• 제목/요약/키워드: 지진성능평가

Search Result 734, Processing Time 0.022 seconds

A study on the experimental evaluation of an Angle Type Anchorage System (Angle형 기기 정착부의 성능평가에 관한 실험적 연구)

  • 김강식;서용표;유원진;김갑순
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.266-274
    • /
    • 2002
  • A typical case where the effects of prying in the base angle type anchorage system with expansion bolt. This connection consists of an angle which is attathed to an equipment cabinet and bolted to a concrete slab via an expantion bolt. A seismic analysis of the cabinet may indicate a vertical load, P, transferred to the vertical leg of the angle due to overturning of the cabinet. Due to the eccentricity, b(e), and the continuous beam action in the base member, the load resisted by the bolt will be amplified by a factor λ. Thus, in this study, experimental evaluation of the anchorage system is executed.

  • PDF

Introduction of the Building Standard Law of Japan and the Performance-Based Seismic Design Methodology (일본의 내진설계법 및 내진성능 평가법의 소개)

  • 전대한;노필성
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.341-348
    • /
    • 2002
  • This manuscript introduces the Building Standard Law of Japan revised at 2000, June. Recently, The Building Standard Law of Japan was revised into the performance-based design format following the trend of international. The structural performance was evaluated for two limiting states; serviceability and soundness limit state, and safety limit state. The design earthquake forces were determined on the basis of seismic activities of the construction site, taking into consideration (a)characteristics of focal mechanism, (b)amplification by local surfaces geology, and (c)soil-structure interaction, in addition to the properties of the planned building including scale, configuration, foundation system, and structural characteristics.

  • PDF

Lifetime Seismic Risk of Offshore Structures with a Built-in Vibration Control Device (제진장치 설치 해양구조물의 생애주기 지진위험도)

  • Kim, Dong-Hyawn
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.48-54
    • /
    • 2010
  • The analysis of the seismic risk of an offshore structure with a control device is presented. First, a probability density function was developed to represent seismic hazard, and seismic fragility under artificial earthquake conditions was determined. Fragility curves for an offshore structure with both passive and active control devices were determined. Displacement criteria were set to evaluate the performance of the structure. Based on numerical analysis, the seismic risk to the structure was considerably reduced when the structure had a seismic control device. The seismic risk to the actively controlled structure was decreased by 80% compared to the uncontrolled case. Reasonable performance evaluations of offshore structure with control devices can be conducted through risk analysis.

Procedures of Biaxial Seismic Capacity Test and Seismic Performance Evaluation (수평이축방향 내진역량시험과 내진성능평가 절차)

  • 김재관;김익현;이재호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.453-460
    • /
    • 2001
  • The seismic capacity of columns usually has been tested in uniaxial loading condition. The seismic performance used to be evaluated under the same assumption. Since the real earthquake motion is multi-directional, the effects of multi-directional excitation on the seismic capacity of structures need to be carefully examined. In this paper, a frequency dependent alternate biaxial cyclic loading test is proposed as an evaluation method of seismic capacity under multi-directional excitation. Four test specimens were made and tested to study the degradation of strength, stiffness and ductility under biaxial loading condition. A multi- directional excitation. The capacity is obtained using frequency dependent alternate biaxial cyclic loading test. The orthogonal effect is taken into account by increasing the demand.

  • PDF

Seismic Evaluation of Face-Loaded Unreinforced Masonry Walls (URM) (면외하중에 대한 비보강 조적벽의 내진성능 평가)

  • 유은진;이한선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.304-311
    • /
    • 2001
  • Unreinforced masonry is widely used as a structural material in residential constructions and known to have poor seismic performance in the out-of-plane rather than in-plane behavior. In countries of lower seismicity such as Korea, it is necessary to check the possibility of the mode of the out-of-plane failure. Though face loading is a major cause of the failure of masonary walls, Korean Seismic Code does not include provision for face-loaded unreinforced masonry walls. This paper briefly reviews the concept of analysis for unreinforced masonry walls subjected to face-load excitation proposed by Priestley, and its applicatility to Korean case.

