• Title/Summary/Keyword: 지진 재현주기

Search Result 40, Processing Time 0.027 seconds

Disaster-Prevention System of Transportation Network used by GIS and Seismic Fragility Analysis (GIS 및 지진취약도 분석기법을 이용한 교통 네트워크의 방재 시스템)

  • Lee, Hyung-Jin;Park, Byung-Hee;Jang, Il-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.2 s.21
    • /
    • pp.25-35
    • /
    • 2006
  • Recently seismic fragility analysis method has been widely used for the seismic probabilistic risk assessment of infrastructures such as nuclear power plants, buildings and bridges because of its probabilistic characteristics. Furthermore, this technique has been applied to large-scale social systems consisted of each infrastructures by combing GIS. In this paper, the applicability of this technique to domestic infrastructural systems was studied. The transportation network was selected as one of these domestic infrastructural systems. Example studies were peformed about Changwon city. Nonlinear time history analysis, with a maximal likelihood approach were conducted to establish the fragility curves of each infrastrucures (bridges). GIS analysis was also applied to the analysis of whole infrastructural systems. The results show that it is very useful to predict seismic probabilistic risk assessment of this domestic transportation network. However, it also shows that further studies such as more suitable damage criterion to domestic structure and precise nonlinear analysis techniques should be developed to predict more precise results.

Fluid force coefficient of Imwon port accoding to 3-D hydraulic model test (3차원수리모형실험을 통한 임원항의 파력산정계수(α) 도출)

  • Yoon, Jae Seon;Jung, Jae-Sang;Ryu, Im-Do;Song, Hyun-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.255-255
    • /
    • 2015
  • 지진해일은 주기가 긴 파랑으로 방파제나 방호구조물에 의한 에너지 감소가 작은 특성이 있다. 또한, 범람구역의 구조물 밀집도 및 지형적 요인에 따라 범람영역, 침수심, 파력 등이 상이하게 나타나므로 유체흐름의 입체적 변화양상을 고려하여야 한다. 본 수리모형실험은 임원항을 대상으로 구조물에 작용하는 지진해일의 파력특성을 3차원수리모형실험을 통해 검토하고, 파력산정계수(${\alpha}$)를 제시한다. 3차원 수리모형실험은 1983년 동해 중부 지진해일 발생 시 국내에서 가장 큰 피해를 입은 임원항을 대상으로 배후부지의 구조물과 인근 해안의 지형을 1/100으로 재현하여 실험에 임하였다. 입사파랑은 고립파(solitary wave)로 재현하였으며, 천수(shoaling)에 의한 파고변화를 측정하고 그에 따른 배후부지의 침수심, 구조물에 작용하는 파력을 측정하였다. 분석된 파력 산정계수(${\alpha}$)는 임원항 인근 해역 및 배후부지의 방재대책 수립을 위한 기초자료로 활용될 것으로 판단된다.

  • PDF

Generation of Design Response Spectrum and Earthquake Ground Motion Considering the Recurrence Period (재현주기에 따른 응답스펙트럼과 설계지반운동 산정방법)

  • 이현호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.58-65
    • /
    • 1998
  • A purpose of this research is to develope the calculation methods of design input seismic loads, Where, calculation methods are ; (1) Considering different recurrence period of earthquakes which was proposed by ATC 14. (2) Using earthquake records which was modified Korean codes. Responce spectra that was adopted by codes has an estimated recurrence interval of 500 years, with approximately a 90 percent probability of not being exceeded in 50 years. But If we considered the life-time of existing buildings in some cases, response spectra be modified with return period of earthquakes. If we be design highrise and irregular buildings, dynamic analysis method that use time history records should be used. But in Korea, time history records of earthquakes was very few. Therefore to use foreign countries's earthquake record, it is need to select of records considered Korean coeds. As a results, this study propose a calculation method of seismic design input loads that considered return period of earthquakes and also propose using method of earthquakes.

  • PDF

One Dimensional Seismic Response Analysis on Sub-ground of Architectural Heritage in Seoul, Korea (서울지역 주요 문화재 하부 지반에 대한 일차원 지진응답해석)

  • Jeon, Seongkon;Kim, Dukmoon;Kwon, Youngcheul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.9
    • /
    • pp.29-36
    • /
    • 2014
  • Under the situation that the seismic vulnerability are a worsening problem in many world's megacities, the disaster preparedness including earthquake hazards is a matter of primary concern in the capital city of Korea, Seoul. Especially, because it is hard to move or dismantle the architectural heritages, the mitigation of earthquake damages is potentially more difficult than other structures. Moreover, in order to decide the proper preparedness plan against future earthquakes, it is very important to understand how soils pass the seismic waves to architectural heritages. In this paper, therefore, the ground condition and depth of bedrock was investigated by the MASW-method at heritages located in Seoul. Then one-dimensional seismic response analysis was conducted based on the distribution of shear wave velocity. As the major result of analyses, peak acceleration, site amplification factor and natural period are proposed in each site for recurrence period.

Capacity Spectrum Method Based on Inelastic Displacement Ratio (비탄성변위비를 이용한 능력 스펙트럼법)

  • Han, Sang-Whan;Bae, Mun-Su
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.69-80
    • /
    • 2008
  • In this study, improved capacity spectrum method (CSM) is proposed. The method can account for higher mode contribution to the seismic response of MDOF systems. The CSM has been conveniently used for determining maximum roof displacement using both demand spectrum and capacity curve of equivalent SDOF system. Unlike the conventional CSM, the maximum roof displacement is determined without iteration using inelastic displacement ratio and R factor calculated from demand spectrum and capacity curve. Three moment resisting steel frames of 3-, 9- and 20-stories are considered to test the accuracy of the proposed method. Nonlinear response history analysis (NL-RHA) for three frames is also conducted, which is considered as an exact solution. SAC LA 10/50 and 2/50 sets of ground motions are used. Moreover, this study estimates maximum story drift ratios (IDR) using ATC-40 CSM and N2-method and compared with those from the proposed method and NL-RHA. It shows that the proposed CSM estimates the maximum IDR accurately better than the previous methods.

