• Title/Summary/Keyword: 지진성능평가

Search Result 729, Processing Time 0.032 seconds

Seismic Performance Assessment of a Mid-Rise RC Building subjected to 2016 Gyeongju Earthquake (2016년 경주지진에 의한 중층 RC 건물의 내진 성능 평가)

  • Lee, Do Hyung;Jeon, Jong-Su
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.7_spc
    • /
    • pp.473-483
    • /
    • 2016
  • In this paper, seismic performance assessment has been examined for a mid-rise RC building subjected to 2016 Gyeongju earthquake occurred in Korea. For the purpose of the paper, 2D external and internal frames in each direction of the building have been employed in the present comparative analyses. Nonlinear static pushover analyses have been conducted to estimate frame capacities. Nonlinear dynamic time-history analyses have also been carried out to examine demands for the frames subjected to ground motions recorded at stations in near of Gyeongju and a previous earthquake ground motion. Analytical predictions demonstrate that maximum demands are significantly affected by characteristics of both spectral acceleration response and spectrum intensity over a wide range of periods. Further damage potential of the frames has been evaluated in terms of fragility analyses using the same ground motions. Fragility results reveal that the ground motion characteristics of the Gyeongju earthquake have little influence on the seismic demand and fragility of frames.

Decision Making of Seismic Performance Management Using Seismic Risk Assessment (지진위험도평가 방법을 이용한 내진성능관리 의사결정)

  • Kim, Dong Joo;Choi, Ji Hye;Kim, Byeong Hwa
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.6
    • /
    • pp.329-339
    • /
    • 2019
  • The strategy for the management of earthquakes is shifting from post recovery to prevention; therefore, seismic performance management requires quantitative predictions of damage and the establishment of strategies for initial responses to earthquakes. Currently, seismic performance evaluation for seismic management in Korea consists of two stages: preliminary evaluation and detailed evaluation. Also, the priority of seismic performance management is determined in accordance with the preliminary evaluation. As a deterministic method, preliminary evaluation quantifies the physical condition and socio-economic importance of a facility by various predetermined indices, and the priority is decided by the relative value of the indices; however, with the deterministic method it is difficult to consider any uncertainty related to the return-year, epicenter, and propagation of seismic energy. Also this method cannot support tasks such as quantitative socio-economic damage and the provision of data for initial responses to earthquakes. Moreover, indirect damage is often greater than direct damage; therefore, a method to quantify damage is needed to enhance accuracy. In this paper, a Seismic Risk Assessment is used to quantify the cost of damage of road facilities in Pohang city and to support decision making.

A Study on the Seismic Design for Water Exthinguishing Piping Systems (수계 파이프 시스템의 내진설계에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.10-15
    • /
    • 2008
  • In this study, seismic design in sprinkler head pipeline of water extinguishing system has been carried out. This study describes a generation of artificial earthquake wave compatible with seismic design spectrum, and also analyzed the dynamic response spectra by the simulated earthquake motion. This study constructed powerful engineering base for seismic design, and presented seismic design techniques of water and gas extinguishing piping system. Also, this study readied basis that can apply seismic design and performance estimation of fire fighting system and performance rating as well as pipeline of water extinguishing system from result of this research. Hereafter, if additional research by earthquake magnitude and ground kind is approached, reliance elevation, safety raising and performance based design of fire fighting system see to achieve.

The Approach Methods of Improvement of Safety Standard for Architectural Glass and Curtain Wall (국내 건축용 유리 및 커튼월의 안전 기준 개선 방향에 관한 연구(II))

