• Title/Summary/Keyword: 지진연구센터

Search Result 106, Processing Time 0.021 seconds

쓰나미 피해범위의 간이평가법

  • Song, Byeong-Ung
    • Geotechnical Engineering
    • /
    • v.27 no.4
    • /
    • pp.17-23
    • /
    • 2011
  • 지난 3월 11일 오후 2시 46분 삼육(三陸: Sanriku)앞바다에서 규모 9.0의 지진이 발생하였고 잠시 후 쓰나미(津波)가 발생하여 아직도 피해 규모를 정확히 파악할 수도 없을 정도로 많은 피해를 일으켰다. 피해자들에게는 잊을 수 없이 많은 안타까움과 고통이 따르겠지만, 앞으로 다른 곳에서도 발생할 수 있는 문제이므로 학문을 연구하는 연구자들은 반드시 대책을 수립하지 않으면 안 된다. 이번 기회를 통하여 우리 학회 회원님들께 쓰나미에 대해서 설명 드리고자 한다. 본 글은 일본 국토기술연구센터(國土技術硏究センタ一)(2007)의 자료를 대부분 정리하여 작성한 글임을 밝혀둔다.

  • PDF

Basic study on development of the radon measurement system in groundwater stations for the seismic monitoring and prediction (지진모니터링과 예측을 위한 지하수관측소내 라돈 측정시스템 개발 기초연구)

  • Jang, Suk Hwan;Lee, Jae-Kyoung;Lee, Sang Yoon;Oh, Kyung Doo
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.7
    • /
    • pp.507-519
    • /
    • 2020
  • This study developed the radon measurement system that can be used for crustal movement monitoring and seismic occurrence and prediction, and compared and analyzed the results of test-operated radon measurement system and observed seismic occurrence cases. First, the developed radon measurement system consists of an NB-IoT radon measurement device, data center, data analysis, and data supply server. Because the measured radon data can be remotely trasmitted by using NB-IoT, this system is very suitable for installation and operation in unmaaned groundwater station. Second, the developed radon measurement device was test-operated at two groundwater stations in Gimpo from May to July 2019. The measured radon data was compared with the groundwater-level and electrical conductivity measurement data, and it was confirmed that the radon measurement device developed in this study has some potential for commercialization. Finally, from November 2019 to February 2020, three observed seismic cases and daily measured radon, groundwater-level, electrical conductivity data by the NB-IoT radon measurement device installed at three groundwater stations in Pohang, which is a test-bed, were compared and analyzed. As a result of the analysis, it was confirmed that the seismic occurrence correlated with radon, groundwater level, and electrical conductivity and all of these measured data will be able to provide basic data to help in seismic monitoring and prediction in the future.

Monitoring of Subsurface Temperature Variation as Geothermal Utilization (지종열 활용에 따른 온도변화 모니터링)

  • Lee, Tae-Jong;Shim, Byoung-Ohan;Song, Yoon-Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.1
    • /
    • pp.29-35
    • /
    • 2010
  • Long-term temperature monitoring has been performed for ground heat exchanger at the Earthquake Research Center (ERC) building in Korea Institute of Geoscience and Mineral Resources (KIGAM). For the 3 years of monitoring, overall temperature increases are observed at various depths within a borehole heat exchanger. But monitoring of ground temperature variation at the monitoring well beforehand showed that geothermal utilization is not the only source for the temperature increase, Because various kinds of sources can cause the ground temperature change, more thorough investigation should be followed.

Seismic Retrofit Scheme of FRP Column Jacketing System for Non-Seismic RC Building Frame (비내진 철근콘크리트 건축물의 FRP 재킷에 대한 내진보강 설계 전략)

  • Hwang, Heejin;Kim, Haewon;Oh, Keunyeong;Shin, Jiuk
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.293-301
    • /
    • 2023
  • Existing reinforced concrete buildings with seismically deficient details have premature failure under earthquake loads. The fiber-reinforced polymer column jacket enhances the lateral resisting capacities with additional confining pressures. This paper aims to quantify the retrofit effect varying the confinement and stiffness-related parameters under three earthquake scenarios and establish the retrofit strategy. The retrofit effects were estimated by comparing energy demands between non-retrofitted and retrofitted conditions. The retrofit design parameters are determined considering seismic hazard levels to maximize the retrofit effects. The critical parameters of the retrofit system were determined by the confinement-related parameters at moderate and high seismic levels and the stiffness-related parameters at low seismic levels.