Reliability Based Design of Caisson type Quay Wall Using Partial Safety Factors (부분안전계수를 이용한 케이슨식안벽의 신뢰성설계법)

  • Kim, Dong-Hyawn;Yoon, Gil-Lim
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.21 no.3
    • /
    • pp.224-229
    • /
    • 2009
  • Partial safety factors(PSFs) for Level I reliability based design of caisson type quay walls were calculated. First order reliability method(FORM) based PSFs are the functions of sensitivities of limit state function with respect to design random variables, target reliability index, characteristic values and first moment of random variables. Modified PSFs for water level and resilient water level are newly defined to keep consistency with the current design code. In the numerical example, PSFs were calculated by using a target reliability index. Seismic coefficient is defined to show extreme distribution. It was found that PSFs for seismic coefficient becomes smaller as the return period for design seismic coefficient grows longer.

A Study on the Earthquake Safety Assessment of Energy Storage Facilities According to Climate Change (기후변화에 따른 에너지 저장시설 지진 안전성평가에 관한 연구)

  • Ham, Eun-Gu;Lee, Sung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.226-235
    • /
    • 2021
  • Purpose: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Method: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Result: In this study, by statically loading earthquake loads and evaluating the level of collapse prevention of special-class structures, facility managers can easily recognize and evaluate the risk level, and this analysis result can be applied to future facility risk management. Earthquake analysis was performed so that. Conclusion: As a result of analyzing the Coalescer facility according to the current design standard KBC2016, the stress ratio of the main supporting members was found to be up to 4.7%. Therefore, the members supporting Coalescer were interpreted as being safe against earthquakes with a reproducibility period of 2400 years that may occur in Korea.

Dynamic Behavior Evaluation of Pile-Supported Slab Track System by Centrifuge Model Test (원심모형 실험을 통한 궤도지지말뚝구조의 동적 거동 평가)

  • Yoo, Mintaek;Lee, Myungjae;Baek, Mincheol;Choo, Yun-Wook;Lee, Il-Wha
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.2
    • /
    • pp.5-17
    • /
    • 2019
  • Dynamic centrifuge model test was conducted to evaluate the dynamic stability of the pile-supported slab track method during dynamic railway loading and earthquake loading. The centrifuge tests were carried out for various condition of embankment height and soft ground depth. Based on test results, we found that the bending moment was increased with embankment height and decreased with soft ground depth. In addition, it was confirmed that the pile-supported slab track system could have dynamic stability for short-period seismic loading. However, in case of long-period seismic loading, such as Hachinohe earthquake, the observed maximum bending moment reached to pile cracking moment at the return period of 2,400 year earthquake. The criterion of ratio between embankment height and soft ground depth was suggested for dynamic stability of pile-supported slab track system.

Analytical Simulation of Shake-Table Responses of a 1:5 Scale 10-story Wall-type RC Residential Building Model (1:5 축소 10층 벽식 RC 공동주택 모델의 진동대실험 응답에 대한 해석적 모사)

  • Lee, Han-Seon;Jeong, Da-Hun;Hwang, Kyung-Ran
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.6
    • /
    • pp.617-627
    • /
    • 2011
  • This paper presents the results of analytical simulation of shake-table responses of a 1:5 scale 10-story reinforcement concrete(RC) residential building model by using the PERFORM-3D program. The following conclusion are drawn based on the observation of correlation between experiment and analysis; (1) The analytical model simulated fairly well the global elastic behavior under the excitations representative of the earthquake with the return period of 50 years. Under the design earthquake(DE) and maximum considered earthquake(MCE), this model shows the nonlinear behavior, but does not properly simulate the maximum responses, and stiffness and strength degradation in experiment. The main reason is considered to be the assumption of elastic slab. (2) Although the analytical model in the elastic behavior closely simulated the global behavior, there were considerable differences in the distribution of resistance from the wall portions. (3) Under the MCE, the shear deformation of wall was relatively well simulated with the flexural deformation being overestimated by 10 times that of experiment. This overestimation is presumed to be partially due to the neglection of coupling beams in modeling.

Seismic Performance Evaluation and a Comparative Study on the Design Wind and Earthquake Loads for Power Transmission Towers (송전철탑의 내진성능평가 및 설계 풍하중과 지진하중의 비교 연구)

  • Hwang, Kyeong-min;Chun, Nak-hyun;Jang, Jung-bum;Yun, Kwan-hee;Kim, Tae-kyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.2
    • /
    • pp.75-81
    • /
    • 2019
  • In this study 24 power transmission towers were selected by considering various variables such as power transmission capacity, height and structural type to evaluate their seismic performance using the standard design response spectrum recently announced by the government. In addition, the stresses and sectional forces generated by the current design wind loads and revised seismic ones were compared to review the effects on the design of power transmission towers when the government-required seismic standards were raised. The results of seismic performance evaluation for the target power transmission towers showed that they had seismic capacity of 0.31~0.91g, and that they met the level of the earthquake-resistant special grade, which is the 2,400-year earthquake return periods and secured seismic safety. Further, the sectional forces caused by earthquakes in the towers were 33~82.5% of the ones due to wind loads, and it was also confirmed that the design wind loads were more dominant than design earthquake ones under the elevated seismic standards.