  • Seo, Yoon-Jeong;Seo, Dong-Goo;Shin, Yi-Chul;Kim, Dong-Eun;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.25-28
    • /
    • 2010
  • 최근 건축물의 초고층화에 따른 커튼월 시공에 따라 유리의 비중이 증가하고 있으나 커튼월 구조는 바람, 지진, 화재에 있어서 취약할 것이라 판단되어 국내외 건축용 유리 및 커튼월의 안전기준에 대한 조사를 실시하였다. 그 결과, 국내의 유리 기준은 단열 및 내풍압 성능에만 집중되어있으며 화재 및 지진, 안전 성능에 대한 기준이 미비한 실정이다. 따라서 국내에 적합한 유리 안전성 평가 프로세스를 구축하기 위한 기초 데이터를 마련하기 위해 유리 내화 실험을 시행하였다. 실험 결과, 일반유리, 복층유리, 강화유리, 접합유리 순의 파열 시간을 가지는 것을 알 수 있었으나 시험체 4개가 화재 초기에 파열되는 것으로 나타나 상층부로의 수직 화재 확대 위험성이 높을 것으로 판단된다.

  • PDF

Performance analysis of satellite maneuver and structure control using risk-sensitive control (위성 운동과 건물 진동제어에 활용된 리스크 센서티브 제어기의 성능 분석)

  • Won, Chang-Hui
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.3
    • /
    • pp.219-226
    • /
    • 1997
  • 지구를 원궤도로 돌고 있는 위성 운동과 지진에 흔들리는 건물 진동을 선형 확률적 미분 방정식으로 나타내고 최적화 제어를 위하여 리스크 센서티브 제어기를 사용한다. 리스크 센서티브 파라미터에 따라서 코스트 함수의 평균과 분산이 변하게 된다. 이 파라미터가 무한히 커지면 리스크 센서티브 제어기는 기존의 LQG 제어기와 같아지므로 리스크 샌서티브 제어이론은 LQG 제어 이론을 포함한 종합적인 이론이다. 이 논문에서는 리스크 센서티브 이론을 소개하고, 리스크 센서티브 제어 방식의 성능 측정및 평가 방법을 도출하기 위하여 공분산을 이용하면 리스크 센서티브 제어기는 기존의 LQG 제어기 보다 우수한 성능을 나타낸다는 것을 보여준다. 시뮬레이션을 통하여 위성의 자세및 궤도 운동 제어와 건물 진동 제어에 활용된 리스크 센서티브 제어기의 향상된 성능과 안정성을 보여준다.

  • PDF

Elasto-plastic Earthquake Response Analysis of Beam-Shear Wall Structural System (보-전단벽식 구조 시스템의 탄소성 지진응답 해석)

  • 정명채;이정원
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.57-67
    • /
    • 1997
  • The objective of present paper is to investigate elasto-plastic behaviour and estimate the resistance capacity of a beam-shear wall structural system against earthquake ground accleration exciations. Pushover analysis is adopted to estimate inttiate and post stiffnesses and yielding point for inelastic response analysis in LPM (Lumped Parameter Mass) model, and modified Clough model is used as the hysteresis rule of each story. Three earthquake waves are used in the analysis but their peak ground accelerations are changed to be 0.12g, 0.24g. It is assumed that the earthquakes act in the longigtudianl direction of a 25 Story apartment building which consists of two some unit plan. The distribution of story ratio and ductility ratio are estimated and discussed within Korean, Japanese code and UBC.

  • PDF

A Study on the Relationship between the Eccentricity and the Level of Damage in the Seismic Response of Buildings with Plan Irregularities (지진 하중을 받는 평면 비정형 건물의 편심과 손상도의 상관관계에 대한 연구)

  • Jeong, Seoung-Hoon;Lee, Kwang-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.49-57
    • /
    • 2010
  • Most previous research on the seismic response of structures with plan irregularities have focused on the relationship between the eccentricity and the amount of torsion. This approach cannot provide the direct relationship between the irregularity and the damage. Therefore, an investigation on the relationship between the eccentricities of buildings with plan irregularities and the damage index was performed. Inelastic dynamic time-history analyses were performed on one-story buildings with various eccentricities. For the damage assessment, a 3D damage index was adopted to reflect the effect of the bi-directional response and torsion. Based on the analysis results, buildings with eccentricities of 10%, 20% and 30% will suffer 3~5%, 13~18%, and 33~47% more damage than their regular counterparts, respectively.