Tension Measurement of Stay Cables in Consideration with Image Including Vehicle (차량이 포함된 이미지를 고려한 사장재 케이블의 장력 측정 )

  • Sung-Wan Kim;Dong-Uk Park;Jin-Soo Kim;Seung-Su Park;Jae-Bong Park
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.58-66
    • /
    • 2023
  • In this study, cable tension was measured using the vibration method, and a vision-based system was applied as a sensor to measure the displacement response of a cable in a non-contact method. In the vision-based system, the camera is installed in a location that considers the target structure and the field of view of the camera. However, it can be difficult to recognize the control points required to measure the displacement response of a structure as the target structure and other structures such as vehicles may be included in the image at the intended installation location. In this study, a distorted image including a vehicle shows inaccurate results in image analysis due to the installation position of the vision-based system. Accordingly, the image including the vehicle was eliminated by calculating the similarity between the two images. To verify the validity of the method of estimating the cable tension of cable-stayed bridges using the proposed method, the vibration method was applied to cable-stayed bridges in service to measure the tension.

A Study on Seismic Liquefaction Risk Map of Electric Power Utility Tunnel in South-East Korea (국내 동남권 지역의 전력구 지반에 대한 지진시 액상화 위험도 작성 연구)

  • Choi, Jae-soon;Park, Inn-Joon;Hwang, Kyengmin;Jang, Jungbum
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.10
    • /
    • pp.13-19
    • /
    • 2018
  • Following the 2016 Gyeongju earthquake, the Pohang Earthquake occurred in 2017, and the south-east region in Korea is under the threat of an earthquake. Especially, in the Pohang Earthquake, the liquefaction phenomenon occurred in the sedimentation area of the coast, and preparation of countermeasures is very important. The soil liquefaction can affect the underground facilities directly as well as various structures on the ground. Therefore, it is necessary to identify the liquefaction risk of facilities and the structures against the possible earthquakes and to prepare countermeasures to minimize them. In this study, we investigated the seismic liquefaction risk about the electric power utility tunnels in the southeast area where the earthquake occurred in Korea recently. In the analysis of seismic liquefaction risk, the earthquake with return period 1000 years and liquefaction potential index are used. The liquefaction risk analysis was conducted in two stages. In the first stage, the liquefaction risk was analyzed by calculating the liquefaction potential index using the ground survey data of the location of electric power utility tunnels in the southeast region. At that time, the seismic amplification in soil layer was considered by soil amplification factor according to the soil classification. In the second stage, the liquefaction risk analysis based on the site response analyses inputted 3 earthquake records were performed for the locations determined to be dangerous from the first step analysis, and the final liquefaction potential index was recalculated. In the analysis, the site investigation data were used from the National Geotechnical Information DB Center. Finally, it can be found that the proposed two stage assessments for liquefaction risk that the macro assessment of liquefaction risk for the underground facilities including the electric power utility tunnel in Korea is carried out at the first stage, and the second risk assessment is performed again with site response analysis for the dangerous regions of the first stage assessment is reasonable and effective.

Accumulation of Natural and Artificial Radionuclides in Marine Products around the Korean Peninsula: Current Studies and Future Direction (국내산 수산물 내 자연 및 인공방사능 축적 연구 현황 및 향후 연구 방향)

  • Lee, Huisu;Kim, Intae
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.618-629
    • /
    • 2021
  • The Fukushima nuclear power plant (NPP) accident caused by the East Japan Earthquake in 2011 and the recent increase in the frequency of earthquakes in Korea have caused safety concerns regarding radionuclide exposure. In addition, the Tokyo Electric Power Company (TEPCO) in Japan recently decided to release radionuclide-contaminated water from Fukushima's NPP into the Pacific Ocean, raising public concerns that the possibility of radionuclide contamination through both domestic- and foreign fishery products is increasing. Although many studies have been conducted on the input of artificial radionuclides into the Pacific after the Fukushima NPP accident, studies on the distribution and accumulation of artificial radionuclides in marine products from East Asia are lacking. Therefore, in this study, we attempted to explore recent research on the distribution of artificial radionuclides (e.g., 137Cs, 239+240Pu, 90Sr, and etc.) in marine products from Korean seas after the Fukushima NPP accident. In addition, we also discuss future research directions as it is necessary to prepare for likely radiation accidents in the future around Korea associated with the new nuclear facilities planned by 2030 in China and owing to the discharge of radionuclide-contaminated water from the Fukushima NPP.