  • PDF

Evaluation of Bridge Fragility by Capacity Spectrum Method (성능스펙트럼에 의한 교량의 손상도 평가)

  • ;Shinozuka, Masanobu
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.329-336
    • /
    • 2001
  • This study examines the fragility curves of a bridge by Capacity Spectrum Method. A sample of 10 nominally identical but statistically different bridge and 80 ground-motion time histories are considered to account for the uncertainties related to the structural capacity and ground motion, respectively. The comparison of fragility curves by Capacity Spectrum Method with those by time-history analysis indicates that the agreement is excellent for the state of at least minor damage, but not as good for the state of major damage where nonlinear effects clearly play a crucial role. Overall, however, the agreement is adequate even in the state of major damage considering the large number of typical assumptions under which the analyses of fragility characteristics are performed.

  • PDF

Seismic Performance Evaluation of Circular RC Bridge Piers with Shear-Flexure Behavior (휨-전단 복합 거동 원형 RC교각의 내진성능 평가)

  • 김병석;곽임종;조창백;조정래
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.337-344
    • /
    • 2001
  • Some as-built drawings in national roadway bridges in Korea were examined. There are many bridge piers, whose aspect ratios are in the vicinity of 2.5. These columns are expected to do shear-flexure behaviour and have large scale effect between full and reduced scale model. In the study, full and 1/2 scale model tests on the shear-flexure behaviour columns were carried out. The seismic performance of existing bridge piers without seismic details were examined by Quasi Static Test

  • PDF

Seismic Performance Evaluation of RC Bridge Piers using Capacity Spectrum and Energy Analysis (역량스펙트럼 및 에너지분석을 이용한 RC교각의 내진성능평가에 관한 연구)

  • 정영수;박종협
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.361-367
    • /
    • 2001
  • This research aims at evaluating the seismic performance of the R/C bridge piers, which were seismically designed in accordance with the seismic provision of limited ductile behavior of Eurocode 8. Pseudo dynamic test for six(6) circular RC bridge piers has been carried out so at to investigate their seismic performance subjected to experted artificial earthquake motions. The objective of this experimental study is to investigate the hysteretic behavior of reinforced concrete bridge piers. Important test parameters are confinement steel ratio, input ground motion, etc. The seismic behavior of circular concrete piers under artificial ground motions has been evaluated through displacement ductility, energy analysis, capacity spectrum. It can be concluded that RC bridge piers designed in the seismic code of limited ductile behavior of Eurocode 8 have been determined to show good seismic performance even under expected artificial earthquakes in moderate seismicity region.

  • PDF

Seismic Performance Evaluation of Structures Retrofitted with Viscoelastic-Slit Hybrid Dampers (점탄성-슬릿 복합댐퍼로 보강된 건물의 내진성능평가)

  • Kim, Minsung;Xu, Zhaodong;Kim, Jinkoo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.361-367
    • /
    • 2018
  • This study investigates the seismic performance of a hybrid seismic energy dissipation device composed of a viscoelastic damper and a steel slit damper connected in parallel. A moment-framed structure is designed without seismic load and is retrofitted with the hybrid dampers. The model structure is transformed into an equivalent simplified system to find out optimum story-wise damper distribution pattern using genetic algorithm. The effectiveness of the hybrid damper is investigated by fragility analysis of the structure with and without the dampers. The analysis results show that after seismic retrofit the probability of reaching damage states, especially the complete damage state, of the structure turn out to be significantly reduced.

Experimental Performance Evaluation of Displacement Amplification Damping Systems Using Cables and Pulleys (케이블과 도르래를 이용한 변위증폭형 감쇠시스템의 실험적 성능평가)

  • Oh, Jintak;Jung, In Yong;Ryu, Jaeho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.149-156
    • /
    • 2020
  • The vibration control device such as the damper can be used to reinforce the seismic performance of structures. The damper is activated by the deformation of structures during earthquake; however, the deformation of structures is extremely small, causing difficulty in using the damper. Therefore, there is a need for a method capable of amplifying small deformities and transmitting them to the damper. The purpose of this paper is to develop and evaluate a displacement amplification seismic system using cable-pulley. The appropriate cable was selected through a cable tensile performance test and the results of the frame experiment were compared with theoretical displacement amplification ratio values. As a result, it may be said that the proposed system using cable-pulley is useful for displacement amplification.