Characterizing the Performance of New Seismic Stations in Southeastern Region, Korea Using Seismic Noise Levels (배경잡음 수준 분석에 의한 동남권 신규 관측소 성능 특성 평가)

  • Shin, Jin Soo;Seong, Yun-Jeong;Son, Minkyung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.6
    • /
    • pp.321-327
    • /
    • 2019
  • We performed seismic noise level analysis to access the proper functioning of 11 newly established seismic stations in the southeastern region of Korea. One-hour long segments of seismograms were selected from the continuous data of the 3 elements for 61 days from March 1, 2019. For each segment of data, the power spectral density (PSD) was estimated from the continuous back ground noise data of the 3 elements for periods ranging from 0.02~100 s. The median noise levels (NLs) of the stations were compared with the new noise model (NNM) of USGS and NLs of station TJN installed in a tunnel on a granite basement. We observed that the NLs of the newly installed seismometers were between the upper and lower limit of the NNM. In a comparison with the noise level of station TJN, the new seismometers had their own noteworthy features. The NLs from accelerometers (Epi-sensors) were ~ 40 dB higher than the NLs from velocimeters (STS-sensors) for periods > 10 s, which is because the small and light Epi-sensors are sensitive to environmental changes. Daily and weekly variations in spectral noise level were observed clearly in short periods < 1 s, and these are considered to be related to human activities. The seismometers in boreholes showed ~20 dB weaker NLs in the cultural noise band. The NLs of accelerometers at a depth of 30 m were also much lower by 30 dB for long periods > 10 sec. Overall the functioning of the new velocimeter and accelerometer stations was reliable for periods ranging from 0.02~100 s and 0.02~10 s, respectively.

Hysteretic Behavior and Seismic Resistant Capacity of Precast Concrete Beam-to-Column Connections (프리캐스트 콘크리트 보-기둥 접합부의 이력거동 및 내진성능)

  • Choi, Hyun-Ki;Choi, Yun-Cheul;Choi, Chang-Sik
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.61-71
    • /
    • 2010
  • Five half-scale beam-to-column connections in a precast concrete frame were tested with cyclic loading that simulated earthquake-type motions. Five half -scale interior beam-column assemblies representing a portion of a frame subjected to simulated seismic loading were tested, including one monolithic specimen and four precast specimens. Variables included the detailing used at the joint to achieve a structural continuity of the beam reinforcement, and the type of special reinforcement in the connection (whether ECC or transverse reinforcement). The specimen design followed the strong-column-weak-beam concept. The beam reinforcement was purposely designed and detailed to develop plastic hinges at the beam and to impose large inelastic shear force demands into the joint. The joint performance was evaluated on the basis of connection strength, stiffness, energy dissipation, and drift capacity. From the test results, the plastic hinges at the beam controlled the specimen failure. In general, the performance of the beam-to-column connections was satisfactory. The joint strength was 1.15 times of that expected for monolithic reinforced concrete construction. The specimen behavior was ductile due to tensile deformability by ECC and the yielding steel plate, while the strength was nearly constant up to a drift of 3.5 percent.

Performance Evaluation of the Cast-in-place Anchor Bolt in Non-cracked Concrete used in Power Plant Facilities (비균열 콘크리트에 매립된 발전설비 정착부 선 설치 앵커의 구조성능 평가)

  • Kim, Dong-Ik;Jong, Woo-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.250-258
    • /
    • 2019
  • The seismic performance and stability of operating facilities installed in domestic power plants need to be verified because of the increased incidence of earthquakes resulting in power plant damage due to the overturning failure of electric operating facilities. In this study, a structural performance evaluation of the anchor bolts constructed to setup the operating facilities on concrete slabs was carried out through an on-site inspection of power plants, called Daechung-Dam. M10 J hook and M12 J hook anchor bolts were installed in the field unit. According to the ASTM E 488-96 specifications, anchor bolt pullout and shear tests were carried out and compared with the anchor-bolt design standards. The results from the tension and shear pullout tests showed that the M10 and M12 J hook anchor bolts had higher performance than the required design load. Thus, they were found to be safe enough. Nevertheless, more research in the field of analytical study will be needed in the near future.