였고, TDR 센서에 의해 측정된 토양수분량과 채취된 시료에서 측정된 토양수분량의 결과를 비교하였고, 각 지점별 토양구성비와 전기전도도 조건을 고려하여 각 토층별 계수적용을 달리하여 센서 보정을 실시하였다. 그 결과 기존 센서 제조사에서 제안한 방정식을 그대로 사용하는 것 보다는 센서 검증을 통하여 얻은 계수보정에 의한 토양수분 변환식을 사용하는 것이 정확한 현장 자료를 확보할 수 있고, 신뢰도 높은 자료를 얻을 수 있다고 판단된다.

  • PDF

Estimation of low flow by grid-based continuous hydrologic modelling (격자기반 분포형 수문모델링을 활용한 하천갈수량 산정)

  • Lee, Yonggwan;Jang, Wonjin;Lee, Jiwan;Han, Daeyoung;Kim, Seongjoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.34-34
    • /
    • 2021
  • 본 연구에서는 격자기반 분포형 수문모델링을 통해 하천갈수량을 추정하고자 한다. 분포형 수문모형은 단방향흐름 알고리즘에 의한 토양 물수지식을 기반으로 개발되었으며 운동파(kinematic wave) 이론을 적용하여 지표 및 지표하 유출을 모의한다. 또한, 격자별로 수문학적 물수지요소인 차단량, 증발산량, 침투 및 침루량, 지하수충전량 등을 계산하며, 댐·보 방류량을 해당 지점 격자의 물수지에 적용할 수 있도록 개발하였다. 본 모형은 2개의 다목적댐과 3개의 다기능보가 위치한 금강유역(9,645.5 km2)에 적용하였으며, 유역 면적과 하천 유속을 고려하여 1 km × 1 km 격자를 구성하고 10분 간격으로 2013년부터 2020년까지 수문모의를 진행하였다. 모형의 입력자료로 유역 인근의 12개 기상관측소로부터 시단위 기상자료를 구축하였으며, 모형의 검보정은 일단위 관측유량(Q), 플럭스 타워 증발산량, 실측 토양수분 및 지하수위 자료를 구축하여 활용하였다. 댐 및 보 지점에 대해 Q와 1/Q로 검보정을 수행한 결과, 평균 결정계수(R2)는 댐 지점에서 0.53~0.65, 보 지점에서 0.46~0.69의 값을 나타냈으며, Nash-Shtcliffe efficiency(NSE)는 댐 지점에서 0.46~0.55, 보 지점에서 0.31~0.65의 값을 나타냈다. 공간 보정을 위해 증발산량, 토양수분, 지하수위에 대한 검보정을 수행할 예정이며, 유황곡선을 활용하여 하천차수, 토양속성 및 토지이용에 따른 하천갈수량을 분석할 예정이다.

  • PDF

Application of WEP Model to the Cheonggecheon Watershed (청계천 유역에 대한 WEP 모형의 적용)

  • Noh, Seong Jin;Kim, Hyeon Jun;Cheong, Il Moon;Jang, Cheol Hee;Kim, Dong Pil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.148-152
    • /
    • 2004
  • 본 연구에서는 물순환의 재생이나 보전에 필수적인 유역 물순환의 정량화와 유역변화의 영향예측을 위해 개발된 WEP (Water and Energy Transfer Process) 모형의 국내 유역에 내한 적용성을 검토하고, 청계천 유역의 물순환 양상을 모의하였다. WEP 모형은 복잡한 토지이용이 이루어지고 있는 도시하천 유역에 내한 물순환의 정량화를 목적으로 일본의 토목연구소 (PWRI; Public Works Research Institute), 과학기술진흥사업단, Jia 박사 등에 의해 공동으로 개발되었으며 지표면 및 비포화 토양층의 물${\cdot}$열 플럭스 계산, 하도흐름의 추적계산 및 지하수 유동계산, 격자내 토지이용의 불균질성 반영 등이 가능한 물리적인 기반의 공간 분포형 모형 (Physically Based Spatially Distributed)이다. 모형을 적용한 청계천 유역 (유로연장 13.75 km, 유역 면적 $50.96km^2$)은 전체 토지이용중 도시지역이 $75.9\%$를 차지하고, 유역내 인구가 120만명에 이르는 도시유역으로 높은 불투수 면적비율, 인공계 물순환 요소의 영향 등의 도시 유역 특성이 물순환의 구조 전반에 미치는 영향에 대한 연구가 부족하였다. WEP 모형 적용 결과, 모의 기간 동안의 하천 유출량은 실측치에 근사한 값을 나타내었으며 유역의 물순환 양상을 모의할 수 있었다. 청계천 유역은 전형적인 도시 유역의 특성을 보여주었는데, 강우시의 직접유출이 크고, 강우의 유출에 대한 반응이 빠르며, 증발산의 경우는 산림지역보다 도시지역이 상대적으로 적은 것으로 분석되었다. 이번 연구를 통하여 WEP 모형이 유역 물순환 해석에 적절한 모형임을 확인할 수 있었으면, 향후 청계천 유역의 물리적 특성에 대한 매개변수와 인공계 물순환 자료의 보완을 통해 보다 향상된 모의가 가능할 것으로 판단된다. 하였던 Cd과 Mg이 Ca 및 Ca과 vitamin D의 동시(同時) 급여(給與)로 감소(減少)하였고 Cu는 전체적(金體的)으로 변화(變化)가 없었으며 Zn은 Cd 급여(給與)로 감소(減少)하였으나 Ca과 vitamin D의 급여(給與)에 의하여 증가(增加)하였고 Ca은 Ca과 viamin D의 급여(給輿)로 유의(有意)하게 증가(增加)하였다. 신장(腎臟)중의 무기질(無機質) 함량(含量)은 Cd급여(給輿)로 Cu, Mg은 감소(滅少)하였으나 Ca, Zn은 변화(變化)가 없었고 Ca 및 Ca과 Vitamin D의 급여(給與)로 Cd, CU, Zn은 증가(增加)하였다.ce area)는 수술 전100.8$\pm$25.6 mm/$m^{2}$에서 79.3$\pm$ 15.8 mm/$m^{2}$로 감소한 소견을 보였다. 승모판 성형술은 전 승모판엽 탈출증이 있는 두 환아에서 동시에 시행하였다. 수술 후 1년 내 시행한 심초음파에서 모든 환아에서 단지 경등도 이하의 승모판 폐쇄 부전 소견을 보였다. 수술 후 조기 사망은 없었으며, 합병증으로는 유미흉이 한 명에서 있었다. 술 후 10개월째 허혈성 확장성 심근증이 호전되지 않아 Dor 술식을 시행한 후 사망한 예를 제외한 나머지 6명은 특이 증상 없이 정상 생활 중이다 결론: 좌관상동맥 페동맥이상 기시증은 드물기는 하나, 영유아기에 심근경색 및 허혈성 심근증 또는 선천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고 있다.교하여 유의한 차이가 관찰되지 않았다. 또한 HSP 환자군에서도 $IL1RN^{*}2$ allele 빈도와 carriage

  • PDF