Validation on the Bodywave Magnitude Estimation of the 2017 DPRK's Nuclear Test by Source Scaling (지진원 상대비율 측정법을 이용한 2017년 북한 핵실험의 실체파 규모 검증)

  • Kim, Tae Sung
    • Economic and Environmental Geology
    • /
    • v.51 no.6
    • /
    • pp.589-593
    • /
    • 2018
  • Democratic Peoples' Republic of Korea (DPRK) conducted the $6^{th}$ underground nuclear test at the Punggye-ri underground nuclear test site on September 27, 2017 12 hours 30 minutes of Korean local time. Comprehensive Nuclear-Test Ban Treaty Organization (CTBTO) under U.N. announced the body wave magnitude of the event was mb 6.1 while U.S. Geological Survey (USGS)'s calculation was mb 6.3. In this study, the differences of the magnitude estimates were investigated and verified. For this purpose, a source scaling between the $5^{th}$ and $6^{th}$ event, which's epicenters are 200 meters apart, was performed using seismic data sets from 30 broadband stations. The relative amplitude variations of the $6^{th}$ event compared to the $5^{th}$ event in the frequency domain was analyzed through the scaling. The increased amount of the bodywave magnitude $m_b$ for the $6^{th}$ event was calculated at 1 Hz, which was compared to those from USGS and CTBTO's calculations.

Comparison and Analysis of Matching DEM Using KOMPSAT-3 In/Cross-track Stereo Pair (KOMPSAT-3 In/Cross-track 입체영상을 이용한 매칭 DEM 비교 분석)

  • Oh, Kwan-Young;Jeong, Eui-Cheon;Lee, Kwang-Jae;Kim, Youn-Soo;Lee, Won-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_3
    • /
    • pp.1445-1456
    • /
    • 2018
  • The purpose of this study is to compare the quality and characteristics of matching DEMs by using KOMPSAT-3 stereo pair capture in in-track and cross-track. For this purpose, two stereo pairs of KOMPSAT-3 were collected that were taken in the same area. The two stereo pairs have similar stereo geometry elements such as B/H, convergence angle. Sensor modeling for DEM production was performed with RFM affine calibration using multiple GCPs. The GCPs used in the study were extracted from the 0.25 m ortho-image and 5 meter DEM provided by NGII. In addition, matching DEMs were produced at the same resolution as the reference DEMs for a comparison analysis. As a result of the experiment, the horizontal and vertical errors at the CPs indicated an accuracy of 1 to 3 pixels. In addition, the shapes and accuracy of two DEMs produced in areas where the effects of natural or artificial surface land were low were almost similar.

Evaluation of Shear Deformation Energy and Fatigue Performance of Single-layer and Multi-layer Metal Bellows (단층 및 다층 금속 벨로우즈의 전단 변형 에너지 및 피로성능 평가)

  • Kyeong-Seok Lee;Jin-Seok Yu;Young-Soo Jeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.39-45
    • /
    • 2024
  • Seismic safety of expansion joints for piping systems has been underscored by water pipe ruptures and leaks resulting from the Gyeongju and Pohang earthquakes. Metal bellows in piping systems are applied to prevent damage from earthquakes and road subsidence in soft ground. Designed with a series of corrugated segments called convolutions, metal bellows exhibit flexibility to accommodate displacements. Several studies have examined variations in convolution shapes and layers based on the intended performance to be evaluated. Nonetheless, the research on the seismic performance of complex bellows having multiple corrugation heights is limited. In this study, monotonic loading tests, cyclic loading tests, and fatigue tests were conducted to evaluate the shear performance in seismic conditions, of metal bellows with variable convolution heights. Single- and triple-layer bellows were considered for the experimentation. The results reveal that triple-layer bellows exhibit larger maximum deformation and fatigue life than single-layer bellows. However, the high stiffness of triple-layer bellows in resisting internal pressure poses certain disadvantages. The convolutions are less flexible at lower displacements and experience leakage at a rate related to the variable height of the convolutions in certain conditions. At lower deformation rates, the fatigue life is rated higher as the number of layers increase. It converges to a similar fatigue life at higher deformation rates.